Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy.
Identifieur interne : 000127 ( Ncbi/Merge ); précédent : 000126; suivant : 000128Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy.
Auteurs : Zerrin Fidan Akalin [Turquie] ; Yasemin Kulak Ozkan ; Ahmet EkerimSource :
- The International journal of oral & maxillofacial implants [ 1942-4434 ]
Descripteurs français
- KwdFr :
- MESH :
English descriptors
- KwdEn :
- MESH :
Abstract
The effects of implant angulation, impression material, and variation in width of the arch curvature on transfer models were evaluated.
PubMed: 23377060
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 000381
- to stream PubMed, to step Curation: 000381
- to stream PubMed, to step Checkpoint: 000381
Links to Exploration step
pubmed:23377060Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy.</title>
<author><name sortKey="Akalin, Zerrin Fidan" sort="Akalin, Zerrin Fidan" uniqKey="Akalin Z" first="Zerrin Fidan" last="Akalin">Zerrin Fidan Akalin</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Prosthetic Dentistry, School of Dentistry, University of Marmara, Istanbul, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Prosthetic Dentistry, School of Dentistry, University of Marmara, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Ozkan, Yasemin Kulak" sort="Ozkan, Yasemin Kulak" uniqKey="Ozkan Y" first="Yasemin Kulak" last="Ozkan">Yasemin Kulak Ozkan</name>
</author>
<author><name sortKey="Ekerim, Ahmet" sort="Ekerim, Ahmet" uniqKey="Ekerim A" first="Ahmet" last="Ekerim">Ahmet Ekerim</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>2013 Jan-Feb</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:23377060</idno>
<idno type="pmid">23377060</idno>
<idno type="wicri:Area/PubMed/Corpus">000381</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000381</idno>
<idno type="wicri:Area/PubMed/Curation">000381</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000381</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000381</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000381</idno>
<idno type="wicri:Area/Ncbi/Merge">000127</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy.</title>
<author><name sortKey="Akalin, Zerrin Fidan" sort="Akalin, Zerrin Fidan" uniqKey="Akalin Z" first="Zerrin Fidan" last="Akalin">Zerrin Fidan Akalin</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Prosthetic Dentistry, School of Dentistry, University of Marmara, Istanbul, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Prosthetic Dentistry, School of Dentistry, University of Marmara, Istanbul</wicri:regionArea>
<wicri:noRegion>Istanbul</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Ozkan, Yasemin Kulak" sort="Ozkan, Yasemin Kulak" uniqKey="Ozkan Y" first="Yasemin Kulak" last="Ozkan">Yasemin Kulak Ozkan</name>
</author>
<author><name sortKey="Ekerim, Ahmet" sort="Ekerim, Ahmet" uniqKey="Ekerim A" first="Ahmet" last="Ekerim">Ahmet Ekerim</name>
</author>
</analytic>
<series><title level="j">The International journal of oral & maxillofacial implants</title>
<idno type="eISSN">1942-4434</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Dental Abutments</term>
<term>Dental Implants</term>
<term>Dental Impression Materials</term>
<term>Dental Impression Technique</term>
<term>Dental Models</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Polyvinyls</term>
<term>Siloxanes</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Conception de prothèse dentaire</term>
<term>Implants dentaires</term>
<term>Matériaux empreinte dentaire</term>
<term>Modèles dentaires</term>
<term>Piliers dentaires</term>
<term>Polyvinyles</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Siloxanes</term>
<term>Technique de prise d'empreinte</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Dental Implants</term>
<term>Dental Impression Materials</term>
<term>Polyvinyls</term>
<term>Siloxanes</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Dental Abutments</term>
<term>Dental Impression Technique</term>
<term>Dental Models</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Conception de prothèse dentaire</term>
<term>Implants dentaires</term>
<term>Matériaux empreinte dentaire</term>
<term>Modèles dentaires</term>
<term>Piliers dentaires</term>
<term>Polyvinyles</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Siloxanes</term>
<term>Technique de prise d'empreinte</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The effects of implant angulation, impression material, and variation in width of the arch curvature on transfer models were evaluated.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">23377060</PMID>
<DateCompleted><Year>2014</Year>
<Month>02</Month>
<Day>06</Day>
</DateCompleted>
<DateRevised><Year>2013</Year>
<Month>02</Month>
<Day>04</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Electronic">1942-4434</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>28</Volume>
<Issue>1</Issue>
<PubDate><MedlineDate>2013 Jan-Feb</MedlineDate>
</PubDate>
</JournalIssue>
<Title>The International journal of oral & maxillofacial implants</Title>
<ISOAbbreviation>Int J Oral Maxillofac Implants</ISOAbbreviation>
</Journal>
<ArticleTitle>Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy.</ArticleTitle>
