Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The effects of absence of stereopsis on performance of a simulated surgical task in two-dimensional and three-dimensional viewing conditions

Identifieur interne : 000886 ( Pmc/Checkpoint ); précédent : 000885; suivant : 000887

The effects of absence of stereopsis on performance of a simulated surgical task in two-dimensional and three-dimensional viewing conditions

Auteurs : Edward Bloch [Royaume-Uni] ; Nabil Uddin [Royaume-Uni] ; Laura Gannon [Royaume-Uni] ; Khadija Rantell [Royaume-Uni] ; Saurabh Jain [Royaume-Uni]

Source :

RBID : PMC:4316921

Abstract

Background

Stereopsis is believed to be advantageous for surgical tasks that require precise hand-eye coordination. We investigated the effects of short-term and long-term absence of stereopsis on motor task performance in three-dimensional (3D) and two-dimensional (2D) viewing conditions.

Methods

30 participants with normal stereopsis and 15 participants with absent stereopsis performed a simulated surgical task both in free space under direct vision (3D) and via a monitor (2D), with both eyes open and one eye covered in each condition.

Results

The stereo-normal group scored higher, on average, than the stereo-absent group with both eyes open under direct vision (p<0.001). Both groups performed comparably in monocular and binocular monitor viewing conditions (p=0.579).

Conclusions

High-grade stereopsis confers an advantage when performing a fine motor task under direct vision. However, stereopsis does not appear advantageous to task performance under 2D viewing conditions, such as in video-assisted surgery.


Url:
DOI: 10.1136/bjophthalmol-2013-304517
PubMed: 25185439
PubMed Central: 4316921


