Cross-sectional transmission electron microscopy of thin film polycrystalline semiconductors by conventional microtomy
Identifieur interne : 000740 ( Main/Exploration ); précédent : 000739; suivant : 000741Cross-sectional transmission electron microscopy of thin film polycrystalline semiconductors by conventional microtomy
Auteurs : Ana Albu-Yaron [Israël] ; Andre Frank [Israël] ; Gary Hodes [Israël] ; Rommel Noufi [États-Unis]Source :
- Thin Solid Films [ 0040-6090 ] ; 1992.
Abstract
Conventional ultramicrotomy with a glass knife is shown to be a valuable technique for studying thin film polycrystalline semiconductor materials in cross-section. High quality sections of CuInSe2 (CIS) polycrystalline thin films and of nanocrystalline PbSe films deposited on mica, suitable for electron microscopic investigations, can be obtained in large quantities within a very short time. Detailed cross-sectional transmission electron microscopy (XTEM) studies performed on CIS films revealed columnar grains of tetragonal chalcopyrite structure that nucleate at the CIS-mica interface. The average grain diameter is about 30–60 nm and increases with increasing distance from the substrate. Intergranular voids predominantly located near the interface were commonly observed. Microtwins on (112) planes were found in many of the grains. No second phases were observed in these samples. XTEM on nanocrystalline PbSe layers on mica revealed films made up of very small spherical grains (4–5 nm in diameter) of cubic PbSe dispersed in an amorphous matrix and uniformly distributed throughout the thickness of the layer.
Url:
DOI: 10.1016/0040-6090(93)90181-N
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 000241
- to stream Istex, to step Curation: 000234
- to stream Istex, to step Checkpoint: 000696
- to stream Main, to step Merge: 000743
- to stream Main, to step Curation: 000740
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title>Cross-sectional transmission electron microscopy of thin film polycrystalline semiconductors by conventional microtomy</title>
<author><name sortKey="Albu Yaron, Ana" sort="Albu Yaron, Ana" uniqKey="Albu Yaron A" first="Ana" last="Albu-Yaron">Ana Albu-Yaron</name>
</author>
<author><name sortKey="Frank, Andre" sort="Frank, Andre" uniqKey="Frank A" first="Andre" last="Frank">Andre Frank</name>
</author>
<author><name sortKey="Hodes, Gary" sort="Hodes, Gary" uniqKey="Hodes G" first="Gary" last="Hodes">Gary Hodes</name>
</author>
<author><name sortKey="Noufi, Rommel" sort="Noufi, Rommel" uniqKey="Noufi R" first="Rommel" last="Noufi">Rommel Noufi</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:98672A282B170DFAFBD1CE64F993A74A015ACF5B</idno>
<date when="1993" year="1993">1993</date>
<idno type="doi">10.1016/0040-6090(93)90181-N</idno>
<idno type="url">https://api.istex.fr/document/98672A282B170DFAFBD1CE64F993A74A015ACF5B/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000241</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000241</idno>
<idno type="wicri:Area/Istex/Curation">000234</idno>
<idno type="wicri:Area/Istex/Checkpoint">000696</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000696</idno>
<idno type="wicri:doubleKey">0040-6090:1993:Albu Yaron A:cross:sectional:transmission</idno>
<idno type="wicri:Area/Main/Merge">000743</idno>
<idno type="wicri:Area/Main/Curation">000740</idno>
<idno type="wicri:Area/Main/Exploration">000740</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a">Cross-sectional transmission electron microscopy of thin film polycrystalline semiconductors by conventional microtomy</title>
<author><name sortKey="Albu Yaron, Ana" sort="Albu Yaron, Ana" uniqKey="Albu Yaron A" first="Ana" last="Albu-Yaron">Ana Albu-Yaron</name>
<affiliation wicri:level="1"><country xml:lang="fr">Israël</country>
<wicri:regionArea>ARO, The Volcani Centre, POB 6</wicri:regionArea>
<wicri:noRegion>POB 6</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Frank, Andre" sort="Frank, Andre" uniqKey="Frank A" first="Andre" last="Frank">Andre Frank</name>
