Serveur d'exploration sur la méthode scrum

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis

Identifieur interne : 000B72 ( Istex/Corpus ); précédent : 000B71; suivant : 000B73

Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis

Auteurs : A. J. Bourque ; A. S. Cohen

Source :

RBID : ISTEX:E4781321558A036DEDADC07F4F642627E6A908D6

Abstract

The analysis of antisense phosphorothioate DNA (SODN) in human plasma via direct injection using anion-exchange high-performance liquid chromatography (AE-HPLC) is presented. The method relies on the ability to selectively extract phosphorothioate DNA from undigested serum, plasma and urine on anion-exchange resins. The automated HPLC method can analyze a sample every 5 min with a limit of detection of 50 ng/ml (ppb). The DNA was collected, desalted and analyzed by capillary gel electrophoresis. Due to the high resolving power of this technique, a qualitative assessment of enzymatic degradation of the antisense oligonucleotide can be made.

Url:
DOI: 10.1016/0378-4347(94)00207-X

Links to Exploration step

ISTEX:E4781321558A036DEDADC07F4F642627E6A908D6

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis</title>
<author>
<name sortKey="Bourque, A J" sort="Bourque, A J" uniqKey="Bourque A" first="A. J." last="Bourque">A. J. Bourque</name>
<affiliation>
<mods:affiliation>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Cohen, A S" sort="Cohen, A S" uniqKey="Cohen A" first="A. S." last="Cohen">A. S. Cohen</name>
<affiliation>
<mods:affiliation>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:E4781321558A036DEDADC07F4F642627E6A908D6</idno>
<date when="1994" year="1994">1994</date>
<idno type="doi">10.1016/0378-4347(94)00207-X</idno>
<idno type="url">https://api.istex.fr/document/E4781321558A036DEDADC07F4F642627E6A908D6/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000B72</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis</title>
<author>
<name sortKey="Bourque, A J" sort="Bourque, A J" uniqKey="Bourque A" first="A. J." last="Bourque">A. J. Bourque</name>
<affiliation>
<mods:affiliation>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Cohen, A S" sort="Cohen, A S" uniqKey="Cohen A" first="A. S." last="Cohen">A. S. Cohen</name>
<affiliation>
<mods:affiliation>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of Chromatography B: Biomedical Sciences and Applications</title>
<title level="j" type="abbrev">CHROLD</title>
<idno type="ISSN">0378-4347</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1994">1994</date>
<biblScope unit="volume">662</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="343">343</biblScope>
<biblScope unit="page" to="349">349</biblScope>
</imprint>
<idno type="ISSN">0378-4347</idno>
</series>
<idno type="istex">E4781321558A036DEDADC07F4F642627E6A908D6</idno>
<idno type="DOI">10.1016/0378-4347(94)00207-X</idno>
<idno type="PII">0378-4347(94)00207-X</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0378-4347</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The analysis of antisense phosphorothioate DNA (SODN) in human plasma via direct injection using anion-exchange high-performance liquid chromatography (AE-HPLC) is presented. The method relies on the ability to selectively extract phosphorothioate DNA from undigested serum, plasma and urine on anion-exchange resins. The automated HPLC method can analyze a sample every 5 min with a limit of detection of 50 ng/ml (ppb). The DNA was collected, desalted and analyzed by capillary gel electrophoresis. Due to the high resolving power of this technique, a qualitative assessment of enzymatic degradation of the antisense oligonucleotide can be made.</div>
</front>
</TEI>
<istex>
<corpusName>elsevier</corpusName>
<author>
<json:item>
<name>A.J. Bourque</name>
<affiliations>
<json:string>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</json:string>
</affiliations>
</json:item>
<json:item>
<name>A.S. Cohen</name>
<affiliations>
<json:string>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</json:string>
</affiliations>
</json:item>
</author>
<language>
<json:string>eng</json:string>
</language>
<abstract>The analysis of antisense phosphorothioate DNA (SODN) in human plasma via direct injection using anion-exchange high-performance liquid chromatography (AE-HPLC) is presented. The method relies on the ability to selectively extract phosphorothioate DNA from undigested serum, plasma and urine on anion-exchange resins. The automated HPLC method can analyze a sample every 5 min with a limit of detection of 50 ng/ml (ppb). The DNA was collected, desalted and analyzed by capillary gel electrophoresis. Due to the high resolving power of this technique, a qualitative assessment of enzymatic degradation of the antisense oligonucleotide can be made.</abstract>
<qualityIndicators>
<score>3.841</score>
<pdfVersion>1.2</pdfVersion>
<pdfPageSize>612 x 756 pts</pdfPageSize>
<refBibsNative>true</refBibsNative>
<keywordCount>0</keywordCount>
<abstractCharCount>647</abstractCharCount>
