Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.

Identifieur interne : 000C74 ( PubMed/Curation ); précédent : 000C73; suivant : 000C75

Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.

Auteurs : Takaharu Goto [Japon] ; Kan Nagao ; Yuichi Ishida ; Yoritoki Tomotake ; Tetsuo Ichikawa

Source :

RBID : pubmed:24975368

Descripteurs français

English descriptors

Abstract

This in vitro study investigated the effect of attachment installation conditions on the load transfer and denture movements of implant overdentures, and aims to clarify the differences among the three types of attachments, namely ball, Locator, and magnet attachments.

DOI: 10.1111/jopr.12177
PubMed: 24975368

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:24975368

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.</title>
<author>
<name sortKey="Goto, Takaharu" sort="Goto, Takaharu" uniqKey="Goto T" first="Takaharu" last="Goto">Takaharu Goto</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima, Institute of Health Biosciences, Tokushima, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima, Institute of Health Biosciences, Tokushima</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Nagao, Kan" sort="Nagao, Kan" uniqKey="Nagao K" first="Kan" last="Nagao">Kan Nagao</name>
</author>
<author>
<name sortKey="Ishida, Yuichi" sort="Ishida, Yuichi" uniqKey="Ishida Y" first="Yuichi" last="Ishida">Yuichi Ishida</name>
</author>
<author>
<name sortKey="Tomotake, Yoritoki" sort="Tomotake, Yoritoki" uniqKey="Tomotake Y" first="Yoritoki" last="Tomotake">Yoritoki Tomotake</name>
</author>
<author>
<name sortKey="Ichikawa, Tetsuo" sort="Ichikawa, Tetsuo" uniqKey="Ichikawa T" first="Tetsuo" last="Ichikawa">Tetsuo Ichikawa</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="RBID">pubmed:24975368</idno>
<idno type="pmid">24975368</idno>
<idno type="doi">10.1111/jopr.12177</idno>
<idno type="wicri:Area/PubMed/Corpus">000C74</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000C74</idno>
<idno type="wicri:Area/PubMed/Curation">000C74</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000C74</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.</title>
<author>
<name sortKey="Goto, Takaharu" sort="Goto, Takaharu" uniqKey="Goto T" first="Takaharu" last="Goto">Takaharu Goto</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima, Institute of Health Biosciences, Tokushima, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima, Institute of Health Biosciences, Tokushima</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Nagao, Kan" sort="Nagao, Kan" uniqKey="Nagao K" first="Kan" last="Nagao">Kan Nagao</name>
</author>
<author>
<name sortKey="Ishida, Yuichi" sort="Ishida, Yuichi" uniqKey="Ishida Y" first="Yuichi" last="Ishida">Yuichi Ishida</name>
</author>
<author>
<name sortKey="Tomotake, Yoritoki" sort="Tomotake, Yoritoki" uniqKey="Tomotake Y" first="Yoritoki" last="Tomotake">Yoritoki Tomotake</name>
</author>
<author>
<name sortKey="Ichikawa, Tetsuo" sort="Ichikawa, Tetsuo" uniqKey="Ichikawa T" first="Tetsuo" last="Ichikawa">Tetsuo Ichikawa</name>
</author>
</analytic>
<series>
<title level="j">Journal of prosthodontics : official journal of the American College of Prosthodontists</title>
<idno type="eISSN">1532-849X</idno>
<imprint>
<date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Dental Implants</term>
<term>Dental Models</term>
<term>Denture Precision Attachment</term>
<term>Denture, Overlay</term>
<term>Mechanical Phenomena</term>
<term>Movement</term>
<term>Time Factors</term>
<term>Transducers</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Attachement de précision</term>
<term>Facteurs temps</term>
<term>Implants dentaires</term>
<term>Modèles dentaires</term>
<term>Mouvement</term>
<term>Overdenture</term>
<term>Phénomènes mécaniques</term>
<term>Transducteurs</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Models</term>
<term>Denture Precision Attachment</term>
<term>Denture, Overlay</term>
<term>Mechanical Phenomena</term>
<term>Movement</term>
<term>Time Factors</term>
<term>Transducers</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Attachement de précision</term>
<term>Facteurs temps</term>
<term>Implants dentaires</term>
<term>Modèles dentaires</term>
<term>Mouvement</term>
<term>Overdenture</term>
<term>Phénomènes mécaniques</term>
<term>Transducteurs</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This in vitro study investigated the effect of attachment installation conditions on the load transfer and denture movements of implant overdentures, and aims to clarify the differences among the three types of attachments, namely ball, Locator, and magnet attachments.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">24975368</PMID>
<DateCompleted>
<Year>2017</Year>
<Month>01</Month>
<Day>10</Day>
</DateCompleted>
<DateRevised>
<Year>2017</Year>
<Month>01</Month>
<Day>11</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1532-849X</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>24</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2015</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>Journal of prosthodontics : official journal of the American College of Prosthodontists</Title>
