Serveur d'exploration Covid (26 mars)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Nanotechnology for Detection of Small Mass Difference

Identifieur interne : 000744 ( Istex/Curation ); précédent : 000743; suivant : 000745

Nanotechnology for Detection of Small Mass Difference

Auteurs : S. V. Gupta [Inde]

Source :

RBID : ISTEX:4302C6656D8D8607B20F97B58274111A6307AC5F

Abstract

Abstract: Mostly, mass of a macroscopic object is determined by comparing the gravitational forces experienced by the object and the body of known mass. Relative uncertainty in 1kg is pretty small say one part in 109. However, gravitational force of an object of molecular scale is too feeble to detect. Hence, normal method of using a balance will not do for mass measurement on the microscopic scale. Measurement of mass at the microscopic scale is very vital as it serves powerful tool that can provide information about the molecular and atomic composition of an object, detection, prevention and treatment of various diseases. Mechanical balances with electronic devices can detect only up to 0.1μg. An alternate method to measure the mass of an object is to consider mass as quantification of inertia. This principle is used in mass spectroscopy. In this the trajectory of an ionised particle in a strong electromagnetic field provides a precise measure of the inertia of the particle and hence a measure of its mass. Mass spectroscopy is able to distinguish ionised particles that differ by a single atomic mass unit. One atomic mass unit is equal to 1.66 ×10−27kg. However, mass spectroscopy is restricted to ionised particles so it cannot be applied to all microscopic objects, which are neither in charged state nor can be charged. So for smaller masses, one has to depend upon certain other phenomenon.

Url:
DOI: 10.1007/978-3-642-23412-5_11

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:4302C6656D8D8607B20F97B58274111A6307AC5F

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Nanotechnology for Detection of Small Mass Difference</title>
<author>
<name sortKey="Gupta, S V" sort="Gupta, S V" uniqKey="Gupta S" first="S. V." last="Gupta">S. V. Gupta</name>
<affiliation wicri:level="1">
<mods:affiliation>Sector-8, Rohini 269/B-5, 110085, Delhi, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Sector-8, Rohini 269/B-5, 110085, Delhi</wicri:regionArea>
</affiliation>
<affiliation wicri:level="1">
<mods:affiliation>E-mail: satyavirji@yahoo.co.in</mods:affiliation>
<country wicri:rule="url">Inde</country>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:4302C6656D8D8607B20F97B58274111A6307AC5F</idno>
<date when="2012" year="2012">2012</date>
<idno type="doi">10.1007/978-3-642-23412-5_11</idno>
<idno type="url">https://api.istex.fr/ark:/67375/HCB-0DKC8X5F-K/fulltext.pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000777</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000777</idno>
<idno type="wicri:Area/Istex/Curation">000744</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Nanotechnology for Detection of Small Mass Difference</title>
<author>
<name sortKey="Gupta, S V" sort="Gupta, S V" uniqKey="Gupta S" first="S. V." last="Gupta">S. V. Gupta</name>
<affiliation wicri:level="1">
<mods:affiliation>Sector-8, Rohini 269/B-5, 110085, Delhi, India</mods:affiliation>
<country xml:lang="fr">Inde</country>
<wicri:regionArea>Sector-8, Rohini 269/B-5, 110085, Delhi</wicri:regionArea>
</affiliation>
<affiliation wicri:level="1">
<mods:affiliation>E-mail: satyavirji@yahoo.co.in</mods:affiliation>
<country wicri:rule="url">Inde</country>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="s" type="main" xml:lang="en">Springer Series in Materials Science</title>
<title level="s" type="abbrev">Springer Ser.Materials</title>
<idno type="ISSN">0933-033X</idno>
<idno type="eISSN">2196-2812</idno>
<idno type="ISSN">0933-033X</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0933-033X</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Abstract: Mostly, mass of a macroscopic object is determined by comparing the gravitational forces experienced by the object and the body of known mass. Relative uncertainty in 1kg is pretty small say one part in 109. However, gravitational force of an object of molecular scale is too feeble to detect. Hence, normal method of using a balance will not do for mass measurement on the microscopic scale. Measurement of mass at the microscopic scale is very vital as it serves powerful tool that can provide information about the molecular and atomic composition of an object, detection, prevention and treatment of various diseases. Mechanical balances with electronic devices can detect only up to 0.1μg. An alternate method to measure the mass of an object is to consider mass as quantification of inertia. This principle is used in mass spectroscopy. In this the trajectory of an ionised particle in a strong electromagnetic field provides a precise measure of the inertia of the particle and hence a measure of its mass. Mass spectroscopy is able to distinguish ionised particles that differ by a single atomic mass unit. One atomic mass unit is equal to 1.66 ×10−27kg. However, mass spectroscopy is restricted to ionised particles so it cannot be applied to all microscopic objects, which are neither in charged state nor can be charged. So for smaller masses, one has to depend upon certain other phenomenon.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/CovidV2/Data/Istex/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000744 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Curation/biblio.hfd -nk 000744 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    CovidV2
   |flux=    Istex
   |étape=   Curation
   |type=    RBID
   |clé=     ISTEX:4302C6656D8D8607B20F97B58274111A6307AC5F
   |texte=   Nanotechnology for Detection of Small Mass Difference
}}

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Sat Mar 28 17:51:24 2020. Site generation: Sun Jan 31 15:35:48 2021