Serveur d'exploration sur le patient édenté (maquette)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Accuracy of full guided vs. half‐guided implant surgery

Identifieur interne : 000327 ( Istex/Corpus ); précédent : 000326; suivant : 000328

Accuracy of full guided vs. half‐guided implant surgery

Auteurs : S. Kühl ; S. Zürcher ; T. Mahid ; M. Müller-Gerbl ; A. Filippi ; P. Cattin

Source :

RBID : ISTEX:59AA222A8782BABBC4B2150A36F132307A9E3A82

English descriptors

Abstract

The benefit in terms of higher accuracy for full guided implant surgery (template based guided cavity preparation and guided implant insertion) compared with half‐guided surgery (template based guided cavity preparation and free‐handed, manual implant insertion) has not been proved till now.

Url:
DOI: 10.1111/j.1600-0501.2012.02484.x

Links to Exploration step

ISTEX:59AA222A8782BABBC4B2150A36F132307A9E3A82

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy of full guided vs. half‐guided implant surgery</title>
<author>
<name sortKey="Kuhl, S" sort="Kuhl, S" uniqKey="Kuhl S" first="S." last="Kühl">S. Kühl</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Zurcher, S" sort="Zurcher, S" uniqKey="Zurcher S" first="S." last="Zürcher">S. Zürcher</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>:S. KühlDepartment of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental medicine, University of Basel, Hebelstr. 3, 4056 Basel, SwitzerlandTel.: +41/(0)612671312Fax: +41/(0)612672607e‐mail:</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: Sebastian.kuehl@unibas.ch</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Mahid, T" sort="Mahid, T" uniqKey="Mahid T" first="T." last="Mahid">T. Mahid</name>
<affiliation>
<mods:affiliation>Medical Image Analysis Center, University of Basel c/o University Hospital Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Muller Erbl, M" sort="Muller Erbl, M" uniqKey="Muller Erbl M" first="M." last="Müller-Gerbl">M. Müller-Gerbl</name>
<affiliation>
<mods:affiliation>Institute of Anatomy, University of Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Filippi, A" sort="Filippi, A" uniqKey="Filippi A" first="A." last="Filippi">A. Filippi</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Cattin, P" sort="Cattin, P" uniqKey="Cattin P" first="P." last="Cattin">P. Cattin</name>
<affiliation>
<mods:affiliation>Medical Image Analysis Center, University of Basel c/o University Hospital Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:59AA222A8782BABBC4B2150A36F132307A9E3A82</idno>
<date when="2013" year="2013">2013</date>
<idno type="doi">10.1111/j.1600-0501.2012.02484.x</idno>
<idno type="url">https://api.istex.fr/document/59AA222A8782BABBC4B2150A36F132307A9E3A82/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000327</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000327</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Accuracy of full guided vs. half‐guided implant surgery</title>
<author>
<name sortKey="Kuhl, S" sort="Kuhl, S" uniqKey="Kuhl S" first="S." last="Kühl">S. Kühl</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Zurcher, S" sort="Zurcher, S" uniqKey="Zurcher S" first="S." last="Zürcher">S. Zürcher</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>:S. KühlDepartment of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental medicine, University of Basel, Hebelstr. 3, 4056 Basel, SwitzerlandTel.: +41/(0)612671312Fax: +41/(0)612672607e‐mail:</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: Sebastian.kuehl@unibas.ch</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Mahid, T" sort="Mahid, T" uniqKey="Mahid T" first="T." last="Mahid">T. Mahid</name>
<affiliation>
<mods:affiliation>Medical Image Analysis Center, University of Basel c/o University Hospital Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Muller Erbl, M" sort="Muller Erbl, M" uniqKey="Muller Erbl M" first="M." last="Müller-Gerbl">M. Müller-Gerbl</name>
<affiliation>
<mods:affiliation>Institute of Anatomy, University of Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Filippi, A" sort="Filippi, A" uniqKey="Filippi A" first="A." last="Filippi">A. Filippi</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Cattin, P" sort="Cattin, P" uniqKey="Cattin P" first="P." last="Cattin">P. Cattin</name>
<affiliation>
<mods:affiliation>Medical Image Analysis Center, University of Basel c/o University Hospital Basel, Basel, Switzerland</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint>
<biblScope unit="vol">24</biblScope>
<biblScope unit="issue">7</biblScope>
<biblScope unit="page" from="763">763</biblScope>
<biblScope unit="page" to="769">769</biblScope>
<biblScope unit="page-count">7</biblScope>
<date type="published" when="2013-07">2013-07</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Accuracy measurements</term>
<term>Anatomical landmarks</term>
<term>Apless surgery</term>
<term>Average error</term>
<term>Axial deviation</term>
<term>Basel</term>
<term>Bone density</term>
<term>Cavity preparation</term>
<term>Clin</term>
<term>Clinical studies</term>
