Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment

Identifieur interne : 000610 ( Pmc/Corpus ); précédent : 000609; suivant : 000611

A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment

Auteurs : Pâmela Cândida Aires Ribas De Andrade ; Leonardo Flores Luthi ; Kyle Stanley ; Antônio Carlos Cardoso

Source :

RBID : PMC:3881794

Abstract

Objective

The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator.

Material and methods

From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05).

Results

Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups.

Conclusion

Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds.


Url:
DOI: 10.1590/S1678-77572012000500004
PubMed: 23138736
PubMed Central: 3881794

Links to Exploration step

PMC:3881794

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment</title>
<author>
<name sortKey="De Andrade, Pamela Candida Aires Ribas" sort="De Andrade, Pamela Candida Aires Ribas" uniqKey="De Andrade P" first="Pâmela Cândida Aires Ribas" last="De Andrade">Pâmela Cândida Aires Ribas De Andrade</name>
<affiliation>
<nlm:aff id="aff01"> DDS, MSc, PhD student, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis, SC, Brazil.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Luthi, Leonardo Flores" sort="Luthi, Leonardo Flores" uniqKey="Luthi L" first="Leonardo Flores" last="Luthi">Leonardo Flores Luthi</name>
<affiliation>
<nlm:aff id="aff02"> DDS, MSc, PhD student, Department of Dental Materials and Prosthodontics, University of Campinas, Piracicaba School of Dentistry, Piracicaba, SP, Brazil.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Stanley, Kyle" sort="Stanley, Kyle" uniqKey="Stanley K" first="Kyle" last="Stanley">Kyle Stanley</name>
<affiliation>
<nlm:aff id="aff03"> MSc student, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis,SC, Brazil.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Cardoso, Antonio Carlos" sort="Cardoso, Antonio Carlos" uniqKey="Cardoso A" first="Antônio Carlos" last="Cardoso">Antônio Carlos Cardoso</name>
<affiliation>
<nlm:aff id="aff04"> DDS, MSc, PhD, Full Professor, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis, SC, Brazil.</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">23138736</idno>
<idno type="pmc">3881794</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3881794</idno>
<idno type="RBID">PMC:3881794</idno>
<idno type="doi">10.1590/S1678-77572012000500004</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">000610</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000610</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment</title>
<author>
<name sortKey="De Andrade, Pamela Candida Aires Ribas" sort="De Andrade, Pamela Candida Aires Ribas" uniqKey="De Andrade P" first="Pâmela Cândida Aires Ribas" last="De Andrade">Pâmela Cândida Aires Ribas De Andrade</name>
<affiliation>
<nlm:aff id="aff01"> DDS, MSc, PhD student, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis, SC, Brazil.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Luthi, Leonardo Flores" sort="Luthi, Leonardo Flores" uniqKey="Luthi L" first="Leonardo Flores" last="Luthi">Leonardo Flores Luthi</name>
<affiliation>
<nlm:aff id="aff02"> DDS, MSc, PhD student, Department of Dental Materials and Prosthodontics, University of Campinas, Piracicaba School of Dentistry, Piracicaba, SP, Brazil.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Stanley, Kyle" sort="Stanley, Kyle" uniqKey="Stanley K" first="Kyle" last="Stanley">Kyle Stanley</name>
<affiliation>
<nlm:aff id="aff03"> MSc student, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis,SC, Brazil.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Cardoso, Antonio Carlos" sort="Cardoso, Antonio Carlos" uniqKey="Cardoso A" first="Antônio Carlos" last="Cardoso">Antônio Carlos Cardoso</name>
<affiliation>
<nlm:aff id="aff04"> DDS, MSc, PhD, Full Professor, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis, SC, Brazil.</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of Applied Oral Science</title>
<idno type="ISSN">1678-7757</idno>
<idno type="eISSN">1678-7765</idno>
<imprint>
<date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Objective</title>
<p>The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. </p>
</sec>
<sec>
<title>Material and methods</title>
<p>From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05).</p>
</sec>
<sec>
<title>Results</title>
<p>Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups. </p>
</sec>
<sec>
<title>Conclusion</title>
<p>Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Barbosa, Ga" uniqKey="Barbosa G">GA Barbosa</name>
</author>
<author>
<name sortKey="Neves, Fd" uniqKey="Neves F">FD Neves</name>
</author>
<author>
<name sortKey="Mattos, Mg" uniqKey="Mattos M">MG Mattos</name>
</author>
<author>
<name sortKey="Rodrigues, Rc" uniqKey="Rodrigues R">RC Rodrigues</name>
</author>
<author>
<name sortKey="Ribeiro, Rf" uniqKey="Ribeiro R">RF Ribeiro</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Barret, Mg" uniqKey="Barret M">MG Barret</name>
</author>
<author>
<name sortKey="Rijk, Wg" uniqKey="Rijk W">WG Rijk</name>
</author>
<author>
<name sortKey="Burgess, Jo" uniqKey="Burgess J">JO Burgess</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Carr, Ab" uniqKey="Carr A">AB Carr</name>
</author>
<author>
<name sortKey="Gerard, Da" uniqKey="Gerard D">DA Gerard</name>
</author>
<author>
<name sortKey="Larsen, Pe" uniqKey="Larsen P">PE Larsen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Castilio, D" uniqKey="Castilio D">D Castilio</name>
</author>
<author>