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:4316921

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The effects of absence of stereopsis on performance of a simulated surgical task in two-dimensional and three-dimensional viewing conditions</title>
<author>
<name sortKey="Bloch, Edward" sort="Bloch, Edward" uniqKey="Bloch E" first="Edward" last="Bloch">Edward Bloch</name>
<affiliation wicri:level="1">
<nlm:aff id="af1">
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
<affiliation wicri:level="1">
<nlm:aff id="af2">
<institution>University College London Medical School</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Uddin, Nabil" sort="Uddin, Nabil" uniqKey="Uddin N" first="Nabil" last="Uddin">Nabil Uddin</name>
<affiliation wicri:level="1">
<nlm:aff id="af1">
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Gannon, Laura" sort="Gannon, Laura" uniqKey="Gannon L" first="Laura" last="Gannon">Laura Gannon</name>
<affiliation wicri:level="1">
<nlm:aff id="af1">
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Rantell, Khadija" sort="Rantell, Khadija" uniqKey="Rantell K" first="Khadija" last="Rantell">Khadija Rantell</name>
<affiliation wicri:level="1">
<nlm:aff id="af3">
<institution>Institute of Neurology, University College London</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Jain, Saurabh" sort="Jain, Saurabh" uniqKey="Jain S" first="Saurabh" last="Jain">Saurabh Jain</name>
<affiliation wicri:level="1">
<nlm:aff id="af1">
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
<affiliation wicri:level="1">
<nlm:aff id="af2">
<institution>University College London Medical School</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">25185439</idno>
<idno type="pmc">4316921</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4316921</idno>
<idno type="RBID">PMC:4316921</idno>
<idno type="doi">10.1136/bjophthalmol-2013-304517</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">001C17</idno>
<idno type="wicri:Area/Pmc/Curation">001C17</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000886</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">The effects of absence of stereopsis on performance of a simulated surgical task in two-dimensional and three-dimensional viewing conditions</title>
<author>
<name sortKey="Bloch, Edward" sort="Bloch, Edward" uniqKey="Bloch E" first="Edward" last="Bloch">Edward Bloch</name>
<affiliation wicri:level="1">
<nlm:aff id="af1">
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
<affiliation wicri:level="1">
<nlm:aff id="af2">
<institution>University College London Medical School</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Uddin, Nabil" sort="Uddin, Nabil" uniqKey="Uddin N" first="Nabil" last="Uddin">Nabil Uddin</name>
<affiliation wicri:level="1">
<nlm:aff id="af1">
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Gannon, Laura" sort="Gannon, Laura" uniqKey="Gannon L" first="Laura" last="Gannon">Laura Gannon</name>
<affiliation wicri:level="1">
<nlm:aff id="af1">
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Rantell, Khadija" sort="Rantell, Khadija" uniqKey="Rantell K" first="Khadija" last="Rantell">Khadija Rantell</name>
<affiliation wicri:level="1">
<nlm:aff id="af3">
<institution>Institute of Neurology, University College London</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Jain, Saurabh" sort="Jain, Saurabh" uniqKey="Jain S" first="Saurabh" last="Jain">Saurabh Jain</name>
<affiliation wicri:level="1">
<nlm:aff id="af1">
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
<affiliation wicri:level="1">
<nlm:aff id="af2">
<institution>University College London Medical School</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">The British Journal of Ophthalmology</title>
<idno type="ISSN">0007-1161</idno>
<idno type="eISSN">1468-2079</idno>
<imprint>
<date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Background</title>
<p>Stereopsis is believed to be advantageous for surgical tasks that require precise hand-eye coordination. We investigated the effects of short-term and long-term absence of stereopsis on motor task performance in three-dimensional (3D) and two-dimensional (2D) viewing conditions.</p>
</sec>
<sec>
<title>Methods</title>
<p>30 participants with normal stereopsis and 15 participants with absent stereopsis performed a simulated surgical task both in free space under direct vision (3D) and via a monitor (2D), with both eyes open and one eye covered in each condition.</p>
</sec>
<sec>
<title>Results</title>
<p>The stereo-normal group scored higher, on average, than the stereo-absent group with both eyes open under direct vision (p<0.001). Both groups performed comparably in monocular and binocular monitor viewing conditions (p=0.579).</p>
</sec>
<sec>
<title>Conclusions</title>
<p>High-grade stereopsis confers an advantage when performing a fine motor task under direct vision. However, stereopsis does not appear advantageous to task performance under 2D viewing conditions, such as in video-assisted surgery.</p>
</sec>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Wheatstone, C" uniqKey="Wheatstone C">C Wheatstone</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Fielder, Ar" uniqKey="Fielder A">AR Fielder</name>
</author>
<author>
<name sortKey="Moseley, Mj" uniqKey="Moseley M">MJ Moseley</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ansons, Ma" uniqKey="Ansons M">MA Ansons</name>
</author>
<author>
<name sortKey="Davis, H" uniqKey="Davis H">H Davis</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Schreuder, Hwr" uniqKey="Schreuder H">HWR Schreuder</name>
</author>
<author>
<name sortKey="Van Den Berg, Cb" uniqKey="Van Den Berg C">CB van den Berg</name>
</author>
<author>
<name sortKey="Hazebroek, Ej" uniqKey="Hazebroek E">EJ Hazebroek</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Twisk, Jwr" uniqKey="Twisk J">JWR Twisk</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Barlow, Hb" uniqKey="Barlow H">HB Barlow</name>
</author>
<author>
<name sortKey="Blakemore, C" uniqKey="Blakemore C">C Blakemore</name>
</author>
<author>
<name sortKey="Pettigrew, Jd" uniqKey="Pettigrew J">JD Pettigrew</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Westheimer, G" uniqKey="Westheimer G">G Westheimer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gallagher, Ag" uniqKey="Gallagher A">AG Gallagher</name>
</author>
<author>
<name sortKey="Ritter, Em" uniqKey="Ritter E">EM Ritter</name>
</author>
<author>
<name sortKey="Lederman, Ab" uniqKey="Lederman A">AB Lederman</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Melmouth, Dr" uniqKey="Melmouth D">DR Melmouth</name>
</author>
<author>
<name sortKey="Grant, S" uniqKey="Grant S">S Grant</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Read, Jc" uniqKey="Read J">JC Read</name>
</author>
<author>
<name sortKey="Begum, Sf" uniqKey="Begum S">SF Begum</name>
</author>
<author>
<name sortKey="Mcdonald, A" uniqKey="Mcdonald A">A McDonald</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Mazyn, Lin" uniqKey="Mazyn L">LIN Mazyn</name>
</author>
<author>
<name sortKey="Lenoir, M" uniqKey="Lenoir M">M Lenoir</name>
</author>
<author>
<name sortKey="Montagne, G" uniqKey="Montagne G">G Montagne</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Melmouth, Dr" uniqKey="Melmouth D">DR Melmouth</name>
</author>
<author>
<name sortKey="Finlay, Al" uniqKey="Finlay A">AL Finlay</name>
</author>
<author>
<name sortKey="Morgan, Mj" uniqKey="Morgan M">MJ Morgan</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Suttle, Cm" uniqKey="Suttle C">CM Suttle</name>
</author>
<author>
<name sortKey="Melmouth, Dr" uniqKey="Melmouth D">DR Melmouth</name>
</author>
<author>
<name sortKey="Finlay, Al" uniqKey="Finlay A">AL Finlay</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Barry, Gp" uniqKey="Barry G">GP Barry</name>
</author>
<author>
<name sortKey="Simon, Jw" uniqKey="Simon J">JW Simon</name>
</author>
<author>
<name sortKey="Auringer, D" uniqKey="Auringer D">D Auringer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Suleman, R" uniqKey="Suleman R">R Suleman</name>
</author>
<author>
<name sortKey="Yang, T" uniqKey="Yang T">T Yang</name>
</author>
<author>
<name sortKey="Paige, J" uniqKey="Paige J">J Paige</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="O Connor, Ar" uniqKey="O Connor A">AR O'Connor</name>
</author>
<author>
<name sortKey="Birch, Ee" uniqKey="Birch E">EE Birch</name>
</author>
<author>
<name sortKey="Anderson, S" uniqKey="Anderson S">S Anderson</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Smith, El" uniqKey="Smith E">EL Smith</name>
</author>
<author>
<name sortKey="Levi, Dm" uniqKey="Levi D">DM Levi</name>
</author>
<author>
<name sortKey="Manny, Re" uniqKey="Manny R">RE Manny</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Loftus, A" uniqKey="Loftus A">A Loftus</name>
</author>
<author>
<name sortKey="Servos, P" uniqKey="Servos P">P Servos</name>
</author>
<author>
<name sortKey="Goodale, Ma" uniqKey="Goodale M">MA Goodale</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bradshaw, Mf" uniqKey="Bradshaw M">MF Bradshaw</name>
</author>
<author>
<name sortKey="Elliott, Km" uniqKey="Elliott K">KM Elliott</name>
</author>
<author>
<name sortKey="Watt, Sj" uniqKey="Watt S">SJ Watt</name>
</author>
</analytic>
</biblStruct>
