Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique.

Identifieur interne : 000949 ( PubMed/Corpus ); précédent : 000948; suivant : 000950

Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique.

Auteurs : Xue Zhu Zhao ; Wei Hua Xu ; Zhi Hui Tang ; Min Jie Wu ; Jie Zhu ; Si Chen

Source :

RBID : pubmed:25028687

English descriptors

Abstract

To explore the method of manufacturing an implant surgery template with a computer-aided design/computer-aided manufacturing (CAD/CAM) technique and evaluate its precision in clinical cases.

PubMed: 25028687

Links to Exploration step

pubmed:25028687

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique.</title>
<author>
<name sortKey="Zhao, Xue Zhu" sort="Zhao, Xue Zhu" uniqKey="Zhao X" first="Xue Zhu" last="Zhao">Xue Zhu Zhao</name>
</author>
<author>
<name sortKey="Xu, Wei Hua" sort="Xu, Wei Hua" uniqKey="Xu W" first="Wei Hua" last="Xu">Wei Hua Xu</name>
</author>
<author>
<name sortKey="Tang, Zhi Hui" sort="Tang, Zhi Hui" uniqKey="Tang Z" first="Zhi Hui" last="Tang">Zhi Hui Tang</name>
</author>
<author>
<name sortKey="Wu, Min Jie" sort="Wu, Min Jie" uniqKey="Wu M" first="Min Jie" last="Wu">Min Jie Wu</name>
</author>
<author>
<name sortKey="Zhu, Jie" sort="Zhu, Jie" uniqKey="Zhu J" first="Jie" last="Zhu">Jie Zhu</name>
</author>
<author>
<name sortKey="Chen, Si" sort="Chen, Si" uniqKey="Chen S" first="Si" last="Chen">Si Chen</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:25028687</idno>
<idno type="pmid">25028687</idno>
<idno type="wicri:Area/PubMed/Corpus">000949</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000949</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique.</title>
<author>
<name sortKey="Zhao, Xue Zhu" sort="Zhao, Xue Zhu" uniqKey="Zhao X" first="Xue Zhu" last="Zhao">Xue Zhu Zhao</name>
</author>
<author>
<name sortKey="Xu, Wei Hua" sort="Xu, Wei Hua" uniqKey="Xu W" first="Wei Hua" last="Xu">Wei Hua Xu</name>
</author>
<author>
<name sortKey="Tang, Zhi Hui" sort="Tang, Zhi Hui" uniqKey="Tang Z" first="Zhi Hui" last="Tang">Zhi Hui Tang</name>
</author>
<author>
<name sortKey="Wu, Min Jie" sort="Wu, Min Jie" uniqKey="Wu M" first="Min Jie" last="Wu">Min Jie Wu</name>
</author>
<author>
<name sortKey="Zhu, Jie" sort="Zhu, Jie" uniqKey="Zhu J" first="Jie" last="Zhu">Jie Zhu</name>
</author>
<author>
<name sortKey="Chen, Si" sort="Chen, Si" uniqKey="Chen S" first="Si" last="Chen">Si Chen</name>
</author>
</analytic>
<series>
<title level="j">The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)</title>
<idno type="ISSN">1462-6446</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Bone Transplantation (methods)</term>
<term>Computer-Aided Design (standards)</term>
<term>Cone-Beam Computed Tomography (methods)</term>
<term>Dental Implantation, Endosseous (instrumentation)</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Implantation, Endosseous (standards)</term>
<term>Dental Models</term>
<term>Female</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted (methods)</term>
<term>Image Processing, Computer-Assisted (standards)</term>
<term>Imaging, Three-Dimensional (methods)</term>
<term>Imaging, Three-Dimensional (standards)</term>
<term>Jaw, Edentulous, Partially (rehabilitation)</term>
<term>Jaw, Edentulous, Partially (surgery)</term>
<term>Lasers</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Multimodal Imaging (methods)</term>
<term>Patient Care Planning</term>
<term>Software</term>
<term>Surgery, Computer-Assisted (methods)</term>
<term>Surgery, Computer-Assisted (standards)</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Bone Transplantation</term>
<term>Cone-Beam Computed Tomography</term>
<term>Dental Implantation, Endosseous</term>
<term>Image Processing, Computer-Assisted</term>
<term>Imaging, Three-Dimensional</term>
<term>Multimodal Imaging</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" qualifier="standards" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous</term>
<term>Image Processing, Computer-Assisted</term>
<term>Imaging, Three-Dimensional</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Dental Models</term>
<term>Female</term>
<term>Humans</term>
<term>Lasers</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Patient Care Planning</term>
<term>Software</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To explore the method of manufacturing an implant surgery template with a computer-aided design/computer-aided manufacturing (CAD/CAM) technique and evaluate its precision in clinical cases.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">25028687</PMID>
<DateCompleted>
<Year>2015</Year>
<Month>01</Month>
<Day>15</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>07</Month>