<name sortKey="Pedreira, Ap" uniqKey="Pedreira A">AP Pedreira</name>
</author>
<author>
<name sortKey="Rossetti, Ph" uniqKey="Rossetti P">PH Rossetti</name>
</author>
<author>
<name sortKey="Rossetti, Lm" uniqKey="Rossetti L">LM Rossetti</name>
</author>
<author>
<name sortKey="Bonachela, Wc" uniqKey="Bonachela W">WC Bonachela</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Christensen, Jg" uniqKey="Christensen J">JG Christensen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Del Acqua Ma" uniqKey="Del Acqua Ma">Del'Acqua MA</name>
</author>
<author>
<name sortKey="Arioli Filho, Jn" uniqKey="Arioli Filho J">JN Arioli-Filho</name>
</author>
<author>
<name sortKey="Campagnoni, Ma" uniqKey="Campagnoni M">MA Campagnoni</name>
</author>
<author>
<name sortKey="Mollo, Fa" uniqKey="Mollo F">FA Mollo</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Hsu, Cc" uniqKey="Hsu C">CC Hsu</name>
</author>
<author>
<name sortKey="Millstein, Pl" uniqKey="Millstein P">PL Millstein</name>
</author>
<author>
<name sortKey="Stein, Rs" uniqKey="Stein R">RS Stein</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Inturregui, Ja" uniqKey="Inturregui J">JA Inturregui</name>
</author>
<author>
<name sortKey="Aquilino, Sa" uniqKey="Aquilino S">SA Aquilino</name>
</author>
<author>
<name sortKey="Ryther, Js" uniqKey="Ryther J">JS Ryther</name>
</author>
<author>
<name sortKey="Lund, Ps" uniqKey="Lund P">PS Lund</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
<author>
<name sortKey="Linden, B" uniqKey="Linden B">B Lindén</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Luthardt, Rg" uniqKey="Luthardt R">RG Luthardt</name>
</author>
<author>
<name sortKey="Walter, Mh" uniqKey="Walter M">MH Walter</name>
</author>
<author>
<name sortKey="Weber, A" uniqKey="Weber A">A Weber</name>
</author>
<author>
<name sortKey="Koch, R" uniqKey="Koch R">R Koch</name>
</author>
<author>
<name sortKey="Rudolph, H" uniqKey="Rudolph H">H Rudolph</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Moraes, Lm" uniqKey="Moraes L">LM Moraes</name>
</author>
<author>
<name sortKey="Rossetti, Ph" uniqKey="Rossetti P">PH Rossetti</name>
</author>
<author>
<name sortKey="Rossetti, Lm" uniqKey="Rossetti L">LM Rossetti</name>
</author>
<author>
<name sortKey="Pedreira, Ap" uniqKey="Pedreira A">AP Pedreira</name>
</author>
<author>
<name sortKey="Valle, Al" uniqKey="Valle A">AL Valle</name>
</author>
<author>
<name sortKey="Bonachela, Wc" uniqKey="Bonachela W">WC Bonachela</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Naveen, Hc" uniqKey="Naveen H">HC Naveen</name>
</author>
<author>
<name sortKey="Pillai, Lk" uniqKey="Pillai L">LK Pillai</name>
</author>
<author>
<name sortKey="Porwal, A" uniqKey="Porwal A">A Porwal</name>
</author>
<author>
<name sortKey="Nadiger, Rk" uniqKey="Nadiger R">RK Nadiger</name>
</author>
<author>
<name sortKey="Guttal, Ss" uniqKey="Guttal S">SS Guttal</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Podshadley, Ag" uniqKey="Podshadley A">AG Podshadley</name>
</author>
<author>
<name sortKey="Dilts, We" uniqKey="Dilts W">WE Dilts</name>
</author>
<author>
<name sortKey="Neiman, R" uniqKey="Neiman R">R Neiman</name>
</author>
<author>
<name sortKey="Sawyer, Hf" uniqKey="Sawyer H">HF Sawyer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sartori, Ia" uniqKey="Sartori I">IA Sartori</name>
</author>
<author>
<name sortKey="Ribeiro, Rf" uniqKey="Ribeiro R">RF Ribeiro</name>
</author>
<author>
<name sortKey="Franscischone, Ce" uniqKey="Franscischone C">CE Franscischone</name>
</author>
<author>
<name sortKey="Mattos, Mg" uniqKey="Mattos M">MG Mattos</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tossi, R" uniqKey="Tossi R">R Tossi</name>
</author>
<author>
<name sortKey="Falcao Filho, H" uniqKey="Falcao Filho H">H Falcão-Filho</name>
</author>
<author>
<name sortKey="Aguiar Junior, Fa" uniqKey="Aguiar Junior F">FA Aguiar Júnior</name>
</author>
<author>
<name sortKey="Rodrigues, Rc" uniqKey="Rodrigues R">RC Rodrigues</name>
</author>
<author>
<name sortKey="Mattos, Mg" uniqKey="Mattos M">MG Mattos</name>
</author>
<author>
<name sortKey="Ribeiro, Rf" uniqKey="Ribeiro R">RF Ribeiro</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Waskewicz, Ga" uniqKey="Waskewicz G">GA Waskewicz</name>
</author>
<author>
<name sortKey="Ostrowski, Js" uniqKey="Ostrowski J">JS Ostrowski</name>
</author>
<author>
<name sortKey="Parks, Vj" uniqKey="Parks V">VJ Parks</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Wee, Ag" uniqKey="Wee A">AG Wee</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Wenz, Hj" uniqKey="Wenz H">HJ Wenz</name>
</author>
<author>
<name sortKey="Hertrampf, K" uniqKey="Hertrampf K">K Hertrampf</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Yanase, Rt" uniqKey="Yanase R">RT Yanase</name>
</author>
<author>
<name sortKey="Binon, Pp" uniqKey="Binon P">PP Binon</name>
</author>
<author>
<name sortKey="Jemt, T" uniqKey="Jemt T">T Jemt</name>
</author>
<author>
<name sortKey="Gulbransen, Hj" uniqKey="Gulbransen H">HJ Gulbransen</name>
</author>
<author>
<name sortKey="Parel, S" uniqKey="Parel S">S Parel</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Appl Oral Sci</journal-id>
<journal-id journal-id-type="iso-abbrev">J Appl Oral Sci</journal-id>
<journal-id journal-id-type="publisher-id">J. Appl. Oral. Sci.</journal-id>
<journal-title-group>
<journal-title>Journal of Applied Oral Science</journal-title>
</journal-title-group>
<issn pub-type="ppub">1678-7757</issn>
<issn pub-type="epub">1678-7765</issn>
<publisher>