<Pagination><MedlinePgn>149-57</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.11607/jomi.2070</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The effects of implant angulation, impression material, and variation in width of the arch curvature on transfer models were evaluated.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Three edentulous maxillary epoxy resin models were fabricated, and six internal-connection implant analogs were placed in different locations and different angulations in each model. In the first model, implants were positioned in the canine, first premolar, and first molar regions, and all analogs were positioned parallel to each other and perpendicular to the horizontal crestal plane (parallel model). In the second model, analogs were positioned in same regions (canine, first premolar, and first molar), but three of them were positioned with 10-degree buccal angulations (versus the horizontal crestal plane) (angular model). In the third model, analogs were inserted in the lateral incisor, canine, and second molar regions and parallel to each other (wide-arch model). Eighteen impressions of each model were made with each of the three materials--condensation silicone, polyvinyl siloxane, and polyether--and impressions were poured and kept at room temperature for 24 hours. They were then observed under a toolmaker's microscope, with epoxy resin models of each group used as references. Distance deformations between implants in each model in the x- and y-axes were recorded separately. Implant angulation deformations were recorded in the x-z plane. Statistical evaluations were performed with analysis of variance and the least significant difference post hoc test.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Angular model measurements showed the greatest deformation values (P < .05). All impression materials showed deformation, and the polyether impression models showed statistically significantly less deformation in angular measurements (P < .05).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The models with implants placed parallel to each other exhibited greater accuracy than a model with implants placed at angles to each other.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Akalin</LastName>
<ForeName>Zerrin Fidan</ForeName>
<Initials>ZF</Initials>
<AffiliationInfo><Affiliation>Department of Prosthetic Dentistry, School of Dentistry, University of Marmara, Istanbul, Turkey.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Ozkan</LastName>
<ForeName>Yasemin Kulak</ForeName>
<Initials>YK</Initials>
</Author>
<Author ValidYN="Y"><LastName>Ekerim</LastName>
<ForeName>Ahmet</ForeName>
<Initials>A</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Int J Oral Maxillofac Implants</MedlineTA>
<NlmUniqueID>8611905</NlmUniqueID>
<ISSNLinking>0882-2786</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003760">Dental Impression Materials</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011145">Polyvinyls</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012833">Siloxanes</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="C034183">vinyl polysiloxane</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000044" MajorTopicYN="N">Dental Abutments</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015921" MajorTopicYN="N">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003760" MajorTopicYN="Y">Dental Impression Materials</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003761" MajorTopicYN="Y">Dental Impression Technique</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017267" MajorTopicYN="Y">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D019094" MajorTopicYN="N">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011145" MajorTopicYN="N">Polyvinyls</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D012833" MajorTopicYN="N">Siloxanes</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2013</Year>
<Month>2</Month>
<Day>5</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2013</Year>
<Month>2</Month>
<Day>5</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2014</Year>
<Month>2</Month>
<Day>7</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">23377060</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations><list><country><li>Turquie</li>
</country>
</list>
<tree><noCountry><name sortKey="Ekerim, Ahmet" sort="Ekerim, Ahmet" uniqKey="Ekerim A" first="Ahmet" last="Ekerim">Ahmet Ekerim</name>
<name sortKey="Ozkan, Yasemin Kulak" sort="Ozkan, Yasemin Kulak" uniqKey="Ozkan Y" first="Yasemin Kulak" last="Ozkan">Yasemin Kulak Ozkan</name>
</noCountry>
<country name="Turquie"><noRegion><name sortKey="Akalin, Zerrin Fidan" sort="Akalin, Zerrin Fidan" uniqKey="Akalin Z" first="Zerrin Fidan" last="Akalin">Zerrin Fidan Akalin</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000127 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000127 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV1 |flux= Ncbi |étape= Merge |type= RBID |clé= pubmed:23377060 |texte= Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i -Sk "pubmed:23377060" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV1
This area was generated with Dilib version V0.6.33. |