Serveur d'exploration Covid

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes.

Identifieur interne : 000675 ( Main/Exploration ); précédent : 000674; suivant : 000676

An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes.

Auteurs : Laila Ali Layqah [Arabie saoudite] ; Shimaa Eissa [Arabie saoudite]

Source :

RBID : pubmed:30847572

Descripteurs français

English descriptors

Abstract

The Middle East respiratory syndrome corona virus (MERS-CoV) is highly pathogenic. An immunosensor for the determination of MERS-CoV is described here. It is based on a competitive assay carried out on an array of carbon electrodes (DEP) modified with gold nanoparticles. Recombinant spike protein S1 was used as a biomarker for MERS CoV. The electrode array enables multiplexed detection of different CoVs. The biosensor is based on indirect competition between free virus in the sample and immobilized MERS-CoV protein for a fixed concentration of antibody added to the sample. Voltammetric response is detected by monitoring the change in the peak current (typically acquired at a working potential of -0.05 V vs. Ag/AgCl) after addition of different concentrations of antigen against MERS-CoV. Electrochemical measurements using ferrocyanide/ferricyanide as a probe were recorded using square wave voltammetry (SWV). Good linear response between the sensor response and the concentrations from 0.001 to 100 ng.mL-1 and 0.01 to 10,000 ng.mL-1 were observed for MERS-CoV and HCoV, respectively. The assay was performed in 20 min with detection limit as low as 0.4 and 1.0 pg.mL-1 for HCoV and MERS-CoV, respectively. The method is highly selective over non-specific proteins such as Influenza A and B. The method is single-step, sensitive and accurate. It was successfully applied to spiked nasal samples. Graphical abstract An electrochemical immunoassay is described for the Middle East Respiratory Syndrome Corona Virus (MERS-CoV). The method is based on a competitive assay carried out on a carbon array electrodes (DEP) nanostructured with gold nanoparticles. The array electrodes enable the multiplexed detection of different types of Corona Virus.