<publisher-name>Faculdade de Odontologia de Bauru da Universidade de São Paulo</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">23138736</article-id>
<article-id pub-id-type="pmc">3881794</article-id>
<article-id pub-id-type="doi">10.1590/S1678-77572012000500004</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Articles</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>de ANDRADE</surname>
<given-names>Pâmela Cândida Aires Ribas</given-names>
</name>
<xref ref-type="aff" rid="aff01">1</xref>
<xref ref-type="corresp" rid="c01"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>LUTHI</surname>
<given-names>Leonardo Flores</given-names>
</name>
<xref ref-type="aff" rid="aff02">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>STANLEY</surname>
<given-names>Kyle</given-names>
</name>
<xref ref-type="aff" rid="aff03">3</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>CARDOSO</surname>
<given-names>Antônio Carlos</given-names>
</name>
<xref ref-type="aff" rid="aff04">4</xref>
</contrib>
</contrib-group>
<aff id="aff01">
<label>1</label>
DDS, MSc, PhD student, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis, SC, Brazil.</aff>
<aff id="aff02">
<label>2</label>
DDS, MSc, PhD student, Department of Dental Materials and Prosthodontics, University of Campinas, Piracicaba School of Dentistry, Piracicaba, SP, Brazil.</aff>
<aff id="aff03">
<label>3</label>
MSc student, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis,SC, Brazil.</aff>
<aff id="aff04">
<label>4</label>
DDS, MSc, PhD, Full Professor, Department of Implant Dentistry, Federal University of Santa Catarina, Florianópolis, SC, Brazil.</aff>
<author-notes>
<corresp id="c01">
<bold>Corresponding address:</bold>
Pâmela Cândida Aires Ribas de Andrade - Universidade Federal de Santa Catarina/CCS/DEPTO STM - Campus Universitário, s/n - 88040-970 - Trindade - Florianópolis - SC - Phone: + 55 (48) 37219077 / + 55 (48) 91645150 - Fax: (48) 3721-9077 - e-mail:
<email>pam_ribas@yahoo.com.br</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<season>Sep-Oct</season>
<year>2012</year>
</pub-date>
<volume>20</volume>
<issue>5</issue>
<fpage>517</fpage>
<lpage>521</lpage>
<history>
<date date-type="received">
<day>26</day>
<month>5</month>
<year>2011</year>
</date>
<date date-type="rev-recd">
<day>04</day>
<month>8</month>
<year>2011</year>
</date>
<date date-type="accepted">
<day>05</day>
<month>9</month>
<year>2011</year>
</date>
</history>
<permissions>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">
<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
<abstract>
<sec>
<title>Objective</title>
<p>The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. </p>
</sec>
<sec>
<title>Material and methods</title>
<p>From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05).</p>
</sec>
<sec>
<title>Results</title>
<p>Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups. </p>
</sec>
<sec>
<title>Conclusion</title>
<p>Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds.</p>
</sec>
</abstract>
<kwd-group>
<kwd>Plaster casts</kwd>
<kwd>Implant-supported dental prosthesis</kwd>
<kwd>Dental impression materials</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec>
<title>INTRODUCTION</title>
<p>The oral rehabilitation of patients with implants requires the placement of stable prostheses enabling security, comfort and longevity to treatment. The beginning of the construction of prosthetic treatment requires the faithful reproduction of the working cast of the situation found in mouth, to reduce the errors inherent to this stage
<sup>
<xref ref-type="bibr" rid="r17">17</xref>
</sup>
.</p>
<p>Numerous studies
<sup>
<xref ref-type="bibr" rid="r02">2</xref>
,
<xref ref-type="bibr" rid="r08">8</xref>
,
<xref ref-type="bibr" rid="r09">9</xref>
,
<xref ref-type="bibr" rid="r19">19</xref>
</sup>
have tried to find the "perfect" fit between prosthetic components and the implant. However, the variables found in the steps of the clinical and laboratory procedures involved in the fabrication prostheses become an obstacle in the search for a perfect fit
<sup>
<xref ref-type="bibr" rid="r07">7</xref>
</sup>
, leading to errors that make it impossible to obtain a dental implant with a perfect framework fit
<sup>
<xref ref-type="bibr" rid="r12">12</xref>
</sup>
.</p>
<p>During the production stages of a cast, some processes may influence the correct analogue position of the working cast, increasing the chances of distortion and misfit of the final prosthesis
<sup>
<xref ref-type="bibr" rid="r06">6</xref>
</sup>
. The casting material used
<sup>
<xref ref-type="bibr" rid="r02">2</xref>
</sup>
, the casting technique
<sup>
<xref ref-type="bibr" rid="r02">2</xref>
,
<xref ref-type="bibr" rid="r07">7</xref>
,
<xref ref-type="bibr" rid="r11">11</xref>
</sup>
and the casting impression conditions are factors that can influence the accurate reproduction of the clinical situation
<sup>
<xref ref-type="bibr" rid="r18">18</xref>
</sup>
.</p>
<p>Another important aspect to be considered is the step of sending the molds to the laboratory. A study by Christensen
<sup>
<xref ref-type="bibr" rid="r05">5</xref>
</sup>
(1997) demonstrated that most jobs ready to be poured with gypsum were deficient in some aspect
<sup>
<xref ref-type="bibr" rid="r06">6</xref>
</sup>
. The literature
<sup>
<xref ref-type="bibr" rid="r02">2</xref>
,
<xref ref-type="bibr" rid="r07">7</xref>
,
<xref ref-type="bibr" rid="r11">11</xref>
</sup>
, although large and concerned with the techniques and impression materials, is scarce when dealing with the variables of everyday practice. A small number of studies focused on the influence of factors such as casting of the plaster cast
