Improvement of extraction system geometry with suppression of possible Penning discharge ignition.
Identifieur interne : 000164 ( PubMed/Checkpoint ); précédent : 000163; suivant : 000165Improvement of extraction system geometry with suppression of possible Penning discharge ignition.
Auteurs : O. Delferrière [France] ; R. Gobin [France] ; F. Harrault [France] ; S. Nyckees [France] ; O. Tuske [France]Source :
- The Review of scientific instruments ; 2014.
Abstract
During the past two years, a new ECR 2.45 GHz type ion source has been developed especially dedicated to intense light ion injector project like IPHI (Injecteur Proton Haute Intensité), IFMIF (International Fusion Materials Irradiation Facility), to reduce beam emittance at RFQ entrance by shortening the length of the LEBT. This new ALISES concept (Advanced Light Ion Source Extraction System) is based on the use of an additional LEBT short length solenoid very close to the extraction aperture. The fringe field of this new solenoid produces the needed magnetic field to create the ECR resonance in the plasma chamber. Such geometry allows first putting the solenoid at ground potential, while saving space in front of the extraction to move the first LEBT solenoid closer and focus earlier the intense extracted beam. During the commissioning of the source in 2011-2012, ALISES has produced about 20 mA extracted from a 6 mm diameter plasma extraction hole at 23 kV. But the magnetic configuration combined to the new extraction system geometry led to important Penning discharge conditions in the accelerator column. Lots of them have been eliminated by inserting glass pieces between electrodes to modify equipotential lines with unfavorable ExB vacuum zones where particles were produced and trapped. To study Penning discharge location, several 3D calculations have been performed with OPERA-3D/TOSCA code to simulate the possible production and trapping of electrons in the extraction system. The results obtained on different sources already built have shown very good agreement with sparks location observed experimentally on electrodes. The simulations results as well as experimental measurements are presented and solutions to prevent possible Penning discharge in future source geometries are established.
DOI: 10.1063/1.4830361
PubMed: 24593518
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
pubmed:24593518Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Improvement of extraction system geometry with suppression of possible Penning discharge ignition.</title>
<author><name sortKey="Delferriere, O" sort="Delferriere, O" uniqKey="Delferriere O" first="O" last="Delferrière">O. Delferrière</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Gobin, R" sort="Gobin, R" uniqKey="Gobin R" first="R" last="Gobin">R. Gobin</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Harrault, F" sort="Harrault, F" uniqKey="Harrault F" first="F" last="Harrault">F. Harrault</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Nyckees, S" sort="Nyckees, S" uniqKey="Nyckees S" first="S" last="Nyckees">S. Nyckees</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Tuske, O" sort="Tuske, O" uniqKey="Tuske O" first="O" last="Tuske">O. Tuske</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="doi">10.1063/1.4830361</idno>
<idno type="RBID">pubmed:24593518</idno>
<idno type="pmid">24593518</idno>
<idno type="wicri:Area/PubMed/Corpus">000174</idno>
<idno type="wicri:Area/PubMed/Curation">000174</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000164</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Improvement of extraction system geometry with suppression of possible Penning discharge ignition.</title>
<author><name sortKey="Delferriere, O" sort="Delferriere, O" uniqKey="Delferriere O" first="O" last="Delferrière">O. Delferrière</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Gobin, R" sort="Gobin, R" uniqKey="Gobin R" first="R" last="Gobin">R. Gobin</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Harrault, F" sort="Harrault, F" uniqKey="Harrault F" first="F" last="Harrault">F. Harrault</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Nyckees, S" sort="Nyckees, S" uniqKey="Nyckees S" first="S" last="Nyckees">S. Nyckees</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Tuske, O" sort="Tuske, O" uniqKey="Tuske O" first="O" last="Tuske">O. Tuske</name>
<affiliation wicri:level="3"><nlm:affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette</wicri:regionArea>
<placeName><region type="region" nuts="2">Île-de-France</region>
</placeName>
</affiliation>
</author>
</analytic>
<series><title level="j">The Review of scientific instruments</title>
<idno type="e-ISSN">1089-7623</idno>
<imprint><date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">During the past two years, a new ECR 2.45 GHz type ion source has been developed especially dedicated to intense light ion injector project like IPHI (Injecteur Proton Haute Intensité), IFMIF (International Fusion Materials Irradiation Facility), to reduce beam emittance at RFQ entrance by shortening the length of the LEBT. This new ALISES concept (Advanced Light Ion Source Extraction System) is based on the use of an additional LEBT short length solenoid very close to the extraction aperture. The fringe field of this new solenoid produces the needed magnetic field to create the ECR resonance in the plasma chamber. Such geometry allows first putting the solenoid at ground potential, while saving space in front of the extraction to move the first LEBT solenoid closer and focus earlier the intense extracted beam. During the commissioning of the source in 2011-2012, ALISES has produced about 20 mA extracted from a 6 mm diameter plasma extraction hole at 23 kV. But the magnetic configuration combined to the new extraction system geometry led to important Penning discharge conditions in the accelerator column. Lots of them have been eliminated by inserting glass pieces between electrodes to modify equipotential lines with unfavorable ExB vacuum zones where particles were produced and trapped. To study Penning discharge location, several 3D calculations have been performed with OPERA-3D/TOSCA code to simulate the possible production and trapping of electrons in the extraction system. The results obtained on different sources already built have shown very good agreement with sparks location observed experimentally on electrodes. The simulations results as well as experimental measurements are presented and solutions to prevent possible Penning discharge in future source geometries are established.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE"><PMID Version="1">24593518</PMID>