<biblStruct></biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sachdeva, R" uniqKey="Sachdeva R">R Sachdeva</name>
</author>
<author>
<name sortKey="Traboulsi, Ei" uniqKey="Traboulsi E">EI Traboulsi</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Waqar, S" uniqKey="Waqar S">S Waqar</name>
</author>
<author>
<name sortKey="Williams, O" uniqKey="Williams O">O Williams</name>
</author>
<author>
<name sortKey="Park, J" uniqKey="Park J">J Park</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Binenbaum, G" uniqKey="Binenbaum G">G Binenbaum</name>
</author>
<author>
<name sortKey="Volpe, Nj" uniqKey="Volpe N">NJ Volpe</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Shah, J" uniqKey="Shah J">J Shah</name>
</author>
<author>
<name sortKey="Buckley, D" uniqKey="Buckley D">D Buckley</name>
</author>
<author>
<name sortKey="Frisby, J" uniqKey="Frisby J">J Frisby</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Rice, Ml" uniqKey="Rice M">ML Rice</name>
</author>
<author>
<name sortKey="Leske, Da" uniqKey="Leske D">DA Leske</name>
</author>
<author>
<name sortKey="Smestad, Ce" uniqKey="Smestad C">CE Smestad</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Schueneman, Al" uniqKey="Schueneman A">AL Schueneman</name>
</author>
<author>
<name sortKey="Pickleman, J" uniqKey="Pickleman J">J Pickleman</name>
</author>
<author>
<name sortKey="Freeark, Rj" uniqKey="Freeark R">RJ Freeark</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lynch, J" uniqKey="Lynch J">J Lynch</name>
</author>
<author>
<name sortKey="Aughwane, P" uniqKey="Aughwane P">P Aughwane</name>
</author>
<author>
<name sortKey="Hammond, Tm" uniqKey="Hammond T">TM Hammond</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Boyd, T" uniqKey="Boyd T">T Boyd</name>
</author>
<author>
<name sortKey="Jung, I" uniqKey="Jung I">I Jung</name>
</author>
<author>
<name sortKey="Van Sickle, K" uniqKey="Van Sickle K">K Van Sickle</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Br J Ophthalmol</journal-id>
<journal-id journal-id-type="iso-abbrev">Br J Ophthalmol</journal-id>
<journal-id journal-id-type="hwp">bjophthalmol</journal-id>
<journal-id journal-id-type="publisher-id">bjo</journal-id>
<journal-title-group>
<journal-title>The British Journal of Ophthalmology</journal-title>
</journal-title-group>
<issn pub-type="ppub">0007-1161</issn>
<issn pub-type="epub">1468-2079</issn>
<publisher>
<publisher-name>BMJ Publishing Group</publisher-name>
<publisher-loc>BMA House, Tavistock Square, London, WC1H 9JR</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">25185439</article-id>
<article-id pub-id-type="pmc">4316921</article-id>
<article-id pub-id-type="publisher-id">bjophthalmol-2013-304517</article-id>
<article-id pub-id-type="doi">10.1136/bjophthalmol-2013-304517</article-id>
<article-categories>
<subj-group subj-group-type="hwp-journal-coll">
<subject>1506</subject>
</subj-group>
<subj-group subj-group-type="heading">
<subject>Clinical Science</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>The effects of absence of stereopsis on performance of a simulated surgical task in two-dimensional and three-dimensional viewing conditions</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Bloch</surname>
<given-names>Edward</given-names>
</name>
<xref ref-type="aff" rid="af1">1</xref>
<xref ref-type="aff" rid="af2">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Uddin</surname>
<given-names>Nabil</given-names>
</name>
<xref ref-type="aff" rid="af1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gannon</surname>
<given-names>Laura</given-names>
</name>
<xref ref-type="aff" rid="af1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Rantell</surname>
<given-names>Khadija</given-names>
</name>
<xref ref-type="aff" rid="af3">3</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Jain</surname>
<given-names>Saurabh</given-names>
</name>
<xref ref-type="aff" rid="af1">1</xref>
<xref ref-type="aff" rid="af2">2</xref>
</contrib>
</contrib-group>
<aff id="af1">
<label>1</label>
<addr-line>Department of Ophthalmology</addr-line>
,
<institution>Royal Free London NHS Foundation Trust</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</aff>
<aff id="af2">
<label>2</label>
<institution>University College London Medical School</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</aff>
<aff id="af3">
<label>3</label>
<institution>Institute of Neurology, University College London</institution>
,
<addr-line>London</addr-line>
,
<country>UK</country>
</aff>
<author-notes>
<corresp>
<label>Correspondence to</label>
Saurabh Jain, Department of Ophthalmology, Royal Free Hospital, Pond Street, London NW3 2QG, UK;
<email>saurabh.jain@nhs.net</email>
</corresp>
<fn>
<p>EB and NU contributed equally and should be considered co-first authors.</p>
</fn>
</author-notes>
<pub-date pub-type="ppub">
<month>2</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>3</day>
<month>9</month>
<year>2014</year>
</pub-date>
<volume>99</volume>
<issue>2</issue>
<fpage>240</fpage>
<lpage>245</lpage>
<history>
<date date-type="received">
<day>22</day>
<month>10</month>
<year>2013</year>
</date>
<date date-type="rev-recd">
<day>20</day>
<month>7</month>
<year>2014</year>
</date>
<date date-type="accepted">
<day>8</day>
<month>8</month>
<year>2014</year>
</date>
</history>
<permissions>
<copyright-statement>Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions</copyright-statement>
<copyright-year>2015</copyright-year>
<license license-type="open-access">
<license-p>This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 3.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See:
<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">http://creativecommons.org/licenses/by-nc/3.0/</ext-link>
</license-p>
</license>
</permissions>
<self-uri xlink:title="pdf" xlink:type="simple" xlink:href="bjophthalmol-2013-304517.pdf"></self-uri>
<abstract>
<sec>
<title>Background</title>
<p>Stereopsis is believed to be advantageous for surgical tasks that require precise hand-eye coordination. We investigated the effects of short-term and long-term absence of stereopsis on motor task performance in three-dimensional (3D) and two-dimensional (2D) viewing conditions.</p>
</sec>
<sec>
<title>Methods</title>
<p>30 participants with normal stereopsis and 15 participants with absent stereopsis performed a simulated surgical task both in free space under direct vision (3D) and via a monitor (2D), with both eyes open and one eye covered in each condition.</p>
</sec>
<sec>
<title>Results</title>
<p>The stereo-normal group scored higher, on average, than the stereo-absent group with both eyes open under direct vision (p<0.001). Both groups performed comparably in monocular and binocular monitor viewing conditions (p=0.579).</p>
</sec>
<sec>
<title>Conclusions</title>
<p>High-grade stereopsis confers an advantage when performing a fine motor task under direct vision. However, stereopsis does not appear advantageous to task performance under 2D viewing conditions, such as in video-assisted surgery.</p>
</sec>
</abstract>
<kwd-group>
<kwd>Visual perception</kwd>
</kwd-group>
<custom-meta-group>
<custom-meta>
<meta-name>special-feature</meta-name>
<meta-value>unlocked</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>Stereopsis was first described in 1838 by Charles Wheatstone, the inventor of the stereoscope. He established that the human brain computes the disparities between images presented to each retina, giving rise to an inherent impression of solidity and relative depth.
<xref rid="R1" ref-type="bibr">1</xref>
It has been debated whether stereopsis is truly a functional necessity for humans; Fielder and Moseley suggest that it may well be beneficial for certain tasks involving complex visual presentations and hand-eye coordination.
<xref rid="R2" ref-type="bibr">2</xref>
</p>
<p>Minimally invasive surgery is used in various specialities, requiring a novel set of motor skills and adaptation to a different viewing condition. The three-dimensional (3D) operative field is magnified and displayed on a monitor, which provides a live two-dimensional (2D) video representation. This system prevents the use of stereopsis, forcing the surgeon to rely on other visual and haptic cues.</p>
<p>This study has been designed to demonstrate the effects of acute elimination and long-term absence of stereopsis on the performance of a fine motor task under different viewing conditions.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>Materials and methods</title>
<sec id="s2a">
<title>Participants</title>
<p>A total of 45 participants, were recruited into the study from the University College London Medical School, the Royal Free and the Whittington hospitals. Two-thirds (30/45) of the participants were stereo-normal, and the remainder (15/45) were stereo-absent. Inclusion criteria required all participants to be aged 18–45 years, while those currently undergoing eye treatment and those with known motor or co-ordination problems were excluded.</p>
<p>Participant clinical and ophthalmic history, including the pre-existence of any conditions affecting balance or coordination, was ascertained at screening by a clinician using a questionnaire designed for this study. This included questions regarding experience that may affect dexterity (such as video games and musical instruments). No participant had had any formal minimally invasive surgical training. Participants were unaware of the other test group, and information was limited to reduce demand characteristics.</p>
