The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: 'OPERA' (operational phantom for external radiotherapy audit).

Identifieur interne : 000612 ( PubMed/Curation ); précédent : 000611; suivant : 000613

The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: 'OPERA' (operational phantom for external radiotherapy audit).

Auteurs : Ans Swinnen [Belgique] ; Jan Verstraete ; Dominique Huyskens

Source :

RBID : pubmed:12242120

English descriptors

Abstract

This study presents a technical description of the solid multipurpose phantom (MPP) 'OPERA' (operational phantom for external radiotherapy audit) for mailed dosimetry checks of photon beams in reference and non-reference conditions. The aim is to test the functionality of this phantom by comparing the results provided by the local treatment planning system (TPS) with the measurements by film and thermoluminescence dosimeters (TLDs) in a number of clinical conditions.

PubMed: 12242120

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:12242120

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: 'OPERA' (operational phantom for external radiotherapy audit).</title>
<author>
<name sortKey="Swinnen, Ans" sort="Swinnen, Ans" uniqKey="Swinnen A" first="Ans" last="Swinnen">Ans Swinnen</name>
<affiliation wicri:level="1">
<nlm:affiliation>Division of Radiation Physics, Department of Oncology, University Hospital Gasthuisberg, Herestraat 49, 3000 Leuven, Belgium.</nlm:affiliation>
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Division of Radiation Physics, Department of Oncology, University Hospital Gasthuisberg, Herestraat 49, 3000 Leuven</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Verstraete, Jan" sort="Verstraete, Jan" uniqKey="Verstraete J" first="Jan" last="Verstraete">Jan Verstraete</name>
</author>
<author>
<name sortKey="Huyskens, Dominique" sort="Huyskens, Dominique" uniqKey="Huyskens D" first="Dominique" last="Huyskens">Dominique Huyskens</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2002">2002</date>
<idno type="RBID">pubmed:12242120</idno>
<idno type="pmid">12242120</idno>
<idno type="wicri:Area/PubMed/Corpus">000612</idno>
<idno type="wicri:Area/PubMed/Curation">000612</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: 'OPERA' (operational phantom for external radiotherapy audit).</title>
<author>
<name sortKey="Swinnen, Ans" sort="Swinnen, Ans" uniqKey="Swinnen A" first="Ans" last="Swinnen">Ans Swinnen</name>
<affiliation wicri:level="1">
<nlm:affiliation>Division of Radiation Physics, Department of Oncology, University Hospital Gasthuisberg, Herestraat 49, 3000 Leuven, Belgium.</nlm:affiliation>
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Division of Radiation Physics, Department of Oncology, University Hospital Gasthuisberg, Herestraat 49, 3000 Leuven</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Verstraete, Jan" sort="Verstraete, Jan" uniqKey="Verstraete J" first="Jan" last="Verstraete">Jan Verstraete</name>
</author>
<author>
<name sortKey="Huyskens, Dominique" sort="Huyskens, Dominique" uniqKey="Huyskens D" first="Dominique" last="Huyskens">Dominique Huyskens</name>
</author>
</analytic>
<series>
<title level="j">Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology</title>
<idno type="ISSN">0167-8140</idno>
<imprint>
<date when="2002" type="published">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Film Dosimetry</term>
<term>Humans</term>
<term>Medical Audit</term>
<term>Phantoms, Imaging</term>
<term>Photons</term>
<term>Radiometry</term>
<term>Radiotherapy</term>
<term>Radiotherapy Dosage</term>
<term>Thermoluminescent Dosimetry</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Film Dosimetry</term>
<term>Humans</term>
<term>Medical Audit</term>
<term>Phantoms, Imaging</term>
<term>Photons</term>
<term>Radiometry</term>
<term>Radiotherapy</term>
<term>Radiotherapy Dosage</term>
<term>Thermoluminescent Dosimetry</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This study presents a technical description of the solid multipurpose phantom (MPP) 'OPERA' (operational phantom for external radiotherapy audit) for mailed dosimetry checks of photon beams in reference and non-reference conditions. The aim is to test the functionality of this phantom by comparing the results provided by the local treatment planning system (TPS) with the measurements by film and thermoluminescence dosimeters (TLDs) in a number of clinical conditions.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">12242120</PMID>
<DateCreated>
<Year>2002</Year>
<Month>09</Month>
<Day>20</Day>
</DateCreated>
<DateCompleted>
<Year>2003</Year>
<Month>03</Month>
<Day>10</Day>
</DateCompleted>
<DateRevised>
<Year>2010</Year>
<Month>03</Month>
