Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Clinical evaluation of ramus frame and staple bone implants

Identifieur interne : 000E86 ( Istex/Corpus ); précédent : 000E85; suivant : 000E87

Clinical evaluation of ramus frame and staple bone implants

Auteurs : J. B. Meyer Jr. ; K. R. Kotwal

Source :

RBID : ISTEX:1DD2FD74494B1BDD6661BDEB2923697082088CD7

English descriptors

Abstract

Abstract: Atwood13 pointed out that “variability of human response (resistance to infection, susceptibility to bone resorption, and psychologic capacity) demands more basic research and clinical trials to improve success”. This study can serve as a baseline for further longitudinal studies and controlled clinical research. Barring tissue or systemic complications, the prosthodontist must take the responsibility through sound treatment principles and awareness to ensure continued satisfaction and success of these implant systems.

Url:
DOI: 10.1016/0022-3913(86)90081-8

Links to Exploration step

ISTEX:1DD2FD74494B1BDD6661BDEB2923697082088CD7

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Clinical evaluation of ramus frame and staple bone implants</title>
<author>
<name sortKey="Meyer Jr, J B" sort="Meyer Jr, J B" uniqKey="Meyer Jr J" first="J. B." last="Meyer Jr.">J. B. Meyer Jr.</name>
<affiliation>
<mods:affiliation>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Kotwal, K R" sort="Kotwal, K R" uniqKey="Kotwal K" first="K. R." last="Kotwal">K. R. Kotwal</name>
<affiliation>
<mods:affiliation>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:1DD2FD74494B1BDD6661BDEB2923697082088CD7</idno>
<date when="1986" year="1986">1986</date>
<idno type="doi">10.1016/0022-3913(86)90081-8</idno>
<idno type="url">https://api.istex.fr/document/1DD2FD74494B1BDD6661BDEB2923697082088CD7/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000E86</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000E86</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Clinical evaluation of ramus frame and staple bone implants</title>
<author>
<name sortKey="Meyer Jr, J B" sort="Meyer Jr, J B" uniqKey="Meyer Jr J" first="J. B." last="Meyer Jr.">J. B. Meyer Jr.</name>
<affiliation>
<mods:affiliation>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Kotwal, K R" sort="Kotwal, K R" uniqKey="Kotwal K" first="K. R." last="Kotwal">K. R. Kotwal</name>
<affiliation>
<mods:affiliation>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">The Journal of Prosthetic Dentistry</title>
<title level="j" type="abbrev">YMPR</title>
<idno type="ISSN">0022-3913</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1986">1986</date>
<biblScope unit="volume">55</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="87">87</biblScope>
<biblScope unit="page" to="92">92</biblScope>
</imprint>
<idno type="ISSN">0022-3913</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0022-3913</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Atrophic mandible</term>
<term>Clinical evaluation</term>
<term>Clinical experience</term>
<term>Compressive loading</term>
<term>Dent assoc</term>
<term>Dental implants</term>
<term>Denture</term>
<term>Implant</term>
<term>Implant system</term>
<term>Implant systems</term>
<term>Inferior alveolar nerve paresthesia</term>
<term>Labial aspect</term>
<term>Laboratory relines</term>
<term>Locking nuts</term>
<term>Lower denture</term>
<term>Mandibular</term>
<term>Mandibular denture</term>
<term>Mandibular ramus frame</term>
<term>Mandibular staple bone plate</term>
<term>Maxillary</term>
<term>Maxillary arch</term>
<term>Maxillary relines</term>
<term>Paresthesia</term>
<term>Ramus</term>
<term>Ramus frame</term>
<term>Ramus frame implant</term>
<term>Ramus frame implant patient</term>
<term>Ramus frame implant patients</term>
<term>Ramus frame patient</term>
<term>Ramus frame patients</term>
<term>Relines</term>
<term>Senior resident</term>
