Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility

Identifieur interne : 000677 ( Istex/Corpus ); précédent : 000676; suivant : 000678

Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility

Auteurs : Marco Del Corso ; Giancarlo Abà ; Lydia Vazquez ; Jacques Dargaud ; David M. Dohan Ehrenfest

Source :

RBID : ISTEX:0DFC4ADB96DE6CA6B2E9C929E5B4143161576633

English descriptors

Abstract

Purpose: Manufacturing complex prosthetic framework on osseointegrated implants requires precision at every step of execution. The purpose of this study was to verify the possibility of applying the technology of image acquisition to determine the spatial position of osseointegrated implants.

Url:
DOI: 10.1111/j.1708-8208.2008.00106.x

Links to Exploration step

ISTEX:0DFC4ADB96DE6CA6B2E9C929E5B4143161576633

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility</title>
<author>
<name sortKey="Del Corso, Marco" sort="Del Corso, Marco" uniqKey="Del Corso M" first="Marco" last="Del Corso">Marco Del Corso</name>
<affiliation>
<mods:affiliation>Lecturer, Department of Periodontology, Turin University, Turin, Italy;</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>researcher, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Aba, Giancarlo" sort="Aba, Giancarlo" uniqKey="Aba G" first="Giancarlo" last="Abà">Giancarlo Abà</name>
<affiliation>
<mods:affiliation>management consultant according to ISO 13485:2003 (quality standard of medical devices), and European Organization for Quality (EOQ) certified lead auditor;</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vazquez, Lydia" sort="Vazquez, Lydia" uniqKey="Vazquez L" first="Lydia" last="Vazquez">Lydia Vazquez</name>
<affiliation>
<mods:affiliation>assistant professor, Department of Oral Surgery, Oral Medicine, Oral and Maxillofacial Radiology, School of Dental Medicine, University of Geneva, Geneva, Switzerland;</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Dargaud, Jacques" sort="Dargaud, Jacques" uniqKey="Dargaud J" first="Jacques" last="Dargaud">Jacques Dargaud</name>
<affiliation>
<mods:affiliation>senior lecturer, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Ehrenfest, David M Dohan" sort="Ehrenfest, David M Dohan" uniqKey="Ehrenfest D" first="David M. Dohan" last="Ehrenfest">David M. Dohan Ehrenfest</name>
<affiliation>
<mods:affiliation>researcher, Department of Biomaterials/Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden, and The LoB5 Foundation for Research, AP‐HP Hospital Albert Chenevier, Créteil, France.</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: LoB5@mac.com</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:0DFC4ADB96DE6CA6B2E9C929E5B4143161576633</idno>
<date when="2009" year="2009">2009</date>
<idno type="doi">10.1111/j.1708-8208.2008.00106.x</idno>
<idno type="url">https://api.istex.fr/document/0DFC4ADB96DE6CA6B2E9C929E5B4143161576633/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000677</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000677</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility</title>
<author>
<name sortKey="Del Corso, Marco" sort="Del Corso, Marco" uniqKey="Del Corso M" first="Marco" last="Del Corso">Marco Del Corso</name>
<affiliation>
<mods:affiliation>Lecturer, Department of Periodontology, Turin University, Turin, Italy;</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>researcher, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Aba, Giancarlo" sort="Aba, Giancarlo" uniqKey="Aba G" first="Giancarlo" last="Abà">Giancarlo Abà</name>
<affiliation>
<mods:affiliation>management consultant according to ISO 13485:2003 (quality standard of medical devices), and European Organization for Quality (EOQ) certified lead auditor;</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vazquez, Lydia" sort="Vazquez, Lydia" uniqKey="Vazquez L" first="Lydia" last="Vazquez">Lydia Vazquez</name>
<affiliation>
<mods:affiliation>assistant professor, Department of Oral Surgery, Oral Medicine, Oral and Maxillofacial Radiology, School of Dental Medicine, University of Geneva, Geneva, Switzerland;</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Dargaud, Jacques" sort="Dargaud, Jacques" uniqKey="Dargaud J" first="Jacques" last="Dargaud">Jacques Dargaud</name>
<affiliation>
<mods:affiliation>senior lecturer, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Ehrenfest, David M Dohan" sort="Ehrenfest, David M Dohan" uniqKey="Ehrenfest D" first="David M. Dohan" last="Ehrenfest">David M. Dohan Ehrenfest</name>
<affiliation>
