Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy

Identifieur interne : 000151 ( Pmc/Corpus ); précédent : 000150; suivant : 000152

Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy

Auteurs : Indumathi Sivakumar ; Arunachalam Sivakumar

Source :

RBID : PMC:4147828

Abstract

The purpose of this case report is to demonstrate the use of orthodontic miniscrew implant in the intrusion of overerupted molar as a preprosthodontic therapy. A 37-year-old woman with an overerupted maxillary right first molar encroaching on the opposing mandibular edentulous space was successfully intruded using a single miniscrew implant and partial fixed orthodontic appliance. The prosthodontic clinician may adopt this conservative and cost-effective strategy in their routine practice and avoid clinical crown reduction.


Url:
DOI: 10.4103/0976-237X.137982
PubMed: 25191088
PubMed Central: 4147828

Links to Exploration step

PMC:4147828

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy</title>
<author>
<name sortKey="Sivakumar, Indumathi" sort="Sivakumar, Indumathi" uniqKey="Sivakumar I" first="Indumathi" last="Sivakumar">Indumathi Sivakumar</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Sivakumar, Arunachalam" sort="Sivakumar, Arunachalam" uniqKey="Sivakumar A" first="Arunachalam" last="Sivakumar">Arunachalam Sivakumar</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Orthodontics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India</italic>
</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">25191088</idno>
<idno type="pmc">4147828</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4147828</idno>
<idno type="RBID">PMC:4147828</idno>
<idno type="doi">10.4103/0976-237X.137982</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">000151</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000151</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy</title>
<author>
<name sortKey="Sivakumar, Indumathi" sort="Sivakumar, Indumathi" uniqKey="Sivakumar I" first="Indumathi" last="Sivakumar">Indumathi Sivakumar</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Sivakumar, Arunachalam" sort="Sivakumar, Arunachalam" uniqKey="Sivakumar A" first="Arunachalam" last="Sivakumar">Arunachalam Sivakumar</name>
<affiliation>
<nlm:aff id="aff2">
<italic>Department of Orthodontics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India</italic>
</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Contemporary Clinical Dentistry</title>
<idno type="ISSN">0976-237X</idno>
<idno type="eISSN">0976-2361</idno>
<imprint>
<date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>The purpose of this case report is to demonstrate the use of orthodontic miniscrew implant in the intrusion of overerupted molar as a preprosthodontic therapy. A 37-year-old woman with an overerupted maxillary right first molar encroaching on the opposing mandibular edentulous space was successfully intruded using a single miniscrew implant and partial fixed orthodontic appliance. The prosthodontic clinician may adopt this conservative and cost-effective strategy in their routine practice and avoid clinical crown reduction.</p>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Kanomi, R" uniqKey="Kanomi R">R Kanomi</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Costa, A" uniqKey="Costa A">A Costa</name>
</author>
<author>
<name sortKey="Raffainl, M" uniqKey="Raffainl M">M Raffainl</name>
</author>
<author>
<name sortKey="Melsen, B" uniqKey="Melsen B">B Melsen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bae, Sm" uniqKey="Bae S">SM Bae</name>
</author>
<author>
<name sortKey="Park, Hs" uniqKey="Park H">HS Park</name>
</author>
<author>
<name sortKey="Kyung, Hm" uniqKey="Kyung H">HM Kyung</name>
</author>
<author>
<name sortKey="Kwon, Ow" uniqKey="Kwon O">OW Kwon</name>
</author>
<author>
<name sortKey="Sung, Jh" uniqKey="Sung J">JH Sung</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kravitz, Nd" uniqKey="Kravitz N">ND Kravitz</name>
</author>
<author>
<name sortKey="Kusnoto, B" uniqKey="Kusnoto B">B Kusnoto</name>
</author>
<author>
<name sortKey="Tsay, Tp" uniqKey="Tsay T">TP Tsay</name>
</author>
<author>
<name sortKey="Hohlt, Wf" uniqKey="Hohlt W">WF Hohlt</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sohn, Ds" uniqKey="Sohn D">DS Sohn</name>