<term>Soft tissue</term>
<term>Staple</term>
<term>Staple bone plate implants</term>
<term>Staple implant</term>
<term>Staple implant patient</term>
<term>Staple implant patients</term>
<term>Staple implants</term>
<term>Steel burs</term>
<term>Tissue proliferation</term>
<term>Transosteal pins</term>
<term>Unfavorable comments</term>
<term>William beaumont army</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Atrophic mandible</term>
<term>Clinical evaluation</term>
<term>Clinical experience</term>
<term>Compressive loading</term>
<term>Dent assoc</term>
<term>Dental implants</term>
<term>Denture</term>
<term>Implant</term>
<term>Implant system</term>
<term>Implant systems</term>
<term>Inferior alveolar nerve paresthesia</term>
<term>Labial aspect</term>
<term>Laboratory relines</term>
<term>Locking nuts</term>
<term>Lower denture</term>
<term>Mandibular</term>
<term>Mandibular denture</term>
<term>Mandibular ramus frame</term>
<term>Mandibular staple bone plate</term>
<term>Maxillary</term>
<term>Maxillary arch</term>
<term>Maxillary relines</term>
<term>Paresthesia</term>
<term>Ramus</term>
<term>Ramus frame</term>
<term>Ramus frame implant</term>
<term>Ramus frame implant patient</term>
<term>Ramus frame implant patients</term>
<term>Ramus frame patient</term>
<term>Ramus frame patients</term>
<term>Relines</term>
<term>Senior resident</term>
<term>Soft tissue</term>
<term>Staple</term>
<term>Staple bone plate implants</term>
<term>Staple implant</term>
<term>Staple implant patient</term>
<term>Staple implant patients</term>
<term>Staple implants</term>
<term>Steel burs</term>
<term>Tissue proliferation</term>
<term>Transosteal pins</term>
<term>Unfavorable comments</term>
<term>William beaumont army</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Abstract: Atwood13 pointed out that “variability of human response (resistance to infection, susceptibility to bone resorption, and psychologic capacity) demands more basic research and clinical trials to improve success”. This study can serve as a baseline for further longitudinal studies and controlled clinical research. Barring tissue or systemic complications, the prosthodontist must take the responsibility through sound treatment principles and awareness to ensure continued satisfaction and success of these implant systems.</div>
</front>
</TEI>
<istex>
<corpusName>elsevier</corpusName>
<keywords>
<teeft>
<json:string>denture</json:string>
<json:string>ramus</json:string>
<json:string>implant</json:string>
<json:string>mandibular</json:string>
<json:string>staple</json:string>
<json:string>relines</json:string>
<json:string>lower denture</json:string>
<json:string>ramus frame</json:string>
<json:string>paresthesia</json:string>
<json:string>maxillary</json:string>
<json:string>implant system</json:string>
<json:string>ramus frame implant</json:string>
<json:string>staple implant patients</json:string>
<json:string>ramus frame patient</json:string>
<json:string>clinical experience</json:string>
<json:string>ramus frame patients</json:string>
<json:string>tissue proliferation</json:string>
<json:string>staple implants</json:string>
<json:string>ramus frame implant patient</json:string>
<json:string>mandibular denture</json:string>
<json:string>mandibular ramus frame</json:string>
<json:string>mandibular staple bone plate</json:string>
<json:string>labial aspect</json:string>
<json:string>laboratory relines</json:string>
<json:string>william beaumont army</json:string>
<json:string>staple bone plate implants</json:string>
<json:string>soft tissue</json:string>
<json:string>staple implant patient</json:string>
<json:string>atrophic mandible</json:string>
<json:string>senior resident</json:string>
<json:string>ramus frame implant patients</json:string>
<json:string>compressive loading</json:string>
<json:string>staple implant</json:string>
<json:string>steel burs</json:string>
