Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

To Study the Flow Property of Seven Commercially Available Zinc Oxide Eugenol Impression Material at Various Time Intervals After Mixing

Identifieur interne : 000287 ( Main/Exploration ); précédent : 000286; suivant : 000288

To Study the Flow Property of Seven Commercially Available Zinc Oxide Eugenol Impression Material at Various Time Intervals After Mixing

Auteurs : Vishal Katna ; S. Suresh ; Sharma Vivek ; Khandelwal Meenakshi ; Gaur Ankita

Source :

RBID : PMC:4257930

Abstract

Aims and objective of the study was to evaluate the flow property of seven commercially available zinc oxide eugenol impression materials at various time intervals, after mixing 49 samples (seven groups) were fabricated for flow property of the material. The sample were fabricated as equal length of base and accelerator paste of the test materials was taken on the glass slab and mixed with a rigid stainless steel spatula as per manufacturers recommendation till the homogenous mix was obtained. The mix material was loaded in glass syringe and 0.5 ml material was injected on a cellophane sheet placed on marked glass plate. A cellophane sheet and glass plate 70 and 500 g weight was carefully placed on freshly dispensed zinc oxide eugenol impression paste sequentially. The diameter of the mix was noted after 30 s and 1 min of load application and also after the final set of material. The diameter gives the flow of material. The samples were stored at the room temperature. The data of the flow property was analyzed with analysis of variance, Post hoc test and t test. The flow of the zinc oxide eugenol impression paste after 30 s, 1 min and final set of load application for Group A to Group G was noted. Maximum flow was seen for Group G zinc oxide eugenol impression material followed by Group F, D, E, B, C and A in descending order respectively after 30 s, where as the flow property changed after 1 min in the sequence of maximum for Group G followed by Group E, D, B, A, C, and F. Lastly after final set of the impression material the flow maximum for Group G followed by Group E, D, C, F, A and B in descending order. Based on statistical analysis of the results and within in the limitations of this in-vitro study, the following conclusions were drawn that; the flow of zinc oxide eugenol impression material after 30 s, 1 min and that after the final set was maximum for P.S.P. (Group G) and the flow for PYREX (Group A) was minimum.