<DateCreated><Year>2014</Year>
<Month>03</Month>
<Day>05</Day>
</DateCreated>
<DateCompleted><Year>2014</Year>
<Month>10</Month>
<Day>30</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Electronic">1089-7623</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>85</Volume>
<Issue>2</Issue>
<PubDate><Year>2014</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>The Review of scientific instruments</Title>
<ISOAbbreviation>Rev Sci Instrum</ISOAbbreviation>
</Journal>
<ArticleTitle>Improvement of extraction system geometry with suppression of possible Penning discharge ignition.</ArticleTitle>
<Pagination><MedlinePgn>02A939</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1063/1.4830361</ELocationID>
<Abstract><AbstractText>During the past two years, a new ECR 2.45 GHz type ion source has been developed especially dedicated to intense light ion injector project like IPHI (Injecteur Proton Haute Intensité), IFMIF (International Fusion Materials Irradiation Facility), to reduce beam emittance at RFQ entrance by shortening the length of the LEBT. This new ALISES concept (Advanced Light Ion Source Extraction System) is based on the use of an additional LEBT short length solenoid very close to the extraction aperture. The fringe field of this new solenoid produces the needed magnetic field to create the ECR resonance in the plasma chamber. Such geometry allows first putting the solenoid at ground potential, while saving space in front of the extraction to move the first LEBT solenoid closer and focus earlier the intense extracted beam. During the commissioning of the source in 2011-2012, ALISES has produced about 20 mA extracted from a 6 mm diameter plasma extraction hole at 23 kV. But the magnetic configuration combined to the new extraction system geometry led to important Penning discharge conditions in the accelerator column. Lots of them have been eliminated by inserting glass pieces between electrodes to modify equipotential lines with unfavorable ExB vacuum zones where particles were produced and trapped. To study Penning discharge location, several 3D calculations have been performed with OPERA-3D/TOSCA code to simulate the possible production and trapping of electrons in the extraction system. The results obtained on different sources already built have shown very good agreement with sparks location observed experimentally on electrodes. The simulations results as well as experimental measurements are presented and solutions to prevent possible Penning discharge in future source geometries are established.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Delferrière</LastName>
<ForeName>O</ForeName>
<Initials>O</Initials>
<AffiliationInfo><Affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Gobin</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
<AffiliationInfo><Affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Harrault</LastName>
<ForeName>F</ForeName>
<Initials>F</Initials>
<AffiliationInfo><Affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Nyckees</LastName>
<ForeName>S</ForeName>
<Initials>S</Initials>
<AffiliationInfo><Affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Tuske</LastName>
<ForeName>O</ForeName>
<Initials>O</Initials>
<AffiliationInfo><Affiliation>Commissariat à l'Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191-Gif/Yvette, France.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Rev Sci Instrum</MedlineTA>
<NlmUniqueID>0405571</NlmUniqueID>
<ISSNLinking>0034-6748</ISSNLinking>
</MedlineJournalInfo>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2014</Year>
<Month>3</Month>
<Day>6</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2014</Year>
<Month>3</Month>
<Day>7</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2014</Year>
<Month>3</Month>
<Day>7</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="doi">10.1063/1.4830361</ArticleId>
<ArticleId IdType="pubmed">24593518</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations><list><country><li>France</li>
</country>
<region><li>Île-de-France</li>
</region>
</list>
<tree><country name="France"><region name="Île-de-France"><name sortKey="Delferriere, O" sort="Delferriere, O" uniqKey="Delferriere O" first="O" last="Delferrière">O. Delferrière</name>
</region>
<name sortKey="Gobin, R" sort="Gobin, R" uniqKey="Gobin R" first="R" last="Gobin">R. Gobin</name>
<name sortKey="Harrault, F" sort="Harrault, F" uniqKey="Harrault F" first="F" last="Harrault">F. Harrault</name>
<name sortKey="Nyckees, S" sort="Nyckees, S" uniqKey="Nyckees S" first="S" last="Nyckees">S. Nyckees</name>
<name sortKey="Tuske, O" sort="Tuske, O" uniqKey="Tuske O" first="O" last="Tuske">O. Tuske</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/OperaV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000164 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000164 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Musique |area= OperaV1 |flux= PubMed |étape= Checkpoint |type= RBID |clé= pubmed:24593518 |texte= Improvement of extraction system geometry with suppression of possible Penning discharge ignition. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i -Sk "pubmed:24593518" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd \ | NlmPubMed2Wicri -a OperaV1
This area was generated with Dilib version V0.6.21. |