Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Accuracy of linear vertical measurements in posterior mandible on panoramic view.

Identifieur interne : 000210 ( PubMed/Corpus ); précédent : 000209; suivant : 000211

Accuracy of linear vertical measurements in posterior mandible on panoramic view.

Auteurs : Abdolaziz Haghnegahdar ; Pegah Bronoosh

Source :

RBID : pubmed:23946740

Abstract

One of the most frequent concerns encountered in dental implant treatments is inadequate pre-operative planning. Panoramic radiographs are readily accessible and cost efficient. The aim of this study is to assess the accuracy of vertical measurements in mandibular molar and premolar region on panoramic radiography.

PubMed: 23946740

Links to Exploration step

pubmed:23946740

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy of linear vertical measurements in posterior mandible on panoramic view.</title>
<author>
<name sortKey="Haghnegahdar, Abdolaziz" sort="Haghnegahdar, Abdolaziz" uniqKey="Haghnegahdar A" first="Abdolaziz" last="Haghnegahdar">Abdolaziz Haghnegahdar</name>
<affiliation>
<nlm:affiliation>Department of Oral Radiology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Bronoosh, Pegah" sort="Bronoosh, Pegah" uniqKey="Bronoosh P" first="Pegah" last="Bronoosh">Pegah Bronoosh</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="RBID">pubmed:23946740</idno>
<idno type="pmid">23946740</idno>
<idno type="wicri:Area/PubMed/Corpus">000210</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000210</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Accuracy of linear vertical measurements in posterior mandible on panoramic view.</title>
<author>
<name sortKey="Haghnegahdar, Abdolaziz" sort="Haghnegahdar, Abdolaziz" uniqKey="Haghnegahdar A" first="Abdolaziz" last="Haghnegahdar">Abdolaziz Haghnegahdar</name>
<affiliation>
<nlm:affiliation>Department of Oral Radiology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Bronoosh, Pegah" sort="Bronoosh, Pegah" uniqKey="Bronoosh P" first="Pegah" last="Bronoosh">Pegah Bronoosh</name>
</author>
</analytic>
<series>
<title level="j">Dental research journal</title>
<idno type="ISSN">1735-3327</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">One of the most frequent concerns encountered in dental implant treatments is inadequate pre-operative planning. Panoramic radiographs are readily accessible and cost efficient. The aim of this study is to assess the accuracy of vertical measurements in mandibular molar and premolar region on panoramic radiography.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="PubMed-not-MEDLINE" Owner="NLM">
<PMID Version="1">23946740</PMID>
<DateCompleted>
<Year>2013</Year>
<Month>08</Month>
<Day>15</Day>
</DateCompleted>
<DateRevised>
<Year>2017</Year>
<Month>02</Month>
<Day>20</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1735-3327</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>10</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2013</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Dental research journal</Title>
<ISOAbbreviation>Dent Res J (Isfahan)</ISOAbbreviation>
</Journal>
<ArticleTitle>Accuracy of linear vertical measurements in posterior mandible on panoramic view.</ArticleTitle>
<Pagination>
<MedlinePgn>220-4</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">One of the most frequent concerns encountered in dental implant treatments is inadequate pre-operative planning. Panoramic radiographs are readily accessible and cost efficient. The aim of this study is to assess the accuracy of vertical measurements in mandibular molar and premolar region on panoramic radiography.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Panoramic radiographs were made of a partially edentulous sheep mandible mounted in acryl. Measurements collected from the computer-generated images were compared to measurements made directly on the cross-sectioned hemi-mandibles using t-test. P < 0.05 was considered significant.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The results show that panoramic image is overestimated in predicting the linear measurements in posterior mandible. By applying the magnification factor of 1.29 the difference became insignificant.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">It seems rational to use panoramic radiography for pre-surgical implant assessment of posterior mandible if a true magnification factor is applied.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Haghnegahdar</LastName>
<ForeName>Abdolaziz</ForeName>
<Initials>A</Initials>
<AffiliationInfo>
<Affiliation>Department of Oral Radiology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Bronoosh</LastName>
<ForeName>Pegah</ForeName>
<Initials>P</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Iran</Country>
<MedlineTA>Dent Res J (Isfahan)</MedlineTA>
<NlmUniqueID>101471186</NlmUniqueID>
<ISSNLinking>1735-3327</ISSNLinking>
</MedlineJournalInfo>
<CommentsCorrectionsList>
<CommentsCorrections RefType="Cites">
<RefSource>Dentomaxillofac Radiol. 1991 Feb;20(1):40-2</RefSource>
<PMID Version="1">1884852</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Dentomaxillofac Radiol. 2005 Nov;34(6):343-9</RefSource>
<PMID Version="1">16227476</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Dentomaxillofac Radiol. 1996 Apr;25(2):61-6</RefSource>
<PMID Version="1">9446974</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Oral Maxillofac Surg. 1999 Dec;57(12 ):1408-12</RefSource>
<PMID Version="1">10596660</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2011 Dec;22(12 ):1420-5</RefSource>
<PMID Version="1">21435009</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>World J Radiol. 2010 Jun 28;2(6):224-9</RefSource>
<PMID Version="1">21160634</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Braz Dent J. 2011;22(5):404-9</RefSource>
<PMID Version="1">22011897</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Med Oral Patol Oral Cir Bucal. 2010 Jul 01;15(4):e663-6</RefSource>
<PMID Version="1">20173717</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Mund Kiefer Gesichtschir. 2000 May;4(3):164-70</RefSource>
<PMID Version="1">10900960</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 1989 Winter;4(4):327-32</RefSource>
<PMID Version="1">2639861</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Oral Implantol. 1994;20(2):111-7</RefSource>
<PMID Version="1">7869413</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Aust Orthod J. 2002 Nov;18(2):92-8</RefSource>
<PMID Version="1">12462686</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997 Oct;84(4):430-5</RefSource>
<PMID Version="1">9347510</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2008 Jan;19(1):81-5</RefSource>
<PMID Version="1">17956572</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Dentomaxillofac Radiol. 2011 Feb;40(2):76-83</RefSource>
<PMID Version="1">21239569</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 1994 Dec;5(4):229-38</RefSource>
<PMID Version="1">7640337</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Braz Dent J. 2003;14 (3):209-13</RefSource>
<PMID Version="1">15057399</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Med Phys. 2010 Nov;37(11):5634-44</RefSource>
<PMID Version="1">21158275</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 1990 Spring;5(1):61-9</RefSource>
<PMID Version="1">2202671</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Dentomaxillofac Radiol. 2011 Feb;40(2):67-75</RefSource>
<PMID Version="1">21239568</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<OtherID Source="NLM">PMC3731964</OtherID>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">Implant</Keyword>
<Keyword MajorTopicYN="N">mandible</Keyword>
<Keyword MajorTopicYN="N">panoramic</Keyword>
<Keyword MajorTopicYN="N">vertical measurements</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>8</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>8</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2013</Year>
<Month>8</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">23946740</ArticleId>
<ArticleId IdType="pmc">PMC3731964</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000210 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000210 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:23946740
   |texte=   Accuracy of linear vertical measurements in posterior mandible on panoramic view.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:23946740" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020