Evaluation of the success criteria for zirconia dental implants: a four-year clinical and radiological study.

Identifieur interne : 000228 ( PubMed/Curation ); précédent : 000227; suivant : 000229

Evaluation of the success criteria for zirconia dental implants: a four-year clinical and radiological study.

Auteurs : Andrea Enrico Borgonovo [Italie] ; Rachele Censi ; Virna Vavassori ; Marcello Dolci ; Josè Luis Calvo-Guirado ; Rafael Arcesio Delgado Ruiz ; Carlo Maiorana

Source :

RBID : pubmed:24065992

Abstract

Objectives. The aim was to evaluate survival and success rates, soft tissue health, and radiographic marginal bone loss (MBL) of zirconia implants placed in the esthetic and posterior areas of the jaws and in association with multiple or single implant restorations after at least 6 months of definitive restoration. Material and Methods. 35 one-piece zirconium implants were utilized for single or partially edentulous ridges rehabilitation. All implants received immediate temporary restorations and six months after surgery were definitively restored. Every 6 months after implant placement, a clinical-radiographic evaluation was performed. For each radiograph, the measurements of MBL were calculated. Results. The results showed that the mean MBL at 48-month followup was 1.631 mm. The mean MBL during the first year of loading was not more significant for implants placed in the first molar regions than for those positioned in other areas. Moreover, no differences in marginal bone level changes were revealed for multiple and single implants, whereas MBL in the first year was observed to be slightly greater for implants placed in the maxilla than for those placed in the mandible. Conclusion. Zirconia showed a good marginal bone preservation that could be correlated with one-piece morphology and characteristics of zirconia implants.