<p>All participants underwent orthoptic assessment, including best corrected visual acuities (recorded with an ETDRS chart at 6 m and reduced Snellen at 33 cm), ocular alignment, ocular motility, convergence and assessment of sensory and motor fusion. Stereoacuity was measured to threshold using the Frisby Near Stereotest or Wirt Fly Stereotest for detection of the coarsest stereoacuity possible in clinic (3600 s of arc) Laterality of the dominant eye was determined from visual acuities and objective assessment of convergence using a Royal Air Force rule. In the stereo-normal group, participants were required to have best corrected visual acuities of 0.200 logMAR (6/9.5 Snellen equivalent) or better in both eyes, convergence of within 12 cm, fusional amplitudes of more than 25BO to 10BI for near, and 12BO to 4BI for distance, and stereopsis of at least 55″ arc.
<xref rid="R3" ref-type="bibr">3</xref>
In the stereo-absent group, participants were required to have a best corrected visual acuity of 0.200 logMAR (6/9.5) or better from at least one eye, the presence of suppression for near and distance (ie, no demonstrable sensory fusion using worth lights) and an absence of stereopsis (
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB1">table 1</xref>
).</p>
<table-wrap id="BJOPHTHALMOL2013304517TB1" position="float">
<label>Table 1</label>
<caption>
<p>Characteristics of the stereo-absent participant group</p>
</caption>
<table frame="hsides" rules="groups">
<colgroup span="1">
<col align="left" span="1"></col>
<col align="left" span="1"></col>
<col align="left" span="1"></col>
<col align="left" span="1"></col>
<col align="left" span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="left" span="1"></col>
<col align="left" span="1"></col>
<col align="left" span="1"></col>
</colgroup>
<thead valign="bottom">
<tr>
<th rowspan="1" colspan="1"></th>
<th rowspan="1" colspan="1"></th>
<th rowspan="1" colspan="1"></th>
<th rowspan="1" colspan="1"></th>
<th rowspan="1" colspan="1"></th>
<th align="left" colspan="3" rowspan="1">Best corrected visual acuity (LogMAR)</th>
<th rowspan="1" colspan="1"></th>
<th rowspan="1" colspan="1"></th>
<th rowspan="1" colspan="1"></th>
</tr>
<tr>
<th align="left" rowspan="1" colspan="1">Part.</th>
<th align="left" rowspan="1" colspan="1">Age</th>
<th align="left" rowspan="1" colspan="1">Deviation (all constant manifest strabismus)</th>
<th align="left" rowspan="1" colspan="1">Near angle</th>
<th align="left" rowspan="1" colspan="1">Distance angle</th>
<th align="left" rowspan="1" colspan="1">Both eyes open</th>
<th align="left" rowspan="1" colspan="1">Right eye</th>
<th align="left" rowspan="1" colspan="1">Left eye</th>
<th align="left" rowspan="1" colspan="1">Dominant eye</th>
<th align="left" rowspan="1" colspan="1">Suppression</th>
<th align="left" rowspan="1" colspan="1">Additional information</th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="1" colspan="1">1</td>
<td rowspan="1" colspan="1">27</td>
<td rowspan="1" colspan="1">Right to alternating exotropia</td>
<td rowspan="1" colspan="1">n/a</td>
<td rowspan="1" colspan="1">n/a</td>
<td rowspan="1" colspan="1">0.200</td>
<td rowspan="1" colspan="1">0.220</td>
<td rowspan="1" colspan="1">0.340</td>
<td rowspan="1" colspan="1">Left*</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1">Myopia, X pattern</td>
</tr>
<tr>
<td rowspan="1" colspan="1">2</td>
<td rowspan="1" colspan="1">36</td>
<td rowspan="1" colspan="1">Exotropia</td>
<td rowspan="1" colspan="1">10ΔBI</td>
<td rowspan="1" colspan="1">10ΔBI</td>
<td rowspan="1" colspan="1">−0.040</td>
<td rowspan="1" colspan="1">−0.040</td>
<td rowspan="1" colspan="1">0.040</td>
<td rowspan="1" colspan="1">Right</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1"></td>
</tr>
<tr>
<td rowspan="1" colspan="1">3</td>
<td rowspan="1" colspan="1">34</td>
<td rowspan="1" colspan="1">Residual exotropia</td>
<td rowspan="1" colspan="1">4ΔBI</td>
<td rowspan="1" colspan="1">4ΔBI</td>
<td rowspan="1" colspan="1">0.200</td>
<td rowspan="1" colspan="1">0.220</td>
<td rowspan="1" colspan="1">1.600</td>
<td rowspan="1" colspan="1">Right</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1">Right eye aphakia</td>
</tr>
<tr>
<td rowspan="1" colspan="1">4</td>
<td rowspan="1" colspan="1">34</td>
<td rowspan="1" colspan="1">Consecutive exotropia</td>
<td rowspan="1" colspan="1">12ΔBI</td>
<td rowspan="1" colspan="1">14ΔBI</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">0.120</td>
<td rowspan="1" colspan="1">0.020</td>
<td rowspan="1" colspan="1">Left</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1"></td>
</tr>
<tr>
<td rowspan="1" colspan="1">5</td>
<td rowspan="1" colspan="1">35</td>
<td rowspan="1" colspan="1">Sensory exotropia</td>
<td rowspan="1" colspan="1">8ΔBI</td>
<td rowspan="1" colspan="1">8ΔBI</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">1.300</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">Left</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1"></td>
</tr>
<tr>
<td rowspan="1" colspan="1">6</td>
<td rowspan="1" colspan="1">26</td>
<td rowspan="1" colspan="1">Exotropia</td>
<td rowspan="1" colspan="1">45ΔBI</td>
<td rowspan="1" colspan="1">45ΔBI</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">0.040</td>
<td rowspan="1" colspan="1">0.800</td>
<td rowspan="1" colspan="1">Right</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1"></td>
</tr>
<tr>
<td rowspan="1" colspan="1">7</td>
<td rowspan="1" colspan="1">42</td>
<td rowspan="1" colspan="1">Exotropia</td>
<td rowspan="1" colspan="1">40ΔBI</td>
<td rowspan="1" colspan="1">38ΔBI</td>
<td rowspan="1" colspan="1">−0.200</td>
<td rowspan="1" colspan="1">−0.100</td>
<td rowspan="1" colspan="1">1.040</td>
<td rowspan="1" colspan="1">Right</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1"></td>
</tr>
<tr>
<td rowspan="1" colspan="1">8</td>
<td rowspan="1" colspan="1">37</td>
<td rowspan="1" colspan="1">Alternating L/R</td>
<td rowspan="1" colspan="1">25ΔL/R</td>
<td rowspan="1" colspan="1">20ΔL/R</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">Left</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1">Left 4th nerve palsy</td>
</tr>
<tr>
<td rowspan="1" colspan="1">9</td>
<td rowspan="1" colspan="1">23</td>
<td rowspan="1" colspan="1">Left to alternating exotropia</td>
<td rowspan="1" colspan="1">40ΔBI</td>
<td rowspan="1" colspan="1">45ΔBI</td>
<td rowspan="1" colspan="1">0.060</td>
<td rowspan="1" colspan="1">0.100</td>
<td rowspan="1" colspan="1">0.320</td>
<td rowspan="1" colspan="1">Right</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1">Dissociated vertical deviation, no manifest latent nystagmus</td>
</tr>
<tr>
<td rowspan="1" colspan="1">10</td>
<td rowspan="1" colspan="1">23</td>
<td rowspan="1" colspan="1">Sensory residual exotropia and R hypotropia</td>
<td rowspan="1" colspan="1">4ΔBI and 5ΔL/R</td>
<td rowspan="1" colspan="1">2ΔBI and 6ΔL/R</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">1.040</td>
<td rowspan="1" colspan="1">0.000</td>
<td rowspan="1" colspan="1">Left</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1">Superior rectus underaction</td>
</tr>
<tr>
<td rowspan="1" colspan="1">11</td>
<td rowspan="1" colspan="1">38</td>
<td rowspan="1" colspan="1">Sensory exotropia</td>
<td rowspan="1" colspan="1">30ΔBI</td>
<td rowspan="1" colspan="1">30ΔBI</td>
<td rowspan="1" colspan="1">0.040</td>
<td rowspan="1" colspan="1">1.000</td>
<td rowspan="1" colspan="1">0.120</td>
<td rowspan="1" colspan="1">Left</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1">Y pattern, bilateral inferior oblique overaction</td>
</tr>
<tr>
<td rowspan="1" colspan="1">12</td>
<td rowspan="1" colspan="1">21</td>
<td rowspan="1" colspan="1">Exotropia and L hypertropia</td>
<td rowspan="1" colspan="1">25ΔBI and 2ΔL/R</td>
<td rowspan="1" colspan="1">30ΔBI and 2ΔL/R</td>
<td rowspan="1" colspan="1">0.200</td>
<td rowspan="1" colspan="1">0.200</td>
<td rowspan="1" colspan="1">CF</td>
<td rowspan="1" colspan="1">Right</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1">Y pattern, pseudophakia</td>
</tr>
<tr>
<td rowspan="1" colspan="1">13</td>
<td rowspan="1" colspan="1">24</td>
<td rowspan="1" colspan="1">Esotropia</td>
<td rowspan="1" colspan="1">14ΔBO</td>
<td rowspan="1" colspan="1">16ΔB)</td>
<td rowspan="1" colspan="1">−0.080</td>
<td rowspan="1" colspan="1">−0.080</td>
<td rowspan="1" colspan="1">0.100</td>
<td rowspan="1" colspan="1">Right</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1"></td>
</tr>
<tr>
<td rowspan="1" colspan="1">14</td>
<td rowspan="1" colspan="1">26</td>
<td rowspan="1" colspan="1">Esotropia</td>
<td rowspan="1" colspan="1">10ΔBO</td>
<td rowspan="1" colspan="1">8ΔBO</td>
<td rowspan="1" colspan="1">−0.100</td>
<td rowspan="1" colspan="1">0.080</td>
<td rowspan="1" colspan="1">−0.100</td>
<td rowspan="1" colspan="1">Left</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1"></td>
</tr>
<tr>
<td rowspan="1" colspan="1">15</td>
<td rowspan="1" colspan="1">25</td>
<td rowspan="1" colspan="1">Exotropia</td>
<td rowspan="1" colspan="1">14ΔBI</td>
<td rowspan="1" colspan="1">10ΔBI</td>