<term>Codiagnostixtm device</term>
<term>Craniomaxillofacial surgery</term>
<term>Dental implantology</term>
<term>Dental implants</term>
<term>Depth control</term>
<term>Entry point</term>
<term>Full half</term>
<term>Halfguided implantation</term>
<term>Halfguided surgery</term>
<term>High accuracy</term>
<term>Higher accuracy</term>
<term>Identical implants</term>
<term>Image fusion</term>
<term>Implant</term>
<term>Implant dentistry</term>
<term>Implant insertion</term>
<term>Implant placement</term>
<term>Implant surgery</term>
<term>Implantation</term>
<term>Implantation modalities</term>
<term>Implantation modi</term>
<term>Implantation techniques</term>
<term>Implantology</term>
<term>Implantology table</term>
<term>Implants axis</term>
<term>Implants base</term>
<term>Implants bases</term>
<term>Implants position</term>
<term>Implants research</term>
<term>Implants tips</term>
<term>Insertion</term>
<term>Institut straumann</term>
<term>Institute straumann</term>
<term>International journal</term>
<term>Interocclusal distance</term>
<term>John wiley sons kuhl</term>
<term>Jung</term>
<term>Kennedy class</term>
<term>Kuhl</term>
<term>Main axis</term>
<term>Maxillofacial</term>
<term>Maximum deviation</term>
<term>Minimum deviation</term>
<term>Modality</term>
<term>Nickenig</term>
<term>Nickenig eitner</term>
<term>Oral maxillofacial implants</term>
<term>Oral medicine</term>
<term>Oral radiology</term>
<term>Oral rehabilitation</term>
<term>Oral surgery</term>
<term>Perfect depth control</term>
<term>Postoperative data</term>
<term>Primary stability</term>
<term>Principal component analysis</term>
<term>Real implant position</term>
<term>Schneider</term>
<term>Slight movements</term>
<term>Soft tissue punches</term>
<term>Static systems</term>
<term>Straumann</term>
<term>Surgery</term>
<term>Surgical</term>
<term>Surgical procedure</term>
<term>Systematic review</term>
<term>Template</term>
<term>Template fabrication</term>
<term>Tissue level</term>
<term>Total deviation</term>
<term>Virtual implant planning</term>
<term>Virtual implant position</term>
<term>Virtual planning</term>
<term>Vital structures</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Accuracy measurements</term>
<term>Anatomical landmarks</term>
<term>Apless surgery</term>
<term>Average error</term>
<term>Axial deviation</term>
<term>Basel</term>
<term>Bone density</term>
<term>Cavity preparation</term>
<term>Clin</term>
<term>Clinical studies</term>
<term>Codiagnostixtm device</term>
<term>Craniomaxillofacial surgery</term>
<term>Dental implantology</term>
<term>Dental implants</term>
<term>Depth control</term>
<term>Entry point</term>
<term>Full half</term>
<term>Halfguided implantation</term>
<term>Halfguided surgery</term>
<term>High accuracy</term>
<term>Higher accuracy</term>
<term>Identical implants</term>
<term>Image fusion</term>
<term>Implant</term>
<term>Implant dentistry</term>
<term>Implant insertion</term>
<term>Implant placement</term>
<term>Implant surgery</term>
<term>Implantation</term>
<term>Implantation modalities</term>
<term>Implantation modi</term>
<term>Implantation techniques</term>
<term>Implantology</term>
<term>Implantology table</term>
<term>Implants axis</term>
<term>Implants base</term>
<term>Implants bases</term>
<term>Implants position</term>
<term>Implants research</term>
<term>Implants tips</term>
<term>Insertion</term>
<term>Institut straumann</term>
<term>Institute straumann</term>
<term>International journal</term>
<term>Interocclusal distance</term>
<term>John wiley sons kuhl</term>
<term>Jung</term>
<term>Kennedy class</term>
<term>Kuhl</term>
<term>Main axis</term>
<term>Maxillofacial</term>
<term>Maximum deviation</term>
<term>Minimum deviation</term>
<term>Modality</term>
<term>Nickenig</term>
<term>Nickenig eitner</term>
<term>Oral maxillofacial implants</term>
<term>Oral medicine</term>
<term>Oral radiology</term>
<term>Oral rehabilitation</term>
<term>Oral surgery</term>
<term>Perfect depth control</term>
<term>Postoperative data</term>
<term>Primary stability</term>
<term>Principal component analysis</term>
<term>Real implant position</term>
<term>Schneider</term>
<term>Slight movements</term>
<term>Soft tissue punches</term>
<term>Static systems</term>
<term>Straumann</term>
<term>Surgery</term>
<term>Surgical</term>
<term>Surgical procedure</term>
<term>Systematic review</term>
<term>Template</term>
<term>Template fabrication</term>
<term>Tissue level</term>
<term>Total deviation</term>
<term>Virtual implant planning</term>
<term>Virtual implant position</term>
<term>Virtual planning</term>
<term>Vital structures</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">The benefit in terms of higher accuracy for full guided implant surgery (template based guided cavity preparation and guided implant insertion) compared with half‐guided surgery (template based guided cavity preparation and free‐handed, manual implant insertion) has not been proved till now.</div>
</front>
</TEI>
<istex>
<corpusName>wiley</corpusName>
<keywords>
<teeft>
<json:string>implant</json:string>