<mods:affiliation>researcher, Department of Biomaterials/Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden, and The LoB5 Foundation for Research, AP‐HP Hospital Albert Chenevier, Créteil, France.</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: LoB5@mac.com</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Implant Dentistry and Related Research</title>
<title level="j" type="alt">CLINICAL IMPLANT DENTISTRY RELATED RESEARCH</title>
<idno type="ISSN">1523-0899</idno>
<idno type="eISSN">1708-8208</idno>
<imprint>
<biblScope unit="vol">11</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="214">214</biblScope>
<biblScope unit="page" to="221">221</biblScope>
<biblScope unit="page-count">8</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2009-09">2009-09</date>
</imprint>
<idno type="ISSN">1523-0899</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1523-0899</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Active range camera</term>
<term>Anatomy laboratory</term>
<term>Angle vectors</term>
<term>Average values</term>
<term>Bias</term>
<term>Bias error</term>
<term>Bias error value</term>
<term>Bias value</term>
<term>Clin</term>
<term>Clin implant dent relat</term>
<term>Clinical implant dentistry</term>
<term>Clinical trial</term>
<term>Conventional impressions</term>
<term>Dohan ehrenfest</term>
<term>Edentulous</term>
<term>Fringe patterns light</term>
<term>Image acquisition</term>
<term>Implant</term>
<term>Implant analogues</term>
<term>Implant position</term>
<term>Jemt</term>
<term>Marker</term>
<term>Markers diameter</term>
<term>Master cast</term>
<term>Measurement process</term>
<term>Medicine faculty lyon claude bernard lyon</term>
<term>Optical scanning</term>
<term>Optical scanning acquisition</term>
<term>Optical scannings</term>
<term>Oral maxillofac implants</term>
<term>Osseointegrated</term>
<term>Osseointegrated implants</term>
<term>Photogrammetric measurements</term>
<term>Polar distances</term>
<term>Prosthesis</term>
<term>Prosthet dent</term>
<term>Prosthetic</term>
<term>Prosthetic framework</term>
<term>Reference values</term>
<term>Sahlgrenska academy</term>
<term>Scanner</term>
<term>Scanning</term>
<term>Scanning procedure</term>
<term>Space coordinates</term>
<term>Spatial position</term>
<term>Steinbichler optotechnik gmbh</term>
<term>Surgical sciences</term>
<term>Test conditions</term>
<term>Titanium</term>
<term>Titanium frameworks</term>
<term>True value</term>
<term>Vivo study</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Active range camera</term>
<term>Anatomy laboratory</term>
<term>Angle vectors</term>
<term>Average values</term>
<term>Bias</term>
<term>Bias error</term>
<term>Bias error value</term>
<term>Bias value</term>
<term>Clin</term>
<term>Clin implant dent relat</term>
<term>Clinical implant dentistry</term>
<term>Clinical trial</term>
<term>Conventional impressions</term>
<term>Dohan ehrenfest</term>
<term>Edentulous</term>
<term>Fringe patterns light</term>
<term>Image acquisition</term>
<term>Implant</term>
<term>Implant analogues</term>
<term>Implant position</term>
<term>Jemt</term>
<term>Marker</term>
<term>Markers diameter</term>
<term>Master cast</term>
<term>Measurement process</term>
<term>Medicine faculty lyon claude bernard lyon</term>
<term>Optical scanning</term>
<term>Optical scanning acquisition</term>
<term>Optical scannings</term>
<term>Oral maxillofac implants</term>
<term>Osseointegrated</term>
<term>Osseointegrated implants</term>
<term>Photogrammetric measurements</term>
<term>Polar distances</term>
<term>Prosthesis</term>
<term>Prosthet dent</term>
<term>Prosthetic</term>
<term>Prosthetic framework</term>
<term>Reference values</term>
<term>Sahlgrenska academy</term>
<term>Scanner</term>
<term>Scanning</term>
<term>Scanning procedure</term>
<term>Space coordinates</term>
<term>Spatial position</term>
<term>Steinbichler optotechnik gmbh</term>
<term>Surgical sciences</term>
<term>Test conditions</term>
<term>Titanium</term>
<term>Titanium frameworks</term>
<term>True value</term>
<term>Vivo study</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">Purpose: Manufacturing complex prosthetic framework on osseointegrated implants requires precision at every step of execution. The purpose of this study was to verify the possibility of applying the technology of image acquisition to determine the spatial position of osseointegrated implants.</div>
</front>
</TEI>
<istex>
<corpusName>wiley</corpusName>
<keywords>
<teeft>
<json:string>implant</json:string>
<json:string>jemt</json:string>
<json:string>prosthesis</json:string>
<json:string>osseointegrated</json:string>
<json:string>scanner</json:string>
