Removal of a fractured locator abutment screw fragment.

Identifieur interne : 000514 ( PubMed/Corpus ); précédent : 000513; suivant : 000515

Removal of a fractured locator abutment screw fragment.

Auteurs : Ilser Turkyilmaz ; Matthew Joseph Vierra ; Neset Volkan Asar

Source :

RBID : pubmed:24685807

English descriptors

Abstract

Although, dental implants have been a predictable option to support several types of restorations, mechanical problems are not uncommon. Retaining and abutment screw loosenings/fractures are one of the most common technical problems.

PubMed: 24685807

Links to Exploration step

pubmed:24685807

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Removal of a fractured locator abutment screw fragment.</title>
<author>
<name sortKey="Turkyilmaz, Ilser" sort="Turkyilmaz, Ilser" uniqKey="Turkyilmaz I" first="Ilser" last="Turkyilmaz">Ilser Turkyilmaz</name>
<affiliation>
<nlm:affiliation>Assistant Professor, Department of Comprehensive Dentistry, Dental School, University of Texas Health Science Center, San Antonio Texas, USA 7703 Floyd Curl Drive, MSC 7912, San Antonio, Texas, USA 78229-3900. Phone: 210-567-5433, Fax: 210-567-6376, e-mail: turkyilmaz@uthscsa.edu.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vierra, Matthew Joseph" sort="Vierra, Matthew Joseph" uniqKey="Vierra M" first="Matthew Joseph" last="Vierra">Matthew Joseph Vierra</name>
<affiliation>
<nlm:affiliation>Resident, Department of Periodontics, Dental School, University of Texas Health Science Center, San Antonio, Texas, USA.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Asar, Neset Volkan" sort="Asar, Neset Volkan" uniqKey="Asar N" first="Neset Volkan" last="Asar">Neset Volkan Asar</name>
<affiliation>
<nlm:affiliation>Visiting Professor, Department of Comprehensive Dentistry, Dental School, University of Texas Health Science Center, San Antonio, Texas USA; Instructor, Department of Prosthodontics, Dental School, Gazi University, Ankara, Turkey.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="RBID">pubmed:24685807</idno>
<idno type="pmid">24685807</idno>
<idno type="wicri:Area/PubMed/Corpus">000514</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000514</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Removal of a fractured locator abutment screw fragment.</title>
<author>
<name sortKey="Turkyilmaz, Ilser" sort="Turkyilmaz, Ilser" uniqKey="Turkyilmaz I" first="Ilser" last="Turkyilmaz">Ilser Turkyilmaz</name>
<affiliation>
<nlm:affiliation>Assistant Professor, Department of Comprehensive Dentistry, Dental School, University of Texas Health Science Center, San Antonio Texas, USA 7703 Floyd Curl Drive, MSC 7912, San Antonio, Texas, USA 78229-3900. Phone: 210-567-5433, Fax: 210-567-6376, e-mail: turkyilmaz@uthscsa.edu.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vierra, Matthew Joseph" sort="Vierra, Matthew Joseph" uniqKey="Vierra M" first="Matthew Joseph" last="Vierra">Matthew Joseph Vierra</name>
<affiliation>
<nlm:affiliation>Resident, Department of Periodontics, Dental School, University of Texas Health Science Center, San Antonio, Texas, USA.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Asar, Neset Volkan" sort="Asar, Neset Volkan" uniqKey="Asar N" first="Neset Volkan" last="Asar">Neset Volkan Asar</name>
<affiliation>
<nlm:affiliation>Visiting Professor, Department of Comprehensive Dentistry, Dental School, University of Texas Health Science Center, San Antonio, Texas USA; Instructor, Department of Prosthodontics, Dental School, Gazi University, Ankara, Turkey.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series>
<title level="j">The journal of contemporary dental practice</title>
<idno type="eISSN">1526-3711</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Dental Implant-Abutment Design</term>
<term>Dental Prosthesis Repair (instrumentation)</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Restoration Failure</term>
<term>Denture Retention (instrumentation)</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Surface Properties</term>
<term>Torque</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Dental Prosthesis Repair</term>
<term>Denture Retention</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Implant-Abutment Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Restoration Failure</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Surface Properties</term>
<term>Torque</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Although, dental implants have been a predictable option to support several types of restorations, mechanical problems are not uncommon. Retaining and abutment screw loosenings/fractures are one of the most common technical problems.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">24685807</PMID>
<DateCompleted>
<Year>2015</Year>
<Month>01</Month>
<Day>15</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>04</Month>
