Accuracy of Linear Measurement Provided by Cone Beam Computed Tomography to Assess Bone Quantity in the Posterior Maxilla: A Human Cadaver Study

Identifieur interne : 000182 ( France/Analysis ); précédent : 000181; suivant : 000183

Accuracy of Linear Measurement Provided by Cone Beam Computed Tomography to Assess Bone Quantity in the Posterior Maxilla: A Human Cadaver Study

Auteurs : Sophie Veyre-Goulet [France] ; Thomas Fortin [France] ; Anthony Thierry [France]

Source :

RBID : ISTEX:273A88A04F5434047FECAAF19F428CDEEEA41A93

Descripteurs français

English descriptors

Abstract

Purpose: The aim of this study was to assess, for implant placement in the posterior maxilla, the accuracy of linear measurements provided by cone beam computed tomography (CBCT) using an image intensifier tube and television (TV) chain as an X‐ray detector despite a loss of contrast resolution. The NewTom® 9000 (Quantitative Radiology, Verona, Italy) was used to explore the posterior maxilla.

Url:
DOI: 10.1111/j.1708-8208.2008.00083.x


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:273A88A04F5434047FECAAF19F428CDEEEA41A93

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy of Linear Measurement Provided by Cone Beam Computed Tomography to Assess Bone Quantity in the Posterior Maxilla: A Human Cadaver Study</title>
<author>
<name sortKey="Veyre Oulet, Sophie" sort="Veyre Oulet, Sophie" uniqKey="Veyre Oulet S" first="Sophie" last="Veyre-Goulet">Sophie Veyre-Goulet</name>
</author>
<author>
<name sortKey="Fortin, Thomas" sort="Fortin, Thomas" uniqKey="Fortin T" first="Thomas" last="Fortin">Thomas Fortin</name>
</author>
<author>
<name sortKey="Thierry, Anthony" sort="Thierry, Anthony" uniqKey="Thierry A" first="Anthony" last="Thierry">Anthony Thierry</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:273A88A04F5434047FECAAF19F428CDEEEA41A93</idno>
<date when="2008" year="2008">2008</date>
<idno type="doi">10.1111/j.1708-8208.2008.00083.x</idno>
<idno type="url">https://api.istex.fr/document/273A88A04F5434047FECAAF19F428CDEEEA41A93/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001322</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001322</idno>
<idno type="wicri:Area/Istex/Curation">001322</idno>
<idno type="wicri:Area/Istex/Checkpoint">002744</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">002744</idno>
<idno type="wicri:doubleKey">1523-0899:2008:Veyre Oulet S:accuracy:of:linear</idno>
<idno type="wicri:Area/Main/Merge">006557</idno>
<idno type="wicri:Area/Main/Curation">006474</idno>
<idno type="wicri:Area/Main/Exploration">006474</idno>
<idno type="wicri:Area/France/Extraction">000182</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Accuracy of Linear Measurement Provided by Cone Beam Computed Tomography to Assess Bone Quantity in the Posterior Maxilla: A Human Cadaver Study</title>
<author>
<name sortKey="Veyre Oulet, Sophie" sort="Veyre Oulet, Sophie" uniqKey="Veyre Oulet S" first="Sophie" last="Veyre-Goulet">Sophie Veyre-Goulet</name>
<affiliation wicri:level="3">
<country xml:lang="fr" wicri:curation="lc">France</country>
<wicri:regionArea>Clinical associate professor, Department of Oral Surgery, Dental School, University of Lyon, Lyon</wicri:regionArea>
<placeName>
<region type="region">Auvergne-Rhône-Alpes</region>
<region type="old region">Rhône-Alpes</region>
<settlement type="city">Lyon</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Fortin, Thomas" sort="Fortin, Thomas" uniqKey="Fortin T" first="Thomas" last="Fortin">Thomas Fortin</name>
<affiliation wicri:level="3">
<country xml:lang="fr" wicri:curation="lc">France</country>
<wicri:regionArea>assistant professor, Department of Oral Surgery, Dental School, University of Lyon, Lyon</wicri:regionArea>
<placeName>
<region type="region">Auvergne-Rhône-Alpes</region>
<region type="old region">Rhône-Alpes</region>
<settlement type="city">Lyon</settlement>
</placeName>
</affiliation>
<affiliation wicri:level="1">
<country wicri:rule="url">France</country>
</affiliation>
</author>
<author>
<name sortKey="Thierry, Anthony" sort="Thierry, Anthony" uniqKey="Thierry A" first="Anthony" last="Thierry">Anthony Thierry</name>
<affiliation wicri:level="3">
<country xml:lang="fr">France</country>
<wicri:regionArea>private practice, Lyon</wicri:regionArea>
<placeName>
<region type="region">Auvergne-Rhône-Alpes</region>
<region type="old region">Rhône-Alpes</region>
<settlement type="city">Lyon</settlement>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Implant Dentistry and Related Research</title>
<title level="j" type="alt">CLINICAL IMPLANT DENTISTRY RELATED RESEARCH</title>
<idno type="ISSN">1523-0899</idno>
<idno type="eISSN">1708-8208</idno>
<imprint>
<biblScope unit="vol">10</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="226">226</biblScope>
<biblScope unit="page" to="230">230</biblScope>
<biblScope unit="page-count">5</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2008-12">2008-12</date>
</imprint>
<idno type="ISSN">1523-0899</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1523-0899</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Anatomical site</term>
<term>Bone height</term>
<term>Bone quantity</term>
<term>Bone sections</term>
<term>Bone volume</term>
<term>Buccal</term>
