Serveur d'exploration sur la méthode scrum

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Variables in the high-performance anion-exchange chromatography of proteins

Identifieur interne : 002F67 ( Istex/Curation ); précédent : 002F66; suivant : 002F68

Variables in the high-performance anion-exchange chromatography of proteins

Auteurs : George Vanecek [États-Unis] ; Fred E. Regnier [États-Unis]

Source :

RBID : ISTEX:3B51376DCA8AC3376FB77A1A5C3E475535F933F7

Abstract

The effect of mobile phase velocity, separation time, support pore diameter, column length, and temperature on resolution and loading capacity of a new commercially available high-performance anion-exchange support, SynChropak AX-300, has been examined. This material is a macroporous spherical silica of 10 μm particle size with a bonded polymeric amine layer. It was found that the heterogeneity of ovalbumin samples, combined with bovine serum albumin, make them useful probes in evaluation of anion-exchange supports. In the columns of 4.1 mm i.d., the highest resolutions of proteins were achieved at a flow rate of 0.25 ml/min. Up to 10 mg of protein per injection could be applied on a 4.1 × 250 mm AX-300 column with good resolution. Columns of 50 mm length had one-tenth the protein load capacity of a 250-mm column, retaining approximately 75% of the resolution.

Url:
DOI: 10.1016/0003-2697(80)90658-2

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:3B51376DCA8AC3376FB77A1A5C3E475535F933F7

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Variables in the high-performance anion-exchange chromatography of proteins</title>
<author>
<name sortKey="Vanecek, George" sort="Vanecek, George" uniqKey="Vanecek G" first="George" last="Vanecek">George Vanecek</name>
<affiliation wicri:level="2">
<mods:affiliation>Department of Biochemistry, Purdue University, West Lafayette, Indiana 47907 USA</mods:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName>
<region type="state">Indiana</region>
</placeName>
<wicri:cityArea>Department of Biochemistry, Purdue University, West Lafayette</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Regnier, Fred E" sort="Regnier, Fred E" uniqKey="Regnier F" first="Fred E." last="Regnier">Fred E. Regnier</name>
<affiliation wicri:level="2">
<mods:affiliation>Department of Biochemistry, Purdue University, West Lafayette, Indiana 47907 USA</mods:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName>
<region type="state">Indiana</region>
</placeName>
<wicri:cityArea>Department of Biochemistry, Purdue University, West Lafayette</wicri:cityArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:3B51376DCA8AC3376FB77A1A5C3E475535F933F7</idno>
<date when="1980" year="1980">1980</date>
<idno type="doi">10.1016/0003-2697(80)90658-2</idno>
<idno type="url">https://api.istex.fr/document/3B51376DCA8AC3376FB77A1A5C3E475535F933F7/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002F67</idno>
<idno type="wicri:Area/Istex/Curation">002F67</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Variables in the high-performance anion-exchange chromatography of proteins</title>
<author>
<name sortKey="Vanecek, George" sort="Vanecek, George" uniqKey="Vanecek G" first="George" last="Vanecek">George Vanecek</name>
<affiliation wicri:level="2">
<mods:affiliation>Department of Biochemistry, Purdue University, West Lafayette, Indiana 47907 USA</mods:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName>
<region type="state">Indiana</region>
</placeName>
<wicri:cityArea>Department of Biochemistry, Purdue University, West Lafayette</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Regnier, Fred E" sort="Regnier, Fred E" uniqKey="Regnier F" first="Fred E." last="Regnier">Fred E. Regnier</name>
<affiliation wicri:level="2">
<mods:affiliation>Department of Biochemistry, Purdue University, West Lafayette, Indiana 47907 USA</mods:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName>
<region type="state">Indiana</region>
</placeName>
<wicri:cityArea>Department of Biochemistry, Purdue University, West Lafayette</wicri:cityArea>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Analytical Biochemistry</title>
<title level="j" type="abbrev">YABIO</title>
<idno type="ISSN">0003-2697</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1980">1980</date>
<biblScope unit="volume">109</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="345">345</biblScope>
<biblScope unit="page" to="353">353</biblScope>
</imprint>
<idno type="ISSN">0003-2697</idno>
</series>
<idno type="istex">3B51376DCA8AC3376FB77A1A5C3E475535F933F7</idno>
<idno type="DOI">10.1016/0003-2697(80)90658-2</idno>
<idno type="PII">0003-2697(80)90658-2</idno>
<idno type="ArticleID">80906582</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0003-2697</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The effect of mobile phase velocity, separation time, support pore diameter, column length, and temperature on resolution and loading capacity of a new commercially available high-performance anion-exchange support, SynChropak AX-300, has been examined. This material is a macroporous spherical silica of 10 μm particle size with a bonded polymeric amine layer. It was found that the heterogeneity of ovalbumin samples, combined with bovine serum albumin, make them useful probes in evaluation of anion-exchange supports. In the columns of 4.1 mm i.d., the highest resolutions of proteins were achieved at a flow rate of 0.25 ml/min. Up to 10 mg of protein per injection could be applied on a 4.1 × 250 mm AX-300 column with good resolution. Columns of 50 mm length had one-tenth the protein load capacity of a 250-mm column, retaining approximately 75% of the resolution.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Informatique/explor/ScrumV1/Data/Istex/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002F67 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Curation/biblio.hfd -nk 002F67 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Informatique
   |area=    ScrumV1
   |flux=    Istex
   |étape=   Curation
   |type=    RBID
   |clé=     ISTEX:3B51376DCA8AC3376FB77A1A5C3E475535F933F7
   |texte=   Variables in the high-performance anion-exchange chromatography of proteins
}}

Wicri

This area was generated with Dilib version V0.6.39.
Data generation: Tue Mar 5 18:28:08 2024. Site generation: Tue Mar 5 18:45:01 2024