<ISOAbbreviation>J Prosthodont</ISOAbbreviation>
</Journal>
<ArticleTitle>Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.</ArticleTitle>
<Pagination>
<MedlinePgn>156-63</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/jopr.12177</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">This in vitro study investigated the effect of attachment installation conditions on the load transfer and denture movements of implant overdentures, and aims to clarify the differences among the three types of attachments, namely ball, Locator, and magnet attachments.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Three types of attachments, namely ball, Locator, and magnetic attachments were used. An acrylic resin mandibular edentulous model with two implants placed in the bilateral canine regions and removable overdenture were prepared. The two implants and bilateral molar ridges were connected to three-axis load-cell transducers, and a universal testing machine was used to apply a 50 N vertical force to each site of the occlusal table in the first molar region. The denture movement was measured using a G(2) motion sensor. Three installation conditions, namely, the application of 0, 50, and 100 N loads were used to install each attachment on the denture base. The load transfer and denture movement were then evaluated.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The resultant force decreased with increasing installation load for all attachments. In particular, the resultant force on implants on the loading side of the Locator attachment significantly decreased when the installation load was increased from 0 to 50 N, and that for magnetic attachment significantly decreased when the installation load was increased from 50 to 100 N. For the residual ridges on the loading side, the direction of the forces for all attachments changed to downward with increasing installation load. Furthermore, the yaw Euler angle increased with increasing installation load for the magnetic attachment.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Subject to the limitations of this study, the use of any installation load greater than 0 N is recommended for the installation of ball and Locator attachments on a denture base. Regarding magnetic attachments, our results also recommend installation on a denture base using any installation load greater than 0 N, and suggest that the resultant force acting on the implant can be decreased by increasing the installation load; however, a large installation load of 100 N should be avoided when installing the attachment on the denture base to avoid increasing the denture movement.</AbstractText>
<CopyrightInformation>© 2014 by the American College of Prosthodontists.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Goto</LastName>
<ForeName>Takaharu</ForeName>
<Initials>T</Initials>
<AffiliationInfo>
<Affiliation>Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima, Institute of Health Biosciences, Tokushima, Japan.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Nagao</LastName>
<ForeName>Kan</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ishida</LastName>
<ForeName>Yuichi</ForeName>
<Initials>Y</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Tomotake</LastName>
<ForeName>Yoritoki</ForeName>
<Initials>Y</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ichikawa</LastName>
<ForeName>Tetsuo</ForeName>
<Initials>T</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2014</Year>
<Month>06</Month>
<Day>27</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Prosthodont</MedlineTA>
<NlmUniqueID>9301275</NlmUniqueID>
<ISSNLinking>1059-941X</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003834" MajorTopicYN="Y">Denture Precision Attachment</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D055595" MajorTopicYN="Y">Mechanical Phenomena</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D009068" MajorTopicYN="Y">Movement</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013997" MajorTopicYN="N">Time Factors</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014159" MajorTopicYN="N">Transducers</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">Implant overdenture</Keyword>
<Keyword MajorTopicYN="N">attachment</Keyword>
<Keyword MajorTopicYN="N">denture movement</Keyword>
<Keyword MajorTopicYN="N">installation load</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="accepted">
<Year>2013</Year>
<Month>12</Month>
<Day>13</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>7</Month>
<Day>1</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>7</Month>
<Day>1</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2017</Year>
<Month>1</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">24975368</ArticleId>
<ArticleId IdType="doi">10.1111/jopr.12177</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C74 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000C74 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:24975368
   |texte=   Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:24975368" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020