<pdfWordCount>2713</pdfWordCount>
<pdfCharCount>18558</pdfCharCount>
<pdfPageCount>7</pdfPageCount>
<abstractWordCount>94</abstractWordCount>
</qualityIndicators>
<title>Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis</title>
<pii>
<json:string>0378-4347(94)00207-X</json:string>
</pii>
<genre>
<json:string>research-article</json:string>
</genre>
<host>
<volume>662</volume>
<pii>
<json:string>S0378-4347(00)X0355-6</json:string>
</pii>
<pages>
<last>349</last>
<first>343</first>
</pages>
<issn>
<json:string>0378-4347</json:string>
</issn>
<issue>2</issue>
<genre>
<json:string>Journal</json:string>
</genre>
<language>
<json:string>unknown</json:string>
</language>
<title>Journal of Chromatography B: Biomedical Sciences and Applications</title>
<publicationDate>1994</publicationDate>
</host>
<categories>
<wos>
<json:string>CHEMISTRY, ANALYTICAL</json:string>
<json:string>BIOCHEMICAL RESEARCH METHODS</json:string>
</wos>
</categories>
<publicationDate>1994</publicationDate>
<copyrightDate>1994</copyrightDate>
<doi>
<json:string>10.1016/0378-4347(94)00207-X</json:string>
</doi>
<id>E4781321558A036DEDADC07F4F642627E6A908D6</id>
<fulltext>
<json:item>
<original>true</original>
<mimetype>application/pdf</mimetype>
<extension>pdf</extension>
<uri>https://api.istex.fr/document/E4781321558A036DEDADC07F4F642627E6A908D6/fulltext/pdf</uri>
</json:item>
<json:item>
<original>true</original>
<mimetype>text/plain</mimetype>
<extension>txt</extension>
<uri>https://api.istex.fr/document/E4781321558A036DEDADC07F4F642627E6A908D6/fulltext/txt</uri>
</json:item>
<json:item>
<original>false</original>
<mimetype>application/zip</mimetype>
<extension>zip</extension>
<uri>https://api.istex.fr/document/E4781321558A036DEDADC07F4F642627E6A908D6/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/E4781321558A036DEDADC07F4F642627E6A908D6/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a">Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>ELSEVIER</publisher>
<availability>
<p>ELSEVIER</p>
</availability>
<date>1994</date>
</publicationStmt>
<sourceDesc>
<biblStruct type="inbook">
<analytic>
<title level="a">Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis</title>
<author>
<persName>
<forename type="first">A.J.</forename>
<surname>Bourque</surname>
</persName>
<affiliation>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</affiliation>
</author>
<author>
<persName>
<forename type="first">A.S.</forename>
<surname>Cohen</surname>
</persName>
<note type="correspondence">
<p>Corresponding author.</p>
</note>
<affiliation>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</affiliation>
</author>
</analytic>
<monogr>
<title level="j">Journal of Chromatography B: Biomedical Sciences and Applications</title>
<title level="j" type="abbrev">CHROLD</title>
<idno type="pISSN">0378-4347</idno>
<idno type="PII">S0378-4347(00)X0355-6</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1994"></date>
<biblScope unit="volume">662</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="343">343</biblScope>
<biblScope unit="page" to="349">349</biblScope>
</imprint>
</monogr>
<idno type="istex">E4781321558A036DEDADC07F4F642627E6A908D6</idno>
<idno type="DOI">10.1016/0378-4347(94)00207-X</idno>
<idno type="PII">0378-4347(94)00207-X</idno>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<creation>
<date>1994</date>
</creation>
<langUsage>
<language ident="en">en</language>
</langUsage>
<abstract xml:lang="en">
<p>The analysis of antisense phosphorothioate DNA (SODN) in human plasma via direct injection using anion-exchange high-performance liquid chromatography (AE-HPLC) is presented. The method relies on the ability to selectively extract phosphorothioate DNA from undigested serum, plasma and urine on anion-exchange resins. The automated HPLC method can analyze a sample every 5 min with a limit of detection of 50 ng/ml (ppb). The DNA was collected, desalted and analyzed by capillary gel electrophoresis. Due to the high resolving power of this technique, a qualitative assessment of enzymatic degradation of the antisense oligonucleotide can be made.</p>
</abstract>
</profileDesc>
<revisionDesc>
<change when="1994">Published</change>
</revisionDesc>
</teiHeader>
</istex:fulltextTEI>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Elsevier, elements deleted: tail">
<istex:xmlDeclaration>version="1.0" encoding="utf-8"</istex:xmlDeclaration>
<istex:docType PUBLIC="-//ES//DTD journal article DTD version 4.5.2//EN//XML" URI="art452.dtd" name="istex:docType"></istex:docType>
<istex:document>
<converted-article version="4.5.2" docsubtype="fla">
<item-info>
<jid>CHROMB</jid>
<aid>9400207X</aid>
<ce:pii>0378-4347(94)00207-X</ce:pii>
<ce:doi>10.1016/0378-4347(94)00207-X</ce:doi>
<ce:copyright type="unknown" year="1994"></ce:copyright>
</item-info>
<head>
<ce:title>Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis</ce:title>
<ce:author-group>
<ce:author>
<ce:given-name>A.J.</ce:given-name>
<ce:surname>Bourque</ce:surname>
