A comparative in vitro evaluation of two different magnetic devices detecting the stability of osseo‐integrated implants
Identifieur interne : 001273 ( Istex/Checkpoint ); précédent : 001272; suivant : 001274A comparative in vitro evaluation of two different magnetic devices detecting the stability of osseo‐integrated implants
Auteurs : O. Geckili [Turquie] ; H. Bilhan [Turquie] ; A. Cilingir [Turquie] ; E. Mumcu [Turquie] ; C. Bural [Turquie]Source :
- Journal of Periodontal Research [ 0022-3484 ] ; 2012-08.
English descriptors
- KwdEn :
- Analyser, Buccal, Buccal isqs, Buccal mesial, Buccal recordings, Clinical situations, Clinical studies, Clinical study, Clinical success, Clinical trial, Dental implant, Dental implant stability, Electric voltage, Geckili, Greater interexaminer variability, Human mandibles, Implant, Implant contact, Implant dentistry, Implant stability, Implant stability measurements, Implant stability quotient, Insertion torque, Integration diagnostics, Interobserver, Interobserver reliability, Intraclass correlation, Istanbul university, Macroscopic composition, Magnetic devices, Magnetic resonance frequency analysers, Magnetic technology, Medullar bone, Mentor, Mesial, Mesial isqs, Nger pressure, Oral maxillofac implants, Oral maxillofac surg, Oral rehabil, Original osstell, Osseointegrated, Osseointegrated implants, Osstell, Osstell mentor, Plastic driver, Plastic screwdriver, Present study, Primary stability, Reliability, Resonance frequency, Resonance frequency analysis, Resonance frequency analysis measurements, Resonance frequency values, Rib, Same clinician, Same manufacturer, Sennerby, Smartpeg, Stability measurement devices, Standard drilling protocol, Surgical technique.
- Teeft :
- Analyser, Buccal, Buccal isqs, Buccal mesial, Buccal recordings, Clinical situations, Clinical studies, Clinical study, Clinical success, Clinical trial, Dental implant, Dental implant stability, Electric voltage, Geckili, Greater interexaminer variability, Human mandibles, Implant, Implant contact, Implant dentistry, Implant stability, Implant stability measurements, Implant stability quotient, Insertion torque, Integration diagnostics, Interobserver, Interobserver reliability, Intraclass correlation, Istanbul university, Macroscopic composition, Magnetic devices, Magnetic resonance frequency analysers, Magnetic technology, Medullar bone, Mentor, Mesial, Mesial isqs, Nger pressure, Oral maxillofac implants, Oral maxillofac surg, Oral rehabil, Original osstell, Osseointegrated, Osseointegrated implants, Osstell, Osstell mentor, Plastic driver, Plastic screwdriver, Present study, Primary stability, Reliability, Resonance frequency, Resonance frequency analysis, Resonance frequency analysis measurements, Resonance frequency values, Rib, Same clinician, Same manufacturer, Sennerby, Smartpeg, Stability measurement devices, Standard drilling protocol, Surgical technique.
