Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide?

Identifieur interne : 000732 ( Main/Exploration ); précédent : 000731; suivant : 000733

How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide?

Auteurs : M. Cassetta [Italie] ; A. Di Mambro [Italie] ; M. Giansanti [Italie] ; L V Stefanelli [Italie] ; E. Barbato [Italie]

Source :

RBID : pubmed:23916310

Descripteurs français

English descriptors

Abstract

Computer-aided implantology using a single fixed stereolithographic surgical guide involves a sequence of diagnostic and therapeutic events, and errors can creep in at different stages. Taken together, these can be termed the 'total error'. A positioning of the surgical guide on the support surface different to that of the diagnostic template may generate an error that reoccurs with all the implants inserted, and this error can be termed the 'guide positioning error'. The aim of the present study was to measure the deviation between the planned and inserted implants due to this guide positioning error, to evaluate if this error was statistically significant, and concurrently, to assess the influence of the type of arch (upper vs lower jaw) and mucosal thickness on the guide positioning error. Twenty-four subjects were treated and 172 implants inserted. Preoperative and postoperative computed tomography images were compared using Mimics software to determine the total error and guide positioning error. Quantitative data were described; the t-test and Pearson correlation coefficient were used. The guide positioning error was found to affect the accuracy, but was statistically significant only for global coronal deviation (P = 0.038). Arch of support and mucosa thickness did not affect the guide positioning error.

