Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Surgeons and non-surgeons prefer haptic feedback of instrument vibrations during robotic surgery.

Identifieur interne : 000460 ( PubMed/Curation ); précédent : 000459; suivant : 000461

Surgeons and non-surgeons prefer haptic feedback of instrument vibrations during robotic surgery.

Auteurs : Jacqueline K. Koehn [États-Unis] ; Katherine J. Kuchenbecker [États-Unis]

Source :

RBID : pubmed:25539693

English descriptors

Abstract

Clinical robotic surgery systems do not currently provide haptic feedback because surgical instrument interactions are difficult to measure and display. Our laboratory recently developed a technology that allows surgeons to feel and/or hear the high-frequency vibrations of robotic instruments as they interact with patient tissue and other tools. Until now, this type of feedback had not been carefully evaluated by users.

DOI: 10.1007/s00464-014-4030-8
PubMed: 25539693

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:25539693

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Surgeons and non-surgeons prefer haptic feedback of instrument vibrations during robotic surgery.</title>
<author>
<name sortKey="Koehn, Jacqueline K" sort="Koehn, Jacqueline K" uniqKey="Koehn J" first="Jacqueline K" last="Koehn">Jacqueline K. Koehn</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315, USA. jackie.koehn@gmail.com.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Kuchenbecker, Katherine J" sort="Kuchenbecker, Katherine J" uniqKey="Kuchenbecker K" first="Katherine J" last="Kuchenbecker">Katherine J. Kuchenbecker</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315, USA. kuchenbe@seas.upenn.edu.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="RBID">pubmed:25539693</idno>
<idno type="pmid">25539693</idno>
<idno type="doi">10.1007/s00464-014-4030-8</idno>
<idno type="wicri:Area/PubMed/Corpus">000460</idno>
<idno type="wicri:Area/PubMed/Curation">000460</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Surgeons and non-surgeons prefer haptic feedback of instrument vibrations during robotic surgery.</title>
<author>
<name sortKey="Koehn, Jacqueline K" sort="Koehn, Jacqueline K" uniqKey="Koehn J" first="Jacqueline K" last="Koehn">Jacqueline K. Koehn</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315, USA. jackie.koehn@gmail.com.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Kuchenbecker, Katherine J" sort="Kuchenbecker, Katherine J" uniqKey="Kuchenbecker K" first="Katherine J" last="Kuchenbecker">Katherine J. Kuchenbecker</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315, USA. kuchenbe@seas.upenn.edu.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Surgical endoscopy</title>
<idno type="eISSN">1432-2218</idno>
<imprint>
<date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Attitude of Health Personnel</term>
<term>Feedback</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Robotic Surgical Procedures (instrumentation)</term>
<term>Surgeons</term>
<term>Surgical Instruments</term>
<term>Touch</term>
<term>Vibration</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Robotic Surgical Procedures</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Attitude of Health Personnel</term>
<term>Feedback</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Surgeons</term>
<term>Surgical Instruments</term>
<term>Touch</term>
<term>Vibration</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Clinical robotic surgery systems do not currently provide haptic feedback because surgical instrument interactions are difficult to measure and display. Our laboratory recently developed a technology that allows surgeons to feel and/or hear the high-frequency vibrations of robotic instruments as they interact with patient tissue and other tools. Until now, this type of feedback had not been carefully evaluated by users.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">25539693</PMID>
<DateCreated>
<Year>2015</Year>
<Month>09</Month>
<Day>24</Day>
</DateCreated>
<DateCompleted>
<Year>2016</Year>
<Month>05</Month>
<Day>18</Day>
</DateCompleted>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1432-2218</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>29</Volume>
<Issue>10</Issue>
<PubDate>
<Year>2015</Year>
<Month>Oct</Month>
</PubDate>
</JournalIssue>
<Title>Surgical endoscopy</Title>
<ISOAbbreviation>Surg Endosc</ISOAbbreviation>
</Journal>
<ArticleTitle>Surgeons and non-surgeons prefer haptic feedback of instrument vibrations during robotic surgery.</ArticleTitle>
<Pagination>