<json:string>clinical evaluation</json:string>
<json:string>inferior alveolar nerve paresthesia</json:string>
<json:string>maxillary relines</json:string>
<json:string>implant systems</json:string>
<json:string>maxillary arch</json:string>
<json:string>unfavorable comments</json:string>
<json:string>dental implants</json:string>
<json:string>dent assoc</json:string>
<json:string>locking nuts</json:string>
<json:string>transosteal pins</json:string>
</teeft>
</keywords>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Maxillofacial prosthetics • dental implants</value>
</json:item>
</subject>
<language>
<json:string>eng</json:string>
</language>
<originalGenre>
<json:string>Full-length article</json:string>
</originalGenre>
<qualityIndicators>
<score>5.569</score>
<pdfWordCount>2717</pdfWordCount>
<pdfCharCount>17515</pdfCharCount>
<pdfVersion>1.3</pdfVersion>
<pdfPageCount>6</pdfPageCount>
<pdfPageSize>576 x 828 pts</pdfPageSize>
<refBibsNative>true</refBibsNative>
<abstractWordCount>71</abstractWordCount>
<abstractCharCount>534</abstractCharCount>
<keywordCount>1</keywordCount>
</qualityIndicators>
<title>Clinical evaluation of ramus frame and staple bone implants</title>
<pii>
<json:string>0022-3913(86)90081-8</json:string>
</pii>
<genre>
<json:string>research-article</json:string>
</genre>
<host>
<title>The Journal of Prosthetic Dentistry</title>
<language>
<json:string>unknown</json:string>
</language>
<publicationDate>1986</publicationDate>
<issn>
<json:string>0022-3913</json:string>
</issn>
<pii>
<json:string>S0022-3913(86)X8075-5</json:string>
</pii>
<volume>55</volume>
<issue>1</issue>
<pages>
<first>87</first>
<last>92</last>
</pages>
<genre>
<json:string>journal</json:string>
</genre>
</host>
<namedEntities>
<unitex>
<date>
<json:string>1974</json:string>
<json:string>1981</json:string>
<json:string>1970</json:string>
<json:string>1986</json:string>
<json:string>1975</json:string>
<json:string>1964</json:string>
<json:string>1982</json:string>
<json:string>1978</json:string>
</date>
<geogName></geogName>
<orgName>
<json:string>William Beaumont Army Medical Center</json:string>
<json:string>American Society for Testing</json:string>
<json:string>Walter Reed Army Medical Center</json:string>
</orgName>
<orgName_funder></orgName_funder>
<orgName_provider></orgName_provider>
<persName>
<json:string>I. Summary</json:string>
<json:string>Denture</json:string>
</persName>
<placeName></placeName>
<ref_url></ref_url>
<ref_bibl>
<json:string>October 1984</json:string>
<json:string>Roberts et al</json:string>
<json:string>March 1985</json:string>
</ref_bibl>
<bibl></bibl>
</unitex>
</namedEntities>
<ark>
<json:string>ark:/67375/6H6-BM3RM852-6</json:string>
</ark>
<categories>
<wos>
<json:string>1 - science</json:string>
<json:string>2 - dentistry, oral surgery & medicine</json:string>
</wos>
<scienceMetrix>
<json:string>1 - health sciences</json:string>
<json:string>2 - clinical medicine</json:string>
<json:string>3 - dentistry</json:string>
</scienceMetrix>
<scopus>
<json:string>1 - Health Sciences</json:string>
<json:string>2 - Dentistry</json:string>
<json:string>3 - Oral Surgery</json:string>
</scopus>
<inist>
<json:string>1 - sciences appliquees, technologies et medecines</json:string>
<json:string>2 - sciences biologiques et medicales</json:string>
<json:string>3 - sciences medicales</json:string>
</inist>
</categories>
<publicationDate>1986</publicationDate>
<author>
<json:item>
<name>J.B. Meyer, Jr. D.M.D.</name>
<affiliations>
<json:string>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</json:string>
</affiliations>
</json:item>
<json:item>
<name>K.R. Kotwal B.D.S., D.M.D., M.S.</name>
<affiliations>
<json:string>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</json:string>
</affiliations>
</json:item>
</author>
<articleId>
<json:string>86900818</json:string>
</articleId>
<arkIstex>ark:/67375/6H6-BM3RM852-6</arkIstex>