<affiliation wicri:level="1"><country xml:lang="fr">Israël</country>
<wicri:regionArea>ARO, The Volcani Centre, POB 6</wicri:regionArea>
<wicri:noRegion>POB 6</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Hodes, Gary" sort="Hodes, Gary" uniqKey="Hodes G" first="Gary" last="Hodes">Gary Hodes</name>
<affiliation wicri:level="1"><country xml:lang="fr">Israël</country>
<wicri:regionArea>The Weizmann Institute of Science</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Noufi, Rommel" sort="Noufi, Rommel" uniqKey="Noufi R" first="Rommel" last="Noufi">Rommel Noufi</name>
<affiliation wicri:level="2"><country>États-Unis</country>
<placeName><region type="state">Colorado</region>
</placeName>
<wicri:cityArea>National Renewable Energy Laboratory, Golden</wicri:cityArea>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Thin Solid Films</title>
<title level="j" type="abbrev">TSF</title>
<idno type="ISSN">0040-6090</idno>
<imprint><publisher>ELSEVIER</publisher>
<date type="published" when="1992">1992</date>
<biblScope unit="volume">227</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="18">18</biblScope>
<biblScope unit="page" to="23">23</biblScope>
</imprint>
<idno type="ISSN">0040-6090</idno>
</series>
<idno type="istex">98672A282B170DFAFBD1CE64F993A74A015ACF5B</idno>
<idno type="DOI">10.1016/0040-6090(93)90181-N</idno>
<idno type="PII">0040-6090(93)90181-N</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0040-6090</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass></textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Conventional ultramicrotomy with a glass knife is shown to be a valuable technique for studying thin film polycrystalline semiconductor materials in cross-section. High quality sections of CuInSe2 (CIS) polycrystalline thin films and of nanocrystalline PbSe films deposited on mica, suitable for electron microscopic investigations, can be obtained in large quantities within a very short time. Detailed cross-sectional transmission electron microscopy (XTEM) studies performed on CIS films revealed columnar grains of tetragonal chalcopyrite structure that nucleate at the CIS-mica interface. The average grain diameter is about 30–60 nm and increases with increasing distance from the substrate. Intergranular voids predominantly located near the interface were commonly observed. Microtwins on (112) planes were found in many of the grains. No second phases were observed in these samples. XTEM on nanocrystalline PbSe layers on mica revealed films made up of very small spherical grains (4–5 nm in diameter) of cubic PbSe dispersed in an amorphous matrix and uniformly distributed throughout the thickness of the layer.</div>
</front>
</TEI>
<affiliations><list><country><li>Israël</li>
<li>États-Unis</li>
</country>
<region><li>Colorado</li>
</region>
</list>
<tree><country name="Israël"><noRegion><name sortKey="Albu Yaron, Ana" sort="Albu Yaron, Ana" uniqKey="Albu Yaron A" first="Ana" last="Albu-Yaron">Ana Albu-Yaron</name>
</noRegion>
<name sortKey="Frank, Andre" sort="Frank, Andre" uniqKey="Frank A" first="Andre" last="Frank">Andre Frank</name>
<name sortKey="Hodes, Gary" sort="Hodes, Gary" uniqKey="Hodes G" first="Gary" last="Hodes">Gary Hodes</name>
</country>
<country name="États-Unis"><region name="Colorado"><name sortKey="Noufi, Rommel" sort="Noufi, Rommel" uniqKey="Noufi R" first="Rommel" last="Noufi">Rommel Noufi</name>
</region>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/MagnificatV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000740 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000740 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Musique |area= MagnificatV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:98672A282B170DFAFBD1CE64F993A74A015ACF5B |texte= Cross-sectional transmission electron microscopy of thin film polycrystalline semiconductors by conventional microtomy }}
This area was generated with Dilib version V0.6.31. |