<td rowspan="1" colspan="1">−0.100</td>
<td rowspan="1" colspan="1">−0.060</td>
<td rowspan="1" colspan="1">−0.060</td>
<td rowspan="1" colspan="1">Right</td>
<td rowspan="1" colspan="1">Yes</td>
<td rowspan="1" colspan="1"></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>*Participant 1 preferred left fixation at near, and right fixation for distance.</p>
</fn>
<fn>
<p>CF, counting fingers; n/a, not applicable.</p>
</fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="s2b">
<title>Task</title>
<p>The participants performed a ‘pea-on-a-peg’ motor skills task which involved placing small plastic balls on columns of various heights using laparoscopic graspers (
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F1">figure 1</xref>
). Performance was quantified according to the number of balls placed in the allotted time. The order of ball placement was prespecified to prevent strategy.</p>
<fig id="BJOPHTHALMOL2013304517F1" position="float">
<label>Figure 1</label>
<caption>
<p>The ‘pea-on-a-peg’ task.</p>
</caption>
<graphic xlink:href="bjophthalmol-2013-304517f01"></graphic>
</fig>
<p>The task was performed under direct vision and via a monitor, part of a laparoscopic ‘box trainer’ simulation machine (
<italic>3Dmed</italic>
Minimally Invasive Training System (
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F2">figures 2</xref>
and
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F3">3</xref>
)). Each condition was repeated with both eyes open and one eye occluded. The order of the four test conditions was randomised, with three attempts of 50 s allowed for each. Monocular conditions were established by occluding the non-dominant eye with an opaque patch, and participants wore refractive correction where necessary. Both the box trainer and the ‘pea-on-a-peg’ task are validated methods for simulated laparoscopy skills training.
<xref rid="R4" ref-type="bibr">4</xref>
</p>
<fig id="BJOPHTHALMOL2013304517F2" position="float">
<label>Figure 2</label>
<caption>
<p>3D med Minimally Invasive Training System.</p>
</caption>
<graphic xlink:href="bjophthalmol-2013-304517f02"></graphic>
</fig>
<fig id="BJOPHTHALMOL2013304517F3" position="float">
<label>Figure 3</label>
<caption>
<p>3D med Minimally Invasive Training System.</p>
</caption>
<graphic xlink:href="bjophthalmol-2013-304517f03"></graphic>
</fig>
<p>A pilot study of 10 participants revealed that there is, as expected, an element of improvement in performance with practice. We expected this and have attempted to control for it by establishing an optimal familiarisation period (5 min) to minimise the confounding effects of initial improvement.</p>
</sec>
<sec id="s2c">
<title>Statistical analysis</title>
<p>Numerical data were summarised using mean and SD or median and range, depending on data distribution. Categorical data were summarised using count and percentages. The relationship between the performance of fine motor task and stereopsis was assessed using a multilevel linear regression model with participants as random effect, and group as fixed effects.
<xref rid="R5" ref-type="bibr">5</xref>
The multilevel model takes into account the correlation structure of the data, providing estimates of effects and their 95% CI. The data were analysed using Stata V.13 (SPSS statistics).</p>
<p>Informed consent was obtained, and the research protocol was approved by the Camberwell St Giles Research Ethics Committee observing the tenets of the Declaration of Helsinki.</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>Results</title>
<p>Thirty stereo-normal participants with a mean age of 27.0 years and a female to male ratio 1:2 were recruited into the control group. Fifteen stereo-absent participants were recruited into the study group, with a mean age of 30.1 years, and female to male ratio 7:8. All participants in this group had manifest strabismus (see
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB1">table 1</xref>
).</p>
<p>It was found that, in free space under direct (3D) viewing conditions, the stereo-normal group (average stereoacuity of 37.7″) placed more balls on average (± SEM) with both eyes open (12.1±0.30) compared with one eye occluded (9.9±0.44) in the allocated time of 50 s (
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB2">table 2</xref>
). The estimated difference of means was 2.22 (95% CI 1.46 to 2.98) and p<0.001 (
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB3">table 3</xref>
).</p>
<table-wrap id="BJOPHTHALMOL2013304517TB2" position="float">
<label>Table 2</label>
<caption>
<p>Stereo-normal group results</p>
</caption>
<table frame="hsides" rules="groups">
<colgroup span="1">
<col align="left" span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
</colgroup>
<thead valign="bottom">
<tr>
<th align="left" rowspan="3" colspan="1">Stereo-normal participant</th>
<th align="left" colspan="4" rowspan="1">Number of balls in 50 s (mean of 3 attempts)</th>
</tr>
<tr>
<th align="left" colspan="2" rowspan="1">Free space</th>
<th align="left" colspan="2" rowspan="1">Monitor</th>
</tr>
<tr>
<th align="left" rowspan="1" colspan="1">Both eyes</th>
<th align="left" rowspan="1" colspan="1">One eye</th>
<th align="left" rowspan="1" colspan="1">Both eyes</th>
<th align="left" rowspan="1" colspan="1">One eye</th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="1" colspan="1">1</td>
<td rowspan="1" colspan="1">13.33</td>
<td rowspan="1" colspan="1">11.00</td>
<td rowspan="1" colspan="1">5.67</td>
<td rowspan="1" colspan="1">6.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">2</td>
<td rowspan="1" colspan="1">13.33</td>
<td rowspan="1" colspan="1">10.00</td>
<td rowspan="1" colspan="1">6.33</td>
<td rowspan="1" colspan="1">5.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">3</td>
<td rowspan="1" colspan="1">11.33</td>
<td rowspan="1" colspan="1">12.00</td>
<td rowspan="1" colspan="1">8.33</td>
<td rowspan="1" colspan="1">6.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">4</td>
<td rowspan="1" colspan="1">12.00</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">4.67</td>
<td rowspan="1" colspan="1">4.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">5</td>
<td rowspan="1" colspan="1">11.33</td>
<td rowspan="1" colspan="1">5.33</td>
<td rowspan="1" colspan="1">7.00</td>
<td rowspan="1" colspan="1">6.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">6</td>
<td rowspan="1" colspan="1">9.00</td>
<td rowspan="1" colspan="1">4.67</td>
<td rowspan="1" colspan="1">3.33</td>
<td rowspan="1" colspan="1">6.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">7</td>
<td rowspan="1" colspan="1">9.67</td>
<td rowspan="1" colspan="1">9.33</td>
<td rowspan="1" colspan="1">7.67</td>
<td rowspan="1" colspan="1">5.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">8</td>
<td rowspan="1" colspan="1">12.00</td>
<td rowspan="1" colspan="1">11.33</td>
<td rowspan="1" colspan="1">3.67</td>
<td rowspan="1" colspan="1">7.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">9</td>
<td rowspan="1" colspan="1">12.67</td>
<td rowspan="1" colspan="1">13.00</td>
<td rowspan="1" colspan="1">10.00</td>
<td rowspan="1" colspan="1">8.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">10</td>
<td rowspan="1" colspan="1">10.33</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">4.33</td>
<td rowspan="1" colspan="1">5.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">11</td>
<td rowspan="1" colspan="1">13.00</td>
<td rowspan="1" colspan="1">10.33</td>
<td rowspan="1" colspan="1">8.33</td>
<td rowspan="1" colspan="1">8.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">12</td>
<td rowspan="1" colspan="1">12.00</td>
<td rowspan="1" colspan="1">8.67</td>
<td rowspan="1" colspan="1">2.67</td>
<td rowspan="1" colspan="1">4.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">13</td>
<td rowspan="1" colspan="1">10.00</td>
<td rowspan="1" colspan="1">8.33</td>
<td rowspan="1" colspan="1">7.00</td>
<td rowspan="1" colspan="1">7.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">14</td>
<td rowspan="1" colspan="1">13.33</td>
<td rowspan="1" colspan="1">10.67</td>
<td rowspan="1" colspan="1">7.67</td>
<td rowspan="1" colspan="1">7.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">15</td>
<td rowspan="1" colspan="1">10.33</td>
<td rowspan="1" colspan="1">5.67</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">5.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">16</td>
<td rowspan="1" colspan="1">13.33</td>
<td rowspan="1" colspan="1">12.33</td>
<td rowspan="1" colspan="1">8.00</td>
<td rowspan="1" colspan="1">5.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">17</td>
<td rowspan="1" colspan="1">16.00</td>
<td rowspan="1" colspan="1">14.33</td>
<td rowspan="1" colspan="1">10.33</td>
<td rowspan="1" colspan="1">8.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">18</td>
<td rowspan="1" colspan="1">12.33</td>
<td rowspan="1" colspan="1">10.33</td>
<td rowspan="1" colspan="1">7.00</td>
<td rowspan="1" colspan="1">6.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">19</td>
<td rowspan="1" colspan="1">15.00</td>
<td rowspan="1" colspan="1">10.67</td>
<td rowspan="1" colspan="1">5.33</td>
<td rowspan="1" colspan="1">6.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">20</td>
<td rowspan="1" colspan="1">14.00</td>
<td rowspan="1" colspan="1">11.00</td>