Url:
DOI: 10.1007/s13191-013-0338-7
PubMed: 25489163
PubMed Central: 4257930


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">To Study the Flow Property of Seven Commercially Available Zinc Oxide Eugenol Impression Material at Various Time Intervals After Mixing</title>
<author>
<name sortKey="Katna, Vishal" sort="Katna, Vishal" uniqKey="Katna V" first="Vishal" last="Katna">Vishal Katna</name>
<affiliation>
<nlm:aff id="Aff1">Department of Prosthodontics, Himachal Dental College and Hospital, Sundernagar, 174401 District Mandi, Himachal Pradesh India</nlm:aff>
<wicri:noCountry code="subfield">Himachal Pradesh India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Suresh, S" sort="Suresh, S" uniqKey="Suresh S" first="S." last="Suresh">S. Suresh</name>
<affiliation>
<nlm:aff id="Aff2">Department of Prosthodontics, Oxford Dental College and Hospital, Bangalore, Karnataka India</nlm:aff>
<wicri:noCountry code="subfield">Karnataka India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Vivek, Sharma" sort="Vivek, Sharma" uniqKey="Vivek S" first="Sharma" last="Vivek">Sharma Vivek</name>
<affiliation>
<nlm:aff id="Aff3">Department of Prosthodontics, Darshan Dental College and Hospital, Udaipur, Rajasthan India</nlm:aff>
<wicri:noCountry code="subfield">Rajasthan India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Meenakshi, Khandelwal" sort="Meenakshi, Khandelwal" uniqKey="Meenakshi K" first="Khandelwal" last="Meenakshi">Khandelwal Meenakshi</name>
<affiliation>
<nlm:aff id="Aff3">Department of Prosthodontics, Darshan Dental College and Hospital, Udaipur, Rajasthan India</nlm:aff>
<wicri:noCountry code="subfield">Rajasthan India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Ankita, Gaur" sort="Ankita, Gaur" uniqKey="Ankita G" first="Gaur" last="Ankita">Gaur Ankita</name>
<affiliation>
<nlm:aff id="Aff4">Department of Pedodontics, Himachal Dental College and Hospital, Sundernagar, 175002 District Mandi, Himachal Pradesh India</nlm:aff>
<wicri:noCountry code="subfield">Himachal Pradesh India</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">25489163</idno>
<idno type="pmc">4257930</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4257930</idno>
<idno type="RBID">PMC:4257930</idno>
<idno type="doi">10.1007/s13191-013-0338-7</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">000062</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000062</idno>
<idno type="wicri:Area/Pmc/Curation">000062</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000062</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000034</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">000034</idno>
<idno type="wicri:Area/Ncbi/Merge">001472</idno>
<idno type="wicri:Area/Ncbi/Curation">001472</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001472</idno>
<idno type="wicri:doubleKey">0972-4052:2014:Katna V:to:study:the</idno>
<idno type="wicri:Area/Main/Merge">000287</idno>
<idno type="wicri:Area/Main/Curation">000287</idno>
<idno type="wicri:Area/Main/Exploration">000287</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">To Study the Flow Property of Seven Commercially Available Zinc Oxide Eugenol Impression Material at Various Time Intervals After Mixing</title>
<author>
<name sortKey="Katna, Vishal" sort="Katna, Vishal" uniqKey="Katna V" first="Vishal" last="Katna">Vishal Katna</name>
<affiliation>
<nlm:aff id="Aff1">Department of Prosthodontics, Himachal Dental College and Hospital, Sundernagar, 174401 District Mandi, Himachal Pradesh India</nlm:aff>
<wicri:noCountry code="subfield">Himachal Pradesh India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Suresh, S" sort="Suresh, S" uniqKey="Suresh S" first="S." last="Suresh">S. Suresh</name>
<affiliation>
<nlm:aff id="Aff2">Department of Prosthodontics, Oxford Dental College and Hospital, Bangalore, Karnataka India</nlm:aff>
<wicri:noCountry code="subfield">Karnataka India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Vivek, Sharma" sort="Vivek, Sharma" uniqKey="Vivek S" first="Sharma" last="Vivek">Sharma Vivek</name>
<affiliation>
<nlm:aff id="Aff3">Department of Prosthodontics, Darshan Dental College and Hospital, Udaipur, Rajasthan India</nlm:aff>
<wicri:noCountry code="subfield">Rajasthan India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Meenakshi, Khandelwal" sort="Meenakshi, Khandelwal" uniqKey="Meenakshi K" first="Khandelwal" last="Meenakshi">Khandelwal Meenakshi</name>
<affiliation>
<nlm:aff id="Aff3">Department of Prosthodontics, Darshan Dental College and Hospital, Udaipur, Rajasthan India</nlm:aff>
<wicri:noCountry code="subfield">Rajasthan India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Ankita, Gaur" sort="Ankita, Gaur" uniqKey="Ankita G" first="Gaur" last="Ankita">Gaur Ankita</name>
<affiliation>
<nlm:aff id="Aff4">Department of Pedodontics, Himachal Dental College and Hospital, Sundernagar, 175002 District Mandi, Himachal Pradesh India</nlm:aff>
<wicri:noCountry code="subfield">Himachal Pradesh India</wicri:noCountry>
</affiliation>
</author>
</analytic>
<series>
<title level="j">The Journal of the Indian Prosthodontic Society</title>
<idno type="ISSN">0972-4052</idno>
<idno type="eISSN">1998-4057</idno>
<imprint>
<date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>Aims and objective of the study was to evaluate the flow property of seven commercially available zinc oxide eugenol impression materials at various time intervals, after mixing 49 samples (seven groups) were fabricated for flow property of the material. The sample were fabricated as equal length of base and accelerator paste of the test materials was taken on the glass slab and mixed with a rigid stainless steel spatula as per manufacturers recommendation till the homogenous mix was obtained. The mix material was loaded in glass syringe and 0.5 ml material was injected on a cellophane sheet placed on marked glass plate. A cellophane sheet and glass plate 70 and 500 g weight was carefully placed on freshly dispensed zinc oxide eugenol impression paste sequentially. The diameter of the mix was noted after 30 s and 1 min of load application and also after the final set of material. The diameter gives the flow of material. The samples were stored at the room temperature. The data of the flow property was analyzed with analysis of variance, Post hoc test and
<italic>t</italic>
test. The flow of the zinc oxide eugenol impression paste after 30 s, 1 min and final set of load application for Group A to Group G was noted. Maximum flow was seen for Group G zinc oxide eugenol impression material followed by Group F, D, E, B, C and A in descending order respectively after 30 s, where as the flow property changed after 1 min in the sequence of maximum for Group G followed by Group E, D, B, A, C, and F. Lastly after final set of the impression material the flow maximum for Group G followed by Group E, D, C, F, A and B in descending order. Based on statistical analysis of the results and within in the limitations of this in-vitro study, the following conclusions were drawn that; the flow of zinc oxide eugenol impression material after 30 s, 1 min and that after the final set was maximum for P.S.P. (Group G) and the flow for PYREX (Group A) was minimum.</p>
</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Ankita, Gaur" sort="Ankita, Gaur" uniqKey="Ankita G" first="Gaur" last="Ankita">Gaur Ankita</name>
<name sortKey="Katna, Vishal" sort="Katna, Vishal" uniqKey="Katna V" first="Vishal" last="Katna">Vishal Katna</name>
<name sortKey="Meenakshi, Khandelwal" sort="Meenakshi, Khandelwal" uniqKey="Meenakshi K" first="Khandelwal" last="Meenakshi">Khandelwal Meenakshi</name>
<name sortKey="Suresh, S" sort="Suresh, S" uniqKey="Suresh S" first="S." last="Suresh">S. Suresh</name>
<name sortKey="Vivek, Sharma" sort="Vivek, Sharma" uniqKey="Vivek S" first="Sharma" last="Vivek">Sharma Vivek</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000287 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000287 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:4257930
   |texte=   To Study the Flow Property of Seven Commercially Available Zinc Oxide Eugenol Impression Material at Various Time Intervals After Mixing
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:25489163" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020