</author>
<author>
<name sortKey="Lee, Jk" uniqKey="Lee J">JK Lee</name>
</author>
<author>
<name sortKey="An, Km" uniqKey="An K">KM An</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Heymann, Gc" uniqKey="Heymann G">GC Heymann</name>
</author>
<author>
<name sortKey="Tulloch, Jf" uniqKey="Tulloch J">JF Tulloch</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Yao, Cc" uniqKey="Yao C">CC Yao</name>
</author>
<author>
<name sortKey="Lee, Jj" uniqKey="Lee J">JJ Lee</name>
</author>
<author>
<name sortKey="Chen, Hy" uniqKey="Chen H">HY Chen</name>
</author>
<author>
<name sortKey="Chang, Zc" uniqKey="Chang Z">ZC Chang</name>
</author>
<author>
<name sortKey="Chang, Hf" uniqKey="Chang H">HF Chang</name>
</author>
<author>
<name sortKey="Chen, Yj" uniqKey="Chen Y">YJ Chen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Jaffin, Ra" uniqKey="Jaffin R">RA Jaffin</name>
</author>
<author>
<name sortKey="Berman, Cl" uniqKey="Berman C">CL Berman</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Park, Hs" uniqKey="Park H">HS Park</name>
</author>
<author>
<name sortKey="Jang, Bk" uniqKey="Jang B">BK Jang</name>
</author>
<author>
<name sortKey="Kyung, Hm" uniqKey="Kyung H">HM Kyung</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Chun, Ys" uniqKey="Chun Y">YS Chun</name>
</author>
<author>
<name sortKey="Woo, Yj" uniqKey="Woo Y">YJ Woo</name>
</author>
<author>
<name sortKey="Row, J" uniqKey="Row J">J Row</name>
</author>
<author>
<name sortKey="Jung, Ej" uniqKey="Jung E">EJ Jung</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mizrahi, E" uniqKey="Mizrahi E">E Mizrahi</name>
</author>
<author>
<name sortKey="Mizrahi, B" uniqKey="Mizrahi B">B Mizrahi</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Poggio, Pm" uniqKey="Poggio P">PM Poggio</name>
</author>
<author>
<name sortKey="Incorvati, C" uniqKey="Incorvati C">C Incorvati</name>
</author>
<author>
<name sortKey="Velo, S" uniqKey="Velo S">S Velo</name>
</author>
<author>
<name sortKey="Carano, A" uniqKey="Carano A">A Carano</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Motoyoshi, M" uniqKey="Motoyoshi M">M Motoyoshi</name>
</author>
<author>
<name sortKey="Hirabayashi, M" uniqKey="Hirabayashi M">M Hirabayashi</name>
</author>
<author>
<name sortKey="Uemura, M" uniqKey="Uemura M">M Uemura</name>
</author>
<author>
<name sortKey="Shimizu, N" uniqKey="Shimizu N">N Shimizu</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="case-report">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Contemp Clin Dent</journal-id>
<journal-id journal-id-type="iso-abbrev">Contemp Clin Dent</journal-id>
<journal-id journal-id-type="publisher-id">CCD</journal-id>
<journal-title-group>
<journal-title>Contemporary Clinical Dentistry</journal-title>
</journal-title-group>
<issn pub-type="ppub">0976-237X</issn>
<issn pub-type="epub">0976-2361</issn>
<publisher>
<publisher-name>Medknow Publications & Media Pvt Ltd</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">25191088</article-id>
<article-id pub-id-type="pmc">4147828</article-id>
<article-id pub-id-type="publisher-id">CCD-5-422</article-id>
<article-id pub-id-type="doi">10.4103/0976-237X.137982</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Case Report</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Sivakumar</surname>
<given-names>Indumathi</given-names>
</name>
<xref ref-type="aff" rid="aff1"></xref>
<xref ref-type="corresp" rid="cor1"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Sivakumar</surname>
<given-names>Arunachalam</given-names>
</name>
<xref ref-type="aff" rid="aff2">1</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<italic>Department of Prosthodontics and Implantology, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India</italic>
</aff>
<aff id="aff2">
<label>1</label>
<italic>Department of Orthodontics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India</italic>
</aff>
<author-notes>
<corresp id="cor1">
<bold>Correspondence:</bold>
Dr. Indumathi Sivakumar, Department of Prosthodontics and Implantology, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India. E-mail:
<email xlink:href="cherub2008@gmail.com">cherub2008@gmail.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<season>Jul-Sep</season>