<td rowspan="1" colspan="1">6.00</td>
<td rowspan="1" colspan="1">1.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">21</td>
<td rowspan="1" colspan="1">11.00</td>
<td rowspan="1" colspan="1">10.33</td>
<td rowspan="1" colspan="1">4.33</td>
<td rowspan="1" colspan="1">4.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">22</td>
<td rowspan="1" colspan="1">9.33</td>
<td rowspan="1" colspan="1">11.00</td>
<td rowspan="1" colspan="1">6.00</td>
<td rowspan="1" colspan="1">6.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">23</td>
<td rowspan="1" colspan="1">12.67</td>
<td rowspan="1" colspan="1">7.00</td>
<td rowspan="1" colspan="1">9.33</td>
<td rowspan="1" colspan="1">9.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">24</td>
<td rowspan="1" colspan="1">11.33</td>
<td rowspan="1" colspan="1">8.33</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">6.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">25</td>
<td rowspan="1" colspan="1">13.33</td>
<td rowspan="1" colspan="1">10.33</td>
<td rowspan="1" colspan="1">9.00</td>
<td rowspan="1" colspan="1">8.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">26</td>
<td rowspan="1" colspan="1">11.00</td>
<td rowspan="1" colspan="1">9.67</td>
<td rowspan="1" colspan="1">3.00</td>
<td rowspan="1" colspan="1">3.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">27</td>
<td rowspan="1" colspan="1">14.00</td>
<td rowspan="1" colspan="1">13.67</td>
<td rowspan="1" colspan="1">7.67</td>
<td rowspan="1" colspan="1">7.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">28</td>
<td rowspan="1" colspan="1">12.67</td>
<td rowspan="1" colspan="1">9.33</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">7.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">29</td>
<td rowspan="1" colspan="1">12.00</td>
<td rowspan="1" colspan="1">10.67</td>
<td rowspan="1" colspan="1">5.00</td>
<td rowspan="1" colspan="1">8.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">30</td>
<td rowspan="1" colspan="1">12.00</td>
<td rowspan="1" colspan="1">13.00</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">7.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">Mean</td>
<td rowspan="1" colspan="1">12.12</td>
<td rowspan="1" colspan="1">9.90</td>
<td rowspan="1" colspan="1">6.57</td>
<td rowspan="1" colspan="1">6.34</td>
</tr>
<tr>
<td rowspan="1" colspan="1">SEM</td>
<td rowspan="1" colspan="1">0.30</td>
<td rowspan="1" colspan="1">0.44</td>
<td rowspan="1" colspan="1">0.37</td>
<td rowspan="1" colspan="1">0.32</td>
</tr>
</tbody>
</table>
</table-wrap>
<table-wrap id="BJOPHTHALMOL2013304517TB3" position="float">
<label>Table 3</label>
<caption>
<p>Multilevel model posthoc pairwise and three-way analysis</p>
</caption>
<table frame="hsides" rules="groups">
<colgroup span="1">
<col align="left" span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
</colgroup>
<thead valign="bottom">
<tr>
<th align="left" rowspan="1" colspan="1">Comparison</th>
<th align="left" rowspan="1" colspan="1">Estimated difference of means</th>
<th align="left" colspan="2" rowspan="1">95% CI</th>
<th align="left" rowspan="1" colspan="1">SEM</th>
<th align="left" rowspan="1" colspan="1">p Value</th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="1" colspan="1">Stereo-normal free space binocular vs monocular</td>
<td rowspan="1" colspan="1">2.22</td>
<td rowspan="1" colspan="1">1.46</td>
<td rowspan="1" colspan="1">2.98</td>
<td rowspan="1" colspan="1">0.39</td>
<td rowspan="1" colspan="1"><0.001</td>
</tr>
<tr>
<td rowspan="1" colspan="1">Stereo-absent free space binocular vs monocular</td>
<td rowspan="1" colspan="1">0.62</td>
<td rowspan="1" colspan="1">−0.45</td>
<td rowspan="1" colspan="1">1.70</td>
<td rowspan="1" colspan="1">0.55</td>
<td rowspan="1" colspan="1">0.260</td>
</tr>
<tr>
<td rowspan="1" colspan="1">Stereo-normal free space binocular vs stereo-absent free space binocular</td>
<td rowspan="1" colspan="1">3.03</td>
<td rowspan="1" colspan="1">1.84</td>
<td rowspan="1" colspan="1">4.22</td>
<td rowspan="1" colspan="1">0.61</td>
<td rowspan="1" colspan="1"><0.001</td>
</tr>
<tr>
<td rowspan="1" colspan="1">Stereo-normal free space monocular vs stereo-absent free space monocular</td>
<td rowspan="1" colspan="1">1.43</td>
<td rowspan="1" colspan="1">0.24</td>
<td rowspan="1" colspan="1">2.62</td>
<td rowspan="1" colspan="1">0.61</td>
<td rowspan="1" colspan="1">0.018</td>
</tr>
<tr>
<td rowspan="1" colspan="1">Stereo-normal monitor vs stereo-absent monitor</td>
<td rowspan="1" colspan="1">0.29</td>
<td rowspan="1" colspan="1">−0.70</td>
<td rowspan="1" colspan="1">1.28</td>
<td rowspan="1" colspan="1">0.51</td>
<td rowspan="1" colspan="1">0.579</td>
</tr>
<tr>
<td rowspan="1" colspan="1">Stereo-normal free space vs monitor</td>
<td rowspan="1" colspan="1">4.56</td>
<td rowspan="1" colspan="1">4.02</td>
<td rowspan="1" colspan="1">5.09</td>
<td rowspan="1" colspan="1">0.27</td>
<td rowspan="1" colspan="1"><0.001</td>
</tr>
<tr>
<td rowspan="1" colspan="1">Stereo-absent free space vs monitor</td>
<td rowspan="1" colspan="1">2.61</td>
<td rowspan="1" colspan="1">1.85</td>
<td rowspan="1" colspan="1">3.37</td>
<td rowspan="1" colspan="1">0.39</td>
<td rowspan="1" colspan="1"><0.001</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>In the same condition, the stereo-absent group placed an average of 9.1±0.50 balls with both eyes open, compared with 8.5±0.55 balls with one eye occluded (
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB4">table 4</xref>
). The estimated difference of means was 0.622 (95% CI −0.45 to 1.70) and p=0.260.</p>
<table-wrap id="BJOPHTHALMOL2013304517TB4" position="float">
<label>Table 4</label>
<caption>
<p>Stereo-absent group results</p>
</caption>
<table frame="hsides" rules="groups">
<colgroup span="1">
<col align="left" span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
<col align="char" char="." span="1"></col>
</colgroup>
<thead valign="bottom">
<tr>
<th align="left" rowspan="3" colspan="1">Stereo-absent participant</th>
<th align="left" colspan="4" rowspan="1">Number of balls in 50 s (mean of 3 attempts)</th>
</tr>
<tr>
<th align="left" colspan="2" rowspan="1">Free space</th>
<th align="left" colspan="2" rowspan="1">Monitor</th>
</tr>
<tr>
<th align="left" rowspan="1" colspan="1">Both eyes</th>
<th align="left" rowspan="1" colspan="1">One eye</th>
<th align="left" rowspan="1" colspan="1">Both eyes</th>
<th align="left" rowspan="1" colspan="1">One eye</th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="1" colspan="1">1</td>
<td rowspan="1" colspan="1">12.00</td>
<td rowspan="1" colspan="1">11.00</td>
<td rowspan="1" colspan="1">6.33</td>
<td rowspan="1" colspan="1">6.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">2</td>
<td rowspan="1" colspan="1">12.33</td>
<td rowspan="1" colspan="1">13.00</td>
<td rowspan="1" colspan="1">5.67</td>
<td rowspan="1" colspan="1">8.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">3</td>
<td rowspan="1" colspan="1">5.33</td>
<td rowspan="1" colspan="1">6.67</td>
<td rowspan="1" colspan="1">2.00</td>
<td rowspan="1" colspan="1">3.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">4</td>
<td rowspan="1" colspan="1">10.67</td>
<td rowspan="1" colspan="1">9.67</td>
<td rowspan="1" colspan="1">7.67</td>
<td rowspan="1" colspan="1">7.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">5</td>
<td rowspan="1" colspan="1">7.00</td>
<td rowspan="1" colspan="1">4.67</td>
<td rowspan="1" colspan="1">6.00</td>
<td rowspan="1" colspan="1">7.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">6</td>
<td rowspan="1" colspan="1">9.33</td>
<td rowspan="1" colspan="1">9.33</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">7.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">7</td>
<td rowspan="1" colspan="1">7.67</td>
<td rowspan="1" colspan="1">9.67</td>
<td rowspan="1" colspan="1">6.00</td>
<td rowspan="1" colspan="1">7.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">8</td>
<td rowspan="1" colspan="1">10.00</td>
<td rowspan="1" colspan="1">6.00</td>
<td rowspan="1" colspan="1">5.00</td>
<td rowspan="1" colspan="1">4.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">9</td>
<td rowspan="1" colspan="1">8.67</td>
<td rowspan="1" colspan="1">8.33</td>
<td rowspan="1" colspan="1">2.33</td>
<td rowspan="1" colspan="1">3.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">10</td>
<td rowspan="1" colspan="1">10.67</td>
<td rowspan="1" colspan="1">10.00</td>
<td rowspan="1" colspan="1">6.00</td>
<td rowspan="1" colspan="1">8.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">11</td>
<td rowspan="1" colspan="1">8.00</td>
<td rowspan="1" colspan="1">7.67</td>
<td rowspan="1" colspan="1">5.67</td>
<td rowspan="1" colspan="1">6.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">12</td>
<td rowspan="1" colspan="1">8.33</td>
<td rowspan="1" colspan="1">7.00</td>
<td rowspan="1" colspan="1">6.33</td>
<td rowspan="1" colspan="1">5.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">13</td>
<td rowspan="1" colspan="1">7.00</td>
<td rowspan="1" colspan="1">9.33</td>
<td rowspan="1" colspan="1">6.33</td>
<td rowspan="1" colspan="1">7.00</td>
</tr>
<tr>
<td rowspan="1" colspan="1">14</td>
<td rowspan="1" colspan="1">10.33</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">9.00</td>
<td rowspan="1" colspan="1">6.33</td>
</tr>
<tr>
