The effect of cantilevered bar length on strain around two implants supporting a mandibular overdenture.
Identifieur interne : 000548 ( PubMed/Corpus ); précédent : 000547; suivant : 000549The effect of cantilevered bar length on strain around two implants supporting a mandibular overdenture.
Auteurs : Moustafa Abdou Elsyad ; Yasmeen Fathy Al-Mahdy ; Mahmoud Gamal Salloum ; Ehab Abdelnabi ElsaihSource :
- The International journal of oral & maxillofacial implants [ 1942-4434 ]
English descriptors
- KwdEn :
- MESH :
- chemical : Acrylic Resins.
- methods : Dental Stress Analysis.
- Dental Prosthesis, Implant-Supported, Denture, Overlay, Humans, Mandible.
Abstract
The aim of this study was to evaluate the effect of cantilevered bar length on strain produced around two implants supporting a mandibular overdenture.
PubMed: 23748333
Links to Exploration step
pubmed:23748333Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">The effect of cantilevered bar length on strain around two implants supporting a mandibular overdenture.</title>
<author><name sortKey="Elsyad, Moustafa Abdou" sort="Elsyad, Moustafa Abdou" uniqKey="Elsyad M" first="Moustafa Abdou" last="Elsyad">Moustafa Abdou Elsyad</name>
<affiliation><nlm:affiliation>Faculty of Dentistry, Mansoura University, ElDakahlia, Egypt. M_syad@mans.edu.eg</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Al Mahdy, Yasmeen Fathy" sort="Al Mahdy, Yasmeen Fathy" uniqKey="Al Mahdy Y" first="Yasmeen Fathy" last="Al-Mahdy">Yasmeen Fathy Al-Mahdy</name>
</author>
<author><name sortKey="Salloum, Mahmoud Gamal" sort="Salloum, Mahmoud Gamal" uniqKey="Salloum M" first="Mahmoud Gamal" last="Salloum">Mahmoud Gamal Salloum</name>
</author>
<author><name sortKey="Elsaih, Ehab Abdelnabi" sort="Elsaih, Ehab Abdelnabi" uniqKey="Elsaih E" first="Ehab Abdelnabi" last="Elsaih">Ehab Abdelnabi Elsaih</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>2013 May-Jun</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:23748333</idno>
<idno type="pmid">23748333</idno>
<idno type="wicri:Area/PubMed/Corpus">000548</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000548</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">The effect of cantilevered bar length on strain around two implants supporting a mandibular overdenture.</title>
<author><name sortKey="Elsyad, Moustafa Abdou" sort="Elsyad, Moustafa Abdou" uniqKey="Elsyad M" first="Moustafa Abdou" last="Elsyad">Moustafa Abdou Elsyad</name>
<affiliation><nlm:affiliation>Faculty of Dentistry, Mansoura University, ElDakahlia, Egypt. M_syad@mans.edu.eg</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Al Mahdy, Yasmeen Fathy" sort="Al Mahdy, Yasmeen Fathy" uniqKey="Al Mahdy Y" first="Yasmeen Fathy" last="Al-Mahdy">Yasmeen Fathy Al-Mahdy</name>
</author>
<author><name sortKey="Salloum, Mahmoud Gamal" sort="Salloum, Mahmoud Gamal" uniqKey="Salloum M" first="Mahmoud Gamal" last="Salloum">Mahmoud Gamal Salloum</name>
</author>
<author><name sortKey="Elsaih, Ehab Abdelnabi" sort="Elsaih, Ehab Abdelnabi" uniqKey="Elsaih E" first="Ehab Abdelnabi" last="Elsaih">Ehab Abdelnabi Elsaih</name>
</author>
</analytic>
<series><title level="j">The International journal of oral & maxillofacial implants</title>
<idno type="eISSN">1942-4434</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acrylic Resins</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Stress Analysis (methods)</term>
<term>Denture, Overlay</term>
<term>Humans</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Acrylic Resins</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Dental Stress Analysis</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Dental Prosthesis, Implant-Supported</term>
<term>Denture, Overlay</term>
<term>Humans</term>
<term>Mandible</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The aim of this study was to evaluate the effect of cantilevered bar length on strain produced around two implants supporting a mandibular overdenture.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">23748333</PMID>
<DateCompleted><Year>2014</Year>
<Month>04</Month>
<Day>14</Day>
</DateCompleted>
<DateRevised><Year>2013</Year>
<Month>06</Month>
<Day>10</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Electronic">1942-4434</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>28</Volume>
<Issue>3</Issue>
<PubDate><MedlineDate>2013 May-Jun</MedlineDate>