DOI: 10.1016/j.ijom.2013.06.012
PubMed: 23916310


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide?</title>
<author>
<name sortKey="Cassetta, M" sort="Cassetta, M" uniqKey="Cassetta M" first="M" last="Cassetta">M. Cassetta</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy. Electronic address: michele.cassetta@uniroma1.it.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Di Mambro, A" sort="Di Mambro, A" uniqKey="Di Mambro A" first="A" last="Di Mambro">A. Di Mambro</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Giansanti, M" sort="Giansanti, M" uniqKey="Giansanti M" first="M" last="Giansanti">M. Giansanti</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Stefanelli, L V" sort="Stefanelli, L V" uniqKey="Stefanelli L" first="L V" last="Stefanelli">L V Stefanelli</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Barbato, E" sort="Barbato, E" uniqKey="Barbato E" first="E" last="Barbato">E. Barbato</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:23916310</idno>
<idno type="pmid">23916310</idno>
<idno type="doi">10.1016/j.ijom.2013.06.012</idno>
<idno type="wicri:Area/PubMed/Corpus">000569</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000569</idno>
<idno type="wicri:Area/PubMed/Curation">000569</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000569</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000569</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000569</idno>
<idno type="wicri:Area/Ncbi/Merge">000458</idno>
<idno type="wicri:Area/Ncbi/Curation">000458</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000458</idno>
<idno type="wicri:Area/Main/Merge">000734</idno>
<idno type="wicri:Area/Main/Curation">000732</idno>
<idno type="wicri:Area/Main/Exploration">000732</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide?</title>
<author>
<name sortKey="Cassetta, M" sort="Cassetta, M" uniqKey="Cassetta M" first="M" last="Cassetta">M. Cassetta</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy. Electronic address: michele.cassetta@uniroma1.it.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Di Mambro, A" sort="Di Mambro, A" uniqKey="Di Mambro A" first="A" last="Di Mambro">A. Di Mambro</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Giansanti, M" sort="Giansanti, M" uniqKey="Giansanti M" first="M" last="Giansanti">M. Giansanti</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Stefanelli, L V" sort="Stefanelli, L V" uniqKey="Stefanelli L" first="L V" last="Stefanelli">L V Stefanelli</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Barbato, E" sort="Barbato, E" uniqKey="Barbato E" first="E" last="Barbato">E. Barbato</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Oral and Maxillofacial Sciences, School of Dentistry, "Sapienza" University of Rome, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
</analytic>
<series>
<title level="j">International journal of oral and maxillofacial surgery</title>
<idno type="eISSN">1399-0020</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous (instrumentation)</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Implants</term>
<term>Dental Instruments</term>
<term>Dental Prosthesis Design</term>
<term>Dimensional Measurement Accuracy</term>
<term>Female</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (surgery)</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Mouth Mucosa (surgery)</term>
<term>Retrospective Studies</term>
<term>Software</term>
<term>Surgery, Computer-Assisted (instrumentation)</term>
<term>Surgery, Computer-Assisted (methods)</term>
<term>Tomography, X-Ray Computed</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Adulte d'âge moyen</term>
<term>Chirurgie assistée par ordinateur ()</term>
<term>Chirurgie assistée par ordinateur (instrumentation)</term>
<term>Conception assistée par ordinateur</term>
<term>Conception de prothèse dentaire</term>
<term>Femelle</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Instruments dentaires</term>
<term>Logiciel</term>
<term>Muqueuse de la bouche ()</term>
<term>Mâchoire édentée ()</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Mâle</term>
<term>Pose d'implant dentaire endo-osseux ()</term>
<term>Pose d'implant dentaire endo-osseux (instrumentation)</term>
<term>Précision de la mesure dimensionnelle</term>
<term>Tomodensitométrie</term>
<term>Études rétrospectives</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Mouth Mucosa</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Instruments</term>
<term>Dental Prosthesis Design</term>
<term>Dimensional Measurement Accuracy</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Retrospective Studies</term>
<term>Software</term>
<term>Tomography, X-Ray Computed</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Adulte d'âge moyen</term>
<term>Chirurgie assistée par ordinateur</term>
<term>Conception assistée par ordinateur</term>
<term>Conception de prothèse dentaire</term>
<term>Femelle</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Instruments dentaires</term>
<term>Logiciel</term>
<term>Muqueuse de la bouche</term>
<term>Mâchoire édentée</term>
<term>Mâle</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Précision de la mesure dimensionnelle</term>
<term>Tomodensitométrie</term>
<term>Études rétrospectives</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Computer-aided implantology using a single fixed stereolithographic surgical guide involves a sequence of diagnostic and therapeutic events, and errors can creep in at different stages. Taken together, these can be termed the 'total error'. A positioning of the surgical guide on the support surface different to that of the diagnostic template may generate an error that reoccurs with all the implants inserted, and this error can be termed the 'guide positioning error'. The aim of the present study was to measure the deviation between the planned and inserted implants due to this guide positioning error, to evaluate if this error was statistically significant, and concurrently, to assess the influence of the type of arch (upper vs lower jaw) and mucosal thickness on the guide positioning error. Twenty-four subjects were treated and 172 implants inserted. Preoperative and postoperative computed tomography images were compared using Mimics software to determine the total error and guide positioning error. Quantitative data were described; the t-test and Pearson correlation coefficient were used. The guide positioning error was found to affect the accuracy, but was statistically significant only for global coronal deviation (P = 0.038). Arch of support and mucosa thickness did not affect the guide positioning error.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Italie</li>
</country>
<region>
<li>Latium</li>
</region>
<settlement>
<li>Rome</li>
</settlement>
</list>
<tree>
<country name="Italie">
<region name="Latium">
<name sortKey="Cassetta, M" sort="Cassetta, M" uniqKey="Cassetta M" first="M" last="Cassetta">M. Cassetta</name>
</region>
<name sortKey="Barbato, E" sort="Barbato, E" uniqKey="Barbato E" first="E" last="Barbato">E. Barbato</name>
<name sortKey="Di Mambro, A" sort="Di Mambro, A" uniqKey="Di Mambro A" first="A" last="Di Mambro">A. Di Mambro</name>
<name sortKey="Giansanti, M" sort="Giansanti, M" uniqKey="Giansanti M" first="M" last="Giansanti">M. Giansanti</name>
<name sortKey="Stefanelli, L V" sort="Stefanelli, L V" uniqKey="Stefanelli L" first="L V" last="Stefanelli">L V Stefanelli</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000732 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000732 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:23916310
   |texte=   How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide?
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:23916310" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020