A new quantitative screening method for removable prosthesis using pressure‐indicating paste
Identifieur interne : 000E05 ( Main/Curation ); précédent : 000E04; suivant : 000E06A new quantitative screening method for removable prosthesis using pressure‐indicating paste
Auteurs : T. Sanagawa [Japon] ; T. Hara [Japon] ; S. Minagi [Japon]Source :
- Journal of Oral Rehabilitation [ 0305-182X ] ; 2014-10.
Descripteurs français
- KwdFr :
- MESH :
- rééducation et réadaptation : Mâchoire partiellement édentée.
- Femelle, Humains, Modèles logistiques, Mâle, Onguents, Prothèse dentaire partielle amovible, Résultat thérapeutique, Sensibilité et spécificité.
English descriptors
- KwdEn :
- MESH :
- chemical : Ointments.
- rehabilitation : Jaw, Edentulous, Partially.
- Denture, Partial, Removable, Female, Humans, Logistic Models, Male, Sensitivity and Specificity, Treatment Outcome.
Abstract
Aim of this study was to quantitatively evaluate the adaptation of the denture base to the mucosa using a non‐setting pressure‐indicating paste and to examine the relationship between quality of fit and the need for denture relining. A total of 123 dentures from 70 partially edentulous patients were studied. Examination paste extruded from the tip of the 18‐G needle was applied to those denture surfaces contacting the alveolar crest. The denture was manually positioned with all clasps engaged on abutment teeth, and adaptation was assessed through paste distribution. Multiple logistic regression was used to analyse variables associated with diagnosing the need for a denture reline, producing odds ratios and 95% confidence intervals. The spread width was inversely proportional to the gap between the denture and mucosa. Regression analysis revealed statistically significant associations between the need for a denture reline and both the paste spread width and the duration of denture use. According to ROC curve analysis of the ‘reline’ and ‘non‐reline’ groups, the need for a denture reline was indicated at a paste spread width of 2·0 mm or less. At this 2·0‐mm threshold, the sensitivity was 85·1% and the specificity was 75·0%. The fit of removable denture bases was quantitatively evaluated by measuring the spread width of non‐setting pressure‐indicating paste extruded onto denture fit surfaces. The results suggest that the paste spread width is a useful parameter for discriminating the need for a denture reline.
Url:
DOI: 10.1111/joor.12200
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000713
- to stream Istex, to step Curation: Pour aller vers cette notice dans l'étape Curation :000713
- to stream Istex, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :000268
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000A24
- to stream PubMed, to step Curation: Pour aller vers cette notice dans l'étape Curation :000A24
- to stream PubMed, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :000A24
- to stream Ncbi, to step Merge: Pour aller vers cette notice dans l'étape Curation :000D83
- to stream Ncbi, to step Curation: Pour aller vers cette notice dans l'étape Curation :000D83
- to stream Ncbi, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :000D83
- to stream Main, to step Merge: Pour aller vers cette notice dans l'étape Curation :000E07
Links to Exploration step
ISTEX:BD4D7078768DAEC9054B8A5304D9FD32DA93B821Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">A new quantitative screening method for removable prosthesis using pressure‐indicating paste</title>
<author><name sortKey="Sanagawa, T" sort="Sanagawa, T" uniqKey="Sanagawa T" first="T." last="Sanagawa">T. Sanagawa</name>
</author>
<author><name sortKey="Hara, T" sort="Hara, T" uniqKey="Hara T" first="T." last="Hara">T. Hara</name>
</author>
<author><name sortKey="Minagi, S" sort="Minagi, S" uniqKey="Minagi S" first="S." last="Minagi">S. Minagi</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:BD4D7078768DAEC9054B8A5304D9FD32DA93B821</idno>
<date when="2014" year="2014">2014</date>
<idno type="doi">10.1111/joor.12200</idno>
<idno type="url">https://api.istex.fr/document/BD4D7078768DAEC9054B8A5304D9FD32DA93B821/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000713</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000713</idno>
<idno type="wicri:Area/Istex/Curation">000713</idno>
<idno type="wicri:Area/Istex/Checkpoint">000268</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000268</idno>
<idno type="wicri:doubleKey">0305-182X:2014:Sanagawa T:a:new:quantitative</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:24894573</idno>
<idno type="wicri:Area/PubMed/Corpus">000A24</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000A24</idno>
<idno type="wicri:Area/PubMed/Curation">000A24</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000A24</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000A24</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000A24</idno>
<idno type="wicri:Area/Ncbi/Merge">000D83</idno>
<idno type="wicri:Area/Ncbi/Curation">000D83</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000D83</idno>
<idno type="wicri:Area/Main/Merge">000E07</idno>
<idno type="wicri:Area/Main/Curation">000E05</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">A new quantitative screening method for removable prosthesis using pressure‐indicating paste</title>