<json:string>implantation</json:string>
<json:string>straumann</json:string>
<json:string>implantology</json:string>
<json:string>jung</json:string>
<json:string>kuhl</json:string>
<json:string>full half</json:string>
<json:string>modality</json:string>
<json:string>total deviation</json:string>
<json:string>implants bases</json:string>
<json:string>clin</json:string>
<json:string>nickenig</json:string>
<json:string>maxillofacial</json:string>
<json:string>schneider</json:string>
<json:string>implant insertion</json:string>
<json:string>international journal</json:string>
<json:string>insertion</json:string>
<json:string>higher accuracy</json:string>
<json:string>surgical</json:string>
<json:string>high accuracy</json:string>
<json:string>entry point</json:string>
<json:string>nickenig eitner</json:string>
<json:string>implant surgery</json:string>
<json:string>implants tips</json:string>
<json:string>cavity preparation</json:string>
<json:string>real implant position</json:string>
<json:string>implant dentistry</json:string>
<json:string>institut straumann</json:string>
<json:string>maximum deviation</json:string>
<json:string>template</json:string>
<json:string>surgery</json:string>
<json:string>implantation modalities</json:string>
<json:string>anatomical landmarks</json:string>
<json:string>static systems</json:string>
<json:string>minimum deviation</json:string>
<json:string>systematic review</json:string>
<json:string>implants research</json:string>
<json:string>oral rehabilitation</json:string>
<json:string>implants base</json:string>
<json:string>virtual planning</json:string>
<json:string>main axis</json:string>
<json:string>dental implantology</json:string>
<json:string>implants axis</json:string>
<json:string>kennedy class</json:string>
<json:string>oral maxillofacial implants</json:string>
<json:string>institute straumann</json:string>
<json:string>implantation modi</json:string>
<json:string>john wiley sons kuhl</json:string>
<json:string>virtual implant planning</json:string>
<json:string>basel</json:string>
<json:string>implants position</json:string>
<json:string>tissue level</json:string>
<json:string>template fabrication</json:string>
<json:string>slight movements</json:string>
<json:string>accuracy measurements</json:string>
<json:string>halfguided implantation</json:string>
<json:string>primary stability</json:string>
<json:string>postoperative data</json:string>
<json:string>interocclusal distance</json:string>
<json:string>principal component analysis</json:string>
<json:string>apless surgery</json:string>
<json:string>axial deviation</json:string>
<json:string>virtual implant position</json:string>
<json:string>perfect depth control</json:string>
<json:string>average error</json:string>
<json:string>surgical procedure</json:string>
<json:string>depth control</json:string>
<json:string>vital structures</json:string>
<json:string>image fusion</json:string>
<json:string>identical implants</json:string>
<json:string>codiagnostixtm device</json:string>
<json:string>implantology table</json:string>
<json:string>clinical studies</json:string>
<json:string>implantation techniques</json:string>
<json:string>bone density</json:string>
<json:string>implant placement</json:string>
<json:string>dental implants</json:string>
<json:string>soft tissue punches</json:string>
<json:string>oral medicine</json:string>
<json:string>oral radiology</json:string>
<json:string>oral surgery</json:string>
<json:string>craniomaxillofacial surgery</json:string>
<json:string>halfguided surgery</json:string>
</teeft>
</keywords>
<author>
<json:item>
<name>S. Kühl</name>
<affiliations>
<json:string>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</json:string>
</affiliations>
</json:item>
<json:item>
<name>S. Zürcher</name>
<affiliations>
<json:string>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</json:string>
<json:string>:S. KühlDepartment of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental medicine, University of Basel, Hebelstr. 3, 4056 Basel, SwitzerlandTel.: +41/(0)612671312Fax: +41/(0)612672607e‐mail:</json:string>
<json:string>E-mail: Sebastian.kuehl@unibas.ch</json:string>
</affiliations>
</json:item>
<json:item>
<name>T. Mahid</name>
<affiliations>
<json:string>Medical Image Analysis Center, University of Basel c/o University Hospital Basel, Basel, Switzerland</json:string>
</affiliations>
</json:item>
<json:item>
<name>M. Müller‐Gerbl</name>
<affiliations>
<json:string>Institute of Anatomy, University of Basel, Basel, Switzerland</json:string>
</affiliations>
</json:item>
<json:item>
<name>A. Filippi</name>
<affiliations>
<json:string>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</json:string>
</affiliations>
</json:item>
<json:item>
<name>P. Cattin</name>
<affiliations>
<json:string>Medical Image Analysis Center, University of Basel c/o University Hospital Basel, Basel, Switzerland</json:string>
</affiliations>
</json:item>
</author>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>dental implants</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>guidance</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>templates</value>