Abstract
Geckili O, Bilhan H, Cilingir A, Mumcu E, Bural C. A comparative in vitro evaluation of two different magnetic devices detecting the stability of osseo‐integrated implants. J Periodont Res 2012; 47: 508–513. © 2012 John Wiley & Sons A/S
Url:
DOI: 10.1111/j.1600-0765.2011.01462.x
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
ISTEX:59B0D50673DED641B570AAD091BCC69C0CD4FA84Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">A comparative in vitro evaluation of two different magnetic devices detecting the stability of osseo‐integrated implants</title>
<author><name sortKey="Geckili, O" sort="Geckili, O" uniqKey="Geckili O" first="O." last="Geckili">O. Geckili</name>
</author>
<author><name sortKey="Bilhan, H" sort="Bilhan, H" uniqKey="Bilhan H" first="H." last="Bilhan">H. Bilhan</name>
</author>
<author><name sortKey="Cilingir, A" sort="Cilingir, A" uniqKey="Cilingir A" first="A." last="Cilingir">A. Cilingir</name>
</author>
<author><name sortKey="Mumcu, E" sort="Mumcu, E" uniqKey="Mumcu E" first="E." last="Mumcu">E. Mumcu</name>
</author>
<author><name sortKey="Bural, C" sort="Bural, C" uniqKey="Bural C" first="C." last="Bural">C. Bural</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:59B0D50673DED641B570AAD091BCC69C0CD4FA84</idno>
<date when="2012" year="2012">2012</date>
<idno type="doi">10.1111/j.1600-0765.2011.01462.x</idno>
<idno type="url">https://api.istex.fr/document/59B0D50673DED641B570AAD091BCC69C0CD4FA84/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002C12</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">002C12</idno>
<idno type="wicri:Area/Istex/Curation">002C12</idno>
<idno type="wicri:Area/Istex/Checkpoint">001273</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001273</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">A comparative <hi rend="italic">in vitro</hi>
evaluation of two different magnetic devices detecting the stability of osseo‐integrated implants</title>
<author><name sortKey="Geckili, O" sort="Geckili, O" uniqKey="Geckili O" first="O." last="Geckili">O. Geckili</name>
<affiliation wicri:level="1"><country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Bilhan, H" sort="Bilhan, H" uniqKey="Bilhan H" first="H." last="Bilhan">H. Bilhan</name>
<affiliation wicri:level="1"><country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Cilingir, A" sort="Cilingir, A" uniqKey="Cilingir A" first="A." last="Cilingir">A. Cilingir</name>
<affiliation wicri:level="1"><country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Mumcu, E" sort="Mumcu, E" uniqKey="Mumcu E" first="E." last="Mumcu">E. Mumcu</name>
<affiliation wicri:level="1"><country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Bural, C" sort="Bural, C" uniqKey="Bural C" first="C." last="Bural">C. Bural</name>
<affiliation wicri:level="1"><country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Journal of Periodontal Research</title>
<title level="j" type="alt">JOURNAL OF PERIODONTAL RESEARCH</title>
<idno type="ISSN">0022-3484</idno>
<idno type="eISSN">1600-0765</idno>
<imprint><biblScope unit="vol">47</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="508">508</biblScope>
<biblScope unit="page" to="513">513</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2012-08">2012-08</date>
</imprint>
<idno type="ISSN">0022-3484</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0022-3484</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Analyser</term>
<term>Buccal</term>
<term>Buccal isqs</term>
<term>Buccal mesial</term>
<term>Buccal recordings</term>
<term>Clinical situations</term>
<term>Clinical studies</term>
<term>Clinical study</term>
<term>Clinical success</term>
<term>Clinical trial</term>
<term>Dental implant</term>
<term>Dental implant stability</term>
<term>Electric voltage</term>
<term>Geckili</term>
<term>Greater interexaminer variability</term>
<term>Human mandibles</term>
<term>Implant</term>
<term>Implant contact</term>
<term>Implant dentistry</term>
<term>Implant stability</term>
<term>Implant stability measurements</term>
<term>Implant stability quotient</term>
<term>Insertion torque</term>
<term>Integration diagnostics</term>
<term>Interobserver</term>
<term>Interobserver reliability</term>
<term>Intraclass correlation</term>
<term>Istanbul university</term>
<term>Macroscopic composition</term>
<term>Magnetic devices</term>