<json:string>clin</json:string>
<json:string>prosthetic</json:string>
<json:string>osseointegrated implants</json:string>
<json:string>bias error</json:string>
<json:string>optical scanning acquisition</json:string>
<json:string>space coordinates</json:string>
<json:string>oral maxillofac implants</json:string>
<json:string>titanium frameworks</json:string>
<json:string>clin implant dent relat</json:string>
<json:string>optical scannings</json:string>
<json:string>master cast</json:string>
<json:string>bias value</json:string>
<json:string>angle vectors</json:string>
<json:string>scanning</json:string>
<json:string>edentulous</json:string>
<json:string>polar distances</json:string>
<json:string>reference values</json:string>
<json:string>optical scanning</json:string>
<json:string>scanning procedure</json:string>
<json:string>test conditions</json:string>
<json:string>average values</json:string>
<json:string>fringe patterns light</json:string>
<json:string>clinical implant dentistry</json:string>
<json:string>marker</json:string>
<json:string>dohan ehrenfest</json:string>
<json:string>steinbichler optotechnik gmbh</json:string>
<json:string>anatomy laboratory</json:string>
<json:string>medicine faculty lyon claude bernard lyon</json:string>
<json:string>surgical sciences</json:string>
<json:string>sahlgrenska academy</json:string>
<json:string>markers diameter</json:string>
<json:string>prosthet dent</json:string>
<json:string>prosthetic framework</json:string>
<json:string>image acquisition</json:string>
<json:string>spatial position</json:string>
<json:string>active range camera</json:string>
<json:string>conventional impressions</json:string>
<json:string>implant position</json:string>
<json:string>vivo study</json:string>
<json:string>bias error value</json:string>
<json:string>clinical trial</json:string>
<json:string>true value</json:string>
<json:string>photogrammetric measurements</json:string>
<json:string>implant analogues</json:string>
<json:string>measurement process</json:string>
<json:string>titanium</json:string>
<json:string>bias</json:string>
</teeft>
</keywords>
<author>
<json:item>
<name>Marco Del Corso DDS</name>
<affiliations>
<json:string>Lecturer, Department of Periodontology, Turin University, Turin, Italy;</json:string>
<json:string>researcher, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</json:string>
</affiliations>
</json:item>
<json:item>
<name>Giancarlo Abà</name>
<affiliations>
<json:string>management consultant according to ISO 13485:2003 (quality standard of medical devices), and European Organization for Quality (EOQ) certified lead auditor;</json:string>
</affiliations>
</json:item>
<json:item>
<name>Lydia Vazquez MD, DDS, PhD</name>
<affiliations>
<json:string>assistant professor, Department of Oral Surgery, Oral Medicine, Oral and Maxillofacial Radiology, School of Dental Medicine, University of Geneva, Geneva, Switzerland;</json:string>
</affiliations>
</json:item>
<json:item>
<name>Jacques Dargaud DDS, MS</name>
<affiliations>
<json:string>senior lecturer, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</json:string>
</affiliations>
</json:item>
<json:item>
<name>David M. Dohan Ehrenfest DDS, MS, PhD</name>
<affiliations>
<json:string>researcher, Department of Biomaterials/Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden, and The LoB5 Foundation for Research, AP‐HP Hospital Albert Chenevier, Créteil, France.</json:string>
<json:string>E-mail: LoB5@mac.com</json:string>
</affiliations>
</json:item>
</author>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>bias</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>dental implants</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>fringe patterns light</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>optical measurements</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>structured light</value>
</json:item>
</subject>
<articleId>
<json:string>CID106</json:string>
</articleId>
<arkIstex>ark:/67375/WNG-VHJW95G8-H</arkIstex>
<language>
<json:string>eng</json:string>
</language>
<originalGenre>
<json:string>article</json:string>
</originalGenre>
<abstract>Purpose: Manufacturing complex prosthetic framework on osseointegrated implants requires precision at every step of execution. The purpose of this study was to verify the possibility of applying the technology of image acquisition to determine the spatial position of osseointegrated implants.</abstract>
<qualityIndicators>
<refBibsNative>true</refBibsNative>
<abstractWordCount>40</abstractWordCount>
<abstractCharCount>293</abstractCharCount>
<keywordCount>5</keywordCount>
