Effect of Platelet-Rich-Plasma (PRP) and Implant Surface Topography on Implant Stability and Bone
Identifieur interne : 000337 ( Pmc/Corpus ); précédent : 000336; suivant : 000338Effect of Platelet-Rich-Plasma (PRP) and Implant Surface Topography on Implant Stability and Bone
Auteurs : Renu Kundu ; Manu RatheeSource :
- Journal of Clinical and Diagnostic Research : JCDR [ 2249-782X ] ; 2014.
Abstract
Url:
DOI: 10.7860/JCDR/2014/9177.4478
PubMed: 25121060
PubMed Central: 4129334
Links to Exploration step
PMC:4129334Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Effect of Platelet-Rich-Plasma (PRP) and Implant Surface Topography on Implant Stability and Bone</title>
<author><name sortKey="Kundu, Renu" sort="Kundu, Renu" uniqKey="Kundu R" first="Renu" last="Kundu">Renu Kundu</name>
<affiliation><nlm:aff id="aff1"> Post Graduate Student, Department of Prosthodontics,<institution>Post Graduate Institute of Dental Sciences, Pt. B.D. Sharma University of Health Sciences</institution>
,<addr-line>Rohtak, Haryana, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author><name sortKey="Rathee, Manu" sort="Rathee, Manu" uniqKey="Rathee M" first="Manu" last="Rathee">Manu Rathee</name>
<affiliation><nlm:aff id="aff2"> Senior Professor and Head, Department of Prosthodontics,<institution>Post Graduate Institute of Dental Sciences, Pt. B.D. Sharma University of Health Sciences</institution>
,<addr-line>Rohtak, Haryana, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PMC</idno>
<idno type="pmid">25121060</idno>
<idno type="pmc">4129334</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4129334</idno>
<idno type="RBID">PMC:4129334</idno>
<idno type="doi">10.7860/JCDR/2014/9177.4478</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">000337</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000337</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a" type="main">Effect of Platelet-Rich-Plasma (PRP) and Implant Surface Topography on Implant Stability and Bone</title>
<author><name sortKey="Kundu, Renu" sort="Kundu, Renu" uniqKey="Kundu R" first="Renu" last="Kundu">Renu Kundu</name>
<affiliation><nlm:aff id="aff1"> Post Graduate Student, Department of Prosthodontics,<institution>Post Graduate Institute of Dental Sciences, Pt. B.D. Sharma University of Health Sciences</institution>
,<addr-line>Rohtak, Haryana, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author><name sortKey="Rathee, Manu" sort="Rathee, Manu" uniqKey="Rathee M" first="Manu" last="Rathee">Manu Rathee</name>
<affiliation><nlm:aff id="aff2"> Senior Professor and Head, Department of Prosthodontics,<institution>Post Graduate Institute of Dental Sciences, Pt. B.D. Sharma University of Health Sciences</institution>
,<addr-line>Rohtak, Haryana, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
</analytic>
<series><title level="j">Journal of Clinical and Diagnostic Research : JCDR</title>
<idno type="ISSN">2249-782X</idno>
<idno type="eISSN">0973-709X</idno>
<imprint><date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en"><p><bold>Purpose:</bold>
To evaluate the effect of Platelet-Rich-Plasma (PRP) and different implant surface topography on implant stability and bone levels around immediately loaded dental implants.</p>
<p><bold>Materials and Methods:</bold>
Dental implants were placed in subjects divided into two groups and four subgroups on basis of implant treatment with PRP and implant surface topography used. A total of 30 implants were placed, 15 in each group. For PRP group, implants were placed after surface treatment with PRP. Temporization was done within two weeks and final prosthesis was given after three months. Implant stability was measured with Periotest at baseline, one month and three months. Bone height was measured on mesial & distal side on standardized IOPA x-rays.</p>
<p><bold>Results:</bold>
A statistically significant difference was noticed in implant stability with PRP at baseline. The effect of PRP on bone height changes was not statistically significant. A synergistic effect of PRP and square thread-form was observed on improved implant stability and bone levels; however, no such effect is seen with PRP and reverse buttress thread-form.</p>
<p><bold>Conclusion:</bold>
Within the limitation of this study, enhancement on implant stability and bone healing was observed with PRP treated implant surfaces, and with use of implant with square thread-form.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article"><pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front><journal-meta><journal-id journal-id-type="nlm-ta">J Clin Diagn Res</journal-id>
<journal-id journal-id-type="iso-abbrev">J Clin Diagn Res</journal-id>
<journal-id journal-id-type="hwp">Journal of Clinical and Diagnostic Research</journal-id>
<journal-id journal-id-type="publisher-id">JCDR</journal-id>
