Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement

Identifieur interne : 000336 ( PascalFrancis/Checkpoint ); précédent : 000335; suivant : 000337

Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement

Auteurs : Takayuki Hidaka [Japon]

Source :

RBID : Pascal:05-0264873

Descripteurs français

English descriptors

Abstract

Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C80, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

Pascal:05-0264873

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement</title>
<author>
<name sortKey="Hidaka, Takayuki" sort="Hidaka, Takayuki" uniqKey="Hidaka T" first="Takayuki" last="Hidaka">Takayuki Hidaka</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Takenaka R&D Institute, 1-5-1</s1>
<s2>Otsuka, Inzai, 270-1395</s2>
<s3>JPN</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>Japon</country>
<wicri:noRegion>Otsuka, Inzai, 270-1395</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">05-0264873</idno>
<date when="2005">2005</date>
<idno type="stanalyst">PASCAL 05-0264873 INIST</idno>
<idno type="RBID">Pascal:05-0264873</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000398</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000205</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000336</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement</title>
<author>
<name sortKey="Hidaka, Takayuki" sort="Hidaka, Takayuki" uniqKey="Hidaka T" first="Takayuki" last="Hidaka">Takayuki Hidaka</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Takenaka R&D Institute, 1-5-1</s1>
<s2>Otsuka, Inzai, 270-1395</s2>
<s3>JPN</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>Japon</country>
<wicri:noRegion>Otsuka, Inzai, 270-1395</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Acoustical science and technology</title>
<title level="j" type="abbreviated">Acoust. sci. technol.</title>
<idno type="ISSN">1346-3969</idno>
<imprint>
<date when="2005">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Acoustical science and technology</title>
<title level="j" type="abbreviated">Acoust. sci. technol.</title>
<idno type="ISSN">1346-3969</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acoustic reverberation</term>
<term>Binaural hearing</term>
<term>Concert hall</term>
<term>Cross correlation</term>
<term>Decay time</term>
<term>Interaural time</term>
<term>Localization</term>
<term>Musical acoustics</term>
<term>Objective analysis</term>
<term>Position measurement</term>
<term>Reverberation time</term>
<term>Room acoustics</term>
<term>Standards</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Acoustique salle</term>
<term>Acoustique musicale</term>
<term>Localisation</term>
<term>Réverbération acoustique</term>
<term>Audition binaurale</term>
<term>Norme</term>
<term>Salle concert</term>
<term>Temps descente</term>
<term>Temps interauriculaire</term>
<term>Temps réverbération</term>
<term>Corrélation croisée</term>
<term>Analyse objective</term>
<term>Mesure position</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Norme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C
<sub>80</sub>
, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>1346-3969</s0>
</fA01>
<fA03 i2="1">
<s0>Acoust. sci. technol.</s0>
</fA03>
<fA05>
<s2>26</s2>
</fA05>
<fA06>
<s2>2</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>HIDAKA (Takayuki)</s1>
</fA11>
<fA14 i1="01">
<s1>Takenaka R&D Institute, 1-5-1</s1>
<s2>Otsuka, Inzai, 270-1395</s2>
<s3>JPN</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA20>
<s1>128-135</s1>
</fA20>
<fA21>
<s1>2005</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>18937</s2>
<s5>354000126428240050</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2005 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>11 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>05-0264873</s0>
</fA47>
<fA60>
<s1>P</s1>
<s2>C</s2>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Acoustical science and technology</s0>
</fA64>
<fA66 i1="01">
<s0>JPN</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C
<sub>80</sub>
, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>001B40C55</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Acoustique salle</s0>
<s5>06</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Room acoustics</s0>
<s5>06</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Acústica sala</s0>
<s5>06</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Acoustique musicale</s0>
<s5>07</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Musical acoustics</s0>
<s5>07</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Acústica musical</s0>
<s5>07</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Localisation</s0>
<s5>08</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Localization</s0>
<s5>08</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Localización</s0>
<s5>08</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Réverbération acoustique</s0>
<s5>09</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Acoustic reverberation</s0>
<s5>09</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Reverberación acústica</s0>
<s5>09</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Audition binaurale</s0>
<s5>10</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Binaural hearing</s0>
<s5>10</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Audición binaural</s0>
<s5>10</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Norme</s0>
<s5>11</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Standards</s0>
<s5>11</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Norma</s0>
<s5>11</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Salle concert</s0>
<s5>12</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Concert hall</s0>
<s5>12</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Sala concierto</s0>
<s5>12</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Temps descente</s0>
<s5>15</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Decay time</s0>
<s5>15</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Tiempo bajada</s0>
<s5>15</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE">
<s0>Temps interauriculaire</s0>
<s5>16</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG">
<s0>Interaural time</s0>
<s5>16</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA">
<s0>Tiempo interauricular</s0>
<s5>16</s5>
</fC03>
<fC03 i1="10" i2="X" l="FRE">
<s0>Temps réverbération</s0>
<s5>23</s5>
</fC03>
<fC03 i1="10" i2="X" l="ENG">
<s0>Reverberation time</s0>
<s5>23</s5>
</fC03>
<fC03 i1="10" i2="X" l="SPA">
<s0>Tiempo reverberación</s0>
<s5>23</s5>
</fC03>
<fC03 i1="11" i2="X" l="FRE">
<s0>Corrélation croisée</s0>
<s5>24</s5>
</fC03>
<fC03 i1="11" i2="X" l="ENG">
<s0>Cross correlation</s0>
<s5>24</s5>
</fC03>
<fC03 i1="11" i2="X" l="SPA">
<s0>Correlación cruzada</s0>
<s5>24</s5>
</fC03>
<fC03 i1="12" i2="X" l="FRE">
<s0>Analyse objective</s0>
<s5>33</s5>
</fC03>
<fC03 i1="12" i2="X" l="ENG">
<s0>Objective analysis</s0>
<s5>33</s5>
</fC03>
<fC03 i1="12" i2="X" l="SPA">
<s0>Análisis objetivos</s0>
<s5>33</s5>
</fC03>
<fC03 i1="13" i2="X" l="FRE">
<s0>Mesure position</s0>
<s5>34</s5>
</fC03>
<fC03 i1="13" i2="X" l="ENG">
<s0>Position measurement</s0>
<s5>34</s5>
</fC03>
<fC03 i1="13" i2="X" l="SPA">
<s0>Medición posición</s0>
<s5>34</s5>
</fC03>
<fN21>
<s1>185</s1>
</fN21>
<fN44 i1="01">
<s1>OTO</s1>
</fN44>
<fN82>
<s1>OTO</s1>
</fN82>
</pA>
<pR>
<fA30 i1="01" i2="1" l="ENG">
<s1>Special issue on Room Acoulstics in honour of RADS 2004. Symposium</s1>
<s3>Island of Awaji JPN</s3>
<s4>2004-04-11</s4>
</fA30>
</pR>
</standard>
</inist>
<affiliations>
<list>
<country>
<li>Japon</li>
</country>
</list>
<tree>
<country name="Japon">
<noRegion>
<name sortKey="Hidaka, Takayuki" sort="Hidaka, Takayuki" uniqKey="Hidaka T" first="Takayuki" last="Hidaka">Takayuki Hidaka</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/OperaV1/Data/PascalFrancis/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000336 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Checkpoint/biblio.hfd -nk 000336 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    OperaV1
   |flux=    PascalFrancis
   |étape=   Checkpoint
   |type=    RBID
   |clé=     Pascal:05-0264873
   |texte=   Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement
}}

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu Apr 14 14:59:05 2016. Site generation: Thu Jan 4 23:09:23 2024