Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Computer guided implantology accuracy and complications.

Identifieur interne : 000187 ( PubMed/Corpus ); précédent : 000186; suivant : 000188

Computer guided implantology accuracy and complications.

Auteurs : Vincenzo Bruno ; Mauro Badino ; Francesco Riccitiello ; Gianrico Spagnuolo ; Massimo Amato

Source :

RBID : pubmed:24083034

Abstract

The computer-based method allows the computerized planning of a surgical implantology procedure, using computed tomography (CT) of the maxillary bones and prosthesis. This procedure, however, is not error-free, unless the operator has been well trained and strictly follows the protocol. A 70-year-old woman whom was edentulous asked for a lower jaw implant-supported prosthesis. A computer-guided surgery was planned with an immediate loading according to the NobelGuide technique. However, prior to surgery, new dentures were constructed to adjust the vertical dimension. An interim screwed metal-resin prosthesis was delivered just after the surgery; however, after only two weeks, it was removed because of a complication. Finally, a screwed implant bridge was delivered. The computer guided surgery is a useful procedure when based on an accurate 3D CT-based image data and an implant planning software which minimizes errors.

DOI: 10.1155/2013/701421
PubMed: 24083034

Links to Exploration step

pubmed:24083034

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Computer guided implantology accuracy and complications.</title>
<author>
<name sortKey="Bruno, Vincenzo" sort="Bruno, Vincenzo" uniqKey="Bruno V" first="Vincenzo" last="Bruno">Vincenzo Bruno</name>
<affiliation>
<nlm:affiliation>Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples, Italy.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Badino, Mauro" sort="Badino, Mauro" uniqKey="Badino M" first="Mauro" last="Badino">Mauro Badino</name>
</author>
<author>
<name sortKey="Riccitiello, Francesco" sort="Riccitiello, Francesco" uniqKey="Riccitiello F" first="Francesco" last="Riccitiello">Francesco Riccitiello</name>
</author>
<author>
<name sortKey="Spagnuolo, Gianrico" sort="Spagnuolo, Gianrico" uniqKey="Spagnuolo G" first="Gianrico" last="Spagnuolo">Gianrico Spagnuolo</name>
</author>
<author>
<name sortKey="Amato, Massimo" sort="Amato, Massimo" uniqKey="Amato M" first="Massimo" last="Amato">Massimo Amato</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="RBID">pubmed:24083034</idno>
<idno type="pmid">24083034</idno>
<idno type="doi">10.1155/2013/701421</idno>
<idno type="wicri:Area/PubMed/Corpus">000187</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000187</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Computer guided implantology accuracy and complications.</title>
<author>
<name sortKey="Bruno, Vincenzo" sort="Bruno, Vincenzo" uniqKey="Bruno V" first="Vincenzo" last="Bruno">Vincenzo Bruno</name>
<affiliation>
<nlm:affiliation>Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples, Italy.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Badino, Mauro" sort="Badino, Mauro" uniqKey="Badino M" first="Mauro" last="Badino">Mauro Badino</name>
</author>
<author>
<name sortKey="Riccitiello, Francesco" sort="Riccitiello, Francesco" uniqKey="Riccitiello F" first="Francesco" last="Riccitiello">Francesco Riccitiello</name>
</author>
<author>
<name sortKey="Spagnuolo, Gianrico" sort="Spagnuolo, Gianrico" uniqKey="Spagnuolo G" first="Gianrico" last="Spagnuolo">Gianrico Spagnuolo</name>
</author>
<author>
<name sortKey="Amato, Massimo" sort="Amato, Massimo" uniqKey="Amato M" first="Massimo" last="Amato">Massimo Amato</name>
</author>
</analytic>
<series>
<title level="j">Case reports in dentistry</title>
<idno type="ISSN">2090-6447</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The computer-based method allows the computerized planning of a surgical implantology procedure, using computed tomography (CT) of the maxillary bones and prosthesis. This procedure, however, is not error-free, unless the operator has been well trained and strictly follows the protocol. A 70-year-old woman whom was edentulous asked for a lower jaw implant-supported prosthesis. A computer-guided surgery was planned with an immediate loading according to the NobelGuide technique. However, prior to surgery, new dentures were constructed to adjust the vertical dimension. An interim screwed metal-resin prosthesis was delivered just after the surgery; however, after only two weeks, it was removed because of a complication. Finally, a screwed implant bridge was delivered. The computer guided surgery is a useful procedure when based on an accurate 3D CT-based image data and an implant planning software which minimizes errors.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="PubMed-not-MEDLINE" Owner="NLM">
<PMID Version="1">24083034</PMID>
<DateCompleted>
<Year>2013</Year>
<Month>10</Month>
<Day>01</Day>
</DateCompleted>
<DateRevised>
<Year>2017</Year>
<Month>02</Month>
<Day>20</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Print">2090-6447</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>2013</Volume>