<term>Buccal plate</term>
<term>Cadaver</term>
<term>Cbct</term>
<term>Cbct images</term>
<term>Cbct machine</term>
<term>Clin</term>
<term>Clinical implant dentistry</term>
<term>Cone beam</term>
<term>Contrast resolution</term>
<term>Conventional tomography</term>
<term>Cortical plate</term>
<term>Dental imaging</term>
<term>Dental school</term>
<term>Dentomaxillofac</term>
<term>Dentomaxillofac radiol</term>
<term>Diagnostic imaging</term>
<term>Human cadaver study</term>
<term>Image measurements</term>
<term>Image quality</term>
<term>Image tube</term>
<term>Images differences</term>
<term>Imaging</term>
<term>Implant</term>
<term>Implant axis</term>
<term>Implant placement</term>
<term>Linear measurement</term>
<term>Linear measurements</term>
<term>Maxilla</term>
<term>Maxillary</term>
<term>Maxillary sinus</term>
<term>Newtom</term>
<term>Oral pathol</term>
<term>Oral surg</term>
<term>Oral surgery</term>
<term>Palatal</term>
<term>Palatal plate</term>
<term>Panoramic radiographs</term>
<term>Posterior maxilla</term>
<term>Posterior region</term>
<term>Preoperative</term>
<term>Preoperative planning</term>
<term>Primary reconstruction</term>
<term>Quantitative radiology</term>
<term>Radiol</term>
<term>Radiol endod</term>
<term>Radiological exams</term>
<term>Real measurements</term>
<term>Reference purposes</term>
<term>Reformatted</term>
<term>Ridge mapping</term>
<term>Scatter radiation</term>
<term>Sinus</term>
<term>Soft tissue</term>
<term>Software</term>
<term>Thomas fortin</term>
<term>Tomography</term>
<term>Vital bone</term>
<term>Volumetric images</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Anatomical site</term>
<term>Bone height</term>
<term>Bone quantity</term>
<term>Bone sections</term>
<term>Bone volume</term>
<term>Buccal</term>
<term>Buccal plate</term>
<term>Cadaver</term>
<term>Cbct</term>
<term>Cbct images</term>
<term>Cbct machine</term>
<term>Clin</term>
<term>Clinical implant dentistry</term>
<term>Cone beam</term>
<term>Contrast resolution</term>
<term>Conventional tomography</term>
<term>Cortical plate</term>
<term>Dental imaging</term>
<term>Dental school</term>
<term>Dentomaxillofac</term>
<term>Dentomaxillofac radiol</term>
<term>Diagnostic imaging</term>
<term>Human cadaver study</term>
<term>Image measurements</term>
<term>Image quality</term>
<term>Image tube</term>
<term>Images differences</term>
<term>Imaging</term>
<term>Implant</term>
<term>Implant axis</term>
<term>Implant placement</term>
<term>Linear measurement</term>
<term>Linear measurements</term>
<term>Maxilla</term>
<term>Maxillary</term>
<term>Maxillary sinus</term>
<term>Newtom</term>
<term>Oral pathol</term>
<term>Oral surg</term>
<term>Oral surgery</term>
<term>Palatal</term>
<term>Palatal plate</term>
<term>Panoramic radiographs</term>
<term>Posterior maxilla</term>
<term>Posterior region</term>
<term>Preoperative</term>
<term>Preoperative planning</term>
<term>Primary reconstruction</term>
<term>Quantitative radiology</term>
<term>Radiol</term>
<term>Radiol endod</term>
<term>Radiological exams</term>
<term>Real measurements</term>
<term>Reference purposes</term>
<term>Reformatted</term>
<term>Ridge mapping</term>
<term>Scatter radiation</term>
<term>Sinus</term>
<term>Soft tissue</term>
<term>Software</term>
<term>Thomas fortin</term>
<term>Tomography</term>
<term>Vital bone</term>
<term>Volumetric images</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Logiciel</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">Purpose: The aim of this study was to assess, for implant placement in the posterior maxilla, the accuracy of linear measurements provided by cone beam computed tomography (CBCT) using an image intensifier tube and television (TV) chain as an X‐ray detector despite a loss of contrast resolution. The NewTom® 9000 (Quantitative Radiology, Verona, Italy) was used to explore the posterior maxilla.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>France</li>
</country>
<region>
<li>Auvergne-Rhône-Alpes</li>
<li>Rhône-Alpes</li>
</region>
<settlement>
<li>Lyon</li>
</settlement>
</list>
<tree>
<country name="France">
<region name="Auvergne-Rhône-Alpes">
<name sortKey="Veyre Oulet, Sophie" sort="Veyre Oulet, Sophie" uniqKey="Veyre Oulet S" first="Sophie" last="Veyre-Goulet">Sophie Veyre-Goulet</name>
</region>
<name sortKey="Fortin, Thomas" sort="Fortin, Thomas" uniqKey="Fortin T" first="Thomas" last="Fortin">Thomas Fortin</name>
<name sortKey="Fortin, Thomas" sort="Fortin, Thomas" uniqKey="Fortin T" first="Thomas" last="Fortin">Thomas Fortin</name>
<name sortKey="Thierry, Anthony" sort="Thierry, Anthony" uniqKey="Thierry A" first="Anthony" last="Thierry">Anthony Thierry</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/France/Analysis
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000182 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/France/Analysis/biblio.hfd -nk 000182 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    France
   |étape=   Analysis
   |type=    RBID
   |clé=     ISTEX:273A88A04F5434047FECAAF19F428CDEEEA41A93
   |texte=   Accuracy of Linear Measurement Provided by Cone Beam Computed Tomography to Assess Bone Quantity in the Posterior Maxilla: A Human Cadaver Study
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022