Serveur d'exploration sur Mozart

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The consequences of microneurography electrode-induced injury of peripheral nerves observed in the rat and man

Identifieur interne : 003869 ( Main/Exploration ); précédent : 003868; suivant : 003870

The consequences of microneurography electrode-induced injury of peripheral nerves observed in the rat and man

Auteurs : Andrew S. C. Rice ; Nicholai Y. Andreev ; Stephen B. Mcmahon

Source :

RBID : ISTEX:BAD0B5AE8433E86840AC704303C765E66BAD9218

Abstract

The consequences of microneurography were assessed, using tungsten and coaxial electrodes in rat and man. Firstly, the sequelae of microneurography were examined for up to 1 month in a rat sciatic nerve model, using 3 techniques. Expression of the injury-associated protein GAP-43 was measured by immunofluorescence in sciatic nerve and dorsal root ganglia 3 and 28 days following sciatic nerve injury by microneurography electrodes. No increase in GAP-43 was observed in sciatic nerve 3 days following injury, but 28 days after injury the coaxial electrode was associated with an increase in GAP-43 expression. All electrodes were associated with an increase in GAP-43 in dorsal root ganglia 28 days after injury. The capacity of unmyelinated afferent fibres to induce neurogenic oedema was examined up to the 28th post-experimental day, as measured by Evan's Blue extravasation. The tungsten electrode induced a decrease in extravasation, which persisted for 28 days. In contrast, the decrease in plasma extravasation associated with lesions induced by the coaxial electrode returned to baseline within 7 days. The hind-limb withdrawal time from a noxious stimulus was also measured up to 28 days following injury. Both types of electrode induced a significant change in the immediate post-experimental period, but this returned to normal within 1 week. The direction of change differed between the tungsten and coaxial electrodes. In humans, symptomatology questionnaires were collected after microneurography experiments with the coaxial electrode. Thirty-two volunteers were studied. Two subjects reported mild paraesthesiae, which fully resolved within 24 h. This compares favourably with similar studies of the tungsten electrode.

Url:
DOI: 10.1016/0304-3959(94)90025-6


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>The consequences of microneurography electrode-induced injury of peripheral nerves observed in the rat and man</title>
<author>
<name sortKey="Rice, Andrew S C" sort="Rice, Andrew S C" uniqKey="Rice A" first="Andrew S. C." last="Rice">Andrew S. C. Rice</name>
</author>
<author>
<name sortKey="Andreev, Nicholai Y" sort="Andreev, Nicholai Y" uniqKey="Andreev N" first="Nicholai Y." last="Andreev">Nicholai Y. Andreev</name>
</author>
<author>
<name sortKey="Mcmahon, Stephen B" sort="Mcmahon, Stephen B" uniqKey="Mcmahon S" first="Stephen B." last="Mcmahon">Stephen B. Mcmahon</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:BAD0B5AE8433E86840AC704303C765E66BAD9218</idno>
<date when="1994" year="1994">1994</date>
<idno type="doi">10.1016/0304-3959(94)90025-6</idno>
<idno type="url">https://api.istex.fr/document/BAD0B5AE8433E86840AC704303C765E66BAD9218/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000815</idno>
<idno type="wicri:Area/Istex/Curation">000656</idno>
<idno type="wicri:Area/Istex/Checkpoint">002F89</idno>
<idno type="wicri:doubleKey">0304-3959:1994:Rice A:the:consequences:of</idno>
<idno type="wicri:Area/Main/Merge">003974</idno>
<idno type="wicri:Area/Main/Curation">003869</idno>
<idno type="wicri:Area/Main/Exploration">003869</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">The consequences of microneurography electrode-induced injury of peripheral nerves observed in the rat and man</title>
<author>
<name sortKey="Rice, Andrew S C" sort="Rice, Andrew S C" uniqKey="Rice A" first="Andrew S. C." last="Rice">Andrew S. C. Rice</name>
<affiliation>
<wicri:noCountry code="subField">London SE1 7EH UK</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Andreev, Nicholai Y" sort="Andreev, Nicholai Y" uniqKey="Andreev N" first="Nicholai Y." last="Andreev">Nicholai Y. Andreev</name>
<affiliation>
<wicri:noCountry code="subField">London SE1 7EH UK</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Mcmahon, Stephen B" sort="Mcmahon, Stephen B" uniqKey="Mcmahon S" first="Stephen B." last="Mcmahon">Stephen B. Mcmahon</name>
<affiliation>
<wicri:noCountry code="subField">London SE1 7EH UK</wicri:noCountry>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Pain</title>
<title level="j" type="abbrev">PAIN</title>
<idno type="ISSN">0304-3959</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1994">1994</date>
<biblScope unit="volume">59</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="385">385</biblScope>
<biblScope unit="page" to="393">393</biblScope>
</imprint>
<idno type="ISSN">0304-3959</idno>
</series>
<idno type="istex">BAD0B5AE8433E86840AC704303C765E66BAD9218</idno>
<idno type="DOI">10.1016/0304-3959(94)90025-6</idno>
<idno type="PII">0304-3959(94)90025-6</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0304-3959</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The consequences of microneurography were assessed, using tungsten and coaxial electrodes in rat and man. Firstly, the sequelae of microneurography were examined for up to 1 month in a rat sciatic nerve model, using 3 techniques. Expression of the injury-associated protein GAP-43 was measured by immunofluorescence in sciatic nerve and dorsal root ganglia 3 and 28 days following sciatic nerve injury by microneurography electrodes. No increase in GAP-43 was observed in sciatic nerve 3 days following injury, but 28 days after injury the coaxial electrode was associated with an increase in GAP-43 expression. All electrodes were associated with an increase in GAP-43 in dorsal root ganglia 28 days after injury. The capacity of unmyelinated afferent fibres to induce neurogenic oedema was examined up to the 28th post-experimental day, as measured by Evan's Blue extravasation. The tungsten electrode induced a decrease in extravasation, which persisted for 28 days. In contrast, the decrease in plasma extravasation associated with lesions induced by the coaxial electrode returned to baseline within 7 days. The hind-limb withdrawal time from a noxious stimulus was also measured up to 28 days following injury. Both types of electrode induced a significant change in the immediate post-experimental period, but this returned to normal within 1 week. The direction of change differed between the tungsten and coaxial electrodes. In humans, symptomatology questionnaires were collected after microneurography experiments with the coaxial electrode. Thirty-two volunteers were studied. Two subjects reported mild paraesthesiae, which fully resolved within 24 h. This compares favourably with similar studies of the tungsten electrode.</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Andreev, Nicholai Y" sort="Andreev, Nicholai Y" uniqKey="Andreev N" first="Nicholai Y." last="Andreev">Nicholai Y. Andreev</name>
<name sortKey="Mcmahon, Stephen B" sort="Mcmahon, Stephen B" uniqKey="Mcmahon S" first="Stephen B." last="Mcmahon">Stephen B. Mcmahon</name>
<name sortKey="Rice, Andrew S C" sort="Rice, Andrew S C" uniqKey="Rice A" first="Andrew S. C." last="Rice">Andrew S. C. Rice</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/MozartV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003869 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003869 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    MozartV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:BAD0B5AE8433E86840AC704303C765E66BAD9218
   |texte=   The consequences of microneurography electrode-induced injury of peripheral nerves observed in the rat and man
}}

Wicri

This area was generated with Dilib version V0.6.20.
Data generation: Sun Apr 10 15:06:14 2016. Site generation: Tue Feb 7 15:40:35 2023