Abstract
A critical review of the available data on QT interval is presented to delineate techniques useful to the development of a QT‐sensitive cybernetic pacemaker. The reason for the development of this unit stems from the ability of QT prolongation to predict the onset of life‐threatening ventricular arrhythmias in some clinical situations; the QT interval is physiologically related to the cardiac cycle length, therefore providing adequate information to drive both ventricuiar and atrioventricuiar sequential rate‐responsive pacemakers. This unit might also monitor cardiac rhythm and detect the pathophysioiogic precursors of advanced grades of ventricular arrhythmias. A therapeutic role, both pharmacologic and electrical, may also be possible in the future. Integration of these concepts and cooperation between interested physicians, technicians and manufactors will be necessary to produce such a unit at a low cost‐benefit ratio. The potential clinical application of this pacemaker deserves attention for the prophylaxis and treatment of sudden arrhythmic death.
Url:
DOI: 10.1111/j.1540-8159.1986.tb05367.x
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 002A33
- to stream Istex, to step Curation: 002576
- to stream Istex, to step Checkpoint: 004798
- to stream Main, to step Merge: 005325
- to stream Main, to step Curation: 005129
- to stream Main, to step Exploration: 005129
- to stream France, to step Extraction: 000186
Links to Exploration step
ISTEX:81113592B45ACA2E6E780B433C7F64986A4708B6Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">The QT‐Sensitive Cybernetic Pacemaker: A New Role for an Old Parameter?</title>
<author><name sortKey="Puddu, Paolo E" sort="Puddu, Paolo E" uniqKey="Puddu P" first="Paolo E." last="Puddu">Paolo E. Puddu</name>
</author>
<author><name sortKey="Torresani, Jean" sort="Torresani, Jean" uniqKey="Torresani J" first="Jean" last="Torresani">Jean Torresani</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:81113592B45ACA2E6E780B433C7F64986A4708B6</idno>
<date when="1986" year="1986">1986</date>
<idno type="doi">10.1111/j.1540-8159.1986.tb05367.x</idno>
<idno type="url">https://api.istex.fr/document/81113592B45ACA2E6E780B433C7F64986A4708B6/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002A33</idno>
<idno type="wicri:Area/Istex/Curation">002576</idno>
<idno type="wicri:Area/Istex/Checkpoint">004798</idno>
<idno type="wicri:doubleKey">0147-8389:1986:Puddu P:the:qt:sensitive</idno>
<idno type="wicri:Area/Main/Merge">005325</idno>
<idno type="wicri:Area/Main/Curation">005129</idno>
<idno type="wicri:Area/Main/Exploration">005129</idno>
<idno type="wicri:Area/France/Extraction">000186</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">The QT‐Sensitive Cybernetic Pacemaker: A New Role for an Old Parameter?</title>
<author><name sortKey="Puddu, Paolo E" sort="Puddu, Paolo E" uniqKey="Puddu P" first="Paolo E." last="Puddu">Paolo E. Puddu</name>
<affiliation wicri:level="3"><country xml:lang="fr">Italie</country>
<wicri:regionArea>From II Cattedra di Cardiologia, University of La Sapienza, School of Medicine, Rome</wicri:regionArea>
<placeName><settlement type="city">Rome</settlement>
<region nuts="2">Latium</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Torresani, Jean" sort="Torresani, Jean" uniqKey="Torresani J" first="Jean" last="Torresani">Jean Torresani</name>
<affiliation wicri:level="1"><country xml:lang="fr">France</country>
<wicri:regionArea>Service de Cardiologie, Hôpital Nord, University of Marseille, School of Medicine and INSERM U‐175 (Experimental Cardiology), Marseille</wicri:regionArea>
<placeName><settlement type="city">Marseille</settlement>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Pacing and Clinical Electrophysiology</title>
<idno type="ISSN">0147-8389</idno>
<idno type="eISSN">1540-8159</idno>
<imprint><publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="1986-01">1986-01</date>
<biblScope unit="volume">9</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="108">108</biblScope>
<biblScope unit="page" to="123">123</biblScope>
</imprint>
<idno type="ISSN">0147-8389</idno>
</series>
<idno type="istex">81113592B45ACA2E6E780B433C7F64986A4708B6</idno>
<idno type="DOI">10.1111/j.1540-8159.1986.tb05367.x</idno>
<idno type="ArticleID">PACE108</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0147-8389</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>QT interval</term>
<term>arrhythmias</term>
<term>cybernetic pacemaker</term>
<term>sudden death</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A critical review of the available data on QT interval is presented to delineate techniques useful to the development of a QT‐sensitive cybernetic pacemaker. The reason for the development of this unit stems from the ability of QT prolongation to predict the onset of life‐threatening ventricular arrhythmias in some clinical situations; the QT interval is physiologically related to the cardiac cycle length, therefore providing adequate information to drive both ventricuiar and atrioventricuiar sequential rate‐responsive pacemakers. This unit might also monitor cardiac rhythm and detect the pathophysioiogic precursors of advanced grades of ventricular arrhythmias. A therapeutic role, both pharmacologic and electrical, may also be possible in the future. Integration of these concepts and cooperation between interested physicians, technicians and manufactors will be necessary to produce such a unit at a low cost‐benefit ratio. The potential clinical application of this pacemaker deserves attention for the prophylaxis and treatment of sudden arrhythmic death.</div>
</front>
</TEI>
<affiliations><list><country><li>France</li>
<li>Italie</li>
</country>
<region><li>Latium</li>
</region>
<settlement><li>Marseille</li>
<li>Rome</li>
</settlement>
</list>
<tree><country name="Italie"><region name="Latium"><name sortKey="Puddu, Paolo E" sort="Puddu, Paolo E" uniqKey="Puddu P" first="Paolo E." last="Puddu">Paolo E. Puddu</name>
</region>
</country>
<country name="France"><noRegion><name sortKey="Torresani, Jean" sort="Torresani, Jean" uniqKey="Torresani J" first="Jean" last="Torresani">Jean Torresani</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/MozartV1/Data/France/Analysis
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000186 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/France/Analysis/biblio.hfd -nk 000186 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Musique |area= MozartV1 |flux= France |étape= Analysis |type= RBID |clé= ISTEX:81113592B45ACA2E6E780B433C7F64986A4708B6 |texte= The QT‐Sensitive Cybernetic Pacemaker: A New Role for an Old Parameter? }}
This area was generated with Dilib version V0.6.20. |