Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.

Identifieur interne : 000A61 ( PubMed/Checkpoint ); précédent : 000A60; suivant : 000A62

Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.

Auteurs : Zhen-Zhen Peng [République populaire de Chine] ; Xin-Min Chen ; Jun Wang ; Ai-Jie Li ; Zu-Jie Xu

Source :

RBID : pubmed:23733430

Descripteurs français

English descriptors

Abstract

This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture (CFPD) under vertically concentrated loading with digital laser speckle (DLS) technique.

DOI: 10.1631/jzus.B1200264
PubMed: 23733430


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:23733430

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.</title>
<author>
<name sortKey="Peng, Zhen Zhen" sort="Peng, Zhen Zhen" uniqKey="Peng Z" first="Zhen-Zhen" last="Peng">Zhen-Zhen Peng</name>
<affiliation wicri:level="1">
<nlm:affiliation>State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041</wicri:regionArea>
<wicri:noRegion>Chengdu 610041</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Chen, Xin Min" sort="Chen, Xin Min" uniqKey="Chen X" first="Xin-Min" last="Chen">Xin-Min Chen</name>
</author>
<author>
<name sortKey="Wang, Jun" sort="Wang, Jun" uniqKey="Wang J" first="Jun" last="Wang">Jun Wang</name>
</author>
<author>
<name sortKey="Li, Ai Jie" sort="Li, Ai Jie" uniqKey="Li A" first="Ai-Jie" last="Li">Ai-Jie Li</name>
</author>
<author>
<name sortKey="Xu, Zu Jie" sort="Xu, Zu Jie" uniqKey="Xu Z" first="Zu-Jie" last="Xu">Zu-Jie Xu</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="RBID">pubmed:23733430</idno>
<idno type="pmid">23733430</idno>
<idno type="doi">10.1631/jzus.B1200264</idno>
<idno type="wicri:Area/PubMed/Corpus">000289</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000289</idno>
<idno type="wicri:Area/PubMed/Curation">000289</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000289</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000289</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000289</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.</title>
<author>
<name sortKey="Peng, Zhen Zhen" sort="Peng, Zhen Zhen" uniqKey="Peng Z" first="Zhen-Zhen" last="Peng">Zhen-Zhen Peng</name>
<affiliation wicri:level="1">
<nlm:affiliation>State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041</wicri:regionArea>
<wicri:noRegion>Chengdu 610041</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Chen, Xin Min" sort="Chen, Xin Min" uniqKey="Chen X" first="Xin-Min" last="Chen">Xin-Min Chen</name>
</author>
<author>
<name sortKey="Wang, Jun" sort="Wang, Jun" uniqKey="Wang J" first="Jun" last="Wang">Jun Wang</name>
</author>
<author>
<name sortKey="Li, Ai Jie" sort="Li, Ai Jie" uniqKey="Li A" first="Ai-Jie" last="Li">Ai-Jie Li</name>
</author>
<author>
<name sortKey="Xu, Zu Jie" sort="Xu, Zu Jie" uniqKey="Xu Z" first="Zu-Jie" last="Xu">Zu-Jie Xu</name>
</author>
</analytic>
<series>
<title level="j">Journal of Zhejiang University. Science. B</title>
<idno type="eISSN">1862-1783</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Animals</term>
<term>Bite Force</term>
<term>Compressive Strength (physiology)</term>
<term>Dental Stress Analysis (methods)</term>
<term>Denture Design (methods)</term>
<term>Denture, Partial, Fixed</term>
<term>Dogs</term>
<term>Mandible (physiology)</term>
<term>Mandible (surgery)</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Analyse du stress dentaire ()</term>
<term>Animaux</term>
<term>Chiens</term>
<term>Conception d'appareil de prothèse dentaire ()</term>
<term>Force occlusale</term>
<term>Mandibule ()</term>
<term>Mandibule (physiologie)</term>
<term>Propriétés de surface</term>
<term>Prothèse partielle fixe</term>
<term>Résistance à la compression (physiologie)</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Stress Analysis</term>
<term>Denture Design</term>
</keywords>
<keywords scheme="MESH" qualifier="physiologie" xml:lang="fr">
<term>Mandibule</term>
<term>Résistance à la compression</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Compressive Strength</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Animals</term>
<term>Bite Force</term>
<term>Denture, Partial, Fixed</term>
<term>Dogs</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Analyse du stress dentaire</term>
<term>Animaux</term>
<term>Chiens</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Force occlusale</term>
<term>Mandibule</term>