</json:item>
</subject>
<articleId>
<json:string>CLR2484</json:string>
</articleId>
<arkIstex>ark:/67375/WNG-ZHRLSWSQ-L</arkIstex>
<language>
<json:string>eng</json:string>
</language>
<originalGenre>
<json:string>article</json:string>
</originalGenre>
<abstract>The benefit in terms of higher accuracy for full guided implant surgery (template based guided cavity preparation and guided implant insertion) compared with half‐guided surgery (template based guided cavity preparation and free‐handed, manual implant insertion) has not been proved till now.</abstract>
<qualityIndicators>
<score>6.932</score>
<pdfWordCount>4440</pdfWordCount>
<pdfCharCount>29686</pdfCharCount>
<pdfVersion>1.7</pdfVersion>
<pdfPageCount>7</pdfPageCount>
<pdfPageSize>595.276 x 782.362 pts</pdfPageSize>
<refBibsNative>true</refBibsNative>
<abstractWordCount>41</abstractWordCount>
<abstractCharCount>292</abstractCharCount>
<keywordCount>3</keywordCount>
</qualityIndicators>
<title>Accuracy of full guided vs. half‐guided implant surgery</title>
<pmid>
<json:string>22551385</json:string>
</pmid>
<genre>
<json:string>article</json:string>
</genre>
<host>
<title>Clinical Oral Implants Research</title>
<language>
<json:string>unknown</json:string>
</language>
<doi>
<json:string>10.1111/(ISSN)1600-0501</json:string>
</doi>
<issn>
<json:string>0905-7161</json:string>
</issn>
<eissn>
<json:string>1600-0501</json:string>
</eissn>
<publisherId>
<json:string>CLR</json:string>
</publisherId>
<volume>24</volume>
<issue>7</issue>
<pages>
<first>763</first>
<last>769</last>
<total>7</total>
</pages>
<genre>
<json:string>journal</json:string>
</genre>
<subject>
<json:item>
<value>Original Research Article</value>
</json:item>
</subject>
</host>
<namedEntities>
<unitex>
<date>
<json:string>2012-04-03</json:string>
</date>
<geogName></geogName>
<orgName>
<json:string>Switzerland Key</json:string>
<json:string>University of Basel</json:string>
<json:string>Medical Image Analysis Center</json:string>
<json:string>Institute Straumann AG, Basel, Switzerland</json:string>
<json:string>Department of Oral Surgery, Oral Radiology and Oral Medicine</json:string>
<json:string>University Hospital Basel, Basel, Switzerland M</json:string>
<json:string>Switzerland Tel</json:string>
<json:string>Institute of Anatomy, University</json:string>
<json:string>Institute Straumann AG</json:string>
</orgName>
<orgName_funder></orgName_funder>
<orgName_provider></orgName_provider>
<persName>
<json:string>John Wiley</json:string>
<json:string>Max Mean</json:string>
<json:string>Component</json:string>
<json:string>Peter Muller</json:string>
<json:string>T. Mahid</json:string>
<json:string>S. Kuhl</json:string>
<json:string>P. Accuracy</json:string>
<json:string>Min Mean</json:string>
<json:string>Mahid M. Muller-Gerbl</json:string>
<json:string>Irene Mischak</json:string>
<json:string>S. Zurcher</json:string>
<json:string>P. Cattin</json:string>
<json:string>A. Filippi</json:string>
</persName>
<placeName>
<json:string>Switzerland</json:string>
<json:string>Germany</json:string>
<json:string>Europe</json:string>
<json:string>Basel</json:string>
</placeName>
<ref_url></ref_url>
<ref_bibl>
<json:string>Schneider et al.</json:string>
<json:string>Ozan et al. 2009</json:string>
<json:string>Ruppin et al. 2008</json:string>
<json:string>Nickening et al.</json:string>
<json:string>Ewers et al. 2005</json:string>
<json:string>Jung et al.</json:string>
<json:string>Hammerle et al. 2009</json:string>
<json:string>Haese et al. 2010</json:string>
<json:string>Schneider et al. 2009</json:string>
<json:string>Jabero & Sarment 2006</json:string>
<json:string>Arisan et al. 2010</json:string>
<json:string>Kuhl et al.</json:string>
<json:string>Jung et al. 2009</json:string>
<json:string>Miller & Bier 2006</json:string>
<json:string>Fortin et al. 2007</json:string>
<json:string>Verstreken et al. 1996</json:string>
<json:string>Ozan et al. 2011</json:string>
<json:string>Katsoulis et al. 2009</json:string>
<json:string>Wittwer et al. 2007</json:string>
<json:string>Vasak et al. 2011</json:string>
<json:string>Nickenig & Eitner 2010</json:string>
<json:string>Vercruyssen et al. 2008</json:string>
<json:string>Jolliffe 2002</json:string>
</ref_bibl>
<bibl></bibl>
</unitex>
</namedEntities>
<ark>
<json:string>ark:/67375/WNG-ZHRLSWSQ-L</json:string>
</ark>
<categories>
<wos>
<json:string>1 - science</json:string>
<json:string>2 - engineering, biomedical</json:string>
<json:string>2 - dentistry, oral surgery & medicine</json:string>
</wos>
<scienceMetrix>
<json:string>1 - health sciences</json:string>
<json:string>2 - clinical medicine</json:string>
<json:string>3 - dentistry</json:string>
</scienceMetrix>
<scopus>
<json:string>1 - Health Sciences</json:string>
<json:string>2 - Dentistry</json:string>
<json:string>3 - Oral Surgery</json:string>
</scopus>
</categories>
<publicationDate>2013</publicationDate>
<copyrightDate>2013</copyrightDate>
<doi>
<json:string>10.1111/j.1600-0501.2012.02484.x</json:string>
</doi>