<abstract>Abstract: Atwood13 pointed out that “variability of human response (resistance to infection, susceptibility to bone resorption, and psychologic capacity) demands more basic research and clinical trials to improve success”. This study can serve as a baseline for further longitudinal studies and controlled clinical research. Barring tissue or systemic complications, the prosthodontist must take the responsibility through sound treatment principles and awareness to ensure continued satisfaction and success of these implant systems.</abstract>
<pmid>
<json:string>3511246</json:string>
</pmid>
<serie>
<title>Trans Third Int Conf Oral Surg</title>
<language>
<json:string>unknown</json:string>
</language>
<pages>
<first>526</first>
<last>537</last>
</pages>
</serie>
<copyrightDate>1986</copyrightDate>
<doi>
<json:string>10.1016/0022-3913(86)90081-8</json:string>
</doi>
<id>1DD2FD74494B1BDD6661BDEB2923697082088CD7</id>
<score>1</score>
<fulltext>
<json:item>
<extension>pdf</extension>
<original>true</original>
<mimetype>application/pdf</mimetype>
<uri>https://api.istex.fr/document/1DD2FD74494B1BDD6661BDEB2923697082088CD7/fulltext/pdf</uri>
</json:item>
<json:item>
<extension>zip</extension>
<original>false</original>
<mimetype>application/zip</mimetype>
<uri>https://api.istex.fr/document/1DD2FD74494B1BDD6661BDEB2923697082088CD7/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/1DD2FD74494B1BDD6661BDEB2923697082088CD7/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a" type="main" xml:lang="en">Clinical evaluation of ramus frame and staple bone implants</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>ELSEVIER</publisher>
<availability>
<p>©1986 The C. V. Mosby Company</p>
</availability>
<date>1986</date>
</publicationStmt>
<sourceDesc>
<biblStruct type="inbook">
<analytic>
<title level="a" type="main" xml:lang="en">Clinical evaluation of ramus frame and staple bone implants</title>
<author xml:id="author-0000">
<persName>
<forename type="first">J.B.</forename>
<surname>Meyer, Jr.</surname>
</persName>
<roleName type="degree">D.M.D.</roleName>
<note type="biography">Reprint requests to:Dr. Jack B. Meyer, Jr. 6913Sharmel Ln. Columbus, GA 31904.</note>
<note type="biography">Major, DC, USA; Senior Resident, Removable Prosthodontic Residency Program.</note>
<affiliation>Reprint requests to:Dr. Jack B. Meyer, Jr. 6913Sharmel Ln. Columbus, GA 31904.</affiliation>
<affiliation>Major, DC, USA; Senior Resident, Removable Prosthodontic Residency Program.</affiliation>
<affiliation>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</affiliation>
</author>
<author xml:id="author-0001">
<persName>
<forename type="first">K.R.</forename>
<surname>Kotwal</surname>
</persName>
<roleName type="degree">B.D.S., D.M.D., M.S.</roleName>
<note type="biography">Colonel, DC, USA; Director, Removable Prosthodontic Residency Program.</note>
<affiliation>Colonel, DC, USA; Director, Removable Prosthodontic Residency Program.</affiliation>
<affiliation>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</affiliation>
</author>
<idno type="istex">1DD2FD74494B1BDD6661BDEB2923697082088CD7</idno>
<idno type="DOI">10.1016/0022-3913(86)90081-8</idno>
<idno type="PII">0022-3913(86)90081-8</idno>
<idno type="ArticleID">86900818</idno>
</analytic>
<monogr>
<title level="j">The Journal of Prosthetic Dentistry</title>
<title level="j" type="abbrev">YMPR</title>
<idno type="pISSN">0022-3913</idno>
<idno type="PII">S0022-3913(86)X8075-5</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1986"></date>
<biblScope unit="volume">55</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="87">87</biblScope>
<biblScope unit="page" to="92">92</biblScope>
</imprint>
</monogr>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<creation>
<date>1986</date>
</creation>
<langUsage>
<language ident="en">en</language>
</langUsage>