<Day>01</Day>
</DateRevised>
<Article PubModel="Electronic">
<Journal>
<ISSN IssnType="Electronic">1526-3711</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>14</Volume>
<Issue>5</Issue>
<PubDate>
<Year>2013</Year>
<Month>Sep</Month>
<Day>01</Day>
</PubDate>
</JournalIssue>
<Title>The journal of contemporary dental practice</Title>
<ISOAbbreviation>J Contemp Dent Pract</ISOAbbreviation>
</Journal>
<ArticleTitle>Removal of a fractured locator abutment screw fragment.</ArticleTitle>
<Pagination>
<MedlinePgn>968-72</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Although, dental implants have been a predictable option to support several types of restorations, mechanical problems are not uncommon. Retaining and abutment screw loosenings/fractures are one of the most common technical problems.</AbstractText>
<AbstractText Label="AIM" NlmCategory="OBJECTIVE">To present a step-by-step technique in order to remove a broken locater abutment screw fragment.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">A 56-year-old, edentulous man with a fractured locator abutment screw in an implant was referred to our clinic from a private practice. His dentist placed a narrow platform locator abutment onto a regular platform implant and the fracture occurred. Attempts to remove the fractured fragment using a periodontal probe and a manual screw removal driver were unsuccessful.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">This clinical report presents a situation in which a fractured locater abutment screw fragment was successfully removed using an implant repair kit.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">A fractured locater abutment screw fragment was successfully removed using an implant repair kit including drills, drill guides and tapping instruments. To avoid similar complications, it is recommended to use appropriate manufacturer specified torque values in conjunction with compatible restorative components.</AbstractText>
<AbstractText Label="CLINICAL SIGNIFICANCE" NlmCategory="CONCLUSIONS">Retaining and abutment screw loosenings/fractures are one of the most common mechanical problems associated with the implant components. This clinical report showed how to remove a broken screw fragment using proper armamentarium and technique, which might help clinicians eliminate similar problems.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Turkyilmaz</LastName>
<ForeName>Ilser</ForeName>
<Initials>I</Initials>
<AffiliationInfo>
<Affiliation>Assistant Professor, Department of Comprehensive Dentistry, Dental School, University of Texas Health Science Center, San Antonio Texas, USA 7703 Floyd Curl Drive, MSC 7912, San Antonio, Texas, USA 78229-3900. Phone: 210-567-5433, Fax: 210-567-6376, e-mail: turkyilmaz@uthscsa.edu.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Vierra</LastName>
<ForeName>Matthew Joseph</ForeName>
<Initials>MJ</Initials>
<AffiliationInfo>
<Affiliation>Resident, Department of Periodontics, Dental School, University of Texas Health Science Center, San Antonio, Texas, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Asar</LastName>
<ForeName>Neset Volkan</ForeName>
<Initials>NV</Initials>
<AffiliationInfo>
<Affiliation>Visiting Professor, Department of Comprehensive Dentistry, Dental School, University of Texas Health Science Center, San Antonio, Texas USA; Instructor, Department of Prosthodontics, Dental School, Gazi University, Ankara, Turkey.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2013</Year>
<Month>09</Month>
<Day>01</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>India</Country>
<MedlineTA>J Contemp Dent Pract</MedlineTA>
<NlmUniqueID>101090552</NlmUniqueID>
<ISSNLinking>1526-3711</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D059605" MajorTopicYN="Y">Dental Implant-Abutment Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017269" MajorTopicYN="N">Dental Prosthesis Repair</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019232" MajorTopicYN="Y">Dental Restoration Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003781" MajorTopicYN="N">Denture Retention</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019415" MajorTopicYN="N">Torque</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>4</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>1</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>epublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">24685807</ArticleId>
<ArticleId IdType="pii">1526-3711-1179</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000514 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000514 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:24685807
   |texte=   Removal of a fractured locator abutment screw fragment.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:24685807" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020