DOI: 10.1155/2013/463073
PubMed: 24065992

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:24065992

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Evaluation of the success criteria for zirconia dental implants: a four-year clinical and radiological study.</title>
<author>
<name sortKey="Borgonovo, Andrea Enrico" sort="Borgonovo, Andrea Enrico" uniqKey="Borgonovo A" first="Andrea Enrico" last="Borgonovo">Andrea Enrico Borgonovo</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Implantology, Dental Clinic, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, School of Oral Surgery, University of Milan, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Implantology, Dental Clinic, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, School of Oral Surgery, University of Milan, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Censi, Rachele" sort="Censi, Rachele" uniqKey="Censi R" first="Rachele" last="Censi">Rachele Censi</name>
</author>
<author>
<name sortKey="Vavassori, Virna" sort="Vavassori, Virna" uniqKey="Vavassori V" first="Virna" last="Vavassori">Virna Vavassori</name>
</author>
<author>
<name sortKey="Dolci, Marcello" sort="Dolci, Marcello" uniqKey="Dolci M" first="Marcello" last="Dolci">Marcello Dolci</name>
</author>
<author>
<name sortKey="Calvo Guirado, Jose Luis" sort="Calvo Guirado, Jose Luis" uniqKey="Calvo Guirado J" first="Josè Luis" last="Calvo-Guirado">Josè Luis Calvo-Guirado</name>
</author>
<author>
<name sortKey="Delgado Ruiz, Rafael Arcesio" sort="Delgado Ruiz, Rafael Arcesio" uniqKey="Delgado Ruiz R" first="Rafael Arcesio" last="Delgado Ruiz">Rafael Arcesio Delgado Ruiz</name>
</author>
<author>
<name sortKey="Maiorana, Carlo" sort="Maiorana, Carlo" uniqKey="Maiorana C" first="Carlo" last="Maiorana">Carlo Maiorana</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="RBID">pubmed:24065992</idno>
<idno type="pmid">24065992</idno>
<idno type="doi">10.1155/2013/463073</idno>
<idno type="wicri:Area/PubMed/Corpus">000228</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000228</idno>
<idno type="wicri:Area/PubMed/Curation">000228</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000228</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Evaluation of the success criteria for zirconia dental implants: a four-year clinical and radiological study.</title>
<author>
<name sortKey="Borgonovo, Andrea Enrico" sort="Borgonovo, Andrea Enrico" uniqKey="Borgonovo A" first="Andrea Enrico" last="Borgonovo">Andrea Enrico Borgonovo</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Implantology, Dental Clinic, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, School of Oral Surgery, University of Milan, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Implantology, Dental Clinic, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, School of Oral Surgery, University of Milan, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Censi, Rachele" sort="Censi, Rachele" uniqKey="Censi R" first="Rachele" last="Censi">Rachele Censi</name>
</author>
<author>
<name sortKey="Vavassori, Virna" sort="Vavassori, Virna" uniqKey="Vavassori V" first="Virna" last="Vavassori">Virna Vavassori</name>
</author>
<author>
<name sortKey="Dolci, Marcello" sort="Dolci, Marcello" uniqKey="Dolci M" first="Marcello" last="Dolci">Marcello Dolci</name>
</author>
<author>
<name sortKey="Calvo Guirado, Jose Luis" sort="Calvo Guirado, Jose Luis" uniqKey="Calvo Guirado J" first="Josè Luis" last="Calvo-Guirado">Josè Luis Calvo-Guirado</name>
</author>
<author>
<name sortKey="Delgado Ruiz, Rafael Arcesio" sort="Delgado Ruiz, Rafael Arcesio" uniqKey="Delgado Ruiz R" first="Rafael Arcesio" last="Delgado Ruiz">Rafael Arcesio Delgado Ruiz</name>
</author>
<author>
<name sortKey="Maiorana, Carlo" sort="Maiorana, Carlo" uniqKey="Maiorana C" first="Carlo" last="Maiorana">Carlo Maiorana</name>
</author>
</analytic>
<series>
<title level="j">International journal of dentistry</title>
<idno type="ISSN">1687-8728</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Objectives. The aim was to evaluate survival and success rates, soft tissue health, and radiographic marginal bone loss (MBL) of zirconia implants placed in the esthetic and posterior areas of the jaws and in association with multiple or single implant restorations after at least 6 months of definitive restoration. Material and Methods. 35 one-piece zirconium implants were utilized for single or partially edentulous ridges rehabilitation. All implants received immediate temporary restorations and six months after surgery were definitively restored. Every 6 months after implant placement, a clinical-radiographic evaluation was performed. For each radiograph, the measurements of MBL were calculated. Results. The results showed that the mean MBL at 48-month followup was 1.631 mm. The mean MBL during the first year of loading was not more significant for implants placed in the first molar regions than for those positioned in other areas. Moreover, no differences in marginal bone level changes were revealed for multiple and single implants, whereas MBL in the first year was observed to be slightly greater for implants placed in the maxilla than for those placed in the mandible. Conclusion. Zirconia showed a good marginal bone preservation that could be correlated with one-piece morphology and characteristics of zirconia implants.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="PubMed-not-MEDLINE" Owner="NLM">
<PMID Version="1">24065992</PMID>
<DateCompleted>
<Year>2013</Year>
<Month>09</Month>
<Day>25</Day>
</DateCompleted>
<DateRevised>
<Year>2017</Year>
<Month>02</Month>
<Day>20</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Print">1687-8728</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>2013</Volume>
<PubDate>
<Year>2013</Year>
</PubDate>
</JournalIssue>
<Title>International journal of dentistry</Title>
<ISOAbbreviation>Int J Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Evaluation of the success criteria for zirconia dental implants: a four-year clinical and radiological study.</ArticleTitle>
<Pagination>
<MedlinePgn>463073</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1155/2013/463073</ELocationID>
<Abstract>
<AbstractText>Objectives. The aim was to evaluate survival and success rates, soft tissue health, and radiographic marginal bone loss (MBL) of zirconia implants placed in the esthetic and posterior areas of the jaws and in association with multiple or single implant restorations after at least 6 months of definitive restoration. Material and Methods. 35 one-piece zirconium implants were utilized for single or partially edentulous ridges rehabilitation. All implants received immediate temporary restorations and six months after surgery were definitively restored. Every 6 months after implant placement, a clinical-radiographic evaluation was performed. For each radiograph, the measurements of MBL were calculated. Results. The results showed that the mean MBL at 48-month followup was 1.631 mm. The mean MBL during the first year of loading was not more significant for implants placed in the first molar regions than for those positioned in other areas. Moreover, no differences in marginal bone level changes were revealed for multiple and single implants, whereas MBL in the first year was observed to be slightly greater for implants placed in the maxilla than for those placed in the mandible. Conclusion. Zirconia showed a good marginal bone preservation that could be correlated with one-piece morphology and characteristics of zirconia implants.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Borgonovo</LastName>