<td rowspan="1" colspan="1">15</td>
<td rowspan="1" colspan="1">9.00</td>
<td rowspan="1" colspan="1">7.33</td>
<td rowspan="1" colspan="1">8.67</td>
<td rowspan="1" colspan="1">6.67</td>
</tr>
<tr>
<td rowspan="1" colspan="1">Mean</td>
<td rowspan="1" colspan="1">9.09</td>
<td rowspan="1" colspan="1">8.47</td>
<td rowspan="1" colspan="1">6.02</td>
<td rowspan="1" colspan="1">6.31</td>
</tr>
<tr>
<td rowspan="1" colspan="1">SEM</td>
<td rowspan="1" colspan="1">0.50</td>
<td rowspan="1" colspan="1">0.55</td>
<td rowspan="1" colspan="1">0.50</td>
<td rowspan="1" colspan="1">0.44</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The stereo-normal group performed significantly better than the stereo-absent group under binocular direct vision with an estimated difference between group means of 3.03 (95% CI 1.84 to 4.22) and p<0.001. The performance of the stereo-normal group under monocular conditions was also better compared to that of the stereo-absent group, with an estimated difference of means of 1.43 (95% CI 0.24 to 2.62) and a p=0.018 (
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F4">figure 4</xref>
).</p>
<fig id="BJOPHTHALMOL2013304517F4" position="float">
<label>Figure 4</label>
<caption>
<p>Task performance in free space (under direct vision). Median (squares), 1st–3rd quartile (boxes) and minimum/maximum (error bars).</p>
</caption>
<graphic xlink:href="bjophthalmol-2013-304517f04"></graphic>
</fig>
<p>Under monitor (2D) viewing conditions, we found no statistical difference in average number of balls placed within or between groups. Pairwise comparison within the multilevel model demonstrated that stereo-normal group performance with both and one eye open (6.6±0.37 and 6.3±0.32 balls, respectively) was comparable to that of the stereo-absent group (6.0±0.50 and 6.3±0.44 balls), with an estimated difference of means of 0.29 (95% CI −0.70 to 1.28) and p=0.579 (
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F5">figure 5</xref>
,
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB3">table 3</xref>
).</p>
<fig id="BJOPHTHALMOL2013304517F5" position="float">
<label>Figure 5</label>
<caption>
<p>Task performance under monitor vision. Median (squares), 1st–3rd quartile (boxes) and minimum/maximum (error bars).</p>
</caption>
<graphic xlink:href="bjophthalmol-2013-304517f05"></graphic>
</fig>
</sec>
<sec sec-type="discussion" id="s4">
<title>Discussion</title>
<p>Stereopsis is the perception of depth achieved by the analysis of the relative disparity of images elements projected onto the two retinae.
<xref rid="R1" ref-type="bibr">1</xref>
<xref rid="R6" ref-type="bibr">6</xref>
However, our visual perception of an object's distance also varies according to its size, shape and shading, which constitute monocular cues. Object interposition, relative distortion and the phenomenon of motion parallax also allows for appreciation of depth.
<xref rid="R7" ref-type="bibr">7</xref>
<xref rid="R8" ref-type="bibr">8</xref>
In summary, although true stereopsis is only possible with binocular vision, indirect appreciation of a 3D world is feasible through innate interpretation of monocular and motor cues.</p>
<sec id="s4a">
<title>Direct vision</title>
<p>Our results show that, in free space and under direct vision, participants with normal stereoacuity performed significantly better when using both eyes compared with one eye (
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F4">figure 4</xref>
). This finding is not surprising and is well reported in the literature. Studies involving simple prehensile and buzz-wire tasks have shown a binocular advantage in almost every indicator of performance for stereo-normal participants, concluding that there is a significant loss of visual information associated with monocular viewing.
<xref rid="R9" ref-type="bibr">9</xref>
<xref rid="R10" ref-type="bibr">10</xref>
</p>
<p>Within-group analysis of our data from participants with absent stereoacuity showed that they were not advantaged by having both eyes open when performing the task under direct vision (
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F4">figure 4</xref>
). Evidence from catching and grasping studies with one or both eyes open conditions suggest that stereo-deficient participants perform similarly under either viewing condition, while stereo-normal participants catch significantly more balls with both eyes open.
<xref rid="R11" ref-type="bibr">11</xref>
<xref rid="R12" ref-type="bibr">12</xref>
</p>
<p>Between-group analysis of our data reveals a significant advantage to the stereo-normal group, in free space with both eyes open, when compared with the stereo-absent group (
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F4">figure 4</xref>
). These findings are also consistent with studies that looked at various fine motor, grasping and basic surgical skills tasks, to compare performance of patients with amblyopia, strabismus or weak stereoacuity to that of stereo-normals.
<xref rid="R13" ref-type="bibr">13–16</xref>
Interestingly, there was evidence that the stereo-normal group free-space performance was also better than the stereo-absent group when one eye was occluded, although this trend was much less marked (
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB3">table 3</xref>
).</p>
<p>It is worth mentioning that these differences between the two groups could potentially be due to the issue of binocular rivalry. Since opaque occlusion was used, stereo-deficient participants may not have been affected the same way as the stereo group, since they have had long-term suppression.
<xref rid="R17" ref-type="bibr">17</xref>
</p>
<p>Various studies have considered the exact mechanisms of binocular advantage. Loftus
<italic>et al</italic>
suggest that the kinematic differences seen are a result of perceptual uncertainty. They conclude that, while binocularity does provide useful ‘on-line’ information during prehension, its removal will not necessarily affect performance in an environment where the brain is supplied with multiple other stimulus cues.
<xref rid="R18" ref-type="bibr">18</xref>
Bradshaw
<italic>et al</italic>
tested this by comparing task performance under binocular, monocular and biocular (identical views to each eye to remove disparity) conditions. They found that monocular and biocular conditions yielded similar performances, and concluded that deficits in monocular performance can be attributed to lack of local depth information specified by binocular disparity.
<xref rid="R19" ref-type="bibr">19</xref>
Our results concur with the latter, suggesting that binocular cues afforded by high-grade stereovision in the stereo-normal group convey a significant advantage to free-space task performance.</p>
<p>Traditionally, stereopsis has been considered essential to achieve surgical competence, with many training programmes, in particular, ophthalmology, requiring stereo testing at application.
<xref rid="R20" ref-type="bibr">20</xref>
There is evidence emerging from microsurgical simulation studies that suggests stereopsis may
<italic>not</italic>
be essential to achieve surgical competency in 3D conditions. Although stereo-deficient participants perform worse on average than their stereo-normal counterparts, there are several isolated exceptions to this trend (
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB4">table 4</xref>
) and, thus, the predictive validity of stereopsis and microsurgical performance remains unclear.
<xref rid="R21" ref-type="bibr">21</xref>
<xref rid="R22" ref-type="bibr">22</xref>
In 2006, Binenbaum and Volpe performed a national survey to assess surgical competency of ophthalmology residents. They found that, of residents reported to have difficulty mastering surgical skills due to poor hand-eye coordination and intraoperative judgement, almost all overcame these problems (with further training as required) and most (92%) became practising ophthalmologists, the majority of which (65%) were surgeons.
<xref rid="R23" ref-type="bibr">23</xref>
</p>
</sec>
<sec id="s4b">
<title>Monitor</title>
<p>We found that there is no statistically significant difference between stereo-normal and stereo-absent task performance using the monitor of a laparoscopy box trainer with either one or both eyes open (
<xref ref-type="fig" rid="BJOPHTHALMOL2013304517F5">figure 5</xref>
).</p>
<p>Modern surgery is becoming increasingly minimally invasive, and the operative field view is most frequently provided by a monitor that displays 2D images (as in laparoscopy), which may offer a more accessible route for stereo-deficient trainees pursuing a career in surgery. There is a paucity of evidence regarding the effects of absent stereopsis on surgical performance under 2D viewing conditions, and further study is needed to assess stereo-deficient trainee proficiency in minimally invasive surgery and, in particular, their ability to convert to open surgery where necessary.</p>
<p>We postulated that those participants with long-term absence of stereoacuity may demonstrate adaptations to the lack of binocularity, such as the development of enhanced sensitivity to monocular and proprioceptive cues. Using the ‘pea-on-a-peg’ task, we attempted to minimise haptic feedback and highlight any visual adaptations. There is reported evidence of long-term adaptation to absence of stereoacuity in bead-threading tasks,
