Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Comparative evaluation of the effects of implant position, impression material, and tray type on implant impression accuracy.

Identifieur interne : 000D22 ( Ncbi/Merge ); précédent : 000D21; suivant : 000D23

Comparative evaluation of the effects of implant position, impression material, and tray type on implant impression accuracy.

Auteurs : Bilge Gökçen-Rohlig [Turquie] ; De Er Ongül ; Erkan Sancakli ; Bülent Sermet

Source :

RBID : pubmed:24844388

Descripteurs français

English descriptors

Abstract

To evaluate the effect of implant position, impression, and tray material on the accuracy of implant impressions of edentulous arches with multiple implants.

DOI: 10.1097/ID.0000000000000059
PubMed: 24844388

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:24844388

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Comparative evaluation of the effects of implant position, impression material, and tray type on implant impression accuracy.</title>
<author>
<name sortKey="Gokcen Rohlig, Bilge" sort="Gokcen Rohlig, Bilge" uniqKey="Gokcen Rohlig B" first="Bilge" last="Gökçen-Rohlig">Bilge Gökçen-Rohlig</name>
<affiliation wicri:level="1">
<nlm:affiliation>*Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. †Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. ‡Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>*Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. †Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. ‡Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ongul, De Er" sort="Ongul, De Er" uniqKey="Ongul D" first="De Er" last="Ongül">De Er Ongül</name>
</author>
<author>
<name sortKey="Sancakli, Erkan" sort="Sancakli, Erkan" uniqKey="Sancakli E" first="Erkan" last="Sancakli">Erkan Sancakli</name>
</author>
<author>
<name sortKey="Sermet, Bulent" sort="Sermet, Bulent" uniqKey="Sermet B" first="Bülent" last="Sermet">Bülent Sermet</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:24844388</idno>
<idno type="pmid">24844388</idno>
<idno type="doi">10.1097/ID.0000000000000059</idno>
<idno type="wicri:Area/PubMed/Corpus">000795</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000795</idno>
<idno type="wicri:Area/PubMed/Curation">000795</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000795</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000795</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000795</idno>
<idno type="wicri:Area/Ncbi/Merge">000D22</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Comparative evaluation of the effects of implant position, impression material, and tray type on implant impression accuracy.</title>
<author>
<name sortKey="Gokcen Rohlig, Bilge" sort="Gokcen Rohlig, Bilge" uniqKey="Gokcen Rohlig B" first="Bilge" last="Gökçen-Rohlig">Bilge Gökçen-Rohlig</name>
<affiliation wicri:level="1">
<nlm:affiliation>*Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. †Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. ‡Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>*Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. †Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. ‡Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ongul, De Er" sort="Ongul, De Er" uniqKey="Ongul D" first="De Er" last="Ongül">De Er Ongül</name>
</author>
<author>
<name sortKey="Sancakli, Erkan" sort="Sancakli, Erkan" uniqKey="Sancakli E" first="Erkan" last="Sancakli">Erkan Sancakli</name>
</author>
<author>
<name sortKey="Sermet, Bulent" sort="Sermet, Bulent" uniqKey="Sermet B" first="Bülent" last="Sermet">Bülent Sermet</name>
</author>
</analytic>
<series>
<title level="j">Implant dentistry</title>
<idno type="eISSN">1538-2982</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Dental Implants (standards)</term>
<term>Dental Impression Materials (therapeutic use)</term>
<term>Dental Impression Technique (instrumentation)</term>
<term>Dental Impression Technique (standards)</term>
<term>Dental Instruments</term>
<term>Humans</term>
<term>Polyvinyls (therapeutic use)</term>
<term>Siloxanes (therapeutic use)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Humains</term>
<term>Implants dentaires (normes)</term>
<term>Instruments dentaires</term>
<term>Matériaux empreinte dentaire (usage thérapeutique)</term>
<term>Polyvinyles (usage thérapeutique)</term>
<term>Siloxanes (usage thérapeutique)</term>
<term>Technique de prise d'empreinte (instrumentation)</term>
<term>Technique de prise d'empreinte (normes)</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="standards" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="therapeutic use" xml:lang="en">
<term>Dental Impression Materials</term>
<term>Polyvinyls</term>
<term>Siloxanes</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Dental Impression Technique</term>
</keywords>
<keywords scheme="MESH" qualifier="normes" xml:lang="fr">
<term>Implants dentaires</term>
<term>Technique de prise d'empreinte</term>
</keywords>
<keywords scheme="MESH" qualifier="standards" xml:lang="en">
<term>Dental Impression Technique</term>
</keywords>
<keywords scheme="MESH" qualifier="usage thérapeutique" xml:lang="fr">
<term>Matériaux empreinte dentaire</term>
<term>Polyvinyles</term>
<term>Siloxanes</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Instruments</term>
<term>Humans</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Humains</term>
<term>Instruments dentaires</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To evaluate the effect of implant position, impression, and tray material on the accuracy of implant impressions of edentulous arches with multiple implants.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">24844388</PMID>