<sup>
<xref ref-type="bibr" rid="r14">14</xref>
</sup>
or the technique for casting on dimensional changes of the casts.</p>
<p>In an attempt to minimize distortions in the procedures for obtaining a working cast, improve the accuracy of implant prostheses and assist dentists, we developed a small, silent and portable vibrator. We hypothesized that this device would be able to reduce the vibration generated by conventional devices, thus leading to fewer changes in the working cast, better adaptation between the cylinders of implant-supported dentures and their respective analogues. This would result in a more faithful copy of the situation in the mouth, with minimal bubbles and dimensional change in the working cast.</p>
<p>The purposes of this study were to test the technique of casting plaster using this portable vibrator device, comparing it with conventional methods, and to evaluate the influence of this device on the position of implant analogue working casts.</p>
</sec>
<sec sec-type="materials|methods">
<title>MATERIAL AND METHODS</title>
<p>A master acrylic resin template (Palaton - Dencril, Pirassununga, SP, Brazil) of a Class IV edentulous maxillary arch, with two external hexagonal implants Ø 3.75x11 mm (Master Screw; Conexão Sistemas de Próteses, São Paulo, SP, Brazil) positioned in the region of the maxillary right lateral incisor (A) and maxillary left lateral incisor (B) was manufactured for the study design (
<xref ref-type="fig" rid="f01">Figure 1</xref>
). Two abutments (Micro-unit; Conexão Sistemas de Próteses, Arujá, SP, Brazil) were installed by manual ratchet key until a torque of 20 N.cm was produced according to the manufacturer's directions and 30 transfer moldings were made with open trays. This cast was then randomly divided into three groups, depending on the plaster casting technique:</p>
<fig id="f01" orientation="portrait" position="float">
<label>Figure 1</label>
<caption>
<p>Step-by-step fabrication of the portable device designed to casting plaster (a): electric toothbrush; (b): bristles of the brush removed; (c): hole on tip of the toothbrush in place of the bristles; (d): installation of the tip of a brush on the opposite side of the bristles and (e): portable vibrator ready</p>
</caption>
<graphic xlink:href="jaos-20-05-0517-g01"></graphic>
</fig>
<p>Group I (GI):pouring performed at an outsourced dental laboratory with conventional plaster vibrator (10 casts);</p>
<p>Group II (GII):pouring performed at UFSC laboratory with conventional plaster vibrator (10 casts);</p>
<p>Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts).</p>
<p>To make the impressions, standard size (no. 3) perforated plastic trays were used (JG, JON, São Paulo, SP, Brazil), with an opening at the top of two holes designed for the removal of screws for transferring squares. The material of choice for the impression was polyvinyl siloxane (PVS) (Express XT Silicone Addition, 3M ESPE, USA)
<sup>
<xref ref-type="bibr" rid="r19">19</xref>
</sup>
and manipulation was done by the single step double impression technique
<sup>
<xref ref-type="bibr" rid="r07">7</xref>
,
<xref ref-type="bibr" rid="r11">11</xref>
</sup>
. The transfer copings were screwed in their abutments in the master cast and splinted together with a metal rod and acrylic pattern resin (Trim Plus Red - Acrylic Pattern; Harry J. Bosworth Company, Skokie, IL, USA)
<sup>
<xref ref-type="bibr" rid="r09">9</xref>
</sup>
, reducing the distortion of polymerization. After 10 min of union with transferring acrylic resin, heavy-body PVS was handled according to the manufacturer's instructions and the tray was loaded with the material, while light-body PVS was injected into the region of the implants and their components. To standardize the molding, heavy-body PVS was measured in a plastic syringe injector for elastomer (JON) filled with slurry by cast. Setting of the dummy tray was held constant with manual pressure until it clicked into a reference point located on the mannequin, then held in position for 10 min to complete polymerization of the material. All impressions were made in the same temperature-controlled air conditioning between 18ºC and 22ºC. After the mold was ready, the transfer copings were loosened to remove the impression and screwed to the respective analogues of the abutments (Conexão Sistemas de Próteses). For all transfer copings a torque of 10 N.cm was applied manually with a keyed ratchet (Conexão Sistemas de Próteses), but the placement of analogues was performed with a digital grip, because the torque applied by a 10 N.cm ratchet could cause rotation of the transferor PVS
<sup>
<xref ref-type="bibr" rid="r02">2</xref>
,
<xref ref-type="bibr" rid="r08">8</xref>
</sup>
. Adaptation of impressions prior to the tightening grip and digital analogue was again verified by the transferor with explorer no. 05 (Duflex SS White, Rio de Janeiro, RJ, Brazil).</p>
<p>When the impressions were ready, with the union of the analogues, they were randomly assigned to groups according to the technique of casting plaster. The 30 plaster casts used microgranulated special type IV plaster (Durone, Dentisply, Petrópolis, RJ, Brazil), and pouring was conducted in an area for at least 60 min and at most 3 days after the order was ready.</p>
<sec>
<title>Fabricating the portable vibrator</title>