<abstract xml:lang="en">
<p>Abstract: Atwood13 pointed out that “variability of human response (resistance to infection, susceptibility to bone resorption, and psychologic capacity) demands more basic research and clinical trials to improve success”. This study can serve as a baseline for further longitudinal studies and controlled clinical research. Barring tissue or systemic complications, the prosthodontist must take the responsibility through sound treatment principles and awareness to ensure continued satisfaction and success of these implant systems.</p>
</abstract>
<textClass>
<keywords scheme="keyword">
<list>
<head>article-category</head>
<item>
<term>Maxillofacial prosthetics • dental implants</term>
</item>
</list>
</keywords>
</textClass>
</profileDesc>
<revisionDesc>
<change when="1986">Published</change>
</revisionDesc>
</teiHeader>
</istex:fulltextTEI>
<json:item>
<extension>txt</extension>
<original>false</original>
<mimetype>text/plain</mimetype>
<uri>https://api.istex.fr/document/1DD2FD74494B1BDD6661BDEB2923697082088CD7/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Elsevier doc found" wicri:toSee="Elsevier, no converted or simple article">
<istex:xmlDeclaration>version="1.0" encoding="utf-8"</istex:xmlDeclaration>
<istex:docType PUBLIC="-//ES//DTD journal article DTD version 5.0.1//EN//XML" URI="art501.dtd" name="istex:docType"></istex:docType>
<istex:document>
<article version="5.0" xml:lang="en" docsubtype="fla">
<item-info>
<jid>YMPR</jid>
<aid>86900818</aid>
<ce:pii>0022-3913(86)90081-8</ce:pii>
<ce:doi>10.1016/0022-3913(86)90081-8</ce:doi>
<ce:copyright type="unknown" year="1986">The C. V. Mosby Company</ce:copyright>
<ce:doctopics>
<ce:doctopic>
<ce:text>Maxillofacial prosthetics • dental implants</ce:text>
</ce:doctopic>
</ce:doctopics>
</item-info>
<head>
<ce:title>Clinical evaluation of ramus frame and staple bone implants</ce:title>
<ce:author-group>
<ce:author>
<ce:given-name>J.B.</ce:given-name>
<ce:surname>Meyer</ce:surname>
<ce:suffix>Jr.</ce:suffix>
<ce:degrees>D.M.D.</ce:degrees>
<ce:cross-ref refid="cor1">
<ce:sup>*</ce:sup>
</ce:cross-ref>
<ce:cross-ref refid="fn1">
<ce:sup>*</ce:sup>
</ce:cross-ref>
</ce:author>
<ce:author>
<ce:given-name>K.R.</ce:given-name>
<ce:surname>Kotwal</ce:surname>
<ce:degrees>B.D.S., D.M.D., M.S.</ce:degrees>
<ce:cross-ref refid="fn2">
<ce:sup>**</ce:sup>
</ce:cross-ref>
</ce:author>
<ce:affiliation>
<ce:textfn>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</ce:textfn>
</ce:affiliation>
<ce:correspondence id="cor1">
<ce:label>*</ce:label>
<ce:text>
<ce:italic>Reprint requests to:</ce:italic>
<ce:small-caps>Dr. Jack B. Meyer, Jr.</ce:small-caps>
6913
<ce:small-caps>Sharmel Ln. Columbus, GA</ce:small-caps>
31904.</ce:text>
</ce:correspondence>
<ce:footnote id="fn1">
<ce:label>*</ce:label>
<ce:note-para>Major, DC, USA; Senior Resident, Removable Prosthodontic Residency Program.</ce:note-para>
</ce:footnote>
<ce:footnote id="fn2">
<ce:label>**</ce:label>
<ce:note-para>Colonel, DC, USA; Director, Removable Prosthodontic Residency Program.</ce:note-para>
</ce:footnote>
</ce:author-group>
<ce:abstract id="ab1" class="author" xml:lang="en">
<ce:section-title>Abstract</ce:section-title>
<ce:abstract-sec>
<ce:simple-para>Atwood
<ce:sup>13</ce:sup>
pointed out that “variability of human response (resistance to infection, susceptibility to bone resorption, and psychologic capacity) demands more basic research and clinical trials to improve success”. This study can serve as a baseline for further longitudinal studies and controlled clinical research. Barring tissue or systemic complications, the prosthodontist must take the responsibility through sound treatment principles and awareness to ensure continued satisfaction and success of these implant systems.</ce:simple-para>
</ce:abstract-sec>
</ce:abstract>
</head>
<tail>
<ce:bibliography>
<ce:section-title>References</ce:section-title>