</PubDate>
</JournalIssue>
<Title>The International journal of oral & maxillofacial implants</Title>
<ISOAbbreviation>Int J Oral Maxillofac Implants</ISOAbbreviation>
</Journal>
<ArticleTitle>The effect of cantilevered bar length on strain around two implants supporting a mandibular overdenture.</ArticleTitle>
<Pagination><MedlinePgn>e143-50</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.11607/jomi.2467</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The aim of this study was to evaluate the effect of cantilevered bar length on strain produced around two implants supporting a mandibular overdenture.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Two root-form implants were placed bilaterally in the canine region of an edentulous acrylic resin mandibular cast and connected with a resilient bar/clip attachment. Four linear strain gauges were bonded to the acrylic resin at the mesial and distal surfaces of each implant. Each gauge was wired separately into a 1/4 Wheatstone bridge of a multichannel digital bridge amplifier. Strains were measured without cantilevered bar extensions (control group) and with the following lengths of cantilevered bars: 11 mm (group 1), 9 mm (group 2), and 7 mm (group 3). For each cantilevered bar length, strains were measured using clips placed on the cantilevers and attached to the overdenture (bar-clip contact) and without clips (bar-acrylic resin contact). Strain measurements were performed under central and unilateral loading using a loading device.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The bar with cantilevers (either with or without clips) demonstrated a significant increase in strain compared to the bar without cantilevers. The 11-mm cantilever length generated the highest peri-implant strain values, while the 7-mm length recorded the lowest. For all cantilevered bar lengths, the strains significantly decreased with bar-clip contact compared to bar-acrylic resin contact. Under central loading, distal and mesial peri-implant strains were the highest and the lowest values, respectively, while under unilateral loading, the highest strain was recorded at distal sites of the loading side and the lowest was recorded at distal sites of the nonloading side. A positive correlation was found between the recorded strain and the cantilevered bar length.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">The 7-mm cantilevered bar with clips placed on the cantilevers was recommended when two implants were used to support mandibular overdentures, as it demonstrated the lowest magnitude of strains with no significant differences between peri-implant sites.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Elsyad</LastName>
<ForeName>Moustafa Abdou</ForeName>
<Initials>MA</Initials>
<AffiliationInfo><Affiliation>Faculty of Dentistry, Mansoura University, ElDakahlia, Egypt. M_syad@mans.edu.eg</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Al-Mahdy</LastName>
<ForeName>Yasmeen Fathy</ForeName>
<Initials>YF</Initials>
</Author>
<Author ValidYN="Y"><LastName>Salloum</LastName>
<ForeName>Mahmoud Gamal</ForeName>
<Initials>MG</Initials>
</Author>
<Author ValidYN="Y"><LastName>Elsaih</LastName>
<ForeName>Ehab Abdelnabi</ForeName>
<Initials>EA</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Int J Oral Maxillofac Implants</MedlineTA>
<NlmUniqueID>8611905</NlmUniqueID>
<ISSNLinking>0882-2786</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000180" MajorTopicYN="N">Acrylic Resins</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003799" MajorTopicYN="N">Dental Stress Analysis</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2013</Year>
<Month>6</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2013</Year>
<Month>6</Month>
<Day>12</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2014</Year>
<Month>4</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">23748333</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000548 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000548 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:23748333 |texte= The effect of cantilevered bar length on strain around two implants supporting a mandibular overdenture. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:23748333" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV1
This area was generated with Dilib version V0.6.33. |