<p>For casting plaster of Group III, we developed a portable vibrator made from an electric toothbrush (360º Sonic Power, Colgate Palmolive Ind. e Com. São Paulo, SP, Brazil). The bristles of the brush were removed using a carborundum disk-type cutter and maxi-cut, and a hole in the place of the bristles was made for installation of the tip of a brush on the opposite side (round marta brush Tropical 006, Tigre, São Paulo, SP, Brazil), maintaining a slight inclination toward the end to facilitate placement of the plaster inside the impression (
<xref ref-type="fig" rid="f01">Figure 1</xref>
).</p>
</sec>
<sec>
<title>Casting molds for Group I</title>
<p>Ten impressions were sent to the outsourced laboratory, in a routine procedure for work on prosthetic implants. Along with the impressions, an order tab was included with the request for plaster casting of special type IV, for a minimum standardization with the other groups.</p>
</sec>
<sec>
<title>Casting molds for Groups II and III</title>
<p>The casts of Groups II and III were poured with 100 g of powder type IV gypsum, proportioned to 22 mL of water
<sup>
<xref ref-type="bibr" rid="r06">6</xref>
,
<xref ref-type="bibr" rid="r08">8</xref>
</sup>
and hand-mixed for 60 s. Insertion of the plaster cast was performed according to the technique assigned to each group, with Group II using the leaked vibrator with conventional casting and Group III with the portable vibrator. After a period of at least 1 h of setting time for the plaster, the working casts were removed from the mold. All casts were stored at room temperature for at least 92 h before assessment of misfit
<sup>
<xref ref-type="bibr" rid="r08">8</xref>
</sup>
. To standardize the samples, all steps of molding, tooling, and casting of plaster were made by the researcher in charge, while handling the PVS was done by an assistant operator.</p>
</sec>
<sec>
<title>Evaluation of discrepancies in the position of casts and analogues</title>
<p>Verification of the accuracy of the position of analogues and comparison between groups was performed to develop an infrastructure (IE) from two metal cylinders of titanium abutment micro-unit, bolted to the abutment of the master cast (MC) and joined together by a titanium bar and laser welding
<sup>
<xref ref-type="bibr" rid="r10">10</xref>
</sup>
.</p>
<p>To calculate the misfit of the casts and make comparisons between groups, we measured the vertical misfit of IE in the MC to verify the reliability of the adaptation and the value of the initial IE misfit
<sup>
<xref ref-type="bibr" rid="r20">20</xref>
</sup>
. Then, the evaluations also were carried out in testing casts (TC) of Groups I, II, and III, with IE placed on them, whose respective averages were subtracted from the initial value obtained for MC in order to obtain the real misfit value. The implants of MC and related analogues of the tested casts were recorded as A and B, from left to right, as with the cylinders of IE. Evaluation of misfit was based on the protocol of tightening the screw only to test the passivity of the implant structures
<sup>
<xref ref-type="bibr" rid="r15">15</xref>
</sup>
, which had the grip of a retainer and evaluation of the contrary retainer
<sup>
<xref ref-type="bibr" rid="r15">15</xref>
</sup>
(
<xref ref-type="fig" rid="f02">Figure 2</xref>
).</p>
<fig id="f02" orientation="portrait" position="float">
<label>Figure 2</label>
<caption>
<p>Infrastructure placed on the master cast (MC) (a) and the test cast (TC) (b) to test the single screw</p>
</caption>
<graphic xlink:href="jaos-20-05-0517-g02"></graphic>
</fig>
<p>The misfit was measured at 120x magnification in a measuring microscope accurate to 1.0 µm (UHL MM-100-BT, UK), equipped with a digital camera (KC-512NT; Kodo BR Electronics Ltd., São Paulo, SP, Brazil) and analyzer unit (QC 220-HH Quadra-Check 200; Metronics Inc., Bedford, NH, USA). The casts were placed randomly under the microscope so that the blind evaluator did not know to which group they belonged. All casts were evaluated at identical points and cylinders A and B of IE were marked with a carborundum disk Ø 75x0.2 mm on the handpiece.</p>
<p>The readings were performed by an examiner on two calibrated points on the buccal (1 and 2) and two in the lingual face (3 and 4), ordered from left to right. The sequence of assessment was followed by the tightening of the screw in the implant B with 10 N.cm and measuring the distance in micrometers (µm) of 1-4 points on the interface of the cylinder to the abutment/analogue interface, identifying the considered misfit (
<xref ref-type="fig" rid="f03">Figure 3</xref>
). The same procedure was then performed for B. Each point was measured three times and the average value used for the analysis.</p>
<fig id="f03" orientation="portrait" position="float">
<label>Figure 3</label>
<caption>
<p>Microscopic image of the misfit generated at the interface of one point</p>
</caption>
<graphic xlink:href="jaos-20-05-0517-g03"></graphic>
</fig>
</sec>
<sec>
<title>Statistical analysis</title>
<p>Means and standard deviations for each plaster casting technique were calculated and analyzed by one-way ANOVA to determine whether there were significant differences between groups, at α=0.05. After ANOVA, data were subjected to Holm-Sidak multiple comparison test, which identified the p values. The software used was Sigmastat 3.5 (Systat Software, Inc., Chicago, IL, USA).</p>
</sec>
</sec>
<sec sec-type="results">
<title>RESULTS</title>
<p>Data analysis revealed a statistically significant difference between Group III as compared to Groups I and II (p<0.001) (
<xref ref-type="fig" rid="f04">Figure 4</xref>