<ce:bibliography-sec>
<ce:bib-reference id="bib1">
<ce:label>1.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Kerley</ce:surname>
<ce:given-name>TR</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>The ramus frame implant</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Oral Surg</sb:maintitle>
</sb:title>
<sb:volume-nr>39</sb:volume-nr>
</sb:series>
<sb:date>1981</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>415</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib2">
<ce:label>2.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Small</ce:surname>
<ce:given-name>IA</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>Metal implants and the mandibular staple bone plate</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Oral Surg</sb:maintitle>
</sb:title>
<sb:volume-nr>33</sb:volume-nr>
</sb:series>
<sb:date>1975</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>8</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib3">
<ce:label>3.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Schnitman</ce:surname>
<ce:given-name>PA</ce:given-name>
</sb:author>
</sb:authors>
</sb:contribution>
<sb:host>
<sb:edited-book>
<sb:title>
<sb:maintitle>Recommendations of the consensus development conference on dental implants</sb:maintitle>
</sb:title>
<sb:book-series>
<sb:series>
<sb:title>
<sb:maintitle>J Am Dent Assoc</sb:maintitle>
</sb:title>
<sb:volume-nr>98</sb:volume-nr>
</sb:series>
</sb:book-series>
<sb:date>1979</sb:date>
</sb:edited-book>
<sb:pages>
<sb:first-page>373</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib4">
<ce:label>4.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Helfrick</ce:surname>
<ce:given-name>JE</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>Mandibular staple bone plate: Long-term evaluation of 250 cases</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Am Dent Assoc</sb:maintitle>
</sb:title>
<sb:volume-nr>103</sb:volume-nr>
</sb:series>
<sb:date>1982</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>318</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib5">
<ce:label>5.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>O'Malley</ce:surname>
<ce:given-name>JP</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>The mandibular orthopedic bone staple in the treatment of the atrophic mandible</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Prosthet Dent</sb:maintitle>
</sb:title>
<sb:volume-nr>48</sb:volume-nr>
</sb:series>
<sb:date>1982</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>432</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib6">
<ce:label>6.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Roberts</ce:surname>
<ce:given-name>HO</ce:given-name>
</sb:author>
<sb:author>
<ce:surname>Roberts</ce:surname>
<ce:given-name>RA</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>The ramus endosseous implant</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Southern Calif Dent Assoc</sb:maintitle>
</sb:title>
<sb:volume-nr>38</sb:volume-nr>
</sb:series>
<sb:date>1970</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>571</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib7">
<ce:label>7.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Nelson</ce:surname>
<ce:given-name>RW</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>The ramus frame implant for stabilizing impossible lower dentures</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>Oral Implantol</sb:maintitle>
</sb:title>
<sb:volume-nr>4</sb:volume-nr>
</sb:series>
<sb:date>1974</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>45</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib8">
<ce:label>8.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Small</ce:surname>
<ce:given-name>IA</ce:given-name>
</sb:author>
<sb:author>
<ce:surname>Kobernick</ce:surname>