<journal-title-group><journal-title>Journal of Clinical and Diagnostic Research : JCDR</journal-title>
</journal-title-group>
<issn pub-type="ppub">2249-782X</issn>
<issn pub-type="epub">0973-709X</issn>
<publisher><publisher-name>JCDR Research and Publications (P) Limited</publisher-name>
<publisher-loc>Delhi, India</publisher-loc>
</publisher>
</journal-meta>
<article-meta><article-id pub-id-type="pmid">25121060</article-id>
<article-id pub-id-type="pmc">4129334</article-id>
<article-id pub-id-type="doi">10.7860/JCDR/2014/9177.4478</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Dentistry</subject>
<subj-group subj-group-type="heading"><subject>Dental Original Article</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group><article-title>Effect of Platelet-Rich-Plasma (PRP) and Implant Surface Topography on Implant Stability and Bone</article-title>
</title-group>
<contrib-group><contrib contrib-type="author"><name><surname>Kundu</surname>
<given-names>Renu</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Rathee</surname>
<given-names>Manu</given-names>
</name>
<xref ref-type="aff" rid="aff2">2</xref>
<xref ref-type="corresp" rid="cor1"></xref>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label>
Post Graduate Student, Department of Prosthodontics,<institution>Post Graduate Institute of Dental Sciences, Pt. B.D. Sharma University of Health Sciences</institution>
,<addr-line>Rohtak, Haryana, India</addr-line>
.</aff>
<aff id="aff2"><label>2</label>
Senior Professor and Head, Department of Prosthodontics,<institution>Post Graduate Institute of Dental Sciences, Pt. B.D. Sharma University of Health Sciences</institution>
,<addr-line>Rohtak, Haryana, India</addr-line>
.</aff>
<author-notes><corresp id="cor1">NAME, ADDRESS, E-MAIL ID OF THE CORRESPONDING AUTHOR: Dr. Manu Rathee, Senior Professor and Head, Department of Prosthodontics, Post Graduate Institute of Dental Sciences, Pt. B.D Sharma University of Health Sciences, Rohtak, Haryana- 124001, India. Phone: 91-9416141376, E-mail: <email>ratheemanu@gmail.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub"><month>6</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub"><day>20</day>
<month>6</month>
<year>2014</year>
</pub-date>
<volume>8</volume>
<issue>6</issue>
<fpage>ZC26</fpage>
<lpage>ZC30</lpage>
<history><date date-type="received"><day>16</day>
<month>3</month>
<year>2014</year>
</date>
<date date-type="rev-request"><day>24</day>
<month>3</month>
<year>2014</year>
</date>
<date date-type="accepted"><day>04</day>
<month>5</month>
<year>2014</year>
</date>
</history>
<permissions><copyright-statement>© 2014 Journal of Clinical and Diagnostic Research</copyright-statement>
<copyright-year>2014</copyright-year>
</permissions>
<abstract><p><bold>Purpose:</bold>
To evaluate the effect of Platelet-Rich-Plasma (PRP) and different implant surface topography on implant stability and bone levels around immediately loaded dental implants.</p>
<p><bold>Materials and Methods:</bold>
Dental implants were placed in subjects divided into two groups and four subgroups on basis of implant treatment with PRP and implant surface topography used. A total of 30 implants were placed, 15 in each group. For PRP group, implants were placed after surface treatment with PRP. Temporization was done within two weeks and final prosthesis was given after three months. Implant stability was measured with Periotest at baseline, one month and three months. Bone height was measured on mesial & distal side on standardized IOPA x-rays.</p>
<p><bold>Results:</bold>
A statistically significant difference was noticed in implant stability with PRP at baseline. The effect of PRP on bone height changes was not statistically significant. A synergistic effect of PRP and square thread-form was observed on improved implant stability and bone levels; however, no such effect is seen with PRP and reverse buttress thread-form.</p>
<p><bold>Conclusion:</bold>
Within the limitation of this study, enhancement on implant stability and bone healing was observed with PRP treated implant surfaces, and with use of implant with square thread-form.</p>
</abstract>
<kwd-group><kwd>Immediate loading</kwd>
<kwd>Implant surface topography</kwd>
<kwd>Periotest</kwd>
<kwd>Platelet Rich Plasma</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000337 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000337 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV1 |flux= Pmc |étape= Corpus |type= RBID |clé= PMC:4129334 |texte= Effect of Platelet-Rich-Plasma (PRP) and Implant Surface Topography on Implant Stability and Bone }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i -Sk "pubmed:25121060" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV1
![]() | This area was generated with Dilib version V0.6.33. | ![]() |