<score>5.454</score>
<pdfWordCount>2974</pdfWordCount>
<pdfCharCount>20736</pdfCharCount>
<pdfVersion>1.3</pdfVersion>
<pdfPageCount>8</pdfPageCount>
<pdfPageSize>585 x 783 pts</pdfPageSize>
</qualityIndicators>
<title>Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility</title>
<pmid>
<json:string>18657149</json:string>
</pmid>
<genre>
<json:string>article</json:string>
</genre>
<host>
<title>Clinical Implant Dentistry and Related Research</title>
<language>
<json:string>unknown</json:string>
</language>
<doi>
<json:string>10.1111/(ISSN)1708-8208</json:string>
</doi>
<issn>
<json:string>1523-0899</json:string>
</issn>
<eissn>
<json:string>1708-8208</json:string>
</eissn>
<publisherId>
<json:string>CID</json:string>
</publisherId>
<volume>11</volume>
<issue>3</issue>
<pages>
<first>214</first>
<last>221</last>
<total>8</total>
</pages>
<genre>
<json:string>journal</json:string>
</genre>
</host>
<namedEntities>
<unitex>
<date>
<json:string>2009</json:string>
</date>
<geogName></geogName>
<orgName>
<json:string>Wiley Periodicals, Inc.</json:string>
<json:string>Department of Biomaterials and Handicap</json:string>
<json:string>Department of Biomaterials/Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden</json:string>
<json:string>Related Research, Volume</json:string>
<json:string>Anatomy Laboratory, Medicine Faculty Lyon Grange-Blanche, Claude Bernard Lyon</json:string>
<json:string>Department of Oral Surgery, Oral Medicine, Oral and Maxillofacial Radiology</json:string>
<json:string>EOQ</json:string>
<json:string>HP Hospital Albert Chenevier, Créteil, France</json:string>
<json:string>Foundation for Research, AP</json:string>
<json:string>Göteborg University</json:string>
<json:string>University of Geneva</json:string>
</orgName>
<orgName_funder></orgName_funder>
<orgName_provider></orgName_provider>
<persName>
<json:string>Error Measured</json:string>
<json:string>Carl Zeiss</json:string>
<json:string>Giancarlo Abà</json:string>
<json:string>Jacques Dargaud</json:string>
<json:string>David M. Dohan</json:string>
<json:string>Error Referred</json:string>
<json:string>Taylor Hobson</json:string>
<json:string>Lydia Vazquez</json:string>
<json:string>Luca Amerio</json:string>
</persName>
<placeName>
<json:string>Geneva</json:string>
<json:string>Switzerland</json:string>
<json:string>Germany</json:string>
<json:string>Palm Beach</json:string>
<json:string>France</json:string>
<json:string>Sweden</json:string>
<json:string>Lyon</json:string>
</placeName>
<ref_url></ref_url>
<ref_bibl></ref_bibl>
<bibl></bibl>
</unitex>
</namedEntities>
<ark>
<json:string>ark:/67375/WNG-VHJW95G8-H</json:string>
</ark>
<categories>
<wos>
<json:string>1 - science</json:string>
<json:string>2 - dentistry, oral surgery & medicine</json:string>
</wos>
<scienceMetrix>
<json:string>1 - health sciences</json:string>
<json:string>2 - clinical medicine</json:string>
<json:string>3 - dentistry</json:string>
</scienceMetrix>
<scopus>
<json:string>1 - Health Sciences</json:string>
<json:string>2 - Dentistry</json:string>
<json:string>3 - General Dentistry</json:string>
<json:string>1 - Health Sciences</json:string>
<json:string>2 - Dentistry</json:string>
<json:string>3 - Oral Surgery</json:string>
</scopus>
</categories>
<publicationDate>2009</publicationDate>
<copyrightDate>2009</copyrightDate>
<doi>
<json:string>10.1111/j.1708-8208.2008.00106.x</json:string>
</doi>
<id>0DFC4ADB96DE6CA6B2E9C929E5B4143161576633</id>
<score>1</score>
<fulltext>
<json:item>
<extension>pdf</extension>
<original>true</original>
<mimetype>application/pdf</mimetype>
<uri>https://api.istex.fr/document/0DFC4ADB96DE6CA6B2E9C929E5B4143161576633/fulltext/pdf</uri>
</json:item>
<json:item>
<extension>zip</extension>
<original>false</original>
<mimetype>application/zip</mimetype>
<uri>https://api.istex.fr/document/0DFC4ADB96DE6CA6B2E9C929E5B4143161576633/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/0DFC4ADB96DE6CA6B2E9C929E5B4143161576633/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a" type="main">Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<availability>
<licence>© 2008, Copyright the Authors. Journal Compilation © 2008, Wiley Periodicals, Inc.</licence>
</availability>
<date type="published" when="2009-09"></date>
</publicationStmt>
<notesStmt>
<note type="content-type" subtype="article" source="article" scheme="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</note>
<note type="publication-type" subtype="journal" scheme="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</note>
</notesStmt>
<sourceDesc>
<biblStruct type="article">
<analytic>