<term>Propriétés de surface</term>
<term>Prothèse partielle fixe</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture (CFPD) under vertically concentrated loading with digital laser speckle (DLS) technique.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">23733430</PMID>
<DateCompleted>
<Year>2014</Year>
<Month>01</Month>
<Day>15</Day>
</DateCompleted>
<DateRevised>
<Year>2015</Year>
<Month>04</Month>
<Day>26</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1862-1783</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>14</Volume>
<Issue>6</Issue>
<PubDate>
<Year>2013</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Journal of Zhejiang University. Science. B</Title>
<ISOAbbreviation>J Zhejiang Univ Sci B</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.</ArticleTitle>
<Pagination>
<MedlinePgn>526-32</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1631/jzus.B1200264</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture (CFPD) under vertically concentrated loading with digital laser speckle (DLS) technique.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Fresh mandible of beagle dog was used to establish the implant-supported CFPD for specimen. DLS technique was employed for measuring the three-dimensional displacement of the prosthesis under vertically concentrated loading ranging from 200 to 3000 g. The effect of the contact tightness on the displacement of CFPD was investigated by means of changing the contact tightness.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">When an axial concentrated loading was exerted on the pontic of the implant-supported CFPD, the displacement of the CFPD was the greatest. The displacement of the prosthesis decreased with the increase of contact strength. When the contact strength was 0, 0.95, and 3.25 N, the displacement of the buccolingual direction was smaller than that of the mesiodistal direction but greater than that of the occlusogingival direction. When the force on the contact area was 6.50 N, the mesiodistal displacement of the prosthesis was the biggest while the buccolingual displacement was the smallest.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The implant-supported CFPD is an effective therapy for fully or partially edentulous patients. The restoration of the contact area and the selection of the appropriate contact strength can reduce the displacement of the CFPD, and get a better stress distribution. The most appropriate force value is 3.25 N in this study.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Peng</LastName>
<ForeName>Zhen-zhen</ForeName>
<Initials>ZZ</Initials>
<AffiliationInfo>
<Affiliation>State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Chen</LastName>
<ForeName>Xin-min</ForeName>
<Initials>XM</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Wang</LastName>
<ForeName>Jun</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Li</LastName>
<ForeName>Ai-jie</ForeName>
<Initials>AJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Xu</LastName>
<ForeName>Zu-jie</ForeName>
<Initials>ZJ</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>China</Country>
<MedlineTA>J Zhejiang Univ Sci B</MedlineTA>
<NlmUniqueID>101236535</NlmUniqueID>
<ISSNLinking>1673-1581</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<CommentsCorrectionsList>
<CommentsCorrections RefType="Cites">
<RefSource>Quintessence Int. 2004 Jun;35(6):437-41</RefSource>
<PMID Version="1">15202588</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Prosthet Dent. 2004 Feb;91(2):144-50</RefSource>
<PMID Version="1">14970760</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 1990 Winter;5(4):347-59</RefSource>
<PMID Version="1">2094653</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 1993;8(1):19-31</RefSource>
<PMID Version="1">8468083</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Oral Rehabil. 1993 Jul;20(4):413-22</RefSource>
<PMID Version="1">8350176</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Eur J Oral Sci. 1998 Feb;106(1):527-51</RefSource>
<PMID Version="1">9527353</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Oral Rehabil. 1998 Apr;25(4):253-7</RefSource>
<PMID Version="1">9610851</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Dent Res. 1960 May-Jun;39:608-18</RefSource>
<PMID Version="1">14430405</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Oral Rehabil. 2004 Dec;31(12):1208-17</RefSource>