<year>2014</year>
</pub-date>
<volume>5</volume>
<issue>3</issue>
<fpage>422</fpage>
<lpage>424</lpage>
<permissions>
<copyright-statement>Copyright: © Contemporary Clinical Dentistry</copyright-statement>
<copyright-year>2014</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc-sa/3.0">
<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
<abstract>
<p>The purpose of this case report is to demonstrate the use of orthodontic miniscrew implant in the intrusion of overerupted molar as a preprosthodontic therapy. A 37-year-old woman with an overerupted maxillary right first molar encroaching on the opposing mandibular edentulous space was successfully intruded using a single miniscrew implant and partial fixed orthodontic appliance. The prosthodontic clinician may adopt this conservative and cost-effective strategy in their routine practice and avoid clinical crown reduction.</p>
</abstract>
<kwd-group>
<kwd>Adjunctive orthodontics</kwd>
<kwd>edentulous space discrepancy</kwd>
<kwd>miniscrew</kwd>
<kwd>miniscrew implant</kwd>
<kwd>molar intrusion</kwd>
<kwd>preprosthodontic therapy</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="sec1-1">
<title>Introduction</title>
<p>Prosthodontic rehabilitation of edentulous space is often complicated with overeruption of antagonistic tooth and often requires preprosthodontic intervention. In this context, orthodontic intrusion of the overerupted antagonistic tooth to facilitate prosthodontic rehabilitation is a desirable strategy. However, the task is formidable with routine orthodontic mechanics and control of anchorage is difficult. Recently, the introduction of miniscrew implants to the orthodontic armamentarium has widened the scope of intervention.[
<xref rid="ref1" ref-type="bibr">1</xref>
<xref rid="ref2" ref-type="bibr">2</xref>
<xref rid="ref3" ref-type="bibr">3</xref>
] Preprosthodontic intrusion of overerupted tooth with the aid of miniscrew implants is less invasive and simplistic.[
<xref rid="ref4" ref-type="bibr">4</xref>
<xref rid="ref5" ref-type="bibr">5</xref>
]</p>
<p>Miniscrew implants are made from titanium alloy or surgical grade stainless steel and employ a conical or tapered screw design with asymmetric or symmetric thread pitch. Currently, these screws are manufactured by a number of commercial companies and the screw diameters range from 1.2 to 2.5 mm and the lengths range from 6 to 11 mm. They can be placed directly through the gingival tissue into bone in between the roots of individual teeth with a hand driver or hand piece. Placement is minimally invasive and often completed using only topical anesthetic. Miniscrew implants are unique because unlike restorative endosseous implants they do not require osseointegration. Instead, these devices rely on mechanical retention to maintain rigidity, which also makes their removal relatively simple and noninvasive. Ideally, they should be placed in areas with adequate cortical bone and with the head of the screw in attached alveolar mucosa. They may be loaded immediately, but biomechanical factors must be taken into consideration owing to the increased chance of loosening associated with the lack of integration and torque or rotational forces that may occur under loading. Once they have served their purpose, they are removed.[
<xref rid="ref6" ref-type="bibr">6</xref>
]</p>
<p>This case report will focus on preprosthodontic intrusion of an overerupted molar using a single miniscrew implant and partial fixed orthodontic appliance.</p>
</sec>
<sec id="sec1-2">
<title>Case Report</title>
<p>A 37-year-old woman was seeking restoration of her right posterior occlusion. She presented with full complement of teeth except for mandibular right first molar that was extracted 3 years ago because of decay. As a result, the maxillary right first molar was overerupted and there was insufficient occlusal clearance [
<xref ref-type="fig" rid="F1">Figure 1</xref>
]. The patient was medically fit and healthy and presented with Class I occlusion and normodivergent facial pattern. Minor maxillary and mandibular crowding was evident. Her gingival health was fairly good. Judging by the marginal ridge discrepancy, the maxillary first molar had overerupted 3 mm occlusally, encroaching upon the antagonistic missing dental space. The objective of the treatment was to intrude the overerupted molar utilizing miniscrew implant anchorage and subsequently regain the appropriate dental space for prosthesis.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption>