<id>59AA222A8782BABBC4B2150A36F132307A9E3A82</id>
<score>1</score>
<fulltext>
<json:item>
<extension>pdf</extension>
<original>true</original>
<mimetype>application/pdf</mimetype>
<uri>https://api.istex.fr/document/59AA222A8782BABBC4B2150A36F132307A9E3A82/fulltext/pdf</uri>
</json:item>
<json:item>
<extension>zip</extension>
<original>false</original>
<mimetype>application/zip</mimetype>
<uri>https://api.istex.fr/document/59AA222A8782BABBC4B2150A36F132307A9E3A82/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/59AA222A8782BABBC4B2150A36F132307A9E3A82/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a" type="main">Accuracy of full guided vs. half‐guided implant surgery</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>Wiley Publishing Ltd</publisher>
<availability>
<licence>© 2012 John Wiley & Sons A/S</licence>
</availability>
<date type="published" when="2013-07"></date>
</publicationStmt>
<notesStmt>
<note type="content-type" subtype="article" source="article" scheme="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</note>
<note type="publication-type" subtype="journal" scheme="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</note>
</notesStmt>
<sourceDesc>
<biblStruct type="article">
<analytic>
<title level="a" type="main">Accuracy of full guided vs. half‐guided implant surgery</title>
<author xml:id="author-0000">
<persName>
<forename type="first">S.</forename>
<surname>Kühl</surname>
</persName>
<affiliation>
<orgName>Department of Oral Surgery</orgName>
<orgName>School of Dental medicine</orgName>
<orgName>Oral Radiology and Oral Medicine</orgName>
<orgName>University of Basel</orgName>
<address>
<settlement type="city">Basel</settlement>
<country key="CH">Switzerland</country>
</address>
</affiliation>
</author>
<author xml:id="author-0001" role="corresp">
<persName>
<forename type="first">S.</forename>
<surname>Zürcher</surname>
</persName>
<affiliation>
<orgName>Department of Oral Surgery</orgName>
<orgName>School of Dental medicine</orgName>
<orgName>Oral Radiology and Oral Medicine</orgName>
<orgName>University of Basel</orgName>
<address>
<settlement type="city">Basel</settlement>
<country key="CH">Switzerland</country>
</address>
</affiliation>
<affiliation>Corresponding author: S. Kühl Department of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental medicine, University of Basel, Hebelstr. 3, 4056 Basel, Switzerland Tel.: +41/(0)612671312 Fax: +41/(0)612672607 e‐mail: Sebastian.kuehl@unibas.ch</affiliation>
</author>
<author xml:id="author-0002">
<persName>
<forename type="first">T.</forename>
<surname>Mahid</surname>
</persName>
<affiliation>
<orgName>Medical Image Analysis Center</orgName>
<orgName>University of Basel c/o University Hospital Basel</orgName>
<address>
<settlement type="city">Basel</settlement>
<country key="CH">Switzerland</country>
</address>
</affiliation>
</author>
<author xml:id="author-0003">
<persName>
<forename type="first">M.</forename>
<surname>Müller‐Gerbl</surname>
</persName>
<affiliation>
<orgName>Institute of Anatomy</orgName>
<orgName>University of Basel</orgName>
<address>
<settlement type="city">Basel</settlement>
<country key="CH">Switzerland</country>
</address>
</affiliation>
</author>
<author xml:id="author-0004">
<persName>
<forename type="first">A.</forename>
<surname>Filippi</surname>
</persName>
<affiliation>
<orgName>Department of Oral Surgery</orgName>
<orgName>School of Dental medicine</orgName>
<orgName>Oral Radiology and Oral Medicine</orgName>
<orgName>University of Basel</orgName>
<address>
<settlement type="city">Basel</settlement>
<country key="CH">Switzerland</country>
</address>
</affiliation>
</author>
<author xml:id="author-0005">
<persName>
<forename type="first">P.</forename>
<surname>Cattin</surname>
</persName>
<affiliation>
<orgName>Medical Image Analysis Center</orgName>
<orgName>University of Basel c/o University Hospital Basel</orgName>
<address>
<settlement type="city">Basel</settlement>
<country key="CH">Switzerland</country>
</address>
</affiliation>
</author>
<idno type="istex">59AA222A8782BABBC4B2150A36F132307A9E3A82</idno>
<idno type="ark">ark:/67375/WNG-ZHRLSWSQ-L</idno>
<idno type="DOI">10.1111/j.1600-0501.2012.02484.x</idno>
<idno type="unit">CLR2484</idno>
<idno type="toTypesetVersion">file:CLR.CLR2484.pdf</idno>
</analytic>
<monogr>
<title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="pISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<idno type="book-DOI">10.1111/(ISSN)1600-0501</idno>
<idno type="book-part-DOI">10.1111/clr.2013.24.issue-7</idno>
<idno type="product">CLR</idno>
<imprint>
<biblScope unit="vol">24</biblScope>
<biblScope unit="issue">7</biblScope>
<biblScope unit="page" from="763">763</biblScope>
<biblScope unit="page" to="769">769</biblScope>
<biblScope unit="page-count">7</biblScope>
<date type="published" when="2013-07"></date>
</imprint>
</monogr>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<abstract style="main" xml:id="clr2484-abs-0001">
<head>Abstract</head>
Objectives