<author><name sortKey="Sanagawa, T" sort="Sanagawa, T" uniqKey="Sanagawa T" first="T." last="Sanagawa">T. Sanagawa</name>
<affiliation wicri:level="1"><country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Occlusal and Oral Functional Rehabilitation, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama</wicri:regionArea>
<wicri:noRegion>Okayama</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Hara, T" sort="Hara, T" uniqKey="Hara T" first="T." last="Hara">T. Hara</name>
<affiliation wicri:level="1"><country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Occlusal and Oral Functional Rehabilitation, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama</wicri:regionArea>
<wicri:noRegion>Okayama</wicri:noRegion>
</affiliation>
<affiliation></affiliation>
<affiliation wicri:level="1"><country wicri:rule="url">Japon</country>
</affiliation>
</author>
<author><name sortKey="Minagi, S" sort="Minagi, S" uniqKey="Minagi S" first="S." last="Minagi">S. Minagi</name>
<affiliation wicri:level="1"><country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Occlusal and Oral Functional Rehabilitation, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama</wicri:regionArea>
<wicri:noRegion>Okayama</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Journal of Oral Rehabilitation</title>
<title level="j" type="alt">JOURNAL OF ORAL REHABILITATION</title>
<idno type="ISSN">0305-182X</idno>
<idno type="eISSN">1365-2842</idno>
<imprint><biblScope unit="vol">41</biblScope>
<biblScope unit="issue">10</biblScope>
<biblScope unit="page" from="737">737</biblScope>
<biblScope unit="page" to="743">743</biblScope>
<biblScope unit="page-count">7</biblScope>
<date type="published" when="2014-10">2014-10</date>
</imprint>
<idno type="ISSN">0305-182X</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0305-182X</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Denture, Partial, Removable</term>
<term>Female</term>
<term>Humans</term>
<term>Jaw, Edentulous, Partially (rehabilitation)</term>
<term>Logistic Models</term>
<term>Male</term>
<term>Ointments</term>
<term>Sensitivity and Specificity</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Femelle</term>
<term>Humains</term>
<term>Modèles logistiques</term>
<term>Mâchoire partiellement édentée (rééducation et réadaptation)</term>
<term>Mâle</term>
<term>Onguents</term>
<term>Prothèse dentaire partielle amovible</term>
<term>Résultat thérapeutique</term>
<term>Sensibilité et spécificité</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Ointments</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" qualifier="rééducation et réadaptation" xml:lang="fr"><term>Mâchoire partiellement édentée</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Denture, Partial, Removable</term>
<term>Female</term>
<term>Humans</term>
<term>Logistic Models</term>
<term>Male</term>
<term>Sensitivity and Specificity</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Femelle</term>
<term>Humains</term>
<term>Modèles logistiques</term>
<term>Mâle</term>
<term>Onguents</term>
<term>Prothèse dentaire partielle amovible</term>
<term>Résultat thérapeutique</term>
<term>Sensibilité et spécificité</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">Aim of this study was to quantitatively evaluate the adaptation of the denture base to the mucosa using a non‐setting pressure‐indicating paste and to examine the relationship between quality of fit and the need for denture relining. A total of 123 dentures from 70 partially edentulous patients were studied. Examination paste extruded from the tip of the 18‐G needle was applied to those denture surfaces contacting the alveolar crest. The denture was manually positioned with all clasps engaged on abutment teeth, and adaptation was assessed through paste distribution. Multiple logistic regression was used to analyse variables associated with diagnosing the need for a denture reline, producing odds ratios and 95% confidence intervals. The spread width was inversely proportional to the gap between the denture and mucosa. Regression analysis revealed statistically significant associations between the need for a denture reline and both the paste spread width and the duration of denture use. According to ROC curve analysis of the ‘reline’ and ‘non‐reline’ groups, the need for a denture reline was indicated at a paste spread width of 2·0 mm or less. At this 2·0‐mm threshold, the sensitivity was 85·1% and the specificity was 75·0%. The fit of removable denture bases was quantitatively evaluated by measuring the spread width of non‐setting pressure‐indicating paste extruded onto denture fit surfaces. The results suggest that the paste spread width is a useful parameter for discriminating the need for a denture reline.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Main/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E05 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Curation/biblio.hfd -nk 000E05 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV1 |flux= Main |étape= Curation |type= RBID |clé= ISTEX:BD4D7078768DAEC9054B8A5304D9FD32DA93B821 |texte= A new quantitative screening method for removable prosthesis using pressure‐indicating paste }}
This area was generated with Dilib version V0.6.33. |