<ForeName>Andrea Enrico</ForeName>
<Initials>AE</Initials>
<AffiliationInfo>
<Affiliation>Department of Implantology, Dental Clinic, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, School of Oral Surgery, University of Milan, Milan, Italy.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Censi</LastName>
<ForeName>Rachele</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Vavassori</LastName>
<ForeName>Virna</ForeName>
<Initials>V</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Dolci</LastName>
<ForeName>Marcello</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Calvo-Guirado</LastName>
<ForeName>Josè Luis</ForeName>
<Initials>JL</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Delgado Ruiz</LastName>
<ForeName>Rafael Arcesio</ForeName>
<Initials>RA</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Maiorana</LastName>
<ForeName>Carlo</ForeName>
<Initials>C</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2013</Year>
<Month>08</Month>
<Day>26</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Egypt</Country>
<MedlineTA>Int J Dent</MedlineTA>
<NlmUniqueID>101524183</NlmUniqueID>
<ISSNLinking>1687-8728</ISSNLinking>
</MedlineJournalInfo>
<CommentsCorrectionsList>
<CommentsCorrections RefType="Cites">
<RefSource>Scand J Plast Reconstr Surg. 1969;3(2):81-100</RefSource>
<PMID Version="1">4924041</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Prosthodont. 1990 Jul-Aug;3(4):327-40</RefSource>
<PMID Version="1">2088368</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2005;7 Suppl 1:S21-7</RefSource>
<PMID Version="1">16137084</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Minerva Stomatol. 2010 Jul-Aug;59(7-8):381-92</RefSource>
<PMID Version="1">20842075</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 1998 Aug;9(4):218-24</RefSource>
<PMID Version="1">9760896</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 1986 Summer;1(1):11-25</RefSource>
<PMID Version="1">3527955</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 1996 Dec;7(4):303-10</RefSource>
<PMID Version="1">9151595</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Eur J Esthet Dent. 2012 Winter;7(4):396-417</RefSource>
<PMID Version="1">23150869</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 1998 Dec;9(6):357-64</RefSource>
<PMID Version="1">11429937</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Bone Joint Surg Br. 1991 Jan;73(1):25-8</RefSource>
<PMID Version="1">1991768</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 1999 Mar-Apr;14(2):226-32</RefSource>
<PMID Version="1">10212539</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2005 Feb;16(1):26-35</RefSource>
<PMID Version="1">15642028</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Clin Periodontol. 1997 Aug;24(8):568-72</RefSource>
<PMID Version="1">9266344</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Oral Surg Oral Med Oral Pathol Oral Radiol. 2013 Jul;116(1):e1-8</RefSource>
<PMID Version="1">22762921</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 1997 Feb;8(1):58-67</RefSource>
<PMID Version="1">9586457</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2009 Aug;20(8):827-32</RefSource>
<PMID Version="1">19508341</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Dent Res. 2003 Mar;82(3):232-7</RefSource>
<PMID Version="1">12598555</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Oral Implantol. 2003;29(1):8-12</RefSource>
<PMID Version="1">12614079</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2009 Sep;20 Suppl 4:207-15</RefSource>
<PMID Version="1">19663966</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Periodontol. 2002 Mar;73(3):322-33</RefSource>
<PMID Version="1">11922263</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Dent Res. 2006 May;85(5):473-8</RefSource>
<PMID Version="1">16632764</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Clin Periodontol. 1996 Oct;23(10):971-3</RefSource>
<PMID Version="1">8915028</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2014 Feb;16(1):124-37</RefSource>
<PMID Version="1">24533568</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2008 Nov;19(11):1141-7</RefSource>
<PMID Version="1">18983317</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2008 Aug;19(8):823-35</RefSource>
<PMID Version="1">18705814</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2007 Oct;18(5):575-80</RefSource>
<PMID Version="1">17655714</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Oral Implantol. 2012 Dec;38(6):718-22</RefSource>
<PMID Version="1">22066512</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Med Oral Patol Oral Cir Bucal. 2012 Nov 01;17(6):e981-7</RefSource>
<PMID Version="1">22926479</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Periodontol. 2004 Feb;75(2):292-6</RefSource>
<PMID Version="1">15068118</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Prosthodont. 1993 Mar-Apr;6(2):95-105</RefSource>
<PMID Version="1">8329101</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Periodontol. 2000 Apr;71(4):546-9</RefSource>
<PMID Version="1">10807116</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Minerva Stomatol. 2011 May;60(5):229-41</RefSource>
<PMID Version="1">21597428</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2005;7 Suppl 1:S13-20</RefSource>
<PMID Version="1">16137083</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Clin Periodontol. 2006 Apr;33(4):290-5</RefSource>
<PMID Version="1">16553638</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Periodontol. 1997 Jun;68(6):556-62</RefSource>
<PMID Version="1">9203099</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Periodontol. 2002 Oct;73(10 ):1111-7</RefSource>
<PMID Version="1">12416767</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Head Face Med. 2008 Nov 06;4:25</RefSource>
<PMID Version="1">18990214</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Periodontol. 1997 Nov;68(11):1117-30</RefSource>
<PMID Version="1">9407406</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 2002 Nov-Dec;17(6):793-8</RefSource>
<PMID Version="1">12507238</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2012 Mar;23(3):281-6</RefSource>
<PMID Version="1">21806681</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<OtherID Source="NLM">PMC3770060</OtherID>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2013</Year>
<Month>05</Month>
<Day>11</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2013</Year>
<Month>07</Month>
<Day>15</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>9</Month>
<Day>26</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>9</Month>
<Day>26</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2013</Year>
<Month>9</Month>
<Day>26</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">24065992</ArticleId>
<ArticleId IdType="doi">10.1155/2013/463073</ArticleId>
<ArticleId IdType="pmc">PMC3770060</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000228 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000228 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:24065992
   |texte=   Evaluation of the success criteria for zirconia dental implants: a four-year clinical and radiological study.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:24065992" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020