<p>The benefit in terms of higher accuracy for full guided implant surgery (template based guided cavity preparation and guided implant insertion) compared with half‐guided surgery (template based guided cavity preparation and free‐handed, manual implant insertion) has not been proved till now.</p>
Material and methods
<p>A total of 38 identical implants were inserted into five human cadaver jaws, after virtual implant planning with the coDiagnostiX
<hi rend="superscript"></hi>
device. All cavities were drilled using templates equipped with tubes for guidance. At random, 19 implants were inserted in a free handed way (half‐guided), whereas 19 implants were inserted in a guided way through the templates tubes (full guided). Postoperative cone beam computer tomographies (
<hi rend="fc">CBCT</hi>
) were performed, and based on image fusion the total deviations between the virtual implant positions at the implants base and tip were determined and compared between both implantation modi.</p>
Results
<p>The mean difference in accuracy between both implantation modalities at the implants bases was 0.72 mm (range: 0.16–1.17 mm, SD: 0.45). The mean difference in accuracy between both modalities at the implants tips was 0.46 mm (range: 0.16–1.23 mm. SD: 0.49). Although full guided implantation showed a generally higher accuracy (mean tip: 1.54 mm, range: 0.33–3.64 mm; mean base: 1.52 mm, range: 0.4–3.54 mm) than half‐guided implantation (mean tip: 1.84 mm, range: 0.84–3.22 mm; mean base: 1.56 mm, range: 0.49–3.43 mm), the differences were not statistically significant.</p>
Conclusions
<p>The accuracy of half‐guided implant surgery is comparable with full guided implant surgery.</p>
</abstract>
<textClass>
<keywords>
<term xml:id="clr2484-kwd-0001">dental implants</term>
<term xml:id="clr2484-kwd-0002">guidance</term>
<term xml:id="clr2484-kwd-0003">templates</term>
</keywords>
<keywords rend="articleCategory">
<term>Original Research Article</term>
</keywords>
<keywords rend="tocHeading1">
<term>Original Articles</term>
</keywords>
</textClass>
<langUsage>
<language ident="en"></language>
</langUsage>
</profileDesc>
</teiHeader>
</istex:fulltextTEI>
<json:item>
<extension>txt</extension>
<original>false</original>
<mimetype>text/plain</mimetype>
<uri>https://api.istex.fr/document/59AA222A8782BABBC4B2150A36F132307A9E3A82/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Wiley, elements deleted: body">
<istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document>
<component type="serialArticle" version="2.0" xml:id="clr2484" xml:lang="en">
<header>
<publicationMeta level="product">
<doi origin="wiley" registered="yes">10.1111/(ISSN)1600-0501</doi>
<issn type="print">0905-7161</issn>
<issn type="electronic">1600-0501</issn>
<idGroup>
<id type="product" value="CLR"></id>
</idGroup>
<titleGroup>
<title sort="CLINICAL ORAL IMPLANTS RESEARCH" type="main">Clinical Oral Implants Research</title>
<title type="short">Clin. Oral. Implants. Res.</title>
</titleGroup>
</publicationMeta>
<publicationMeta level="part" position="70">
<doi origin="wiley">10.1111/clr.2013.24.issue-7</doi>
<copyright ownership="publisher">Copyright © 2013 John Wiley & Sons A/S</copyright>
<numberingGroup>
<numbering type="journalVolume" number="24">24</numbering>
<numbering type="journalIssue">7</numbering>
</numberingGroup>
<coverDate startDate="2013-07">July 2013</coverDate>
</publicationMeta>
<publicationMeta level="unit" position="80" status="forIssue" type="article">
<doi>10.1111/j.1600-0501.2012.02484.x</doi>
<idGroup>
<id type="unit" value="CLR2484"></id>
</idGroup>
<countGroup>
<count number="7" type="pageTotal"></count>
</countGroup>
<titleGroup>
<title type="articleCategory">Original Research Article</title>
<title type="tocHeading1">Original Articles</title>
</titleGroup>
<copyright ownership="publisher">© 2012 John Wiley & Sons A/S</copyright>
<eventGroup>
<event date="2012-03-21" type="manuscriptAccepted"></event>
<event agent="SPS" date="2012-04-03" type="xmlCreated"></event>
<event type="publishedOnlineEarlyUnpaginated" date="2012-05-03"></event>
<event type="firstOnline" date="2012-05-03"></event>
<event type="publishedOnlineFinalForm" date="2013-06-04"></event>
<event type="xmlConverted" agent="Converter:WILEY_ML3G_TO_WILEY_ML3GV2 version:4.0.1" date="2014-03-12"></event>
<event type="xmlConverted" agent="Converter:WML3G_To_WML3G version:4.6.4 mode:FullText" date="2015-10-02"></event>
</eventGroup>
<numberingGroup>
<numbering type="pageFirst">763</numbering>
<numbering type="pageLast">769</numbering>
</numberingGroup>
<correspondenceTo>
<lineatedText>
<line>
<b>Corresponding author</b>
:</line>
<line>S. Kühl</line>
<line>Department of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental medicine, University of Basel, Hebelstr. 3, 4056 Basel, Switzerland</line>
<line>Tel.: +41/(0)612671312</line>
<line>Fax: +41/(0)612672607</line>
<line>e‐mail:
<email>Sebastian.kuehl@unibas.ch</email>
</line>
</lineatedText>
</correspondenceTo>
<selfCitationGroup>
<citation type="self" xml:id="clr2484-cit-0021">Kühl S, Zürcher S, Mahid T, Müller-Gerbl M, Filippi A, Cattin P. Accuracy of full guided vs. half-guided implant surgery.