<Day>23</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0167-8140</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>64</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2002</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology</Title>
<ISOAbbreviation>Radiother Oncol</ISOAbbreviation>
</Journal>
<ArticleTitle>The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: 'OPERA' (operational phantom for external radiotherapy audit).</ArticleTitle>
<Pagination>
<MedlinePgn>317-26</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND AND PURPOSE" NlmCategory="OBJECTIVE">This study presents a technical description of the solid multipurpose phantom (MPP) 'OPERA' (operational phantom for external radiotherapy audit) for mailed dosimetry checks of photon beams in reference and non-reference conditions. The aim is to test the functionality of this phantom by comparing the results provided by the local treatment planning system (TPS) with the measurements by film and thermoluminescence dosimeters (TLDs) in a number of clinical conditions.</AbstractText>
<AbstractText Label="MATERIAL AND METHODS" NlmCategory="METHODS">The polystyrene MPP is constructed to check the following five irradiation conditions: square fields, asymmetrical fields, wedged beams, oblique incidence and influence of inhomogeneities in the field. The absorbed dose on the central beam axis is measured with TLDs for the first three irradiation conditions and the relative dose distributions are verified with film.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The 'OPERA' phantom and the corresponding instruction sheets were mailed to radiotherapy centres of 12 different countries, in order to verify its functionality. A good agreement between TPS and the film data is found: the mean deviations between relative dose profiles obtained from film and locally applied TPS data range between -1.2 and 0.4%, except for the short side of the asymmetrical field. The standard deviations (SDs) generally increase off-axis, with a large SD on the asymmetrical side. Considering the TLD results, a mean ratio of measured to stated dose of 0.995+/-0.014 (1 SD), 0.988+/-0.019 (1 SD) and 0.981+/-0.024 (1 SD) for set-up 1 (square field), 2 (asymmetrical field) and 3 (wedged field), respectively, has been found.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">The 'OPERA' phantom can be useful for on- and off-axis verification of the TPS, as well as for mailed dosimetrical checks of photon beams in reference and non-reference conditions.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Swinnen</LastName>
<ForeName>Ans</ForeName>
<Initials>A</Initials>
<AffiliationInfo>
<Affiliation>Division of Radiation Physics, Department of Oncology, University Hospital Gasthuisberg, Herestraat 49, 3000 Leuven, Belgium.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Verstraete</LastName>
<ForeName>Jan</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Huyskens</LastName>
<ForeName>Dominique</ForeName>
<Initials>D</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Ireland</Country>
<MedlineTA>Radiother Oncol</MedlineTA>
<NlmUniqueID>8407192</NlmUniqueID>
<ISSNLinking>0167-8140</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D005373">Film Dosimetry</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D008485">Medical Audit</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D019047">Phantoms, Imaging</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D017785">Photons</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011874">Radiometry</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011878">Radiotherapy</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011879">Radiotherapy Dosage</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013819">Thermoluminescent Dosimetry</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2002</Year>
<Month>9</Month>
<Day>21</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2003</Year>
<Month>3</Month>
<Day>11</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2002</Year>
<Month>9</Month>
<Day>21</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">12242120</ArticleId>
<ArticleId IdType="pii">S016781400200186X</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/OperaV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000612 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000612 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    OperaV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:12242120
   |texte=   The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: 'OPERA' (operational phantom for external radiotherapy audit).
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:12242120" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a OperaV1 

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu Apr 14 14:59:05 2016. Site generation: Thu Jan 4 23:09:23 2024