<Day>16</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1462-6446</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>17</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2014</Year>
</PubDate>
</JournalIssue>
<Title>The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)</Title>
<ISOAbbreviation>Chin J Dent Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique.</ArticleTitle>
<Pagination>
<MedlinePgn>31-6</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="OBJECTIVES" NlmCategory="OBJECTIVE">To explore the method of manufacturing an implant surgery template with a computer-aided design/computer-aided manufacturing (CAD/CAM) technique and evaluate its precision in clinical cases.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Patients referred to the 2nd Dental Center of Peking University who were partially edentulous, were enrolled and scanned with cone beam computed tomography (CBCT). Diagnostic casts were laser scanned to record the configuration of the patients' dentition and mucosae. CBCT and laser scanning data were subsequently loaded into Simplant software. Implant positions were planned in the software with a computer-aided design technique, and surgical templates were fabricated with a rapid prototyping technique. These templates were used to guide implant placement surgery.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The mean value of linear deviation was 1.00 mm (range 0 to 2.16 mm) for implant shoulder and 1.26 mm (range 0.51 to 2.86 mm) for the implant apex. The mean angular deviation was 4.74 degress (0.37 to 10.28 degrees). Deviations were higher in the posterior region than anterior. The tooth-supported template provided higher precision than did the tooth/ mucosa-supported template, but no statistically significant difference was found.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">Computer-guided implant surgery with the CAD/CAM technique provides dentists with a good platform for preoperative planning, precise implant insertion, and ideal rehabilitation. The protocol of this three-dimensional laser scanning technique can provide precision comparable to that of double-scanning.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Zhao</LastName>
<ForeName>Xue Zhu</ForeName>
<Initials>XZ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Xu</LastName>
<ForeName>Wei Hua</ForeName>
<Initials>WH</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Tang</LastName>
<ForeName>Zhi Hui</ForeName>
<Initials>ZH</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Wu</LastName>
<ForeName>Min Jie</ForeName>
<Initials>MJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Zhu</LastName>
<ForeName>Jie</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Chen</LastName>
<ForeName>Si</ForeName>
<Initials>S</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Chin J Dent Res</MedlineTA>
<NlmUniqueID>100892845</NlmUniqueID>
<ISSNLinking>1462-6446</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016025" MajorTopicYN="N">Bone Transplantation</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="N">Computer-Aided Design</DescriptorName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D054893" MajorTopicYN="N">Cone-Beam Computed Tomography</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007091" MajorTopicYN="N">Image Processing, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
<QualifierName UI="Q000592" MajorTopicYN="N">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D021621" MajorTopicYN="N">Imaging, Three-Dimensional</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
<QualifierName UI="Q000592" MajorTopicYN="N">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007834" MajorTopicYN="Y">Lasers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D064847" MajorTopicYN="N">Multimodal Imaging</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D010347" MajorTopicYN="N">Patient Care Planning</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012984" MajorTopicYN="N">Software</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D025321" MajorTopicYN="N">Surgery, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014584" MajorTopicYN="N">User-Computer Interface</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>7</Month>
<Day>17</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>7</Month>
<Day>17</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>1</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25028687</ArticleId>
<ArticleId IdType="pii">32433</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000949 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000949 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:25028687
   |texte=   Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:25028687" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020