<i>Clin. Oral Impl. Res.</i>
<b>24</b>
, 2013, 763–769</citation>
</selfCitationGroup>
<linkGroup>
<link type="toTypesetVersion" href="file:CLR.CLR2484.pdf"></link>
</linkGroup>
</publicationMeta>
<contentMeta>
<titleGroup>
<title type="main">Accuracy of full guided vs. half‐guided implant surgery</title>
<title type="shortAuthors">Kühl et al.</title>
</titleGroup>
<creators>
<creator affiliationRef="#clr2484-aff-0001" creatorRole="author" xml:id="clr2484-cr-0001">
<personName>
<givenNames>S.</givenNames>
<familyName>Kühl</familyName>
</personName>
</creator>
<creator affiliationRef="#clr2484-aff-0001" corresponding="yes" creatorRole="author" xml:id="clr2484-cr-0002">
<personName>
<givenNames>S.</givenNames>
<familyName>Zürcher</familyName>
</personName>
</creator>
<creator affiliationRef="#clr2484-aff-0002" creatorRole="author" xml:id="clr2484-cr-0003">
<personName>
<givenNames>T.</givenNames>
<familyName>Mahid</familyName>
</personName>
</creator>
<creator affiliationRef="#clr2484-aff-0003" creatorRole="author" xml:id="clr2484-cr-0004">
<personName>
<givenNames>M.</givenNames>
<familyName>Müller‐Gerbl</familyName>
</personName>
</creator>
<creator affiliationRef="#clr2484-aff-0001" creatorRole="author" xml:id="clr2484-cr-0005">
<personName>
<givenNames>A.</givenNames>
<familyName>Filippi</familyName>
</personName>
</creator>
<creator affiliationRef="#clr2484-aff-0002" creatorRole="author" xml:id="clr2484-cr-0006">
<personName>
<givenNames>P.</givenNames>
<familyName>Cattin</familyName>
</personName>
</creator>
</creators>
<affiliationGroup>
<affiliation countryCode="CH" type="organization" xml:id="clr2484-aff-0001">
<orgDiv>Department of Oral Surgery</orgDiv>
<orgName>Oral Radiology and Oral Medicine</orgName>
<orgDiv>School of Dental medicine</orgDiv>
<orgName>University of Basel</orgName>
<address>
<city>Basel</city>
<country>Switzerland</country>
</address>
</affiliation>
<affiliation countryCode="CH" type="organization" xml:id="clr2484-aff-0002">
<orgDiv>Medical Image Analysis Center</orgDiv>
<orgName>University of Basel c/o University Hospital Basel</orgName>
<address>
<city>Basel</city>
<country>Switzerland</country>
</address>
</affiliation>
<affiliation countryCode="CH" type="organization" xml:id="clr2484-aff-0003">
<orgName>Institute of Anatomy</orgName>
<orgName>University of Basel</orgName>
<address>
<city>Basel</city>
<country>Switzerland</country>
</address>
</affiliation>
</affiliationGroup>
<keywordGroup type="author">
<keyword xml:id="clr2484-kwd-0001">dental implants</keyword>
<keyword xml:id="clr2484-kwd-0002">guidance</keyword>
<keyword xml:id="clr2484-kwd-0003">templates</keyword>
</keywordGroup>
<abstractGroup>
<abstract type="main" xml:id="clr2484-abs-0001">
<title type="main">Abstract</title>
<section xml:id="clr2484-sec-0001">
<title type="main">Objectives</title>
<p>The benefit in terms of higher accuracy for full guided implant surgery (template based guided cavity preparation and guided implant insertion) compared with half‐guided surgery (template based guided cavity preparation and free‐handed, manual implant insertion) has not been proved till now.</p>
</section>
<section xml:id="clr2484-sec-0002">
<title type="main">Material and methods</title>
<p>A total of 38 identical implants were inserted into five human cadaver jaws, after virtual implant planning with the coDiagnostiX
<sup></sup>
device. All cavities were drilled using templates equipped with tubes for guidance. At random, 19 implants were inserted in a free handed way (half‐guided), whereas 19 implants were inserted in a guided way through the templates tubes (full guided). Postoperative cone beam computer tomographies (
<fc>CBCT</fc>
) were performed, and based on image fusion the total deviations between the virtual implant positions at the implants base and tip were determined and compared between both implantation modi.</p>
</section>
<section xml:id="clr2484-sec-0003">
<title type="main">Results</title>
<p>The mean difference in accuracy between both implantation modalities at the implants bases was 0.72 mm (range: 0.16–1.17 mm, SD: 0.45). The mean difference in accuracy between both modalities at the implants tips was 0.46 mm (range: 0.16–1.23 mm. SD: 0.49). Although full guided implantation showed a generally higher accuracy (mean tip: 1.54 mm, range: 0.33–3.64 mm; mean base: 1.52 mm, range: 0.4–3.54 mm) than half‐guided implantation (mean tip: 1.84 mm, range: 0.84–3.22 mm; mean base: 1.56 mm, range: 0.49–3.43 mm), the differences were not statistically significant.</p>
</section>
<section xml:id="clr2484-sec-0004">
<title type="main">Conclusions</title>
<p>The accuracy of half‐guided implant surgery is comparable with full guided implant surgery.</p>
</section>
</abstract>
</abstractGroup>
</contentMeta>
</header>
</component>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo lang="en">
<title>Accuracy of full guided vs. half‐guided implant surgery</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en">
<title>Accuracy of full guided vs. half‐guided implant surgery</title>
</titleInfo>
<name type="personal">
<namePart type="given">S.</namePart>
<namePart type="family">Kühl</namePart>
<affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">S.</namePart>
<namePart type="family">Zürcher</namePart>
<affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</affiliation>
<affiliation>:S. KühlDepartment of Oral Surgery, Oral Radiology and Oral Medicine, School of Dental medicine, University of Basel, Hebelstr. 3, 4056 Basel, SwitzerlandTel.: +41/(0)612671312Fax: +41/(0)612672607e‐mail:</affiliation>