</ce:author>
<ce:author>
<ce:given-name>A.S.</ce:given-name>
<ce:surname>Cohen</ce:surname>
<ce:cross-ref refid="COR1">
<ce:sup></ce:sup>
</ce:cross-ref>
</ce:author>
<ce:affiliation>
<ce:textfn>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</ce:textfn>
</ce:affiliation>
<ce:correspondence id="COR1">
<ce:label>*</ce:label>
<ce:text>Corresponding author.</ce:text>
</ce:correspondence>
</ce:author-group>
<ce:abstract>
<ce:section-title>Abstract</ce:section-title>
<ce:abstract-sec>
<ce:simple-para>The analysis of antisense phosphorothioate DNA (SODN) in human plasma via direct injection using anion-exchange high-performance liquid chromatography (AE-HPLC) is presented. The method relies on the ability to selectively extract phosphorothioate DNA from undigested serum, plasma and urine on anion-exchange resins. The automated HPLC method can analyze a sample every 5 min with a limit of detection of 50 ng/ml (ppb). The DNA was collected, desalted and analyzed by capillary gel electrophoresis. Due to the high resolving power of this technique, a qualitative assessment of enzymatic degradation of the antisense oligonucleotide can be made.</ce:simple-para>
</ce:abstract-sec>
</ce:abstract>
</head>
</converted-article>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo>
<title>Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA">
<title>Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis</title>
</titleInfo>
<name type="personal">
<namePart type="given">A.J.</namePart>
<namePart type="family">Bourque</namePart>
<affiliation>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">A.S.</namePart>
<namePart type="family">Cohen</namePart>
<affiliation>Hybridon, 1 Innovation Drive, Worcester, MA 01605, USA</affiliation>
<description>Corresponding author.</description>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="research-article" displayLabel="Full-length article"></genre>
<originInfo>
<publisher>ELSEVIER</publisher>
<dateIssued encoding="w3cdtf">1994</dateIssued>
<copyrightDate encoding="w3cdtf">1994</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
</language>
<physicalDescription>
<internetMediaType>text/html</internetMediaType>
</physicalDescription>
<abstract lang="en">The analysis of antisense phosphorothioate DNA (SODN) in human plasma via direct injection using anion-exchange high-performance liquid chromatography (AE-HPLC) is presented. The method relies on the ability to selectively extract phosphorothioate DNA from undigested serum, plasma and urine on anion-exchange resins. The automated HPLC method can analyze a sample every 5 min with a limit of detection of 50 ng/ml (ppb). The DNA was collected, desalted and analyzed by capillary gel electrophoresis. Due to the high resolving power of this technique, a qualitative assessment of enzymatic degradation of the antisense oligonucleotide can be made.</abstract>
<relatedItem type="host">
<titleInfo>
<title>Journal of Chromatography B: Biomedical Sciences and Applications</title>
</titleInfo>
<titleInfo type="abbreviated">
<title>CHROLD</title>
</titleInfo>
<genre type="Journal">journal</genre>
<originInfo>
<dateIssued encoding="w3cdtf">19941209</dateIssued>
</originInfo>
<identifier type="ISSN">0378-4347</identifier>
<identifier type="PII">S0378-4347(00)X0355-6</identifier>
<part>
<date>19941209</date>
<detail type="volume">
<number>662</number>
<caption>vol.</caption>
</detail>
<detail type="issue">
<number>2</number>
<caption>no.</caption>
</detail>
<extent unit="issue pages">
<start>141</start>
<end>378</end>
</extent>
<extent unit="pages">
<start>343</start>
<end>349</end>
</extent>
</part>
</relatedItem>
<identifier type="istex">E4781321558A036DEDADC07F4F642627E6A908D6</identifier>
<identifier type="DOI">10.1016/0378-4347(94)00207-X</identifier>
<identifier type="PII">0378-4347(94)00207-X</identifier>
<recordInfo>
<recordContentSource>ELSEVIER</recordContentSource>
</recordInfo>
</mods>
</metadata>
<enrichments>
<istex:catWosTEI uri="https://api.istex.fr/document/E4781321558A036DEDADC07F4F642627E6A908D6/enrichments/catWos">
<teiHeader>
<profileDesc>
<textClass>
<classCode scheme="WOS">CHEMISTRY, ANALYTICAL</classCode>
<classCode scheme="WOS">BIOCHEMICAL RESEARCH METHODS</classCode>
</textClass>
</profileDesc>
</teiHeader>
</istex:catWosTEI>
</enrichments>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Informatique/explor/ScrumV1/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000B72 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 000B72 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Informatique
   |area=    ScrumV1
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:E4781321558A036DEDADC07F4F642627E6A908D6
   |texte=   Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using direct injection fast anion-exchange chromatography and capillary gel electrophoresis
}}

Wicri

This area was generated with Dilib version V0.6.39.
Data generation: Tue Mar 5 18:28:08 2024. Site generation: Tue Mar 5 18:45:01 2024