). This means that the technique of casting the plaster with a portable vibrator produces a smaller misfit between cylinders of implant-supported dentures and their respective analogues in comparison with the conventional techniques for casting plaster.</p>
<fig id="f04" orientation="portrait" position="float">
<label>Figure 4</label>
<caption>
<p>Means and standard deviations(SD) of the misfit (μm) for the three groups. *statistically significant difference in comparison with the other groups (p<0.05)</p>
</caption>
<graphic xlink:href="jaos-20-05-0517-g04"></graphic>
</fig>
</sec>
<sec sec-type="discussion">
<title>DISCUSSION</title>
<p>For the construction of a fixed partial denture on implants, several steps must be followed to reduce errors and obtain a clinically acceptable product. According to dental knowledge, the larger the number of pontics and retainers in prosthesis, the greater the chances of mismatch. Since the installation of the abutment to the working model, there are countless chances of errors
<sup>
<xref ref-type="bibr" rid="r02">2</xref>
,
<xref ref-type="bibr" rid="r05">5</xref>
-
<xref ref-type="bibr" rid="r07">7</xref>
,
<xref ref-type="bibr" rid="r11">11</xref>
,
<xref ref-type="bibr" rid="r18">18</xref>
</sup>
. Also, the fact that the analogues are screwed to the implant makes them susceptible to displacement, especially during vibration of plaster during pouring.</p>
<p>This work aimed to check the effectiveness of a new portable vibrator on the plaster pouring of implant-supported dentures, also to verify if this device reduces the possibility of misfit between cylinders of implant-supported dentures and their respective analogues. The results of the present work showed that the portable vibrator led to lower misfit values between cylinders of implant-supported dentures and their respective analogues when compared to conventional vibrator. A minimum misfit was found when using the new vibrator, but the "perfect" adaptation is almost impossible to reach
<sup>
<xref ref-type="bibr" rid="r20">20</xref>
</sup>
.</p>
<p>Extrapolating to clinical results of acceptable misfit of an implant-supported prosthesis, the literature
<sup>
<xref ref-type="bibr" rid="r03">3</xref>
,
<xref ref-type="bibr" rid="r16">16</xref>
</sup>
is unable to show an ideal value of adjustment that will not jeopardize the entire system for prosthetic reconstruction. According to Tossi
<sup>
<xref ref-type="bibr" rid="r16">16</xref>
</sup>
(2010) values of marginal fit between frameworks to multiple-units are clinically acceptable within 150 µm range
<sup>
<xref ref-type="bibr" rid="r16">16</xref>
</sup>
. Carr
<sup>
<xref ref-type="bibr" rid="r03">3</xref>
</sup>
(1996) in an
<italic>in vivo</italic>
study on primates verified that there is no statistically significant difference in bone response around the implants supporting frameworks with 38 µm and 345 µm misfits
<sup>
<xref ref-type="bibr" rid="r03">3</xref>
</sup>
.</p>
<p>According to literature
<sup>
<xref ref-type="bibr" rid="r01">1</xref>
,
<xref ref-type="bibr" rid="r04">4</xref>
,
<xref ref-type="bibr" rid="r12">12</xref>
</sup>
the marginal misfit can be influenced by the technique
<sup>
<xref ref-type="bibr" rid="r01">1</xref>
</sup>
and by the material
<sup>
<xref ref-type="bibr" rid="r04">4</xref>
,
<xref ref-type="bibr" rid="r12">12</xref>
</sup>
used to fabricate the frameworks. However, this research suggests that the vibration is also an important factor at this point, reminding that it refers to just one of many steps that are required to get a prosthetic piece. During the other steps required to complete prosthesis fabrication, such as firing porcelain several times and finishing
<sup>
<xref ref-type="bibr" rid="r13">13</xref>
</sup>
done by a laboratory technician, misfit values will be further enhanced, thus emphasizing the importance of using laboratory techniques and devices that decrease the possibility of distortion in the final piece.</p>
<p>The new portable vibrator not only contributes to decrease the misfit, but also has the advantage of being a small, soundless and low-cost device.</p>
</sec>
<sec sec-type="conclusions">
<title>CONCLUSION</title>
<p>The casting technique using the portable vibrator allowed a smaller misfit between the cylinders of implant-supported dentures and their respective analogues than the conventional plaster vibrator.</p>
</sec>
</body>
<back>
<ack>
<sec>
<title>ACKNOWLEDGMENTS</title>
<p>The author would like to thank Dr. Guilherme Elias Pessanha Henriques and Dr. Mauru Antônio Arruda Nóbilo, Professors of Dentistry at the University of Campinas, SP, Brazil for his contribution and support to this work.</p>
</sec>
</ack>
<ref-list>
<title>REFERENCES</title>
<ref id="r01">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barbosa</surname>
<given-names>GA</given-names>
</name>
<name>
<surname>Neves</surname>
<given-names>FD</given-names>
</name>
<name>
<surname>Mattos</surname>
<given-names>MG</given-names>
</name>
<name>
<surname>Rodrigues</surname>
<given-names>RC</given-names>
</name>
<name>
<surname>Ribeiro</surname>
<given-names>RF</given-names>
</name>
</person-group>
<article-title>Implant/abutment vertical misfit of one-piece cast frameworks made with different materials</article-title>
<source>Braz Dent J</source>
<year>2010</year>
<volume>21</volume>
<fpage>515</fpage>
<lpage>519</lpage>
<pub-id pub-id-type="pmid">21271041</pub-id>
</element-citation>
</ref>
<ref id="r02">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barret</surname>
<given-names>MG</given-names>
</name>
<name>
<surname>Rijk</surname>
<given-names>WG</given-names>
</name>
<name>
<surname>Burgess</surname>
<given-names>JO</given-names>