<ce:given-name>SD</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>Implantation of threaded stainless steel pins in the dog mandible</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:edited-book>
<sb:book-series>
<sb:series>
<sb:title>
<sb:maintitle>Trans Third Int Conf Oral Surg</sb:maintitle>
</sb:title>
</sb:series>
</sb:book-series>
<sb:date>1968</sb:date>
</sb:edited-book>
<sb:pages>
<sb:first-page>526</sb:first-page>
<sb:last-page>537</sb:last-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib9">
<ce:label>9.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Metz</ce:surname>
<ce:given-name>HH</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>Mandibular staple implant for an atrophic mandibular ridge. Solving retention difficulties in a dentures</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Prosthet Dent</sb:maintitle>
</sb:title>
<sb:volume-nr>32</sb:volume-nr>
</sb:series>
<sb:date>1974</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>572</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib10">
<ce:label>10.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Guckes</ce:surname>
<ce:given-name>AD</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>Counseling and related factors influencing satisfaction with dentures</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Prosthet Dent</sb:maintitle>
</sb:title>
<sb:volume-nr>39</sb:volume-nr>
</sb:series>
<sb:date>1978</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>259</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib11">
<ce:label>11.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>McKinstry</ce:surname>
<ce:given-name>RE</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>Clinical evaluation of the mandibular staple bone plate</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Prosthet Dent</sb:maintitle>
</sb:title>
<sb:volume-nr>50</sb:volume-nr>
</sb:series>
<sb:date>1983</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>374</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib12">
<ce:label>12.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Talgren</ce:surname>
<ce:given-name>A</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>The continuing reduction of the residual alveolar ridges in complete denture wearers. A mixed longitudinal study covering 25 years</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Prosthet Dent</sb:maintitle>
</sb:title>
<sb:volume-nr>27</sb:volume-nr>
</sb:series>
<sb:date>1972</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>120</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
<ce:bib-reference id="bib13">
<ce:label>13.</ce:label>
<sb:reference>
<sb:contribution>
<sb:authors>
<sb:author>
<ce:surname>Atwood</ce:surname>
<ce:given-name>DA</ce:given-name>
</sb:author>
</sb:authors>
<sb:title>
<sb:maintitle>A personal perspective of implant dentistry</sb:maintitle>
</sb:title>
</sb:contribution>
<sb:host>
<sb:issue>
<sb:series>
<sb:title>
<sb:maintitle>J Prosthet Dent</sb:maintitle>
</sb:title>
<sb:volume-nr>51</sb:volume-nr>
</sb:series>
<sb:date>1984</sb:date>
</sb:issue>
<sb:pages>
<sb:first-page>801</sb:first-page>
</sb:pages>
</sb:host>
</sb:reference>
</ce:bib-reference>
</ce:bibliography-sec>
</ce:bibliography>
</tail>
</article>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo lang="en">
<title>Clinical evaluation of ramus frame and staple bone implants</title>
</titleInfo>
<titleInfo type="alternative" lang="en" contentType="CDATA">
<title>Clinical evaluation of ramus frame and staple bone implants</title>
</titleInfo>
<name type="personal">
<namePart type="given">J.B.</namePart>
<namePart type="family">Meyer, Jr.</namePart>
<namePart type="termsOfAddress">D.M.D.</namePart>
<affiliation>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</affiliation>
<description>Reprint requests to:Dr. Jack B. Meyer, Jr. 6913Sharmel Ln. Columbus, GA 31904.</description>