<title level="a" type="main">Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility</title>
<title level="a" type="short">Optical Three‐Dimensional Scanning Acquisition of Osseointegrated Implants</title>
<author xml:id="author-0000">
<persName>
<forename type="first">Marco</forename>
<surname>Del Corso</surname>
<roleName type="degree">DDS</roleName>
</persName>
<affiliation>Lecturer, Department of Periodontology, Turin University, Turin, Italy;
<address>
<country key="IT"></country>
</address>
</affiliation>
<affiliation>researcher, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;
<address>
<country key="FR"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0001">
<persName>
<forename type="first">Giancarlo</forename>
<surname>Abà</surname>
</persName>
<affiliation>management consultant according to ISO 13485:2003 (quality standard of medical devices), and European Organization for Quality (EOQ) certified lead auditor;</affiliation>
</author>
<author xml:id="author-0002">
<persName>
<forename type="first">Lydia</forename>
<surname>Vazquez</surname>
<roleName type="degree">MD, DDS, PhD</roleName>
</persName>
<affiliation>assistant professor, Department of Oral Surgery, Oral Medicine, Oral and Maxillofacial Radiology, School of Dental Medicine, University of Geneva, Geneva, Switzerland;
<address>
<country key="CH"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0003">
<persName>
<forename type="first">Jacques</forename>
<surname>Dargaud</surname>
<roleName type="degree">DDS, MS</roleName>
</persName>
<affiliation>senior lecturer, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;
<address>
<country key="FR"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0004" role="corresp">
<persName>
<forename type="first">David M. Dohan</forename>
<surname>Ehrenfest</surname>
<roleName type="degree">DDS, MS, PhD</roleName>
</persName>
<affiliation>researcher, Department of Biomaterials/Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden, and The LoB5 Foundation for Research, AP‐HP Hospital Albert Chenevier, Créteil, France.</affiliation>
<affiliation>David M. Dohan Ehrenfest, DDS, MS, PhD, Department of Biomaterials and Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Medicinaregatan 8B, 41390 Göteborg, Sweden; e‐mail: LoB5@mac.com</affiliation>
</author>
<idno type="istex">0DFC4ADB96DE6CA6B2E9C929E5B4143161576633</idno>
<idno type="ark">ark:/67375/WNG-VHJW95G8-H</idno>
<idno type="DOI">10.1111/j.1708-8208.2008.00106.x</idno>
<idno type="unit">CID106</idno>
<idno type="toTypesetVersion">file:CID.CID106.pdf</idno>
</analytic>
<monogr>
<title level="j" type="main">Clinical Implant Dentistry and Related Research</title>
<title level="j" type="alt">CLINICAL IMPLANT DENTISTRY RELATED RESEARCH</title>
<idno type="pISSN">1523-0899</idno>
<idno type="eISSN">1708-8208</idno>
<idno type="book-DOI">10.1111/(ISSN)1708-8208</idno>
<idno type="book-part-DOI">10.1111/cid.2009.11.issue-3</idno>
<idno type="product">CID</idno>
<idno type="publisherDivision">ST</idno>
<imprint>
<biblScope unit="vol">11</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="214">214</biblScope>
<biblScope unit="page" to="221">221</biblScope>
<biblScope unit="page-count">8</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2009-09"></date>
</imprint>
</monogr>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<abstract xml:lang="en" style="main">
<head>ABSTRACT</head>
<p>
<hi rend="bold">Purpose:</hi>
Manufacturing complex prosthetic framework on osseointegrated implants requires precision at every step of execution. The purpose of this study was to verify the possibility of applying the technology of image acquisition to determine the spatial position of osseointegrated implants.</p>
<p>
<hi rend="bold">Materials and Methods:</hi>
An optical three‐dimensional scanning technique was employed: its measurement systematic error (bias) was calculated by comparing the results with the detection on a coordinates measuring machine. Measurements were carried out on master casts by doing an in vitro simulation of intraoral conditions.</p>
<p>
<hi rend="bold">Result:</hi>
This study showed that the bias error value of the three‐dimensional optical acquiring system was situated between 14 and 21 µm.</p>
<p>
<hi rend="bold">Conclusion:</hi>
As far as the accuracy is concerned, it seems possible to use the three‐dimensional image acquisition technology as a valid alternative to traditional impression‐making procedures. However, the bias levels obtained in this in vitro study will have to be confirmed in a clinical trial.</p>
</abstract>
<textClass>
<keywords xml:lang="en">
