Serveur d'exploration sur l'opéra

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Correction of Acoustics in Historic Opera Theatres with the Use of Schroeder Diffuser

Identifieur interne : 000691 ( Main/Exploration ); précédent : 000690; suivant : 000692

Correction of Acoustics in Historic Opera Theatres with the Use of Schroeder Diffuser

Auteurs : Tadeusz Kamisi Ski [Pologne]

Source :

RBID : ISTEX:B2D290F69797DB44D1F8E35C41CAE64F969C87C6

Abstract

The paper deals with the problem of acoustic correction in historic opera theatres with the auditorium layout in the form of a horseshoe with deep underbalcony cavities limited with a semicircular wall surface. Both geometry of the cavities and excessive sound absorption determine acoustic phenomena registered in this area of the hall. The problem has been observed in the Theatre of Opera and Ballet in Lviv, Ukraine, where acoustic tests were carried out, simulation calculations performed, and finally a diffusion panel worked out designed for the rear wall of the underbalcony space. Acoustic measurements carried out after installation of the diffusers revealed favourable changes in the sound strength factor G within the range of medium and high frequencies in the underbalcony and auditorium centre area. By replacing textile tapestry with diffusion panels, a significant reduction of sound absorption was achieved for the frequency range above 1 kHz and an increase of uniformity of acoustic parameters registered in the hall. The method presented in the paper can be applied in historic halls of the similar type as well as contemporary rooms where there is a need for correction of acoustic flaws related to sound focusing or the echo effect.

Url:
DOI: 10.2478/v10168-012-0044-1


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Correction of Acoustics in Historic Opera Theatres with the Use of Schroeder Diffuser</title>
<author wicri:is="90%">
<name sortKey="Kamisi Ski, Tadeusz" sort="Kamisi Ski, Tadeusz" uniqKey="Kamisi Ski T" first="Tadeusz" last="Kamisi Ski">Tadeusz Kamisi Ski</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:B2D290F69797DB44D1F8E35C41CAE64F969C87C6</idno>
<date when="2012-11-29" year="2012">2012-11-29</date>
<idno type="doi">10.2478/v10168-012-0044-1</idno>
<idno type="url">https://api.istex.fr/document/B2D290F69797DB44D1F8E35C41CAE64F969C87C6/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000253</idno>
<idno type="wicri:Area/Istex/Curation">000253</idno>
<idno type="wicri:Area/Istex/Checkpoint">000022</idno>
<idno type="wicri:doubleKey">0137-5075:2012:Kamisi Ski T:correction:of:acoustics</idno>
<idno type="wicri:Area/Main/Merge">000692</idno>
<idno type="wicri:Area/Main/Curation">000691</idno>
<idno type="wicri:Area/Main/Exploration">000691</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Correction of Acoustics in Historic Opera Theatres with the Use of Schroeder Diffuser</title>
<author wicri:is="90%">
<name sortKey="Kamisi Ski, Tadeusz" sort="Kamisi Ski, Tadeusz" uniqKey="Kamisi Ski T" first="Tadeusz" last="Kamisi Ski">Tadeusz Kamisi Ski</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Pologne</country>
<wicri:regionArea>AGH University of Science and Technology al. A. Mickiewicza 30, 30-059 Kraków</wicri:regionArea>
<wicri:noRegion>30-059 Kraków</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1">
<country wicri:rule="url">Pologne</country>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Archives of Acoustics</title>
<idno type="ISSN">0137-5075</idno>
<imprint>
<publisher>Versita</publisher>
<date type="published" when="2012-11-01">2012-11-01</date>
<biblScope unit="volume">37</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="349">349</biblScope>
<biblScope unit="page" to="354">354</biblScope>
</imprint>
<idno type="ISSN">0137-5075</idno>
</series>
<idno type="istex">B2D290F69797DB44D1F8E35C41CAE64F969C87C6</idno>
<idno type="DOI">10.2478/v10168-012-0044-1</idno>
<idno type="ArticleID">v10168-012-0044-1</idno>
<idno type="Related-article-Href">v10168-012-0044-1.pdf</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0137-5075</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The paper deals with the problem of acoustic correction in historic opera theatres with the auditorium layout in the form of a horseshoe with deep underbalcony cavities limited with a semicircular wall surface. Both geometry of the cavities and excessive sound absorption determine acoustic phenomena registered in this area of the hall. The problem has been observed in the Theatre of Opera and Ballet in Lviv, Ukraine, where acoustic tests were carried out, simulation calculations performed, and finally a diffusion panel worked out designed for the rear wall of the underbalcony space. Acoustic measurements carried out after installation of the diffusers revealed favourable changes in the sound strength factor G within the range of medium and high frequencies in the underbalcony and auditorium centre area. By replacing textile tapestry with diffusion panels, a significant reduction of sound absorption was achieved for the frequency range above 1 kHz and an increase of uniformity of acoustic parameters registered in the hall. The method presented in the paper can be applied in historic halls of the similar type as well as contemporary rooms where there is a need for correction of acoustic flaws related to sound focusing or the echo effect.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Pologne</li>
</country>
</list>
<tree>
<country name="Pologne">
<noRegion>
<name sortKey="Kamisi Ski, Tadeusz" sort="Kamisi Ski, Tadeusz" uniqKey="Kamisi Ski T" first="Tadeusz" last="Kamisi Ski">Tadeusz Kamisi Ski</name>
</noRegion>
<name sortKey="Kamisi Ski, Tadeusz" sort="Kamisi Ski, Tadeusz" uniqKey="Kamisi Ski T" first="Tadeusz" last="Kamisi Ski">Tadeusz Kamisi Ski</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/OperaV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000691 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000691 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    OperaV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:B2D290F69797DB44D1F8E35C41CAE64F969C87C6
   |texte=   Correction of Acoustics in Historic Opera Theatres with the Use of Schroeder Diffuser
}}

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu Apr 14 14:59:05 2016. Site generation: Thu Jan 4 23:09:23 2024