<PubDate>
<Year>2013</Year>
</PubDate>
</JournalIssue>
<Title>Case reports in dentistry</Title>
<ISOAbbreviation>Case Rep Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Computer guided implantology accuracy and complications.</ArticleTitle>
<Pagination>
<MedlinePgn>701421</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1155/2013/701421</ELocationID>
<Abstract>
<AbstractText>The computer-based method allows the computerized planning of a surgical implantology procedure, using computed tomography (CT) of the maxillary bones and prosthesis. This procedure, however, is not error-free, unless the operator has been well trained and strictly follows the protocol. A 70-year-old woman whom was edentulous asked for a lower jaw implant-supported prosthesis. A computer-guided surgery was planned with an immediate loading according to the NobelGuide technique. However, prior to surgery, new dentures were constructed to adjust the vertical dimension. An interim screwed metal-resin prosthesis was delivered just after the surgery; however, after only two weeks, it was removed because of a complication. Finally, a screwed implant bridge was delivered. The computer guided surgery is a useful procedure when based on an accurate 3D CT-based image data and an implant planning software which minimizes errors.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Bruno</LastName>
<ForeName>Vincenzo</ForeName>
<Initials>V</Initials>
<AffiliationInfo>
<Affiliation>Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples, Italy.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Badino</LastName>
<ForeName>Mauro</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Riccitiello</LastName>
<ForeName>Francesco</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Spagnuolo</LastName>
<ForeName>Gianrico</ForeName>
<Initials>G</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Amato</LastName>
<ForeName>Massimo</ForeName>
<Initials>M</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2013</Year>
<Month>09</Month>
<Day>03</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Egypt</Country>
<MedlineTA>Case Rep Dent</MedlineTA>
<NlmUniqueID>101573242</NlmUniqueID>
</MedlineJournalInfo>
<CommentsCorrectionsList>
<CommentsCorrections RefType="Cites">
<RefSource>J Prosthet Dent. 2007 Jun;97(6):331-9</RefSource>
<PMID Version="1">17618915</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2005;7 Suppl 1:S111-20</RefSource>
<PMID Version="1">16137096</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2009 Sep;11(3):238-45</RefSource>
<PMID Version="1">18783423</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2009 Sep;20 Suppl 4:73-86</RefSource>
<PMID Version="1">19663953</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 2009 Mar-Apr;24(2):234-42</RefSource>
<PMID Version="1">19492638</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 2006 Mar-Apr;21(2):298-304</RefSource>
<PMID Version="1">16634502</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 2002 Sep-Oct;17(5):663-70</RefSource>
<PMID Version="1">12381066</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2011 Oct;22(10 ):1157-63</RefSource>
<PMID Version="1">21244498</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2010 May;12 Suppl 1:e104-13</RefSource>
<PMID Version="1">20455905</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2012 Oct;23 Suppl 6:124-35</RefSource>
<PMID Version="1">23062137</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2008 Sep;10 (3):123-7</RefSource>
<PMID Version="1">18241215</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Clin Periodontol. 2010 Apr;37(4):398-403</RefSource>
<PMID Version="1">20447264</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2014 Jan;25(1):116-23</RefSource>
<PMID Version="1">22984962</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2012 Jun;14 (3):321-35</RefSource>
<PMID Version="1">20491822</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Implant Dent Relat Res. 2012 Jun;14 (3):442-53</RefSource>
<PMID Version="1">20156227</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<OtherID Source="NLM">PMC3776542</OtherID>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2013</Year>
<Month>06</Month>
<Day>21</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2013</Year>
<Month>07</Month>
<Day>29</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>10</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>10</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2013</Year>
<Month>10</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">24083034</ArticleId>
<ArticleId IdType="doi">10.1155/2013/701421</ArticleId>
<ArticleId IdType="pmc">PMC3776542</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000187 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000187 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:24083034
   |texte=   Computer guided implantology accuracy and complications.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:24083034" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020