<description>Major, DC, USA; Senior Resident, Removable Prosthodontic Residency Program.</description>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">K.R.</namePart>
<namePart type="family">Kotwal</namePart>
<namePart type="termsOfAddress">B.D.S., D.M.D., M.S.</namePart>
<affiliation>William Beaumont Army Medical Center, El Paso, Tex., U.S.A.</affiliation>
<description>Colonel, DC, USA; Director, Removable Prosthodontic Residency Program.</description>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="research-article" displayLabel="Full-length article" authority="ISTEX" authorityURI="https://content-type.data.istex.fr" valueURI="https://content-type.data.istex.fr/ark:/67375/XTP-1JC4F85T-7">research-article</genre>
<originInfo>
<publisher>ELSEVIER</publisher>
<dateIssued encoding="w3cdtf">1986</dateIssued>
<copyrightDate encoding="w3cdtf">1986</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
</language>
<abstract lang="en">Abstract: Atwood13 pointed out that “variability of human response (resistance to infection, susceptibility to bone resorption, and psychologic capacity) demands more basic research and clinical trials to improve success”. This study can serve as a baseline for further longitudinal studies and controlled clinical research. Barring tissue or systemic complications, the prosthodontist must take the responsibility through sound treatment principles and awareness to ensure continued satisfaction and success of these implant systems.</abstract>
<subject>
<genre>article-category</genre>
<topic>Maxillofacial prosthetics • dental implants</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>The Journal of Prosthetic Dentistry</title>
</titleInfo>
<titleInfo type="abbreviated">
<title>YMPR</title>
</titleInfo>
<genre type="journal" authority="ISTEX" authorityURI="https://publication-type.data.istex.fr" valueURI="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</genre>
<originInfo>
<publisher>ELSEVIER</publisher>
<dateIssued encoding="w3cdtf">198601</dateIssued>
</originInfo>
<identifier type="ISSN">0022-3913</identifier>
<identifier type="PII">S0022-3913(86)X8075-5</identifier>
<part>
<date>198601</date>
<detail type="volume">
<number>55</number>
<caption>vol.</caption>
</detail>
<detail type="issue">
<number>1</number>
<caption>no.</caption>
</detail>
<extent unit="issue-pages">
<start>A3</start>
<end>A24</end>
</extent>
<extent unit="issue-pages">
<start>1</start>
<end>156</end>
</extent>
<extent unit="issue-pages">
<start>A27</start>
<end>A30</end>
</extent>
<extent unit="pages">
<start>87</start>
<end>92</end>
</extent>
</part>
</relatedItem>
<identifier type="istex">1DD2FD74494B1BDD6661BDEB2923697082088CD7</identifier>
<identifier type="ark">ark:/67375/6H6-BM3RM852-6</identifier>
<identifier type="DOI">10.1016/0022-3913(86)90081-8</identifier>
<identifier type="PII">0022-3913(86)90081-8</identifier>
<identifier type="ArticleID">86900818</identifier>
<accessCondition type="use and reproduction" contentType="copyright">©1986 The C. V. Mosby Company</accessCondition>
<recordInfo>
<recordContentSource authority="ISTEX" authorityURI="https://loaded-corpus.data.istex.fr" valueURI="https://loaded-corpus.data.istex.fr/ark:/67375/XBH-HKKZVM7B-M">elsevier</recordContentSource>
<recordOrigin>The C. V. Mosby Company, ©1986</recordOrigin>
</recordInfo>
</mods>
<json:item>
<extension>json</extension>
<original>false</original>
<mimetype>application/json</mimetype>
<uri>https://api.istex.fr/document/1DD2FD74494B1BDD6661BDEB2923697082088CD7/metadata/json</uri>
</json:item>
</metadata>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E86 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 000E86 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:1DD2FD74494B1BDD6661BDEB2923697082088CD7
   |texte=   Clinical evaluation of ramus frame and staple bone implants
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022