<PMID Version="1">15544658</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Prosthet Dent. 2005 Mar;93(3):227-34</RefSource>
<PMID Version="1">15775923</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Braz Dent J. 2006;17(4):279-84</RefSource>
<PMID Version="1">17262139</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Zhejiang Univ Sci B. 2007 Jun;8(6):416-21</RefSource>
<PMID Version="1">17565512</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2009 May;20(5):441-51</RefSource>
<PMID Version="1">19522975</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Clin Oral Implants Res. 2009 Sep;20 Suppl 4:59-66</RefSource>
<PMID Version="1">19663951</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Implants. 2009;24 Suppl:69-85</RefSource>
<PMID Version="1">19885435</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Prosthet Dent. 2010 Feb;103(2):91-100</RefSource>
<PMID Version="1">20141813</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010 May;109(5):e39-45</RefSource>
<PMID Version="1">20416517</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Maxillofac Surg. 2010 May;39(5):463-8</RefSource>
<PMID Version="1">20153605</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010 Aug;110(2):182-7</RefSource>
<PMID Version="1">20418125</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Periodontol. 2011 Mar;82(3):489-96</RefSource>
<PMID Version="1">20936917</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Sichuan Da Xue Xue Bao Yi Xue Ban. 2013 Jan;44(1):99-103</RefSource>
<PMID Version="1">23600220</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Eur J Oral Sci. 2000 Oct;108(5):368-77</RefSource>
<PMID Version="1">11037752</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Prosthet Dent. 2000 Oct;84(4):432-5</RefSource>
<PMID Version="1">11044851</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Implant Dent. 2002;11(3):286-92</RefSource>
<PMID Version="1">12271568</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Eur J Oral Sci. 2003 Apr;111(2):111-6</RefSource>
<PMID Version="1">12648262</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Int J Oral Surg. 1981 Dec;10(6):387-416</RefSource>
<PMID Version="1">6809663</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000818" MajorTopicYN="N">Animals</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001732" MajorTopicYN="Y">Bite Force</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019245" MajorTopicYN="N">Compressive Strength</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="N">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003799" MajorTopicYN="N">Dental Stress Analysis</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003830" MajorTopicYN="Y">Denture, Partial, Fixed</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004285" MajorTopicYN="N">Dogs</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="Y">physiology</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<OtherID Source="NLM">PMC3682169</OtherID>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>6</Month>
<Day>5</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>6</Month>
<Day>5</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2014</Year>
<Month>1</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">23733430</ArticleId>
<ArticleId IdType="doi">10.1631/jzus.B1200264</ArticleId>
<ArticleId IdType="pmc">PMC3682169</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>République populaire de Chine</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Chen, Xin Min" sort="Chen, Xin Min" uniqKey="Chen X" first="Xin-Min" last="Chen">Xin-Min Chen</name>
<name sortKey="Li, Ai Jie" sort="Li, Ai Jie" uniqKey="Li A" first="Ai-Jie" last="Li">Ai-Jie Li</name>
<name sortKey="Wang, Jun" sort="Wang, Jun" uniqKey="Wang J" first="Jun" last="Wang">Jun Wang</name>
<name sortKey="Xu, Zu Jie" sort="Xu, Zu Jie" uniqKey="Xu Z" first="Zu-Jie" last="Xu">Zu-Jie Xu</name>
</noCountry>
<country name="République populaire de Chine">
<noRegion>
<name sortKey="Peng, Zhen Zhen" sort="Peng, Zhen Zhen" uniqKey="Peng Z" first="Zhen-Zhen" last="Peng">Zhen-Zhen Peng</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000A61 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000A61 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:23733430
   |texte=   Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:23733430" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020