<term xml:id="k1">bias</term>
<term xml:id="k2">dental implants</term>
<term xml:id="k3">fringe patterns light</term>
<term xml:id="k4">optical measurements</term>
<term xml:id="k5">structured light</term>
</keywords>
<keywords rend="tocHeading1">
<term>ARTICLES</term>
</keywords>
</textClass>
<langUsage>
<language ident="en"></language>
</langUsage>
</profileDesc>
</teiHeader>
</istex:fulltextTEI>
<json:item>
<extension>txt</extension>
<original>false</original>
<mimetype>text/plain</mimetype>
<uri>https://api.istex.fr/document/0DFC4ADB96DE6CA6B2E9C929E5B4143161576633/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Wiley, elements deleted: body">
<istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document>
<component version="2.0" type="serialArticle" xml:lang="en">
<header>
<publicationMeta level="product">
<publisherInfo>
<publisherName>Blackwell Publishing Ltd</publisherName>
<publisherLoc>Oxford, UK</publisherLoc>
</publisherInfo>
<doi origin="wiley" registered="yes">10.1111/(ISSN)1708-8208</doi>
<issn type="print">1523-0899</issn>
<issn type="electronic">1708-8208</issn>
<idGroup>
<id type="product" value="CID"></id>
<id type="publisherDivision" value="ST"></id>
</idGroup>
<titleGroup>
<title type="main" sort="CLINICAL IMPLANT DENTISTRY RELATED RESEARCH">Clinical Implant Dentistry and Related Research</title>
</titleGroup>
</publicationMeta>
<publicationMeta level="part" position="09003">
<doi origin="wiley">10.1111/cid.2009.11.issue-3</doi>
<numberingGroup>
<numbering type="journalVolume" number="11">11</numbering>
<numbering type="journalIssue" number="3">3</numbering>
</numberingGroup>
<coverDate startDate="2009-09">September 2009</coverDate>
</publicationMeta>
<publicationMeta level="unit" type="article" position="6" status="forIssue">
<doi origin="wiley">10.1111/j.1708-8208.2008.00106.x</doi>
<idGroup>
<id type="unit" value="CID106"></id>
</idGroup>
<countGroup>
<count type="pageTotal" number="8"></count>
</countGroup>
<titleGroup>
<title type="tocHeading1">ARTICLES</title>
</titleGroup>
<copyright>© 2008, Copyright the Authors. Journal Compilation © 2008, Wiley Periodicals, Inc.</copyright>
<eventGroup>
<event type="firstOnline" date="2008-07-24"></event>
<event type="publishedOnlineFinalForm" date="2009-08-10"></event>
<event type="xmlConverted" agent="Converter:BPG_TO_WML3G version:2.3.4 mode:FullText source:FullText result:FullText" date="2010-03-30"></event>
<event type="xmlConverted" agent="Converter:WILEY_ML3G_TO_WILEY_ML3GV2 version:3.8.8" date="2014-01-15"></event>
<event type="xmlConverted" agent="Converter:WML3G_To_WML3G version:4.1.7 mode:FullText,remove_FC" date="2014-10-16"></event>
</eventGroup>
<numberingGroup>
<numbering type="pageFirst" number="214">214</numbering>
<numbering type="pageLast" number="221">221</numbering>
</numberingGroup>
<correspondenceTo>David M. Dohan Ehrenfest, DDS, MS, PhD, Department of Biomaterials and Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Medicinaregatan 8B, 41390 Göteborg, Sweden; e‐mail:
<email>LoB5@mac.com</email>
</correspondenceTo>
<linkGroup>
<link type="toTypesetVersion" href="file:CID.CID106.pdf"></link>
</linkGroup>
</publicationMeta>
<contentMeta>
<countGroup>
<count type="figureTotal" number="6"></count>
<count type="tableTotal" number="4"></count>
<count type="formulaTotal" number="0"></count>
<count type="referenceTotal" number="21"></count>
<count type="wordTotal" number="3770"></count>
<count type="linksPubMed" number="0"></count>
<count type="linksCrossRef" number="0"></count>
</countGroup>
<titleGroup>
<title type="main">Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility</title>
<title type="shortAuthors">Clinical Implant Dentistry and Related Research, Volume *, Number *, 2008</title>
<title type="short">Optical Three‐Dimensional Scanning Acquisition of Osseointegrated Implants</title>
</titleGroup>
<creators>
<creator creatorRole="author" xml:id="cr1" affiliationRef="#a1 #a2">
<personName>
<givenNames>Marco</givenNames>
<familyName>Del Corso</familyName>
<degrees>DDS</degrees>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr2" affiliationRef="#a3">
<personName>
<givenNames>Giancarlo</givenNames>
<familyName>Abà</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr3" affiliationRef="#a4">
<personName>
<givenNames>Lydia</givenNames>
<familyName>Vazquez</familyName>
<degrees>MD, DDS, PhD</degrees>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr4" affiliationRef="#a5">
<personName>
<givenNames>Jacques</givenNames>
<familyName>Dargaud</familyName>
<degrees>DDS, MS</degrees>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr5" affiliationRef="#a6" corresponding="yes">
