Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls.
Identifieur interne : 000118 ( PubMed/Corpus ); précédent : 000117; suivant : 000119Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls.
Auteurs : Asmáa A. Al-EkrishSource :
- The Saudi dental journal [ 1013-9052 ] ; 2012.
Abstract
To investigate the accuracy and reliability of implant site measurements, recorded from low-dose cone beam computed tomography (CBCT) images.
DOI: 10.1016/j.sdentj.2012.05.001
PubMed: 23960541
Links to Exploration step
pubmed:23960541Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls.</title>
<author><name sortKey="Al Ekrish, Asmaa A" sort="Al Ekrish, Asmaa A" uniqKey="Al Ekrish A" first="Asmáa A" last="Al-Ekrish">Asmáa A. Al-Ekrish</name>
<affiliation><nlm:affiliation>Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, King Saud University, P.O. Box 56810, Riyadh 11564, Saudi Arabia.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:23960541</idno>
<idno type="pmid">23960541</idno>
<idno type="doi">10.1016/j.sdentj.2012.05.001</idno>
<idno type="wicri:Area/PubMed/Corpus">000118</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000118</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls.</title>
<author><name sortKey="Al Ekrish, Asmaa A" sort="Al Ekrish, Asmaa A" uniqKey="Al Ekrish A" first="Asmáa A" last="Al-Ekrish">Asmáa A. Al-Ekrish</name>
<affiliation><nlm:affiliation>Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, King Saud University, P.O. Box 56810, Riyadh 11564, Saudi Arabia.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series><title level="j">The Saudi dental journal</title>
<idno type="ISSN">1013-9052</idno>
<imprint><date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To investigate the accuracy and reliability of implant site measurements, recorded from low-dose cone beam computed tomography (CBCT) images.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="PubMed-not-MEDLINE" Owner="NLM"><PMID Version="1">23960541</PMID>
<DateCompleted><Year>2013</Year>
<Month>08</Month>
<Day>20</Day>
</DateCompleted>
<DateRevised><Year>2017</Year>
<Month>02</Month>
<Day>20</Day>
</DateRevised>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Print">1013-9052</ISSN>
<JournalIssue CitedMedium="Print"><Volume>24</Volume>
<Issue>3-4</Issue>
<PubDate><Year>2012</Year>
<Month>Jul</Month>
</PubDate>
</JournalIssue>
<Title>The Saudi dental journal</Title>
<ISOAbbreviation>Saudi Dent J</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls.</ArticleTitle>
<Pagination><MedlinePgn>127-34</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.sdentj.2012.05.001</ELocationID>
<Abstract><AbstractText Label="OBJECTIVES" NlmCategory="OBJECTIVE">To investigate the accuracy and reliability of implant site measurements, recorded from low-dose cone beam computed tomography (CBCT) images.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">CBCT reformatted images of five skulls were obtained using 40, 20 and 7 s exposure protocols. From these protocols, edentulous ridge dimensions were recorded by two observers and compared with measurements recorded directly from the bone. The measurement errors and intra- and inter-examiner reliability were calculated for each exposure protocol and compared with each other.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The mean absolute errors from the 40, 20 and 7 s protocols were 0.50, 0.46, and 0.51 mm, respectively. The intra-examiner reliability scores were 0.996, 0.995 and 0.998, respectively. The inter-examiner reliability scores were 0.993, 0.998 and 0.994, respectively. There was no significant difference in accuracy or reliability between the three protocols.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">In imaging of dry skulls, lowering the CBCT exposure time from 40 s to 20 or 7 s does not affect the reliability or accuracy of implant site measurements.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Al-Ekrish</LastName>
<ForeName>Asmáa A</ForeName>
<Initials>AA</Initials>
<AffiliationInfo><Affiliation>Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, King Saud University, P.O. Box 56810, Riyadh 11564, Saudi Arabia.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2012</Year>
<Month>06</Month>
<Day>01</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>Saudi Arabia</Country>
<MedlineTA>Saudi Dent J</MedlineTA>
<NlmUniqueID>9313603</NlmUniqueID>
<ISSNLinking>1013-9052</ISSNLinking>
</MedlineJournalInfo>
<CommentsCorrectionsList><CommentsCorrections RefType="Cites"><RefSource>Med Phys. 2001 Feb;28(2):220-31</RefSource>
<PMID Version="1">11243347</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 Dec;104(6):829-36</RefSource>
<PMID Version="1">17448704</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Br J Radiol. 2009 Jan;82(973):35-40</RefSource>
<PMID Version="1">18852212</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Eur Radiol. 1998;8(9):1558-64</RefSource>
<PMID Version="1">9866761</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Implant Dent. 2012 Apr;21(2):78-86</RefSource>
<PMID Version="1">22382748</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Dentomaxillofac Radiol. 2009 Sep;38(6):367-78</RefSource>
<PMID Version="1">19700530</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Dentomaxillofac Radiol. 2006 Jul;35(4):219-26</RefSource>
<PMID Version="1">16798915</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Med Phys. 2000 Jun;27(6):1311-23</RefSource>
<PMID Version="1">10902561</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Dentomaxillofac Radiol. 2004 Nov;33(6):361-9</RefSource>
<PMID Version="1">15665229</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Radiologe. 2003 May;43(5):379-87</RefSource>
<PMID Version="1">12764587</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008 Jul;106(1):106-14</RefSource>
<PMID Version="1">18504152</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Dentomaxillofac Radiol. 2004 Jan;33(1):51-9</RefSource>
<PMID Version="1">15140823</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Dentomaxillofac Radiol. 1999 Jul;28(4):245-8</RefSource>
<PMID Version="1">10455389</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Dentomaxillofac Radiol. 2011 Feb;40(2):67-75</RefSource>
<PMID Version="1">21239568</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<OtherID Source="NLM">PMC3729286</OtherID>
<KeywordList Owner="NOTNLM"><Keyword MajorTopicYN="N">CBCT</Keyword>
<Keyword MajorTopicYN="N">Dental implantation</Keyword>
<Keyword MajorTopicYN="N">Dry skull</Keyword>
<Keyword MajorTopicYN="N">Radiation dosage</Keyword>
<Keyword MajorTopicYN="N">Reliability</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2011</Year>
<Month>12</Month>
<Day>24</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised"><Year>2012</Year>
<Month>04</Month>
<Day>26</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2012</Year>
<Month>05</Month>
<Day>14</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2013</Year>
<Month>8</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2013</Year>
<Month>8</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2013</Year>
<Month>8</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">23960541</ArticleId>
<ArticleId IdType="doi">10.1016/j.sdentj.2012.05.001</ArticleId>
<ArticleId IdType="pii">SDENTJ113</ArticleId>
<ArticleId IdType="pmc">PMC3729286</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000118 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000118 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:23960541 |texte= Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:23960541" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV1
This area was generated with Dilib version V0.6.33. |