Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial.

Identifieur interne : 000844 ( PubMed/Corpus ); précédent : 000843; suivant : 000845

Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial.

Auteurs : Gerard Torroella-Saura ; Javier Mareque-Bueno ; Josep Cabratosa-Termes ; Federico Hernández-Alfaro ; Eduard Ferrés-Padr ; José Luis Calvo-Guirado

Source :

RBID : pubmed:25327537

English descriptors

Abstract

The aim of this study was to evaluate the effect of two different designs, tapered vs cylindrical, on the primary stability of implants placed with an immediate loading protocol in edentulous mandibles to support fixed prostheses within occlusal contacts during the first 48 h.

DOI: 10.1111/clr.12506
PubMed: 25327537

Links to Exploration step

pubmed:25327537

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial.</title>
<author>
<name sortKey="Torroella Saura, Gerard" sort="Torroella Saura, Gerard" uniqKey="Torroella Saura G" first="Gerard" last="Torroella-Saura">Gerard Torroella-Saura</name>
<affiliation>
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, School of Dentistry, Universitat International de Catalunya, Barcelona, Spain.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Mareque Bueno, Javier" sort="Mareque Bueno, Javier" uniqKey="Mareque Bueno J" first="Javier" last="Mareque-Bueno">Javier Mareque-Bueno</name>
</author>
<author>
<name sortKey="Cabratosa Termes, Josep" sort="Cabratosa Termes, Josep" uniqKey="Cabratosa Termes J" first="Josep" last="Cabratosa-Termes">Josep Cabratosa-Termes</name>
</author>
<author>
<name sortKey="Hernandez Alfaro, Federico" sort="Hernandez Alfaro, Federico" uniqKey="Hernandez Alfaro F" first="Federico" last="Hernández-Alfaro">Federico Hernández-Alfaro</name>
</author>
<author>
<name sortKey="Ferres Padr, Eduard" sort="Ferres Padr, Eduard" uniqKey="Ferres Padr E" first="Eduard" last="Ferrés-Padr">Eduard Ferrés-Padr</name>
</author>
<author>
<name sortKey="Calvo Guirado, Jose Luis" sort="Calvo Guirado, Jose Luis" uniqKey="Calvo Guirado J" first="José Luis" last="Calvo-Guirado">José Luis Calvo-Guirado</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="RBID">pubmed:25327537</idno>
<idno type="pmid">25327537</idno>
<idno type="doi">10.1111/clr.12506</idno>
<idno type="wicri:Area/PubMed/Corpus">000844</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000844</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial.</title>
<author>
<name sortKey="Torroella Saura, Gerard" sort="Torroella Saura, Gerard" uniqKey="Torroella Saura G" first="Gerard" last="Torroella-Saura">Gerard Torroella-Saura</name>
<affiliation>
<nlm:affiliation>Department of Oral and Maxillofacial Surgery, School of Dentistry, Universitat International de Catalunya, Barcelona, Spain.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Mareque Bueno, Javier" sort="Mareque Bueno, Javier" uniqKey="Mareque Bueno J" first="Javier" last="Mareque-Bueno">Javier Mareque-Bueno</name>
</author>
<author>
<name sortKey="Cabratosa Termes, Josep" sort="Cabratosa Termes, Josep" uniqKey="Cabratosa Termes J" first="Josep" last="Cabratosa-Termes">Josep Cabratosa-Termes</name>
</author>
<author>
<name sortKey="Hernandez Alfaro, Federico" sort="Hernandez Alfaro, Federico" uniqKey="Hernandez Alfaro F" first="Federico" last="Hernández-Alfaro">Federico Hernández-Alfaro</name>
</author>
<author>
<name sortKey="Ferres Padr, Eduard" sort="Ferres Padr, Eduard" uniqKey="Ferres Padr E" first="Eduard" last="Ferrés-Padr">Eduard Ferrés-Padr</name>
</author>
<author>
<name sortKey="Calvo Guirado, Jose Luis" sort="Calvo Guirado, Jose Luis" uniqKey="Calvo Guirado J" first="José Luis" last="Calvo-Guirado">José Luis Calvo-Guirado</name>
</author>
</analytic>
<series>
<title level="j">Clinical oral implants research</title>
<idno type="eISSN">1600-0501</idno>
<imprint>
<date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Dental Implants</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Female</term>
<term>Humans</term>
<term>Immediate Dental Implant Loading</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Male</term>
<term>Mandible</term>
<term>Prospective Studies</term>
<term>Torque</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Female</term>
<term>Humans</term>
<term>Immediate Dental Implant Loading</term>
<term>Male</term>
<term>Mandible</term>
<term>Prospective Studies</term>
<term>Torque</term>
<term>Treatment Outcome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The aim of this study was to evaluate the effect of two different designs, tapered vs cylindrical, on the primary stability of implants placed with an immediate loading protocol in edentulous mandibles to support fixed prostheses within occlusal contacts during the first 48 h.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">25327537</PMID>
<DateCompleted>
<Year>2016</Year>
<Month>12</Month>
<Day>13</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>12</Month>