<personName>
<givenNames>David M. Dohan</givenNames>
<familyName>Ehrenfest</familyName>
<degrees>DDS, MS, PhD</degrees>
</personName>
</creator>
</creators>
<affiliationGroup>
<affiliation xml:id="a1" countryCode="IT">
<unparsedAffiliation>Lecturer, Department of Periodontology, Turin University, Turin, Italy;</unparsedAffiliation>
</affiliation>
<affiliation xml:id="a2" countryCode="FR">
<unparsedAffiliation>researcher, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</unparsedAffiliation>
</affiliation>
<affiliation xml:id="a3">
<unparsedAffiliation>management consultant according to ISO 13485:2003 (quality standard of medical devices), and European Organization for Quality (EOQ) certified lead auditor;</unparsedAffiliation>
</affiliation>
<affiliation xml:id="a4" countryCode="CH">
<unparsedAffiliation>assistant professor, Department of Oral Surgery, Oral Medicine, Oral and Maxillofacial Radiology, School of Dental Medicine, University of Geneva, Geneva, Switzerland;</unparsedAffiliation>
</affiliation>
<affiliation xml:id="a5" countryCode="FR">
<unparsedAffiliation>senior lecturer, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</unparsedAffiliation>
</affiliation>
<affiliation xml:id="a6">
<unparsedAffiliation>researcher, Department of Biomaterials/Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden, and The LoB5 Foundation for Research, AP‐HP Hospital Albert Chenevier, Créteil, France.</unparsedAffiliation>
</affiliation>
</affiliationGroup>
<keywordGroup xml:lang="en">
<keyword xml:id="k1">bias</keyword>
<keyword xml:id="k2">dental implants</keyword>
<keyword xml:id="k3">fringe patterns light</keyword>
<keyword xml:id="k4">optical measurements</keyword>
<keyword xml:id="k5">structured light</keyword>
</keywordGroup>
<abstractGroup>
<abstract type="main" xml:lang="en">
<title type="main">ABSTRACT</title>
<p>
<b>Purpose:</b>
Manufacturing complex prosthetic framework on osseointegrated implants requires precision at every step of execution. The purpose of this study was to verify the possibility of applying the technology of image acquisition to determine the spatial position of osseointegrated implants.</p>
<p>
<b>Materials and Methods:</b>
An optical three‐dimensional scanning technique was employed: its measurement systematic error (bias) was calculated by comparing the results with the detection on a coordinates measuring machine. Measurements were carried out on master casts by doing an in vitro simulation of intraoral conditions.</p>
<p>
<b>Result:</b>
This study showed that the bias error value of the three‐dimensional optical acquiring system was situated between 14 and 21 µm.</p>
<p>
<b>Conclusion:</b>
As far as the accuracy is concerned, it seems possible to use the three‐dimensional image acquisition technology as a valid alternative to traditional impression‐making procedures. However, the bias levels obtained in this in vitro study will have to be confirmed in a clinical trial.</p>
</abstract>
</abstractGroup>
</contentMeta>
</header>
</component>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo lang="en">
<title>Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility</title>
</titleInfo>
<titleInfo type="abbreviated" lang="en">
<title>Optical Three‐Dimensional Scanning Acquisition of Osseointegrated Implants</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en">
<title>Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility</title>
</titleInfo>
<name type="personal">
<namePart type="given">Marco</namePart>
<namePart type="family">Del Corso</namePart>
<namePart type="termsOfAddress">DDS</namePart>
<affiliation>Lecturer, Department of Periodontology, Turin University, Turin, Italy;</affiliation>
<affiliation>researcher, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Giancarlo</namePart>
<namePart type="family">Abà</namePart>
<affiliation>management consultant according to ISO 13485:2003 (quality standard of medical devices), and European Organization for Quality (EOQ) certified lead auditor;</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Lydia</namePart>
<namePart type="family">Vazquez</namePart>
<namePart type="termsOfAddress">MD, DDS, PhD</namePart>
<affiliation>assistant professor, Department of Oral Surgery, Oral Medicine, Oral and Maxillofacial Radiology, School of Dental Medicine, University of Geneva, Geneva, Switzerland;</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Jacques</namePart>
<namePart type="family">Dargaud</namePart>
<namePart type="termsOfAddress">DDS, MS</namePart>