</name>
</person-group>
<article-title>The accuracy of six impression techniques for osseointegrated implants</article-title>
<source>J Prosthodont</source>
<year>1993</year>
<volume>2</volume>
<fpage>275</fpage>
<lpage>282</lpage>
</element-citation>
</ref>
<ref id="r03">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Carr</surname>
<given-names>AB</given-names>
</name>
<name>
<surname>Gerard</surname>
<given-names>DA</given-names>
</name>
<name>
<surname>Larsen</surname>
<given-names>PE</given-names>
</name>
</person-group>
<article-title>The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit</article-title>
<source>J Prosthet Dent</source>
<year>1996</year>
<volume>76</volume>
<fpage>500</fpage>
<lpage>509</lpage>
<pub-id pub-id-type="pmid">8933440</pub-id>
</element-citation>
</ref>
<ref id="r04">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Castilio</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Pedreira</surname>
<given-names>AP</given-names>
</name>
<name>
<surname>Rossetti</surname>
<given-names>PH</given-names>
</name>
<name>
<surname>Rossetti</surname>
<given-names>LM</given-names>
</name>
<name>
<surname>Bonachela</surname>
<given-names>WC</given-names>
</name>
</person-group>
<article-title>The influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding</article-title>
<source>J Appl Oral Sci</source>
<year>2006</year>
<volume>14</volume>
<fpage>77</fpage>
<lpage>81</lpage>
<pub-id pub-id-type="pmid">19089035</pub-id>
</element-citation>
</ref>
<ref id="r05">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Christensen</surname>
<given-names>JG</given-names>
</name>
</person-group>
<article-title>What category of impression material is best for your practice?</article-title>
<source>J Am Dent Assoc</source>
<year>1997</year>
<volume>128</volume>
<fpage>1026</fpage>
<lpage>1028</lpage>
<pub-id pub-id-type="pmid">9231610</pub-id>
</element-citation>
</ref>
<ref id="r06">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Del'Acqua MA</surname>
</name>
<name>
<surname>Arioli-Filho</surname>
<given-names>JN</given-names>
</name>
<name>
<surname>Campagnoni</surname>
<given-names>MA</given-names>
</name>
<name>
<surname>Mollo</surname>
<given-names>FA</given-names>
<suffix>Jr</suffix>
</name>
</person-group>
<article-title>Accuracy of impression and pouring techniques for an implantsupported prosthesis</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>2008</year>
<volume>23</volume>
<fpage>226</fpage>
<lpage>236</lpage>
<pub-id pub-id-type="pmid">18548918</pub-id>
</element-citation>
</ref>
<ref id="r07">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hsu</surname>
<given-names>CC</given-names>
</name>
<name>
<surname>Millstein</surname>
<given-names>PL</given-names>
</name>
<name>
<surname>Stein</surname>
<given-names>RS</given-names>
</name>
</person-group>
<article-title>A comparative analysis of the accuracy of implant transfer techniques</article-title>
<source>J Prosthet Dent</source>
<year>1993</year>
<volume>69</volume>
<fpage>588</fpage>
<lpage>593</lpage>
<pub-id pub-id-type="pmid">8320644</pub-id>
</element-citation>
</ref>
<ref id="r08">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Inturregui</surname>
<given-names>JA</given-names>
</name>
<name>
<surname>Aquilino</surname>
<given-names>SA</given-names>
</name>
<name>
<surname>Ryther</surname>
<given-names>JS</given-names>
</name>
<name>
<surname>Lund</surname>
<given-names>PS</given-names>
</name>
</person-group>
<article-title>Evaluation of three techniques for osseointegrated oral implants</article-title>
<source>J Prosthet Dent</source>
<year>1993</year>
<volume>69</volume>
<fpage>503</fpage>
<lpage>509</lpage>
<pub-id pub-id-type="pmid">8483130</pub-id>
</element-citation>
</ref>
<ref id="r09">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>
<italic>In vivo</italic>
measurements of precision of fit involving implant-supported prostheses in the edentulous jaw</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>1996</year>
<volume>11</volume>
<fpage>151</fpage>
<lpage>158</lpage>
<pub-id pub-id-type="pmid">8666445</pub-id>
</element-citation>
</ref>
<ref id="r10">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Lindén</surname>
<given-names>B</given-names>
</name>
</person-group>
<article-title>Fixed implant-supported prostheses with welded titanium frameworks</article-title>
<source>Int J Periodontics Restorative Dent</source>
<year>1992</year>
<volume>12</volume>
<fpage>177</fpage>
<lpage>184</lpage>
<pub-id pub-id-type="pmid">1363939</pub-id>
</element-citation>
</ref>
<ref id="r11">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Luthardt</surname>
<given-names>RG</given-names>
</name>
<name>
<surname>Walter</surname>
<given-names>MH</given-names>
</name>
<name>
<surname>Weber</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Koch</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Rudolph</surname>
<given-names>H</given-names>
</name>
</person-group>
<article-title>Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial</article-title>
<source>Int J Prosthodont</source>
<year>2008</year>
<volume>21</volume>
<fpage>322</fpage>
<lpage>327</lpage>
<pub-id pub-id-type="pmid">18717091</pub-id>
</element-citation>
</ref>
<ref id="r12">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Moraes</surname>
<given-names>LM</given-names>
</name>
<name>
<surname>Rossetti</surname>
<given-names>PH</given-names>
</name>
<name>
<surname>Rossetti</surname>
<given-names>LM</given-names>
</name>
<name>
<surname>Pedreira</surname>
<given-names>AP</given-names>
</name>
<name>