<p>Right lateral view of occluded pretreatment cast and intra oral buccal view demonstrating overerupted maxillary right first molar and insufficient occlusal clearance for mandibular prosthesis</p>
</caption>
<graphic xlink:href="CCD-5-422-g001"></graphic>
</fig>
<p>The palatal interradicular space between maxillary first molar and second premolar was selected for miniscrew implant insertion. A 1.3 mm by 8 mm miniscrew implant (S.K. Surgicals, Pune, India) was threaded 7 mm from the alveolar crest apically at an angle of about 30°-40° to the dental axis using self-drilling mechanism (finger tightening). Prior to miniscrew placement, a slight purchase point was made by drilling a small pilot hole with a round bur using slow-speed contra-angle hand piece. This facilitated accurate directional control when threading the miniscrew implant into the bone. Sterile saline irrigation and strict antiseptic protocols were followed.</p>
<p>A 0.019 × 0.021 inch titanium-molybdenum alloy (TMA) wire was bent to a “V” shaped attachment with the apex of the “V” formed to a coil to engage elastic thread or coil spring. The free ends of the “V” were bent to conform to the occlusal surface of the molar tooth and bonded with composite. The whole attachment was juxtaposed to the palatal surface of the tooth [
<xref ref-type="fig" rid="F2">Figure 2a</xref>
]. An elastic thread (Tp Orthodontics Inc., La Porte, US) of sufficient length was tied between the head of the miniscrew implant and the coil in the “V” attachment to generate mild intrusive force of about 70 g. The calibration was done using dontrix gauge (ETM Corporation, Glendora, Calif). To avoid inadvertent palatal tipping and to favor a synchronous intrusion, a partial orthodontic appliance was fitted buccally to posterior dentition. The appliance set up consisted of a molar tube bonded off centered distally to the upper first molar, an edgewise bracket to first premolar and a 0.017 × 0.025 inch TMA helical spring. The spring was engaged between first molar tube and first premolar bracket and was activated to effect mild intrusive force of approximately 70 g [
<xref ref-type="fig" rid="F2">Figure 2b</xref>
]. The first premolar was anchored to the canine and second molar with rigid bonded wires to minimize the counter extrusion and rotation. The elastic thread was later replaced by a nickel titanium (NiTi) push coil spring (Dentaurum, Ispringen, Germany) [
<xref ref-type="fig" rid="F2">Figure 2c</xref>
].</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption>
<p>Orthodontic appliance set up. (a) Miniscrew implant threaded palatally between maxillary first molar and second premolar and elastic force delivery to the “V” attachment. (b) Activated titanium-molybdenum alloy helical spring. (c) A maxillary right occlusal view showing the full set up in place. First premolar anchored to the canine and second molar with rigid bonded wires to minimize the counter extrusion and rotation</p>
</caption>
<graphic xlink:href="CCD-5-422-g002"></graphic>
</fig>
<p>After 5 months of treatment, approximately 2.5 mm of intrusion was achieved. Subsequently, the occlusal clearance was sufficient to rebuild the posterior occlusion by a prosthesis placed in the area of the missing antagonistic tooth. Because the intraoral strap-up was minimized, the patient was able to follow oral hygiene instruction and, furthermore, was pleased with the simplified mechanical devices. Due to financial reasons, the patient had opted for fixed bridge prosthesis. Final occlusion [
<xref ref-type="fig" rid="F3">Figure 3</xref>
].</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption>
<p>After 5 months of treatment, restoration of right posterior occlusion</p>
</caption>
<graphic xlink:href="CCD-5-422-g003"></graphic>
</fig>
</sec>
<sec sec-type="discussion" id="sec1-3">
<title>Discussion</title>
