Serveur d'exploration sur l'opéra

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A scale value for the balance inside a historical opera house.

Identifieur interne : 000529 ( PubMed/Curation ); précédent : 000528; suivant : 000530

A scale value for the balance inside a historical opera house.

Auteurs : Nicola Prodi [Italie] ; Sylvia Velecka

Source :

RBID : pubmed:15759697

Abstract

In the framework of opera house acoustics, the term "balance" refers to the acoustical competition between the singer on the stage and the orchestra in the pit. The mechanism allowing the operatic singers to be heard over the orchestra has to do with their skill in enhancing the vocal emission by a peculiar use of the formant frequencies. This vital factor is sensed by the listeners and, apart from the obvious sound power ratio of the stage and the pit sources, is the main cue that helps to formulate a subjective impression of the balance. To achieve its objective qualification, two calibrated sound sources can be placed on the stage and in the pit, respectively, and their sound level difference is measured at the listeners' seats. The scope of this work is to investigate the relationship between the subjective impression and the objective indicator of the balance and to develop a scale value for the parameter in the case of a historical opera house. For this scope a set of acoustical data from the Teatro Comunale in Ferrara will be used to create synthetic sound fields with controlled conditions of the balance between the stage and the pit. This methodology employs an anechoic piece for soprano (with piano accompaniment) and is implemented in a dead room equipped with an acoustical rendering system. The sound fields are used to investigate the appropriate balance values by means of listening tests. The results of the scaling exercise show that a suitable range of values can be extracted and that the sound from the stage and the pit is perceived as balanced when the loudness difference between the two is comprised within -2.0 dBA and +2.3 dBA.

PubMed: 15759697

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:15759697

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A scale value for the balance inside a historical opera house.</title>
<author>
<name sortKey="Prodi, Nicola" sort="Prodi, Nicola" uniqKey="Prodi N" first="Nicola" last="Prodi">Nicola Prodi</name>
<affiliation wicri:level="1">
<nlm:affiliation>Dipartimento di Ingegneria, Università degli Studi di Ferrara, 44100 Ferrara, Italia. prodi@ing.unife.it</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Dipartimento di Ingegneria, Università degli Studi di Ferrara, 44100 Ferrara</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Velecka, Sylvia" sort="Velecka, Sylvia" uniqKey="Velecka S" first="Sylvia" last="Velecka">Sylvia Velecka</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2005">2005</date>
<idno type="RBID">pubmed:15759697</idno>
<idno type="pmid">15759697</idno>
<idno type="wicri:Area/PubMed/Corpus">000529</idno>
<idno type="wicri:Area/PubMed/Curation">000529</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A scale value for the balance inside a historical opera house.</title>
<author>
<name sortKey="Prodi, Nicola" sort="Prodi, Nicola" uniqKey="Prodi N" first="Nicola" last="Prodi">Nicola Prodi</name>
<affiliation wicri:level="1">
<nlm:affiliation>Dipartimento di Ingegneria, Università degli Studi di Ferrara, 44100 Ferrara, Italia. prodi@ing.unife.it</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Dipartimento di Ingegneria, Università degli Studi di Ferrara, 44100 Ferrara</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Velecka, Sylvia" sort="Velecka, Sylvia" uniqKey="Velecka S" first="Sylvia" last="Velecka">Sylvia Velecka</name>
</author>
</analytic>
<series>
<title level="j">The Journal of the Acoustical Society of America</title>
<idno type="ISSN">0001-4966</idno>
<imprint>
<date when="2005" type="published">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">In the framework of opera house acoustics, the term "balance" refers to the acoustical competition between the singer on the stage and the orchestra in the pit. The mechanism allowing the operatic singers to be heard over the orchestra has to do with their skill in enhancing the vocal emission by a peculiar use of the formant frequencies. This vital factor is sensed by the listeners and, apart from the obvious sound power ratio of the stage and the pit sources, is the main cue that helps to formulate a subjective impression of the balance. To achieve its objective qualification, two calibrated sound sources can be placed on the stage and in the pit, respectively, and their sound level difference is measured at the listeners' seats. The scope of this work is to investigate the relationship between the subjective impression and the objective indicator of the balance and to develop a scale value for the parameter in the case of a historical opera house. For this scope a set of acoustical data from the Teatro Comunale in Ferrara will be used to create synthetic sound fields with controlled conditions of the balance between the stage and the pit. This methodology employs an anechoic piece for soprano (with piano accompaniment) and is implemented in a dead room equipped with an acoustical rendering system. The sound fields are used to investigate the appropriate balance values by means of listening tests. The results of the scaling exercise show that a suitable range of values can be extracted and that the sound from the stage and the pit is perceived as balanced when the loudness difference between the two is comprised within -2.0 dBA and +2.3 dBA.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE">
<PMID Version="1">15759697</PMID>
<DateCreated>
<Year>2005</Year>
<Month>03</Month>
<Day>11</Day>
</DateCreated>
<DateCompleted>
<Year>2005</Year>
<Month>07</Month>
<Day>25</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>12</Month>
<Day>27</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0001-4966</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>117</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2005</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>The Journal of the Acoustical Society of America</Title>
<ISOAbbreviation>J. Acoust. Soc. Am.</ISOAbbreviation>
</Journal>
<ArticleTitle>A scale value for the balance inside a historical opera house.</ArticleTitle>
<Pagination>
<MedlinePgn>771-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>In the framework of opera house acoustics, the term "balance" refers to the acoustical competition between the singer on the stage and the orchestra in the pit. The mechanism allowing the operatic singers to be heard over the orchestra has to do with their skill in enhancing the vocal emission by a peculiar use of the formant frequencies. This vital factor is sensed by the listeners and, apart from the obvious sound power ratio of the stage and the pit sources, is the main cue that helps to formulate a subjective impression of the balance. To achieve its objective qualification, two calibrated sound sources can be placed on the stage and in the pit, respectively, and their sound level difference is measured at the listeners' seats. The scope of this work is to investigate the relationship between the subjective impression and the objective indicator of the balance and to develop a scale value for the parameter in the case of a historical opera house. For this scope a set of acoustical data from the Teatro Comunale in Ferrara will be used to create synthetic sound fields with controlled conditions of the balance between the stage and the pit. This methodology employs an anechoic piece for soprano (with piano accompaniment) and is implemented in a dead room equipped with an acoustical rendering system. The sound fields are used to investigate the appropriate balance values by means of listening tests. The results of the scaling exercise show that a suitable range of values can be extracted and that the sound from the stage and the pit is perceived as balanced when the loudness difference between the two is comprised within -2.0 dBA and +2.3 dBA.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Prodi</LastName>
<ForeName>Nicola</ForeName>
<Initials>N</Initials>
<AffiliationInfo>
<Affiliation>Dipartimento di Ingegneria, Università degli Studi di Ferrara, 44100 Ferrara, Italia. prodi@ing.unife.it</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Velecka</LastName>
<ForeName>Sylvia</ForeName>
<Initials>S</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Acoust Soc Am</MedlineTA>
<NlmUniqueID>7503051</NlmUniqueID>
<ISSNLinking>0001-4966</ISSNLinking>
</MedlineJournalInfo>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2005</Year>
<Month>3</Month>
<Day>12</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2005</Year>
<Month>3</Month>
<Day>12</Day>
<Hour>9</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2005</Year>
<Month>3</Month>
<Day>12</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">15759697</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/OperaV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000529 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000529 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    OperaV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:15759697
   |texte=   A scale value for the balance inside a historical opera house.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:15759697" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a OperaV1 

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu Apr 14 14:59:05 2016. Site generation: Thu Jan 4 23:09:23 2024