Serveur d'exploration sur Mozart

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The QT‐Sensitive Cybernetic Pacemaker: A New Role for an Old Parameter?

Identifieur interne : 000186 ( France/Analysis ); précédent : 000185; suivant : 000187

The QT‐Sensitive Cybernetic Pacemaker: A New Role for an Old Parameter?

Auteurs : Paolo E. Puddu [Italie] ; Jean Torresani [France]

Source :

RBID : ISTEX:81113592B45ACA2E6E780B433C7F64986A4708B6

English descriptors

Abstract

A critical review of the available data on QT interval is presented to delineate techniques useful to the development of a QT‐sensitive cybernetic pacemaker. The reason for the development of this unit stems from the ability of QT prolongation to predict the onset of life‐threatening ventricular arrhythmias in some clinical situations; the QT interval is physiologically related to the cardiac cycle length, therefore providing adequate information to drive both ventricuiar and atrioventricuiar sequential rate‐responsive pacemakers. This unit might also monitor cardiac rhythm and detect the pathophysioiogic precursors of advanced grades of ventricular arrhythmias. A therapeutic role, both pharmacologic and electrical, may also be possible in the future. Integration of these concepts and cooperation between interested physicians, technicians and manufactors will be necessary to produce such a unit at a low cost‐benefit ratio. The potential clinical application of this pacemaker deserves attention for the prophylaxis and treatment of sudden arrhythmic death.

Url:
DOI: 10.1111/j.1540-8159.1986.tb05367.x


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:81113592B45ACA2E6E780B433C7F64986A4708B6

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The QT‐Sensitive Cybernetic Pacemaker: A New Role for an Old Parameter?</title>
<author>
<name sortKey="Puddu, Paolo E" sort="Puddu, Paolo E" uniqKey="Puddu P" first="Paolo E." last="Puddu">Paolo E. Puddu</name>
</author>
<author>
<name sortKey="Torresani, Jean" sort="Torresani, Jean" uniqKey="Torresani J" first="Jean" last="Torresani">Jean Torresani</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:81113592B45ACA2E6E780B433C7F64986A4708B6</idno>
<date when="1986" year="1986">1986</date>
<idno type="doi">10.1111/j.1540-8159.1986.tb05367.x</idno>
<idno type="url">https://api.istex.fr/document/81113592B45ACA2E6E780B433C7F64986A4708B6/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002A33</idno>
<idno type="wicri:Area/Istex/Curation">002576</idno>
<idno type="wicri:Area/Istex/Checkpoint">004798</idno>
<idno type="wicri:doubleKey">0147-8389:1986:Puddu P:the:qt:sensitive</idno>
<idno type="wicri:Area/Main/Merge">005325</idno>
<idno type="wicri:Area/Main/Curation">005129</idno>
<idno type="wicri:Area/Main/Exploration">005129</idno>
<idno type="wicri:Area/France/Extraction">000186</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">The QT‐Sensitive Cybernetic Pacemaker: A New Role for an Old Parameter?</title>
<author>
<name sortKey="Puddu, Paolo E" sort="Puddu, Paolo E" uniqKey="Puddu P" first="Paolo E." last="Puddu">Paolo E. Puddu</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Italie</country>
<wicri:regionArea>From II Cattedra di Cardiologia, University of La Sapienza, School of Medicine, Rome</wicri:regionArea>
<placeName>
<settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Torresani, Jean" sort="Torresani, Jean" uniqKey="Torresani J" first="Jean" last="Torresani">Jean Torresani</name>
<affiliation wicri:level="1">
<country xml:lang="fr">France</country>
<wicri:regionArea>Service de Cardiologie, Hôpital Nord, University of Marseille, School of Medicine and INSERM U‐175 (Experimental Cardiology), Marseille</wicri:regionArea>
<placeName>
<settlement type="city">Marseille</settlement>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Pacing and Clinical Electrophysiology</title>
<idno type="ISSN">0147-8389</idno>
<idno type="eISSN">1540-8159</idno>
<imprint>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="1986-01">1986-01</date>
<biblScope unit="volume">9</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="108">108</biblScope>
<biblScope unit="page" to="123">123</biblScope>
</imprint>
<idno type="ISSN">0147-8389</idno>
</series>
<idno type="istex">81113592B45ACA2E6E780B433C7F64986A4708B6</idno>
<idno type="DOI">10.1111/j.1540-8159.1986.tb05367.x</idno>
<idno type="ArticleID">PACE108</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0147-8389</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>QT interval</term>
<term>arrhythmias</term>
<term>cybernetic pacemaker</term>
<term>sudden death</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A critical review of the available data on QT interval is presented to delineate techniques useful to the development of a QT‐sensitive cybernetic pacemaker. The reason for the development of this unit stems from the ability of QT prolongation to predict the onset of life‐threatening ventricular arrhythmias in some clinical situations; the QT interval is physiologically related to the cardiac cycle length, therefore providing adequate information to drive both ventricuiar and atrioventricuiar sequential rate‐responsive pacemakers. This unit might also monitor cardiac rhythm and detect the pathophysioiogic precursors of advanced grades of ventricular arrhythmias. A therapeutic role, both pharmacologic and electrical, may also be possible in the future. Integration of these concepts and cooperation between interested physicians, technicians and manufactors will be necessary to produce such a unit at a low cost‐benefit ratio. The potential clinical application of this pacemaker deserves attention for the prophylaxis and treatment of sudden arrhythmic death.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>France</li>
<li>Italie</li>
</country>
<region>
<li>Latium</li>
</region>
<settlement>
<li>Marseille</li>
<li>Rome</li>
</settlement>
</list>
<tree>
<country name="Italie">
<region name="Latium">
<name sortKey="Puddu, Paolo E" sort="Puddu, Paolo E" uniqKey="Puddu P" first="Paolo E." last="Puddu">Paolo E. Puddu</name>
</region>
</country>
<country name="France">
<noRegion>
<name sortKey="Torresani, Jean" sort="Torresani, Jean" uniqKey="Torresani J" first="Jean" last="Torresani">Jean Torresani</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/MozartV1/Data/France/Analysis
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000186 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/France/Analysis/biblio.hfd -nk 000186 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    MozartV1
   |flux=    France
   |étape=   Analysis
   |type=    RBID
   |clé=     ISTEX:81113592B45ACA2E6E780B433C7F64986A4708B6
   |texte=   The QT‐Sensitive Cybernetic Pacemaker: A New Role for an Old Parameter?
}}

Wicri

This area was generated with Dilib version V0.6.20.
Data generation: Sun Apr 10 15:06:14 2016. Site generation: Tue Feb 7 15:40:35 2023