<p>The case exemplified an effective mechanism using a single miniscrew implant to intrude overerupted tooth in patients who seek restorative care. With the advent of miniscrew implants supported intrusion, the need for possible crown reduction as preprosthodontic modality can be eliminated. Furthermore, the current strategy largely avoided the placement of full strap up fixed orthodontic appliances. The set up did drastically reduce the financial burden on the patient as well. The prosthodontic clinician may adopt this conservative and cost-effective strategy in their routine practice.</p>
<p>Molar intrusion is a challenging task, and it is more so in adult patients with restorative concerns. Use of miniscrew implant in preprosthodontic management has drawn great interest in recent years among researchers and clinicians. It is a predictable option with fewer side effects.[
<xref rid="ref4" ref-type="bibr">4</xref>
<xref rid="ref5" ref-type="bibr">5</xref>
] Recent studies have revealed that the average intrusion of maxillary molars is between 3 and 4 mm and a combination of single miniscrew implant and fixed appliance (partial) is a predictable and effective procedure to achieve maxillary molar intrusion.[
<xref rid="ref4" ref-type="bibr">4</xref>
<xref rid="ref7" ref-type="bibr">7</xref>
] No definite consensus exists as to where the miniscrew implant should be placed (buccal or palatal) if a single screw is used for maxillary first molar intrusion. The placement of screw in the palatal side mesial to first molar avoids the greater palatine foramen and D4 bone. Placement in D4 bone is not recommended owing to the high failure rate associated with it (35-50%).[
<xref rid="ref8" ref-type="bibr">8</xref>
] Another approach is that, it can be placed in the buccal dentoalveolus between the second premolar and first molar at the mucogingival junction and a raised transpalatal arch will effectively counter the buccal tipping of the molar and help in intrusion.[
<xref rid="ref4" ref-type="bibr">4</xref>
<xref rid="ref7" ref-type="bibr">7</xref>
] A miniscrew implant in the midpalatal area also can provide an effective intrusive force, but it should be combined with a rigid transpalatal bar to prevent the horizontal component of the force tipping the teeth. When tipping occurs the roots invariably move buccally.[
<xref rid="ref9" ref-type="bibr">9</xref>
] However, use of two screws on both buccal and palatal sides will effectively produce true intrusion. Nevertheless, on many occasions, the anatomic constraints dictate the placement site and the number of miniscrew implants. It is a prudent decision to minimize the orthodontic armamentarium for any adjunctive procedures favoring reduced financial burden and treatment acceptability by the adult patient. In the present case, the clinical situation demanded placement of a single miniscrew implant in the palatal side and minimal fixed appliance set up on the buccal side to produce an achievable optimum result in the shortest time period possible. The most critical factor for molar intrusion was the point of application of the intrusive force. To direct a force through the center of resistance of a molar, simultaneous buccal and palatal forces should be applied.[
<xref rid="ref9" ref-type="bibr">9</xref>
<xref rid="ref10" ref-type="bibr">10</xref>
] In the present case, the buccal and palatal forces were generated by the TMA helical spring and the miniscrew implant, respectively. The low load deflection rate of TMA spring and the mild activation of NiTi coil spring provided a balanced force system biomechanically.</p>
<p>Controlling or minimizing the side-effects associated with implant placement, implant stability and counter moments with force application is the main concern. The potential complications include contact with adjacent tooth roots, implant loosening, implant breakage, and damage to anatomic structures.[
<xref rid="ref11" ref-type="bibr">11</xref>
] Orthodontic miniscrew implant placement site selection can be effectively managed by astute clinical observation and palpation. Radiographs and surgical three-dimensional guides may be required, although not mandatory for every case. Strictly adhering to the safe zone protocols would suffice for a clean placement.[
<xref rid="ref12" ref-type="bibr">12</xref>