DOI: 10.1007/s00604-019-3345-5
PubMed: 30847572


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes.</title>
<author>
<name sortKey="Layqah, Laila Ali" sort="Layqah, Laila Ali" uniqKey="Layqah L" first="Laila Ali" last="Layqah">Laila Ali Layqah</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Road, Riyadh, 11533, Saudi Arabia.</nlm:affiliation>
<country xml:lang="fr">Arabie saoudite</country>
<wicri:regionArea>Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Road, Riyadh, 11533</wicri:regionArea>
<wicri:noRegion>11533</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Eissa, Shimaa" sort="Eissa, Shimaa" uniqKey="Eissa S" first="Shimaa" last="Eissa">Shimaa Eissa</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Road, Riyadh, 11533, Saudi Arabia. seissa@alfaisal.edu.</nlm:affiliation>
<country xml:lang="fr">Arabie saoudite</country>
<wicri:regionArea>Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Road, Riyadh, 11533</wicri:regionArea>
<wicri:noRegion>11533</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2019">2019</date>
<idno type="RBID">pubmed:30847572</idno>
<idno type="pmid">30847572</idno>
<idno type="doi">10.1007/s00604-019-3345-5</idno>
<idno type="wicri:Area/PubMed/Corpus">000600</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000600</idno>
<idno type="wicri:Area/PubMed/Curation">000600</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000600</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000597</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000597</idno>
<idno type="wicri:Area/Ncbi/Merge">000757</idno>
<idno type="wicri:Area/Ncbi/Curation">000757</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000757</idno>
<idno type="wicri:Area/Main/Merge">000677</idno>
<idno type="wicri:Area/Main/Curation">000675</idno>
<idno type="wicri:Area/Main/Exploration">000675</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes.</title>
<author>
<name sortKey="Layqah, Laila Ali" sort="Layqah, Laila Ali" uniqKey="Layqah L" first="Laila Ali" last="Layqah">Laila Ali Layqah</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Road, Riyadh, 11533, Saudi Arabia.</nlm:affiliation>
<country xml:lang="fr">Arabie saoudite</country>
<wicri:regionArea>Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Road, Riyadh, 11533</wicri:regionArea>
<wicri:noRegion>11533</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Eissa, Shimaa" sort="Eissa, Shimaa" uniqKey="Eissa S" first="Shimaa" last="Eissa">Shimaa Eissa</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Road, Riyadh, 11533, Saudi Arabia. seissa@alfaisal.edu.</nlm:affiliation>
<country xml:lang="fr">Arabie saoudite</country>
<wicri:regionArea>Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Road, Riyadh, 11533</wicri:regionArea>
<wicri:noRegion>11533</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Mikrochimica acta</title>
<idno type="eISSN">1436-5073</idno>
<imprint>
<date when="2019" type="published">2019</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Antibodies, Viral (metabolism)</term>
<term>Biosensing Techniques (methods)</term>
<term>Coronavirus Infections (diagnosis)</term>
<term>Electrochemical Techniques (methods)</term>
<term>Electrodes</term>
<term>Ferrocyanides (chemistry)</term>
<term>Gold (chemistry)</term>
<term>Immunoassay (methods)</term>
<term>Limit of Detection</term>
<term>Metal Nanoparticles (chemistry)</term>
<term>Middle East Respiratory Syndrome Coronavirus (chemistry)</term>
<term>Oxidation-Reduction</term>
<term>Particle Size</term>
<term>Sensitivity and Specificity</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Anticorps antiviraux (métabolisme)</term>
<term>Coronavirus du syndrome respiratoire du Moyen-Orient ()</term>
<term>Dosage immunologique ()</term>
<term>Hexacyanoferrates II ()</term>
<term>Infections à coronavirus (diagnostic)</term>
<term>Limite de détection</term>
<term>Nanoparticules métalliques ()</term>
<term>Or ()</term>
<term>Oxydoréduction</term>
<term>Propriétés de surface</term>
<term>Sensibilité et spécificité</term>
<term>Taille de particule</term>
<term>Techniques de biocapteur ()</term>
<term>Techniques électrochimiques ()</term>
<term>Électrodes</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en">
<term>Ferrocyanides</term>
<term>Gold</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="metabolism" xml:lang="en">
<term>Antibodies, Viral</term>
</keywords>
<keywords scheme="MESH" qualifier="chemistry" xml:lang="en">
<term>Metal Nanoparticles</term>
<term>Middle East Respiratory Syndrome Coronavirus</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Coronavirus Infections</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic" xml:lang="fr">
<term>Infections à coronavirus</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Biosensing Techniques</term>
<term>Electrochemical Techniques</term>
<term>Immunoassay</term>
</keywords>
<keywords scheme="MESH" qualifier="métabolisme" xml:lang="fr">
<term>Anticorps antiviraux</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Electrodes</term>
<term>Limit of Detection</term>
<term>Oxidation-Reduction</term>
<term>Particle Size</term>
<term>Sensitivity and Specificity</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Coronavirus du syndrome respiratoire du Moyen-Orient</term>
<term>Dosage immunologique</term>
<term>Hexacyanoferrates II</term>
<term>Limite de détection</term>
<term>Nanoparticules métalliques</term>
<term>Or</term>
<term>Oxydoréduction</term>
<term>Propriétés de surface</term>
<term>Sensibilité et spécificité</term>
<term>Taille de particule</term>
<term>Techniques de biocapteur</term>
<term>Techniques électrochimiques</term>
<term>Électrodes</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The Middle East respiratory syndrome corona virus (MERS-CoV) is highly pathogenic. An immunosensor for the determination of MERS-CoV is described here. It is based on a competitive assay carried out on an array of carbon electrodes (DEP) modified with gold nanoparticles. Recombinant spike protein S1 was used as a biomarker for MERS CoV. The electrode array enables multiplexed detection of different CoVs. The biosensor is based on indirect competition between free virus in the sample and immobilized MERS-CoV protein for a fixed concentration of antibody added to the sample. Voltammetric response is detected by monitoring the change in the peak current (typically acquired at a working potential of -0.05 V vs. Ag/AgCl) after addition of different concentrations of antigen against MERS-CoV. Electrochemical measurements using ferrocyanide/ferricyanide as a probe were recorded using square wave voltammetry (SWV). Good linear response between the sensor response and the concentrations from 0.001 to 100 ng.mL
<sup>-1</sup>
and 0.01 to 10,000 ng.mL
<sup>-1</sup>
were observed for MERS-CoV and HCoV, respectively. The assay was performed in 20 min with detection limit as low as 0.4 and 1.0 pg.mL
<sup>-1</sup>
for HCoV and MERS-CoV, respectively. The method is highly selective over non-specific proteins such as Influenza A and B. The method is single-step, sensitive and accurate. It was successfully applied to spiked nasal samples. Graphical abstract An electrochemical immunoassay is described for the Middle East Respiratory Syndrome Corona Virus (MERS-CoV). The method is based on a competitive assay carried out on a carbon array electrodes (DEP) nanostructured with gold nanoparticles. The array electrodes enable the multiplexed detection of different types of Corona Virus.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Arabie saoudite</li>
</country>
</list>
<tree>
<country name="Arabie saoudite">
<noRegion>
<name sortKey="Layqah, Laila Ali" sort="Layqah, Laila Ali" uniqKey="Layqah L" first="Laila Ali" last="Layqah">Laila Ali Layqah</name>
</noRegion>
<name sortKey="Eissa, Shimaa" sort="Eissa, Shimaa" uniqKey="Eissa S" first="Shimaa" last="Eissa">Shimaa Eissa</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/CovidV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000675 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000675 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    CovidV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:30847572
   |texte=   An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:30847572" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a CovidV1 

Wicri

This area was generated with Dilib version V0.6.33.