<term>Magnetic resonance frequency analysers</term>
<term>Magnetic technology</term>
<term>Medullar bone</term>
<term>Mentor</term>
<term>Mesial</term>
<term>Mesial isqs</term>
<term>Nger pressure</term>
<term>Oral maxillofac implants</term>
<term>Oral maxillofac surg</term>
<term>Oral rehabil</term>
<term>Original osstell</term>
<term>Osseointegrated</term>
<term>Osseointegrated implants</term>
<term>Osstell</term>
<term>Osstell mentor</term>
<term>Plastic driver</term>
<term>Plastic screwdriver</term>
<term>Present study</term>
<term>Primary stability</term>
<term>Reliability</term>
<term>Resonance frequency</term>
<term>Resonance frequency analysis</term>
<term>Resonance frequency analysis measurements</term>
<term>Resonance frequency values</term>
<term>Rib</term>
<term>Same clinician</term>
<term>Same manufacturer</term>
<term>Sennerby</term>
<term>Smartpeg</term>
<term>Stability measurement devices</term>
<term>Standard drilling protocol</term>
<term>Surgical technique</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Analyser</term>
<term>Buccal</term>
<term>Buccal isqs</term>
<term>Buccal mesial</term>
<term>Buccal recordings</term>
<term>Clinical situations</term>
<term>Clinical studies</term>
<term>Clinical study</term>
<term>Clinical success</term>
<term>Clinical trial</term>
<term>Dental implant</term>
<term>Dental implant stability</term>
<term>Electric voltage</term>
<term>Geckili</term>
<term>Greater interexaminer variability</term>
<term>Human mandibles</term>
<term>Implant</term>
<term>Implant contact</term>
<term>Implant dentistry</term>
<term>Implant stability</term>
<term>Implant stability measurements</term>
<term>Implant stability quotient</term>
<term>Insertion torque</term>
<term>Integration diagnostics</term>
<term>Interobserver</term>
<term>Interobserver reliability</term>
<term>Intraclass correlation</term>
<term>Istanbul university</term>
<term>Macroscopic composition</term>
<term>Magnetic devices</term>
<term>Magnetic resonance frequency analysers</term>
<term>Magnetic technology</term>
<term>Medullar bone</term>
<term>Mentor</term>
<term>Mesial</term>
<term>Mesial isqs</term>
<term>Nger pressure</term>
<term>Oral maxillofac implants</term>
<term>Oral maxillofac surg</term>
<term>Oral rehabil</term>
<term>Original osstell</term>
<term>Osseointegrated</term>
<term>Osseointegrated implants</term>
<term>Osstell</term>
<term>Osstell mentor</term>
<term>Plastic driver</term>
<term>Plastic screwdriver</term>
<term>Present study</term>
<term>Primary stability</term>
<term>Reliability</term>
<term>Resonance frequency</term>
<term>Resonance frequency analysis</term>
<term>Resonance frequency analysis measurements</term>
<term>Resonance frequency values</term>
<term>Rib</term>
<term>Same clinician</term>
<term>Same manufacturer</term>
<term>Sennerby</term>
<term>Smartpeg</term>
<term>Stability measurement devices</term>
<term>Standard drilling protocol</term>
<term>Surgical technique</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">Geckili O, Bilhan H, Cilingir A, Mumcu E, Bural C. A comparative in vitro evaluation of two different magnetic devices detecting the stability of osseo‐integrated implants. J Periodont Res 2012; 47: 508–513. © 2012 John Wiley & Sons A/S</div>
</front>
</TEI>
<affiliations><list><country><li>Turquie</li>
</country>
</list>
<tree><country name="Turquie"><noRegion><name sortKey="Geckili, O" sort="Geckili, O" uniqKey="Geckili O" first="O." last="Geckili">O. Geckili</name>
</noRegion>
<name sortKey="Bilhan, H" sort="Bilhan, H" uniqKey="Bilhan H" first="H." last="Bilhan">H. Bilhan</name>
<name sortKey="Bural, C" sort="Bural, C" uniqKey="Bural C" first="C." last="Bural">C. Bural</name>
<name sortKey="Cilingir, A" sort="Cilingir, A" uniqKey="Cilingir A" first="A." last="Cilingir">A. Cilingir</name>
<name sortKey="Mumcu, E" sort="Mumcu, E" uniqKey="Mumcu E" first="E." last="Mumcu">E. Mumcu</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001273 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Istex/Checkpoint/biblio.hfd -nk 001273 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Istex |étape= Checkpoint |type= RBID |clé= ISTEX:59B0D50673DED641B570AAD091BCC69C0CD4FA84 |texte= A comparative in vitro evaluation of two different magnetic devices detecting the stability of osseo‐integrated implants }}
This area was generated with Dilib version V0.6.32. |