] Implant loosening can be attributed to soft-tissue inflammation and improper insertion torque. Achieving primary stability is essential and the implant needs only to be tightened to a torque value of 7-10 Ncm, which is achieved with mild finger tightening.[
<xref rid="ref13" ref-type="bibr">13</xref>
]</p>
</sec>
<sec sec-type="conclusion" id="sec1-4">
<title>Conclusion</title>
<p>Intrusion of overerupted molar using miniscrew implant as a preprosthodontic tooth movement is a predictable treatment strategy. Combination of a partial fixed appliance and miniscrew implant may provide a balanced force system for effective intrusion of molar. Miniscrew implant placement site selection and the design of the auxiliary appliance are the critical factors biomechanically.</p>
</sec>
</body>
<back>
<fn-group>
<fn fn-type="supported-by">
<p>
<bold>Source of Support:</bold>
Nil</p>
</fn>
<fn fn-type="conflict">
<p>
<bold>Conflict of Interest:</bold>
None declared.</p>
</fn>
</fn-group>
<ref-list>
<ref id="ref1">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kanomi</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Mini-implant for orthodontic anchorage</article-title>
<source>J Clin Orthod</source>
<year>1997</year>
<volume>31</volume>
<fpage>763</fpage>
<lpage>7</lpage>
<pub-id pub-id-type="pmid">9511584</pub-id>
</element-citation>
</ref>
<ref id="ref2">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Costa</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Raffainl</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Melsen</surname>
<given-names>B</given-names>
</name>
</person-group>
<article-title>Miniscrews as orthodontic anchorage: A preliminary report</article-title>
<source>Int J Adult Orthodon Orthognath Surg</source>
<year>1998</year>
<volume>13</volume>
<fpage>201</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">9835819</pub-id>
</element-citation>
</ref>
<ref id="ref3">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bae</surname>
<given-names>SM</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>HS</given-names>
</name>
<name>
<surname>Kyung</surname>
<given-names>HM</given-names>
</name>
<name>
<surname>Kwon</surname>
<given-names>OW</given-names>
</name>
<name>
<surname>Sung</surname>
<given-names>JH</given-names>
</name>
</person-group>
<article-title>Clinical application of micro-implant anchorage</article-title>
<source>J Clin Orthod</source>
<year>2002</year>
<volume>36</volume>
<fpage>298</fpage>
<lpage>302</lpage>
<pub-id pub-id-type="pmid">12056211</pub-id>
</element-citation>
</ref>
<ref id="ref4">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kravitz</surname>
<given-names>ND</given-names>
</name>
<name>
<surname>Kusnoto</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Tsay</surname>
<given-names>TP</given-names>
</name>
<name>
<surname>Hohlt</surname>
<given-names>WF</given-names>
</name>
</person-group>
<article-title>The use of temporary anchorage devices for molar intrusion</article-title>
<source>J Am Dent Assoc</source>
<year>2007</year>
<volume>138</volume>
<fpage>56</fpage>
<lpage>64</lpage>
<pub-id pub-id-type="pmid">17197402</pub-id>
</element-citation>
</ref>
<ref id="ref5">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sohn</surname>
<given-names>DS</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>JK</given-names>
</name>
<name>
<surname>An</surname>
<given-names>KM</given-names>
</name>
</person-group>
<article-title>Minor tooth movements using microimplant anchorage: Case reports</article-title>
<source>Implant Dent</source>
<year>2008</year>
<volume>17</volume>
<fpage>32</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">18332756</pub-id>
</element-citation>
</ref>
<ref id="ref6">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Heymann</surname>
<given-names>GC</given-names>
</name>
<name>
<surname>Tulloch</surname>
<given-names>JF</given-names>
</name>
</person-group>
<article-title>Implantable devices as orthodontic anchorage: A review of current treatment modalities</article-title>
<source>J Esthet Restor Dent</source>
<year>2006</year>
<volume>18</volume>
<fpage>68</fpage>
<lpage>79</lpage>
<pub-id pub-id-type="pmid">16519871</pub-id>
</element-citation>
</ref>
<ref id="ref7">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yao</surname>
