Serveur d'exploration Xenakis

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Complications in high tibial (medial opening wedge) osteotomy

Identifieur interne : 000386 ( Main/Exploration ); précédent : 000385; suivant : 000387

Complications in high tibial (medial opening wedge) osteotomy

Auteurs : Gunter Spahn [Allemagne]

Source :

RBID : ISTEX:FB825ACCA57DCA7E5F75BBF8B98506ABC8F752BF

English descriptors

Abstract

Abstract: Introduction: The high tibial (medial opening wedge) osteotomy (HTO) is a standard procedure in the treatment of varus gonarthrosis. This is potentially associated with various complications. The aim of this study was an analysis of complications and potential technical mistakes. Materials and methods: A total of 85 patients (49 male and 36 female) suffering from varus gonarthrosis underwent a medial opening wedge HTO. The osteotomy was fixed in 55 patients by a spacer plate (Puddu plate; group A). In group B (n=30), the osteotomies were fixed by C-plate. Results: The rate of complications was 43.6% in group A and 16.7% in group B (p<0.05). Infraction of the lateral tibial head is a possible intraoperative complication. This was seen in 11.7%. An additional osteosynthesis was required in group A. In contrast, the C-plate can solve this problem without additional measures. General complications of the HTO were seen: infection (4.7%), hematoma (4.7%), and thrombosis (2.3%). In every case of a severe deep infection, the osteotomy space was filled with synthetic bone graft. These grafts were used only in group A. Failure of the implants is a potential cause of loss of correction. This complication was seen nine times in group A but never in group B. Conclusion: A diligent surgical technique and a convenient implant are obligatory in (medial opening wedge) HTO.

Url:
DOI: 10.1007/s00402-003-0588-7


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Complications in high tibial (medial opening wedge) osteotomy</title>
<author>
<name sortKey="Spahn, Gunter" sort="Spahn, Gunter" uniqKey="Spahn G" first="Gunter" last="Spahn">Gunter Spahn</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:FB825ACCA57DCA7E5F75BBF8B98506ABC8F752BF</idno>
<date when="2003" year="2003">2003</date>
<idno type="doi">10.1007/s00402-003-0588-7</idno>
<idno type="url">https://api.istex.fr/document/FB825ACCA57DCA7E5F75BBF8B98506ABC8F752BF/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000322</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000322</idno>
<idno type="wicri:Area/Istex/Curation">000322</idno>
<idno type="wicri:Area/Istex/Checkpoint">000295</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000295</idno>
<idno type="wicri:doubleKey">0936-8051:2003:Spahn G:complications:in:high</idno>
<idno type="wicri:Area/Main/Merge">000388</idno>
<idno type="wicri:Area/Main/Curation">000386</idno>
<idno type="wicri:Area/Main/Exploration">000386</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Complications in high tibial (medial opening wedge) osteotomy</title>
<author>
<name sortKey="Spahn, Gunter" sort="Spahn, Gunter" uniqKey="Spahn G" first="Gunter" last="Spahn">Gunter Spahn</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Clinic of Arthroscopy and Joint Surgery Eisenach, Sophienstraße 16, 99817, Eisenach</wicri:regionArea>
<wicri:noRegion>99817, Eisenach</wicri:noRegion>
<wicri:noRegion>Eisenach</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1">
<country wicri:rule="url">Allemagne</country>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Archives of Orthopaedic and Trauma Surgery</title>
<title level="j" type="abbrev">Arch Orthop Trauma Surg</title>
<idno type="ISSN">0936-8051</idno>
<idno type="eISSN">1434-3916</idno>
<imprint>
<publisher>Springer-Verlag</publisher>
<pubPlace>Berlin/Heidelberg</pubPlace>
<date type="published" when="2004-12-01">2004-12-01</date>
<biblScope unit="volume">124</biblScope>
<biblScope unit="issue">10</biblScope>
<biblScope unit="page" from="649">649</biblScope>
<biblScope unit="page" to="653">653</biblScope>
</imprint>
<idno type="ISSN">0936-8051</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0936-8051</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Complications</term>
<term>Gonarthrosis</term>
<term>Implants</term>
<term>Tibial osteotomy</term>
<term>Varus</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Abstract: Introduction: The high tibial (medial opening wedge) osteotomy (HTO) is a standard procedure in the treatment of varus gonarthrosis. This is potentially associated with various complications. The aim of this study was an analysis of complications and potential technical mistakes. Materials and methods: A total of 85 patients (49 male and 36 female) suffering from varus gonarthrosis underwent a medial opening wedge HTO. The osteotomy was fixed in 55 patients by a spacer plate (Puddu plate; group A). In group B (n=30), the osteotomies were fixed by C-plate. Results: The rate of complications was 43.6% in group A and 16.7% in group B (p<0.05). Infraction of the lateral tibial head is a possible intraoperative complication. This was seen in 11.7%. An additional osteosynthesis was required in group A. In contrast, the C-plate can solve this problem without additional measures. General complications of the HTO were seen: infection (4.7%), hematoma (4.7%), and thrombosis (2.3%). In every case of a severe deep infection, the osteotomy space was filled with synthetic bone graft. These grafts were used only in group A. Failure of the implants is a potential cause of loss of correction. This complication was seen nine times in group A but never in group B. Conclusion: A diligent surgical technique and a convenient implant are obligatory in (medial opening wedge) HTO.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Allemagne</li>
</country>
</list>
<tree>
<country name="Allemagne">
<noRegion>
<name sortKey="Spahn, Gunter" sort="Spahn, Gunter" uniqKey="Spahn G" first="Gunter" last="Spahn">Gunter Spahn</name>
</noRegion>
<name sortKey="Spahn, Gunter" sort="Spahn, Gunter" uniqKey="Spahn G" first="Gunter" last="Spahn">Gunter Spahn</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/XenakisV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000386 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000386 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    XenakisV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:FB825ACCA57DCA7E5F75BBF8B98506ABC8F752BF
   |texte=   Complications in high tibial (medial opening wedge) osteotomy
}}

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Thu Nov 8 16:12:13 2018. Site generation: Wed Mar 6 22:10:31 2024