Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

New posterior chamber lens with open circular haptic for a small capsular opening: preliminary report.

Identifieur interne : 002229 ( PubMed/Curation ); précédent : 002228; suivant : 002230

New posterior chamber lens with open circular haptic for a small capsular opening: preliminary report.

Auteurs : O. Nishi [Japon]

Source :

RBID : pubmed:2231384

English descriptors

Abstract

This report describes a single-piece poly-(methyl methacrylate) posterior chamber lens for implantation through a small capsular opening. It has open circular loops with an eyelet at each loop end. The optic is 6 mm in diameter and the overall diameter of the intraocular lens (IOL) is 11 mm. The lens diameter can be reduced to 7 mm by grasping the eyelets at both open loop ends with a specially designed holding forceps. The IOL is inserted in the capsular bag after circular capsulorhexis or through a linear capsulotomy in the intercapsular technique. This IOL is adaptable to a small capsular opening and maintains the usual shape of the capsular bag, similar to a disc lens.

PubMed: 2231384

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:2231384

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">New posterior chamber lens with open circular haptic for a small capsular opening: preliminary report.</title>
<author>
<name sortKey="Nishi, O" sort="Nishi, O" uniqKey="Nishi O" first="O" last="Nishi">O. Nishi</name>
<affiliation wicri:level="1">
<nlm:affiliation>Nishi Eye Hospital, Osaka, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Nishi Eye Hospital, Osaka</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1990">1990</date>
<idno type="RBID">pubmed:2231384</idno>
<idno type="pmid">2231384</idno>
<idno type="wicri:Area/PubMed/Corpus">002229</idno>
<idno type="wicri:Area/PubMed/Curation">002229</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">New posterior chamber lens with open circular haptic for a small capsular opening: preliminary report.</title>
<author>
<name sortKey="Nishi, O" sort="Nishi, O" uniqKey="Nishi O" first="O" last="Nishi">O. Nishi</name>
<affiliation wicri:level="1">
<nlm:affiliation>Nishi Eye Hospital, Osaka, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Nishi Eye Hospital, Osaka</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="1990" type="published">1990</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Animals</term>
<term>Female</term>
<term>Humans</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Prosthesis Design</term>
<term>Swine</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Animals</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Prosthesis Design</term>
<term>Swine</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This report describes a single-piece poly-(methyl methacrylate) posterior chamber lens for implantation through a small capsular opening. It has open circular loops with an eyelet at each loop end. The optic is 6 mm in diameter and the overall diameter of the intraocular lens (IOL) is 11 mm. The lens diameter can be reduced to 7 mm by grasping the eyelets at both open loop ends with a specially designed holding forceps. The IOL is inserted in the capsular bag after circular capsulorhexis or through a linear capsulotomy in the intercapsular technique. This IOL is adaptable to a small capsular opening and maintains the usual shape of the capsular bag, similar to a disc lens.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">2231384</PMID>
<DateCreated>
<Year>1990</Year>
<Month>12</Month>
<Day>05</Day>
</DateCreated>
<DateCompleted>
<Year>1990</Year>
<Month>12</Month>
<Day>05</Day>
</DateCompleted>
<DateRevised>
<Year>2008</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>16</Volume>
<Issue>5</Issue>
<PubDate>
<Year>1990</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>New posterior chamber lens with open circular haptic for a small capsular opening: preliminary report.</ArticleTitle>
<Pagination>
<MedlinePgn>640-3</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>This report describes a single-piece poly-(methyl methacrylate) posterior chamber lens for implantation through a small capsular opening. It has open circular loops with an eyelet at each loop end. The optic is 6 mm in diameter and the overall diameter of the intraocular lens (IOL) is 11 mm. The lens diameter can be reduced to 7 mm by grasping the eyelets at both open loop ends with a specially designed holding forceps. The IOL is inserted in the capsular bag after circular capsulorhexis or through a linear capsulotomy in the intercapsular technique. This IOL is adaptable to a small capsular opening and maintains the usual shape of the capsular bag, similar to a disc lens.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Nishi</LastName>
<ForeName>O</ForeName>
<Initials>O</Initials>
<AffiliationInfo>
<Affiliation>Nishi Eye Hospital, Osaka, Japan.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000818">Animals</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D055095">Optics and Photonics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013552">Swine</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1990</Year>
<Month>9</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1990</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1990</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">2231384</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002229 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 002229 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:2231384
   |texte=   New posterior chamber lens with open circular haptic for a small capsular opening: preliminary report.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:2231384" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024