A hinged two-part partial denture used in conjunction with severely tilted teeth: a case report.
Identifieur interne : 000758 ( PubMed/Corpus ); précédent : 000757; suivant : 000759A hinged two-part partial denture used in conjunction with severely tilted teeth: a case report.
Auteurs : S. Singhota ; D C Attrill ; U S Patel ; P. MurphySource :
- The European journal of prosthodontics and restorative dentistry [ 0965-7452 ] ; 2014.
English descriptors
- KwdEn :
- Chromium Alloys (chemistry), Denture Design, Denture Retention (instrumentation), Denture, Partial, Removable, Female, Humans, Jaw, Edentulous, Partially (classification), Jaw, Edentulous, Partially (rehabilitation), Malocclusion, Angle Class II (rehabilitation), Mandible (pathology), Middle Aged, Patient Care Planning.
- MESH :
- chemical , chemistry : Chromium Alloys.
- classification : Jaw, Edentulous, Partially.
- instrumentation : Denture Retention.
- pathology : Mandible.
- rehabilitation : Jaw, Edentulous, Partially, Malocclusion, Angle Class II.
- Denture Design, Denture, Partial, Removable, Female, Humans, Middle Aged, Patient Care Planning.
Abstract
A two-part sectional denture can be a useful treatment option when the presence of severe hard tissue undercuts compromises the provision of a satisfactory conventional prosthesis. This article presents a case report illustrating the effective use of a hinged two-part denture in restoring a mandibular Kennedy Class IV edentulous area. A sectional denture approach was selected because of severe proximal and lingual undercuts.
PubMed: 25134363
Links to Exploration step
pubmed:25134363Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">A hinged two-part partial denture used in conjunction with severely tilted teeth: a case report.</title>
<author><name sortKey="Singhota, S" sort="Singhota, S" uniqKey="Singhota S" first="S" last="Singhota">S. Singhota</name>
</author>
<author><name sortKey="Attrill, D C" sort="Attrill, D C" uniqKey="Attrill D" first="D C" last="Attrill">D C Attrill</name>
</author>
<author><name sortKey="Patel, U S" sort="Patel, U S" uniqKey="Patel U" first="U S" last="Patel">U S Patel</name>
</author>
<author><name sortKey="Murphy, P" sort="Murphy, P" uniqKey="Murphy P" first="P" last="Murphy">P. Murphy</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:25134363</idno>
<idno type="pmid">25134363</idno>
<idno type="wicri:Area/PubMed/Corpus">000758</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000758</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">A hinged two-part partial denture used in conjunction with severely tilted teeth: a case report.</title>
<author><name sortKey="Singhota, S" sort="Singhota, S" uniqKey="Singhota S" first="S" last="Singhota">S. Singhota</name>
</author>
<author><name sortKey="Attrill, D C" sort="Attrill, D C" uniqKey="Attrill D" first="D C" last="Attrill">D C Attrill</name>
</author>
<author><name sortKey="Patel, U S" sort="Patel, U S" uniqKey="Patel U" first="U S" last="Patel">U S Patel</name>
</author>
<author><name sortKey="Murphy, P" sort="Murphy, P" uniqKey="Murphy P" first="P" last="Murphy">P. Murphy</name>
</author>
</analytic>
<series><title level="j">The European journal of prosthodontics and restorative dentistry</title>
<idno type="ISSN">0965-7452</idno>
<imprint><date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Chromium Alloys (chemistry)</term>
<term>Denture Design</term>
<term>Denture Retention (instrumentation)</term>
<term>Denture, Partial, Removable</term>
<term>Female</term>
<term>Humans</term>
<term>Jaw, Edentulous, Partially (classification)</term>
<term>Jaw, Edentulous, Partially (rehabilitation)</term>
<term>Malocclusion, Angle Class II (rehabilitation)</term>
<term>Mandible (pathology)</term>
<term>Middle Aged</term>
<term>Patient Care Planning</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en"><term>Chromium Alloys</term>
</keywords>
<keywords scheme="MESH" qualifier="classification" xml:lang="en"><term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Denture Retention</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en"><term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Jaw, Edentulous, Partially</term>
<term>Malocclusion, Angle Class II</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Denture Design</term>
<term>Denture, Partial, Removable</term>
<term>Female</term>
<term>Humans</term>
<term>Middle Aged</term>
<term>Patient Care Planning</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A two-part sectional denture can be a useful treatment option when the presence of severe hard tissue undercuts compromises the provision of a satisfactory conventional prosthesis. This article presents a case report illustrating the effective use of a hinged two-part denture in restoring a mandibular Kennedy Class IV edentulous area. A sectional denture approach was selected because of severe proximal and lingual undercuts.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">25134363</PMID>
<DateCompleted><Year>2014</Year>
<Month>09</Month>
<Day>04</Day>
</DateCompleted>
<DateRevised><Year>2014</Year>
<Month>08</Month>
<Day>19</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0965-7452</ISSN>
<JournalIssue CitedMedium="Print"><Volume>22</Volume>
<Issue>2</Issue>
<PubDate><Year>2014</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>The European journal of prosthodontics and restorative dentistry</Title>
<ISOAbbreviation>Eur J Prosthodont Restor Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>A hinged two-part partial denture used in conjunction with severely tilted teeth: a case report.</ArticleTitle>
<Pagination><MedlinePgn>64-6</MedlinePgn>
</Pagination>
<Abstract><AbstractText>A two-part sectional denture can be a useful treatment option when the presence of severe hard tissue undercuts compromises the provision of a satisfactory conventional prosthesis. This article presents a case report illustrating the effective use of a hinged two-part denture in restoring a mandibular Kennedy Class IV edentulous area. A sectional denture approach was selected because of severe proximal and lingual undercuts.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Singhota</LastName>
<ForeName>S</ForeName>
<Initials>S</Initials>
</Author>
<Author ValidYN="Y"><LastName>Attrill</LastName>
<ForeName>D C</ForeName>
<Initials>DC</Initials>
</Author>
<Author ValidYN="Y"><LastName>Patel</LastName>
<ForeName>U S</ForeName>
<Initials>US</Initials>
</Author>
<Author ValidYN="Y"><LastName>Murphy</LastName>
<ForeName>P</ForeName>
<Initials>P</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>England</Country>
<MedlineTA>Eur J Prosthodont Restor Dent</MedlineTA>
<NlmUniqueID>9314899</NlmUniqueID>
<ISSNLinking>0965-7452</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D002858">Chromium Alloys</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D002858" MajorTopicYN="N">Chromium Alloys</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003779" MajorTopicYN="Y">Denture Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003781" MajorTopicYN="N">Denture Retention</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003832" MajorTopicYN="Y">Denture, Partial, Removable</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000145" MajorTopicYN="N">classification</QualifierName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008312" MajorTopicYN="N">Malocclusion, Angle Class II</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D010347" MajorTopicYN="N">Patient Care Planning</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2014</Year>
<Month>8</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2014</Year>
<Month>8</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2014</Year>
<Month>9</Month>
<Day>5</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">25134363</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000758 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000758 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:25134363 |texte= A hinged two-part partial denture used in conjunction with severely tilted teeth: a case report. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:25134363" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV1
This area was generated with Dilib version V0.6.33. |