<affiliation>senior lecturer, Anatomy Laboratory, Medicine Faculty Lyon Grange‐Blanche, Claude Bernard Lyon 1 University, Lyon, France;</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">David M. Dohan</namePart>
<namePart type="family">Ehrenfest</namePart>
<namePart type="termsOfAddress">DDS, MS, PhD</namePart>
<affiliation>researcher, Department of Biomaterials/Handicap Research, Institute of Surgical Sciences, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden, and The LoB5 Foundation for Research, AP‐HP Hospital Albert Chenevier, Créteil, France.</affiliation>
<affiliation>E-mail: LoB5@mac.com</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="article" displayLabel="article" authority="ISTEX" authorityURI="https://content-type.data.istex.fr" valueURI="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</genre>
<originInfo>
<publisher>Blackwell Publishing Ltd</publisher>
<place>
<placeTerm type="text">Oxford, UK</placeTerm>
</place>
<dateIssued encoding="w3cdtf">2009-09</dateIssued>
<copyrightDate encoding="w3cdtf">2009</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<extent unit="figures">6</extent>
<extent unit="tables">4</extent>
<extent unit="formulas">0</extent>
<extent unit="references">21</extent>
<extent unit="linksCrossRef">0</extent>
<extent unit="words">3770</extent>
</physicalDescription>
<abstract>Purpose: Manufacturing complex prosthetic framework on osseointegrated implants requires precision at every step of execution. The purpose of this study was to verify the possibility of applying the technology of image acquisition to determine the spatial position of osseointegrated implants.</abstract>
<abstract>Materials and Methods: An optical three‐dimensional scanning technique was employed: its measurement systematic error (bias) was calculated by comparing the results with the detection on a coordinates measuring machine. Measurements were carried out on master casts by doing an in vitro simulation of intraoral conditions.</abstract>
<abstract>Result: This study showed that the bias error value of the three‐dimensional optical acquiring system was situated between 14 and 21 µm.</abstract>
<abstract>Conclusion: As far as the accuracy is concerned, it seems possible to use the three‐dimensional image acquisition technology as a valid alternative to traditional impression‐making procedures. However, the bias levels obtained in this in vitro study will have to be confirmed in a clinical trial.</abstract>
<subject lang="en">
<genre>keywords</genre>
<topic>bias</topic>
<topic>dental implants</topic>
<topic>fringe patterns light</topic>
<topic>optical measurements</topic>
<topic>structured light</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>Clinical Implant Dentistry and Related Research</title>
</titleInfo>
<genre type="journal" authority="ISTEX" authorityURI="https://publication-type.data.istex.fr" valueURI="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</genre>
<identifier type="ISSN">1523-0899</identifier>
<identifier type="eISSN">1708-8208</identifier>
<identifier type="DOI">10.1111/(ISSN)1708-8208</identifier>
<identifier type="PublisherID">CID</identifier>
<part>
<date>2009</date>
<detail type="volume">
<caption>vol.</caption>
<number>11</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>3</number>
</detail>
<extent unit="pages">
<start>214</start>
<end>221</end>
<total>8</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">0DFC4ADB96DE6CA6B2E9C929E5B4143161576633</identifier>
<identifier type="ark">ark:/67375/WNG-VHJW95G8-H</identifier>
<identifier type="DOI">10.1111/j.1708-8208.2008.00106.x</identifier>
<identifier type="ArticleID">CID106</identifier>
<accessCondition type="use and reproduction" contentType="copyright">© 2008, Copyright the Authors. Journal Compilation © 2008, Wiley Periodicals, Inc.</accessCondition>
<recordInfo>
<recordContentSource authority="ISTEX" authorityURI="https://loaded-corpus.data.istex.fr" valueURI="https://loaded-corpus.data.istex.fr/ark:/67375/XBH-L0C46X92-X">wiley</recordContentSource>
<recordOrigin>Blackwell Publishing Ltd</recordOrigin>
</recordInfo>
</mods>
<json:item>
<extension>json</extension>
<original>false</original>
<mimetype>application/json</mimetype>
<uri>https://api.istex.fr/document/0DFC4ADB96DE6CA6B2E9C929E5B4143161576633/metadata/json</uri>
</json:item>
</metadata>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000677 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 000677 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:0DFC4ADB96DE6CA6B2E9C929E5B4143161576633
   |texte=   Optical Three‐Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022