Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures.

Identifieur interne : 000C41 ( PubMed/Checkpoint ); précédent : 000C40; suivant : 000C42

Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures.

Auteurs : Bulent Uludag ; Serdar Polat ; Volkan Sahin ; Ali Alper Çomut

Source :

RBID : pubmed:25216129

Descripteurs français

English descriptors

Abstract

The aim of this study was to evaluate the effects of different implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures over a simulated time period of 6 months.

PubMed: 25216129


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:25216129

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures.</title>
<author>
<name sortKey="Uludag, Bulent" sort="Uludag, Bulent" uniqKey="Uludag B" first="Bulent" last="Uludag">Bulent Uludag</name>
</author>
<author>
<name sortKey="Polat, Serdar" sort="Polat, Serdar" uniqKey="Polat S" first="Serdar" last="Polat">Serdar Polat</name>
</author>
<author>
<name sortKey="Sahin, Volkan" sort="Sahin, Volkan" uniqKey="Sahin V" first="Volkan" last="Sahin">Volkan Sahin</name>
</author>
<author>
<name sortKey="Comut, Ali Alper" sort="Comut, Ali Alper" uniqKey="Comut A" first="Ali Alper" last="Çomut">Ali Alper Çomut</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2014 Sep-Oct</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:25216129</idno>
<idno type="pmid">25216129</idno>
<idno type="wicri:Area/PubMed/Corpus">000B69</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000B69</idno>
<idno type="wicri:Area/PubMed/Curation">000B69</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000B69</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000B69</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000B69</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures.</title>
<author>
<name sortKey="Uludag, Bulent" sort="Uludag, Bulent" uniqKey="Uludag B" first="Bulent" last="Uludag">Bulent Uludag</name>
</author>
<author>
<name sortKey="Polat, Serdar" sort="Polat, Serdar" uniqKey="Polat S" first="Serdar" last="Polat">Serdar Polat</name>
</author>
<author>
<name sortKey="Sahin, Volkan" sort="Sahin, Volkan" uniqKey="Sahin V" first="Volkan" last="Sahin">Volkan Sahin</name>
</author>
<author>
<name sortKey="Comut, Ali Alper" sort="Comut, Ali Alper" uniqKey="Comut A" first="Ali Alper" last="Çomut">Ali Alper Çomut</name>
</author>
</analytic>
<series>
<title level="j">The International journal of oral & maxillofacial implants</title>
<idno type="eISSN">1942-4434</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Dental Implants</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Stress Analysis (instrumentation)</term>
<term>Denture Design</term>
<term>Denture Retention (instrumentation)</term>
<term>Denture, Overlay</term>
<term>Humans</term>
<term>Stress, Mechanical</term>
<term>Time Factors</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Analyse du stress dentaire (instrumentation)</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Contrainte mécanique</term>
<term>Facteurs temps</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Overdenture</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Rétention d'appareil de prothèse dentaire (instrumentation)</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Dental Stress Analysis</term>
<term>Denture Retention</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Prosthesis, Implant-Supported</term>
<term>Denture Design</term>
<term>Denture, Overlay</term>
<term>Humans</term>
<term>Stress, Mechanical</term>
<term>Time Factors</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Analyse du stress dentaire</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Contrainte mécanique</term>
<term>Facteurs temps</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Overdenture</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Rétention d'appareil de prothèse dentaire</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The aim of this study was to evaluate the effects of different implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures over a simulated time period of 6 months.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">25216129</PMID>
<DateCompleted>
<Year>2015</Year>
<Month>05</Month>
<Day>18</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>09</Month>
<Day>13</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1942-4434</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>29</Volume>
<Issue>5</Issue>
<PubDate>
<MedlineDate>2014 Sep-Oct</MedlineDate>
</PubDate>
</JournalIssue>
<Title>The International journal of oral & maxillofacial implants</Title>
<ISOAbbreviation>Int J Oral Maxillofac Implants</ISOAbbreviation>
</Journal>
<ArticleTitle>Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures.</ArticleTitle>
<Pagination>
<MedlinePgn>1053-7</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.11607/jomi.3401</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The aim of this study was to evaluate the effects of different implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures over a simulated time period of 6 months.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Two acrylic resin models (models 1 and 2) were fabricated to represent an edentulous mandible. In model 1, the midline implant (in the central region) was vertical and the other two implants (in the canine regions) were 20 degrees divergent from the midline, reaching a total divergence of 40 degrees. In model 2, all three implants were vertically oriented, perpendicular to the occlusal plane and parallel to each other. Three-point vertical pull-out forces were employed in a universal testing machine at a constant crosshead speed of 50 mm/min after overdenture construction and a simulation of 6 months of repeated insertions/removals of the overdenture. Locator attachments with different male combinations and bar and clip attachments were tested in model 1. Clear locator attachments and bar and clip attachments were tested in model 2 and served as controls.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The initial retentive forces of all attachments in both models ranged from 26.58 to 62.05 N, whereas the initial retentive forces of the attachments for only model 1 ranged from 49.58 to 62.05 N. The highest retention value was recorded for clear green locator attachments and the lowest for hader bar yellow clip attachments. Locator attachments showed higher retention values than hader bar yellow clip attachments.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">All attachment systems demonstrated a decrease in retention over time. Locator attachments provided better retention than hader bar yellow clip attachments. The highest retention values were obtained when green male locators were used in combination with male attachments.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Uludag</LastName>
<ForeName>Bulent</ForeName>
<Initials>B</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Polat</LastName>
<ForeName>Serdar</ForeName>
<Initials>S</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Sahin</LastName>
<ForeName>Volkan</ForeName>
<Initials>V</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Çomut</LastName>
<ForeName>Ali Alper</ForeName>
<Initials>AA</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Int J Oral Maxillofac Implants</MedlineTA>
<NlmUniqueID>8611905</NlmUniqueID>
<ISSNLinking>0882-2786</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003799" MajorTopicYN="N">Dental Stress Analysis</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003779" MajorTopicYN="Y">Denture Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003781" MajorTopicYN="N">Denture Retention</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013314" MajorTopicYN="N">Stress, Mechanical</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013997" MajorTopicYN="N">Time Factors</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>9</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>9</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>5</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25216129</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Comut, Ali Alper" sort="Comut, Ali Alper" uniqKey="Comut A" first="Ali Alper" last="Çomut">Ali Alper Çomut</name>
<name sortKey="Polat, Serdar" sort="Polat, Serdar" uniqKey="Polat S" first="Serdar" last="Polat">Serdar Polat</name>
<name sortKey="Sahin, Volkan" sort="Sahin, Volkan" uniqKey="Sahin V" first="Volkan" last="Sahin">Volkan Sahin</name>
<name sortKey="Uludag, Bulent" sort="Uludag, Bulent" uniqKey="Uludag B" first="Bulent" last="Uludag">Bulent Uludag</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C41 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000C41 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:25216129
   |texte=   Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:25216129" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020