<Day>30</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1600-0501</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>26</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2015</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Clinical oral implants research</Title>
<ISOAbbreviation>Clin Oral Implants Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial.</ArticleTitle>
<Pagination>
<MedlinePgn>240-4</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/clr.12506</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVES" NlmCategory="OBJECTIVE">The aim of this study was to evaluate the effect of two different designs, tapered vs cylindrical, on the primary stability of implants placed with an immediate loading protocol in edentulous mandibles to support fixed prostheses within occlusal contacts during the first 48 h.</AbstractText>
<AbstractText Label="MATERIAL AND METHODS" NlmCategory="METHODS">Tapered and cylindrical implants were placed in a split-mouth study using the same implant protocol in ten patients with edentulous jaws. A total of 20 tapered implants (test group) and 20 cylindrical implants (control group) were placed. All implants were loaded immediately with provisional fixed prostheses during the healing period before the final restoration. The implants were evaluated at the implant placement by analyzing the insertion torque values (ITVs) and the resonance frequency analysis (RFA) and after the healing period of three months, the success of those implants and the marginal bone loss were evaluated.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Two cylindrical implants were mobile within the same patient and no tapered implants failed, resulting in implant survival rates of 90% and 100%, respectively after three months. The ITVs were statistically significantly different (P = 0.0210) for the tapered implants than for the cylindrical implants. However, no statistically significant differences in RFA values were found (P = 0.6063) when comparing the implant designs and the primary stability measured with implant stability quotient (ISQ) values. The control group resulted in a mean bone loss after three months of 0.91 mm while the test group resulted 0.42 mm.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">The tapered implant achieved greater primary stability values measured with ITVs and less marginal bone loss than the cylindrical implants.</AbstractText>
<CopyrightInformation>© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Torroella-Saura</LastName>
<ForeName>Gerard</ForeName>
<Initials>G</Initials>
<AffiliationInfo>
<Affiliation>Department of Oral and Maxillofacial Surgery, School of Dentistry, Universitat International de Catalunya, Barcelona, Spain.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Mareque-Bueno</LastName>
<ForeName>Javier</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Cabratosa-Termes</LastName>
<ForeName>Josep</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Hernández-Alfaro</LastName>
<ForeName>Federico</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ferrés-Padró</LastName>
<ForeName>Eduard</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Calvo-Guirado</LastName>
<ForeName>José Luis</ForeName>
<Initials>JL</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016449">Randomized Controlled Trial</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2014</Year>
<Month>10</Month>
<Day>18</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Denmark</Country>
<MedlineTA>Clin Oral Implants Res</MedlineTA>
<NlmUniqueID>9105713</NlmUniqueID>
<ISSNLinking>0905-7161</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="Y">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D057893" MajorTopicYN="Y">Immediate Dental Implant Loading</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011446" MajorTopicYN="N">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019415" MajorTopicYN="N">Torque</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016896" MajorTopicYN="N">Treatment Outcome</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">edentulous mandible</Keyword>
<Keyword MajorTopicYN="N">immediate loading</Keyword>
<Keyword MajorTopicYN="N">implant design</Keyword>
<Keyword MajorTopicYN="N">insertion torque</Keyword>
<Keyword MajorTopicYN="N">primary stability</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="accepted">
<Year>2014</Year>
<Month>09</Month>
<Day>28</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>10</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>10</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2016</Year>
<Month>12</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25327537</ArticleId>
<ArticleId IdType="doi">10.1111/clr.12506</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000844 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000844 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:25327537
   |texte=   Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:25327537" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020