<given-names>CC</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>JJ</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>HY</given-names>
</name>
<name>
<surname>Chang</surname>
<given-names>ZC</given-names>
</name>
<name>
<surname>Chang</surname>
<given-names>HF</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>YJ</given-names>
</name>
</person-group>
<article-title>Maxillary molar intrusion with fixed appliances and mini-implant anchorage studied in three dimensions</article-title>
<source>Angle Orthod</source>
<year>2005</year>
<volume>75</volume>
<fpage>754</fpage>
<lpage>60</lpage>
<pub-id pub-id-type="pmid">16279822</pub-id>
</element-citation>
</ref>
<ref id="ref8">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jaffin</surname>
<given-names>RA</given-names>
</name>
<name>
<surname>Berman</surname>
<given-names>CL</given-names>
</name>
</person-group>
<article-title>The excessive loss of Branemark fixtures in type IV bone: A 5-year analysis</article-title>
<source>J Periodontol</source>
<year>1991</year>
<volume>62</volume>
<fpage>2</fpage>
<lpage>4</lpage>
<pub-id pub-id-type="pmid">2002427</pub-id>
</element-citation>
</ref>
<ref id="ref9">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Park</surname>
<given-names>HS</given-names>
</name>
<name>
<surname>Jang</surname>
<given-names>BK</given-names>
</name>
<name>
<surname>Kyung</surname>
<given-names>HM</given-names>
</name>
</person-group>
<article-title>Maxillary molar intrusion with micro-implant anchorage (MIA)</article-title>
<source>Aust Orthod J</source>
<year>2005</year>
<volume>21</volume>
<fpage>129</fpage>
<lpage>35</lpage>
<pub-id pub-id-type="pmid">16429869</pub-id>
</element-citation>
</ref>
<ref id="ref10">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chun</surname>
<given-names>YS</given-names>
</name>
<name>
<surname>Woo</surname>
<given-names>YJ</given-names>
</name>
<name>
<surname>Row</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Jung</surname>
<given-names>EJ</given-names>
</name>
</person-group>
<article-title>Maxillary molar intrusion with the molar intrusion arch</article-title>
<source>J Clin Orthod</source>
<year>2000</year>
<volume>34</volume>
<fpage>90</fpage>
<lpage>3</lpage>
</element-citation>
</ref>
<ref id="ref11">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mizrahi</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Mizrahi</surname>
<given-names>B</given-names>
</name>
</person-group>
<article-title>Mini-screw implants (temporary anchorage devices): Orthodontic and pre-prosthetic applications</article-title>
<source>J Orthod</source>
<year>2007</year>
<volume>34</volume>
<fpage>80</fpage>
<lpage>94</lpage>
<pub-id pub-id-type="pmid">17545295</pub-id>
</element-citation>
</ref>
<ref id="ref12">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Poggio</surname>
<given-names>PM</given-names>
</name>
<name>
<surname>Incorvati</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Velo</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Carano</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>“Safe zones”: A guide for miniscrew positioning in the maxillary and mandibular arch</article-title>
<source>Angle Orthod</source>
<year>2006</year>
<volume>76</volume>
<fpage>191</fpage>
<lpage>7</lpage>
<pub-id pub-id-type="pmid">16539541</pub-id>
</element-citation>
</ref>
<ref id="ref13">
<label>13</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Motoyoshi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Hirabayashi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Uemura</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Shimizu</surname>
<given-names>N</given-names>
</name>
</person-group>
<article-title>Recommended placement torque when tightening an orthodontic mini-implant</article-title>
<source>Clin Oral Implants Res</source>
<year>2006</year>
<volume>17</volume>
<fpage>109</fpage>
<lpage>14</lpage>
<pub-id pub-id-type="pmid">16441792</pub-id>
</element-citation>
</ref>
</ref-list>
</back>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000151 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000151 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4147828
   |texte=   Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:25191088" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020