<MedlinePgn>2970-83</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1007/s00464-014-4030-8</ELocationID>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Clinical robotic surgery systems do not currently provide haptic feedback because surgical instrument interactions are difficult to measure and display. Our laboratory recently developed a technology that allows surgeons to feel and/or hear the high-frequency vibrations of robotic instruments as they interact with patient tissue and other tools. Until now, this type of feedback had not been carefully evaluated by users.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">We conducted two human-subject studies to discover whether surgeons and non-surgeons value the addition of vibration feedback from surgical instruments during robotic surgery. In the first experiment, 10 surgeons and 10 non-surgeons (n = 20) used an augmented Intuitive da Vinci Standard robot to repeatedly perform up to four dry-lab tasks both with and without haptic and audio feedback. In the second experiment, 68 surgeons and 26 non-surgeons (n = 94) tested the same robot at a surgical conference: each participant spent approximately 5 min performing one or two tasks.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Almost all subjects in both experiments (95 and 98 %, respectively) preferred receiving feedback of tool vibrations, and all subjects in the second experiment thought it would be useful for surgeons to have the option of such feedback. About half of the subjects (50, 60 %) preferred haptic and audio feedback together, and almost all the rest (45, 35 %) preferred haptic feedback alone. Subjects stated that the feedback made them more aware of tool contacts and did not interfere with use of the robot. There were no significant differences between the responses of different subject populations for any questions in either experiment.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">This study illustrates that both surgeons and non-surgeons prefer instrument vibration feedback during robotic surgery. Some participants found audio feedback useful but most preferred haptic feedback overall. This strong preference for tool vibration feedback indicates that this technology provides valuable tactile information to the surgeon.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Koehn</LastName>
<ForeName>Jacqueline K</ForeName>
<Initials>JK</Initials>
<AffiliationInfo>
<Affiliation>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315, USA. jackie.koehn@gmail.com.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Kuchenbecker</LastName>
<ForeName>Katherine J</ForeName>
<Initials>KJ</Initials>
<AffiliationInfo>
<Affiliation>Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 229 Towne Building, 220 S. 33rd Street, Philadelphia, 19104-6315, USA. kuchenbe@seas.upenn.edu.</Affiliation>
</AffiliationInfo>
<AffiliationInfo>
<Affiliation>Department of Computer and Information Science, University of Pennsylvania, Philadelphia, USA. kuchenbe@seas.upenn.edu.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2014</Year>
<Month>12</Month>
<Day>25</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Surg Endosc</MedlineTA>
<NlmUniqueID>8806653</NlmUniqueID>
<ISSNLinking>0930-2794</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001291">Attitude of Health Personnel</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D005246">Feedback</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D065287">Robotic Surgical Procedures</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D066231">Surgeons</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D013525">Surgical Instruments</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014110">Touch</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014732">Vibration</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">Audio feedback</Keyword>
<Keyword MajorTopicYN="N">Haptic feedback</Keyword>
<Keyword MajorTopicYN="N">Robotic surgery</Keyword>
<Keyword MajorTopicYN="N">Vibrotactile</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2014</Year>
<Month>9</Month>
<Day>18</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2014</Year>
<Month>11</Month>
<Day>28</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="aheadofprint">
<Year>2014</Year>
<Month>12</Month>
<Day>25</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>12</Month>
<Day>26</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>12</Month>
<Day>30</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2016</Year>
<Month>5</Month>
<Day>19</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25539693</ArticleId>
<ArticleId IdType="doi">10.1007/s00464-014-4030-8</ArticleId>
<ArticleId IdType="pii">10.1007/s00464-014-4030-8</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000460 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000460 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:25539693
   |texte=   Surgeons and non-surgeons prefer haptic feedback of instrument vibrations during robotic surgery.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:25539693" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024