<surname>Valle</surname>
<given-names>AL</given-names>
</name>
<name>
<surname>Bonachela</surname>
<given-names>WC</given-names>
</name>
</person-group>
<article-title>Marginal fit at cylinder-abutment interface before and after overcasting procedure</article-title>
<source>J Appl Oral Sci</source>
<year>2005</year>
<volume>13</volume>
<fpage>366</fpage>
<lpage>371</lpage>
<pub-id pub-id-type="pmid">20865221</pub-id>
</element-citation>
</ref>
<ref id="r13">
<label>13</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Naveen</surname>
<given-names>HC</given-names>
</name>
<name>
<surname>Pillai</surname>
<given-names>LK</given-names>
</name>
<name>
<surname>Porwal</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Nadiger</surname>
<given-names>RK</given-names>
</name>
<name>
<surname>Guttal</surname>
<given-names>SS</given-names>
</name>
</person-group>
<article-title>Effect of porcelain-firing cycles and surface finishing on the marginal discrepancy of titanium copings</article-title>
<source>J Prosthodont</source>
<year>2011</year>
<volume>20</volume>
<fpage>101</fpage>
<lpage>105</lpage>
<pub-id pub-id-type="pmid">21261776</pub-id>
</element-citation>
</ref>
<ref id="r14">
<label>14</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Podshadley</surname>
<given-names>AG</given-names>
</name>
<name>
<surname>Dilts</surname>
<given-names>WE</given-names>
</name>
<name>
<surname>Neiman</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Sawyer</surname>
<given-names>HF</given-names>
</name>
</person-group>
<article-title>Accuracy of a mercaptan rubber impression technique using a stock tray</article-title>
<source>J Am Dent Assoc</source>
<year>1971</year>
<volume>83</volume>
<fpage>1303</fpage>
<lpage>1308</lpage>
<pub-id pub-id-type="pmid">4940403</pub-id>
</element-citation>
</ref>
<ref id="r15">
<label>15</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sartori</surname>
<given-names>IA</given-names>
</name>
<name>
<surname>Ribeiro</surname>
<given-names>RF</given-names>
</name>
<name>
<surname>Franscischone</surname>
<given-names>CE</given-names>
</name>
<name>
<surname>Mattos</surname>
<given-names>MG</given-names>
</name>
</person-group>
<article-title>
<italic>In vitro</italic>
comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion</article-title>
<source>J Prosthet Dent</source>
<year>2004</year>
<volume>92</volume>
<fpage>132</fpage>
<lpage>138</lpage>
<pub-id pub-id-type="pmid">15295321</pub-id>
</element-citation>
</ref>
<ref id="r16">
<label>16</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tossi</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Falcão-Filho</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Aguiar Júnior</surname>
<given-names>FA</given-names>
</name>
<name>
<surname>Rodrigues</surname>
<given-names>RC</given-names>
</name>
<name>
<surname>Mattos</surname>
<given-names>MG</given-names>
</name>
<name>
<surname>Ribeiro</surname>
<given-names>RF</given-names>
</name>
</person-group>
<article-title>Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks</article-title>
<source>J Oral Rehabil</source>
<year>2010</year>
<volume>37</volume>
<fpage>359</fpage>
<lpage>363</lpage>
<pub-id pub-id-type="pmid">20149062</pub-id>
</element-citation>
</ref>
<ref id="r17">
<label>17</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Waskewicz</surname>
<given-names>GA</given-names>
</name>
<name>
<surname>Ostrowski</surname>
<given-names>JS</given-names>
</name>
<name>
<surname>Parks</surname>
<given-names>VJ</given-names>
</name>
</person-group>
<article-title>Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>1994</year>
<volume>9</volume>
<fpage>405</fpage>
<lpage>411</lpage>
</element-citation>
</ref>
<ref id="r18">
<label>18</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wee</surname>
<given-names>AG</given-names>
</name>
</person-group>
<article-title>Comparison of impression materials for direct multiimplant impressions</article-title>
<source>J Prosthet Dent</source>
<year>2000</year>
<volume>83</volume>
<fpage>323</fpage>
<lpage>331</lpage>
<pub-id pub-id-type="pmid">10709042</pub-id>
</element-citation>
</ref>
<ref id="r19">
<label>19</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wenz</surname>
<given-names>HJ</given-names>
</name>
<name>
<surname>Hertrampf</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>2008</year>
<volume>23</volume>
<fpage>39</fpage>
<lpage>47</lpage>
<pub-id pub-id-type="pmid">18416411</pub-id>
</element-citation>
</ref>
<ref id="r20">
<label>20</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yanase</surname>
<given-names>RT</given-names>
</name>
<name>
<surname>Binon</surname>
<given-names>PP</given-names>
</name>
<name>
<surname>Jemt</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Gulbransen</surname>
<given-names>HJ</given-names>
</name>
<name>
<surname>Parel</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>How do you test a cast framework fit for a full-arch fixed implant-supported prosthesis</article-title>
<source>Int J Oral Maxillofac Implants</source>
<year>1994</year>
<volume>9</volume>
<fpage>469</fpage>
<lpage>474</lpage>
</element-citation>
</ref>
</ref-list>
</back>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000610 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000610 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3881794
   |texte=   A new portable vibrator for plaster pouring: effect on the marginal fit
at cylinder-abutment
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:23138736" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020