<DateCompleted>
<Year>2015</Year>
<Month>09</Month>
<Day>16</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>05</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1538-2982</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>23</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2014</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Implant dentistry</Title>
<ISOAbbreviation>Implant Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Comparative evaluation of the effects of implant position, impression material, and tray type on implant impression accuracy.</ArticleTitle>
<Pagination>
<MedlinePgn>283-8</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1097/ID.0000000000000059</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To evaluate the effect of implant position, impression, and tray material on the accuracy of implant impressions of edentulous arches with multiple implants.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Four experimental groups were produced; medium-viscosity polyvinyl siloxane (PVS) was used in 3 groups and polyether was used in 1 group. In PVS groups, different tray types were used; metal stock trays, custom acrylic tray, and full-arch perforated plastic trays. In polyether group, custom acrylic trays were used. The discrepancies in 3 dimensions were measured.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The casts obtained exhibited small deviations (7.50-9.71 µm) from the master cast. There was no statistically significant difference between the polyether and PVS groups. Similarly, different tray materials did not produce any statistically significant discrepancies within the PVS groups. There was no significant difference among the groups when the accuracy of anterior implants were compared, but within-the-group comparisons showed that except group 1 (GR1), the posterior implants demonstrated more accuracy than anterior ones.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Polyether and PVS can safely be used for the impressions of the edentulous arches with multiple implants and different tray types produce similar accuracy results.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Gökçen-Rohlig</LastName>
<ForeName>Bilge</ForeName>
<Initials>B</Initials>
<AffiliationInfo>
<Affiliation>*Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. †Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey. ‡Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Capa, Istanbul, Turkey.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Ongül</LastName>
<ForeName>Değer</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Sancakli</LastName>
<ForeName>Erkan</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Sermet</LastName>
<ForeName>Bülent</ForeName>
<Initials>B</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Implant Dent</MedlineTA>
<NlmUniqueID>9206481</NlmUniqueID>
<ISSNLinking>1056-6163</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003760">Dental Impression Materials</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011145">Polyvinyls</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012833">Siloxanes</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="C034183">vinyl polysiloxane</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
<QualifierName UI="Q000592" MajorTopicYN="N">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003760" MajorTopicYN="N">Dental Impression Materials</DescriptorName>
<QualifierName UI="Q000627" MajorTopicYN="N">therapeutic use</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003761" MajorTopicYN="Y">Dental Impression Technique</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000592" MajorTopicYN="N">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003762" MajorTopicYN="N">Dental Instruments</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011145" MajorTopicYN="N">Polyvinyls</DescriptorName>
<QualifierName UI="Q000627" MajorTopicYN="N">therapeutic use</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012833" MajorTopicYN="N">Siloxanes</DescriptorName>
<QualifierName UI="Q000627" MajorTopicYN="N">therapeutic use</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>5</Month>
<Day>22</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>5</Month>
<Day>23</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>9</Month>
<Day>17</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">24844388</ArticleId>
<ArticleId IdType="doi">10.1097/ID.0000000000000059</ArticleId>
<ArticleId IdType="pii">00008505-201406000-00011</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Turquie</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Ongul, De Er" sort="Ongul, De Er" uniqKey="Ongul D" first="De Er" last="Ongül">De Er Ongül</name>
<name sortKey="Sancakli, Erkan" sort="Sancakli, Erkan" uniqKey="Sancakli E" first="Erkan" last="Sancakli">Erkan Sancakli</name>
<name sortKey="Sermet, Bulent" sort="Sermet, Bulent" uniqKey="Sermet B" first="Bülent" last="Sermet">Bülent Sermet</name>
</noCountry>
<country name="Turquie">
<noRegion>
<name sortKey="Gokcen Rohlig, Bilge" sort="Gokcen Rohlig, Bilge" uniqKey="Gokcen Rohlig B" first="Bilge" last="Gökçen-Rohlig">Bilge Gökçen-Rohlig</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000D22 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000D22 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:24844388
   |texte=   Comparative evaluation of the effects of implant position, impression material, and tray type on implant impression accuracy.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:24844388" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020