Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants

Identifieur interne : 000598 ( Main/Merge ); précédent : 000597; suivant : 000599

Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants

Auteurs : Sudhindra Mahoorkar ; Anoop Jain ; Cauvery K ; Pawan Kumar ; Raghavendra Havale

Source :

RBID : PMC:4064874

Abstract

An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques.


Url:
DOI: 10.7860/JCDR/2014/7623.4280
PubMed: 24959520
PubMed Central: 4064874

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:4064874

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants</title>
<author>
<name sortKey="Mahoorkar, Sudhindra" sort="Mahoorkar, Sudhindra" uniqKey="Mahoorkar S" first="Sudhindra" last="Mahoorkar">Sudhindra Mahoorkar</name>
<affiliation>
<nlm:aff id="aff1"> Professor, Department of Prosthodontics,
<institution>HKE’S SN Institute of Dental Sciences & Research</institution>
,
<addr-line>Karnataka-585105, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Jain, Anoop" sort="Jain, Anoop" uniqKey="Jain A" first="Anoop" last="Jain">Anoop Jain</name>
<affiliation>
<nlm:aff id="aff2"> Director, Senior Prosthodontist & Implantologist, Department of Prosthodontics,
<institution>Dental XPERTS</institution>
,
<addr-line>A3/221, First F loor, Sector 17, Rohini, Delhi-110089, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="K, Cauvery" sort="K, Cauvery" uniqKey="K C" first="Cauvery" last="K">Cauvery K</name>
<affiliation>
<nlm:aff id="aff3"> Senior Lecturer, Department of Periodontics,
<institution>PDU Dental College</institution>
,
<addr-line>Kegoan, Solapur, Maharastra- 413225, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Kumar, Pawan" sort="Kumar, Pawan" uniqKey="Kumar P" first="Pawan" last="Kumar">Pawan Kumar</name>
<affiliation>
<nlm:aff id="aff4"> Reader, Department of Prosthodontics,
<institution>Al-Badar Rural Dental College & Hospital</institution>
,
<addr-line>MSK Mill Road, Gulbarga, Karnataka- 585102, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Havale, Raghavendra" sort="Havale, Raghavendra" uniqKey="Havale R" first="Raghavendra" last="Havale">Raghavendra Havale</name>
<affiliation>
<nlm:aff id="aff5"> Reader, Department of Pedodontics,
<institution>AME’S Dental College</institution>
,
<addr-line>Raichur, Karnataka-584103, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">24959520</idno>
<idno type="pmc">4064874</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4064874</idno>
<idno type="RBID">PMC:4064874</idno>
<idno type="doi">10.7860/JCDR/2014/7623.4280</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">000335</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000335</idno>
<idno type="wicri:Area/Pmc/Curation">000335</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000335</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000223</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">000223</idno>
<idno type="wicri:Area/Ncbi/Merge">000E68</idno>
<idno type="wicri:Area/Ncbi/Curation">000E68</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000E68</idno>
<idno type="wicri:doubleKey">2249-782X:2014:Mahoorkar S:modification:of:fixture</idno>
<idno type="wicri:Area/Main/Merge">000598</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants</title>
<author>
<name sortKey="Mahoorkar, Sudhindra" sort="Mahoorkar, Sudhindra" uniqKey="Mahoorkar S" first="Sudhindra" last="Mahoorkar">Sudhindra Mahoorkar</name>
<affiliation>
<nlm:aff id="aff1"> Professor, Department of Prosthodontics,
<institution>HKE’S SN Institute of Dental Sciences & Research</institution>
,
<addr-line>Karnataka-585105, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Jain, Anoop" sort="Jain, Anoop" uniqKey="Jain A" first="Anoop" last="Jain">Anoop Jain</name>
<affiliation>
<nlm:aff id="aff2"> Director, Senior Prosthodontist & Implantologist, Department of Prosthodontics,
<institution>Dental XPERTS</institution>
,
<addr-line>A3/221, First F loor, Sector 17, Rohini, Delhi-110089, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="K, Cauvery" sort="K, Cauvery" uniqKey="K C" first="Cauvery" last="K">Cauvery K</name>
<affiliation>
<nlm:aff id="aff3"> Senior Lecturer, Department of Periodontics,
<institution>PDU Dental College</institution>
,
<addr-line>Kegoan, Solapur, Maharastra- 413225, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Kumar, Pawan" sort="Kumar, Pawan" uniqKey="Kumar P" first="Pawan" last="Kumar">Pawan Kumar</name>
<affiliation>
<nlm:aff id="aff4"> Reader, Department of Prosthodontics,
<institution>Al-Badar Rural Dental College & Hospital</institution>
,
<addr-line>MSK Mill Road, Gulbarga, Karnataka- 585102, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Havale, Raghavendra" sort="Havale, Raghavendra" uniqKey="Havale R" first="Raghavendra" last="Havale">Raghavendra Havale</name>
<affiliation>
<nlm:aff id="aff5"> Reader, Department of Pedodontics,
<institution>AME’S Dental College</institution>
,
<addr-line>Raichur, Karnataka-584103, India</addr-line>
.</nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of Clinical and Diagnostic Research : JCDR</title>
<idno type="ISSN">2249-782X</idno>
<idno type="eISSN">0973-709X</idno>
<imprint>
<date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques.</p>
</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000598 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 000598 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     PMC:4064874
   |texte=   Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i   -Sk "pubmed:24959520" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020