<affiliation>E-mail: Sebastian.kuehl@unibas.ch</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">T.</namePart>
<namePart type="family">Mahid</namePart>
<affiliation>Medical Image Analysis Center, University of Basel c/o University Hospital Basel, Basel, Switzerland</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">M.</namePart>
<namePart type="family">Müller‐Gerbl</namePart>
<affiliation>Institute of Anatomy, University of Basel, Basel, Switzerland</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">A.</namePart>
<namePart type="family">Filippi</namePart>
<affiliation>Department of Oral Surgery, School of Dental medicine, Oral Radiology and Oral Medicine, University of Basel, Basel, Switzerland</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">P.</namePart>
<namePart type="family">Cattin</namePart>
<affiliation>Medical Image Analysis Center, University of Basel c/o University Hospital Basel, Basel, Switzerland</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="article" displayLabel="article" authority="ISTEX" authorityURI="https://content-type.data.istex.fr" valueURI="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</genre>
<originInfo>
<publisher>Blackwell Publishing Ltd</publisher>
<dateIssued encoding="w3cdtf">2013-07</dateIssued>
<dateCreated encoding="w3cdtf">2012-04-03</dateCreated>
<dateValid encoding="w3cdtf">2012-03-21</dateValid>
<edition>Kühl S, Zürcher S, Mahid T, Müller-Gerbl M, Filippi A, Cattin P. Accuracy of full guided vs. half-guided implant surgery. Clin. Oral Impl. Res. 24, 2013, 763–769</edition>
<copyrightDate encoding="w3cdtf">2013</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<abstract>The benefit in terms of higher accuracy for full guided implant surgery (template based guided cavity preparation and guided implant insertion) compared with half‐guided surgery (template based guided cavity preparation and free‐handed, manual implant insertion) has not been proved till now.</abstract>
<abstract>A total of 38 identical implants were inserted into five human cadaver jaws, after virtual implant planning with the coDiagnostiX™ device. All cavities were drilled using templates equipped with tubes for guidance. At random, 19 implants were inserted in a free handed way (half‐guided), whereas 19 implants were inserted in a guided way through the templates tubes (full guided). Postoperative cone beam computer tomographies (CBCT) were performed, and based on image fusion the total deviations between the virtual implant positions at the implants base and tip were determined and compared between both implantation modi.</abstract>
<abstract>The mean difference in accuracy between both implantation modalities at the implants bases was 0.72 mm (range: 0.16–1.17 mm, SD: 0.45). The mean difference in accuracy between both modalities at the implants tips was 0.46 mm (range: 0.16–1.23 mm. SD: 0.49). Although full guided implantation showed a generally higher accuracy (mean tip: 1.54 mm, range: 0.33–3.64 mm; mean base: 1.52 mm, range: 0.4–3.54 mm) than half‐guided implantation (mean tip: 1.84 mm, range: 0.84–3.22 mm; mean base: 1.56 mm, range: 0.49–3.43 mm), the differences were not statistically significant.</abstract>
<abstract>The accuracy of half‐guided implant surgery is comparable with full guided implant surgery.</abstract>
<subject>
<genre>keywords</genre>
<topic>dental implants</topic>
<topic>guidance</topic>
<topic>templates</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>Clinical Oral Implants Research</title>
</titleInfo>
<titleInfo type="abbreviated">
<title>Clin. Oral. Implants. Res.</title>
</titleInfo>
<genre type="journal" authority="ISTEX" authorityURI="https://publication-type.data.istex.fr" valueURI="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</genre>
<subject>
<genre>article-category</genre>
<topic>Original Research Article</topic>
</subject>
<identifier type="ISSN">0905-7161</identifier>
<identifier type="eISSN">1600-0501</identifier>
<identifier type="DOI">10.1111/(ISSN)1600-0501</identifier>
<identifier type="PublisherID">CLR</identifier>
<part>
<date>2013</date>
<detail type="volume">
<caption>vol.</caption>
<number>24</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>7</number>
</detail>
<extent unit="pages">
<start>763</start>
<end>769</end>
<total>7</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">59AA222A8782BABBC4B2150A36F132307A9E3A82</identifier>
<identifier type="ark">ark:/67375/WNG-ZHRLSWSQ-L</identifier>
<identifier type="DOI">10.1111/j.1600-0501.2012.02484.x</identifier>
<identifier type="ArticleID">CLR2484</identifier>
<accessCondition type="use and reproduction" contentType="copyright">Copyright © 2013 John Wiley & Sons A/S© 2012 John Wiley & Sons A/S</accessCondition>
<recordInfo>
<recordContentSource authority="ISTEX" authorityURI="https://loaded-corpus.data.istex.fr" valueURI="https://loaded-corpus.data.istex.fr/ark:/67375/XBH-L0C46X92-X">wiley</recordContentSource>
</recordInfo>
</mods>
<json:item>
<extension>json</extension>
<original>false</original>
<mimetype>application/json</mimetype>
<uri>https://api.istex.fr/document/59AA222A8782BABBC4B2150A36F132307A9E3A82/metadata/json</uri>
</json:item>
</metadata>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000327 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 000327 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:59AA222A8782BABBC4B2150A36F132307A9E3A82
   |texte=   Accuracy of full guided vs. half‐guided implant surgery
}}

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020