<xref rid="R16" ref-type="bibr">16</xref>
however, it is worth noting that this task is much more reliant on proprioceptive feedback and, as such, may not represent enhanced interpretation of monocular visual cues. This idea is supported by Melmouth
<italic>et al</italic>
,
<xref rid="R12" ref-type="bibr">12</xref>
who report that participants with long-term stereo-deficiency demonstrated different grip application than stereo-normals, suggestive of adaptations in tactile and kinaesthetic feedback mechanisms. Interestingly, it has been reported that surgeons appear to adapt to the non-stereo viewing conditions of laparoscopy, and that greater reliance on stereopsis was a negative factor in their surgical performance.
<xref rid="R24" ref-type="bibr">24</xref>
However, our results did not suggest that the stereo-absent participants had developed an enhanced assimilation of monocular or motor visual cues, and it is possible that the apparent adaptations seen in surgeons are, in fact, a result of equipment familiarity and superior proprioceptive feedback.</p>
<p>In each viewing condition, average task performance under direct vision was better than the equivalent condition on the monitor. In the stereo-normal group, the estimated difference of means from free space to monitor was 4.56 (95% CI 4.02 to 5.09), while that of the stereo-absent group was 2.61 (95% CI 1.85 to 3.37), in both cases p<0.001 (
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB3">table 3</xref>
). This suggests that the monitor condition represents more than just a loss of binocular disparity. Gallagher
<italic>et al</italic>
, looked at three groups’ performance of a simple cutting task either under binocular direct vision, monocular direct vision or via a monitor. They reported a binocular advantage, as expected, but also showed that monocular performance was significantly better than monitor performance, due to the poorer image quality provided by the monitor, thus diminishing the monocular cues.
<xref rid="R8" ref-type="bibr">8</xref>
These results are in keeping with our data, and the significant deterioration in performance from direct vision to monitor conditions may result from relative degradation of image quality or simply be a consequence of the unfamiliar and restrictive environment afforded by the box trainer.</p>
<p>Despite attempts to prevent confounding, there are limitations to our study. With regards to testing ocular dominance, results can vary depending on the test.
<xref rid="R25" ref-type="bibr">25</xref>
It should also be noted that three of the 15 stereo-absent participants (20%) had an alternating manifest strabismus, and hand-eye coordination may have been affected if alternation occurred during task performance with both eyes open (
<xref ref-type="table" rid="BJOPHTHALMOL2013304517TB1">table 1</xref>
).</p>
<p>Additionally, some stereo-deficient participants were insightful of the fact that their hand-eye coordination might be reduced. The mere knowledge of having strabismus may have induced demand characteristics in this group.</p>
<p>Some studies have suggested that laparoscopy operative skill is related to age, gender, lateral dominance, video-game and musical instrument experience.
<xref rid="R26" ref-type="bibr">26–28</xref>
While these may serve as confounding variables that influence subject performance, they were not factored in during our experimental design, and further study with careful quantification and control of variables is necessary.</p>
<p>In summary, we found that stereo-absent participants’ performance on a 2D video-assisted surgical system is equivalent to that of their stereo-normal counterparts. As expected, we also found that stereo-absent participants perform significantly worse, on average, than stereo-normals in free space. However, we noted several cases where the degree of stereopsis did
<italic>not</italic>
correlate with task performance in free space with both eyes open. It is likely that surgical trainees with absent stereoacuity can achieve acceptable levels of surgical competence in minimally invasive surgery. Given the lack of a conclusive correlation between stereoacuity and surgical competence, we would not advocate the use of a stereopsis screening tool to predict technical aptitude in surgical trainees.</p>
</sec>
</sec>
</body>
<back>
<ack>
<p>Mr Bimbi Fernando and Mr Pasquale Berlingieri for their assistance with the simulation equipment and facilities. Dr John Hurst, Miss Anna Maino and the UCL Statistics Department for assistance in study design and data analysis.</p>
</ack>
<fn-group>
<fn>
<p>
<bold>Contributors:</bold>
Conception and design: SJ, NU, EB and LG. Data collection: EB, NU and LG. Analysis and interpretation: EB, NU and KR. Preparation: EB, NU, KR and SJ. Supervision: SJ.</p>
</fn>
<fn>
<p>
<bold>Competing interests:</bold>
None.</p>
</fn>
<fn>
<p>
<bold>Patient consent:</bold>
Obtained.</p>
</fn>
<fn>
<p>
<bold>Ethics approval:</bold>
Camberwell St Giles National Research Ethics Service, London.</p>
</fn>
<fn>
<p>
<bold>Provenance and peer review:</bold>
Not commissioned; externally peer reviewed.</p>
</fn>
<fn>
<p>
<bold>Data sharing statement:</bold>
Please contact the corresponding author for further questions regarding data sharing.</p>
</fn>
</fn-group>
<ref-list>
<title>References</title>
<ref id="R1">
<label>1</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wheatstone</surname>
<given-names>C</given-names>
</name>
</person-group>
<article-title>Contributions to the physiology of vision—Part the first. On some remarkable, and hitherto unobserved, phenomena of binocular vision</article-title>
.
<source>Phil Trans R Soc Lond</source>
<year>1838</year>
;
<volume>128</volume>
:
<fpage>371</fpage>
<lpage>94</lpage>
.</mixed-citation>
</ref>
<ref id="R2">
<label>2</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fielder</surname>
<given-names>AR</given-names>
</name>
<name>
<surname>Moseley</surname>
<given-names>MJ</given-names>
</name>
</person-group>
<article-title>Does stereopsis matter in humans?</article-title>
<source>Eye (Lond)</source>
<year>1996</year>
;
<volume>10</volume>
:
<fpage>233</fpage>
<lpage>8</lpage>
.
<pub-id pub-id-type="pmid">8776453</pub-id>
</mixed-citation>
</ref>
<ref id="R3">
<label>3</label>
<mixed-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Ansons</surname>
<given-names>MA</given-names>
</name>
<name>
<surname>Davis</surname>
<given-names>H</given-names>
</name>
</person-group>
<source>Diagnosis and management of ocular motility disorders</source>
,
<edition>3rd edn</edition>
<publisher-loc>Oxford</publisher-loc>
:
<publisher-name>Blackwell Publishing</publisher-name>
,
<year>2001</year>
.</mixed-citation>
</ref>
<ref id="R4">
<label>4</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schreuder</surname>
<given-names>HWR</given-names>
</name>
<name>
<surname>van den Berg</surname>
<given-names>CB</given-names>
</name>
<name>
<surname>Hazebroek</surname>
<given-names>EJ</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Laparoscopic skills training using inexpensive box trainers: which exercises to choose when constructing a validated training course</article-title>
.
<source>BJOG</source>
<year>2011</year>
;
<volume>118</volume>
:
<fpage>1576</fpage>
<lpage>84</lpage>
.
<pub-id pub-id-type="pmid">21981275</pub-id>
</mixed-citation>
</ref>
<ref id="R5">
<label>5</label>
<mixed-citation publication-type="book">
<person-group person-group-type="author">
<name>
<surname>Twisk</surname>
<given-names>JWR</given-names>
</name>
</person-group>
<source>Applied longitudinal data analysis for epidemiology: a practical guide</source>
.
<publisher-loc>Cambridge</publisher-loc>
:
<publisher-name>Cambridge University Press</publisher-name>
,
<year>2003</year>
.</mixed-citation>
</ref>
<ref id="R6">
<label>6</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barlow</surname>
<given-names>HB</given-names>
</name>
<name>
<surname>Blakemore</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Pettigrew</surname>
<given-names>JD</given-names>
</name>
</person-group>
<article-title>The neural mechanism of binocular depth discrimination</article-title>
.
<source>J Physiol</source>
<year>1997</year>
;
<volume>193</volume>
:
<fpage>327</fpage>
<lpage>42</lpage>
.
<pub-id pub-id-type="pmid">6065881</pub-id>
</mixed-citation>
</ref>
<ref id="R7">
<label>7</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Westheimer</surname>
<given-names>G</given-names>
</name>
</person-group>
<article-title>The Ferrier Lecture, 1992—seeing depth with two eyes: stereopsis</article-title>
.
<source>Proc Biol Sci</source>
<year>1994</year>
;
<volume>257</volume>
:
<fpage>205</fpage>
<lpage>14</lpage>
.
<pub-id pub-id-type="pmid">7972166</pub-id>
</mixed-citation>
</ref>
<ref id="R8">
<label>8</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gallagher</surname>
<given-names>AG</given-names>
</name>
<name>
<surname>Ritter</surname>
<given-names>EM</given-names>
</name>
<name>
<surname>Lederman</surname>
<given-names>AB</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Video-assisted surgery represents more than a loss of three-dimensional vision</article-title>
.
<source>Am Jour Surg</source>
<year>2005</year>
;
<volume>189</volume>
:
<fpage>76</fpage>
<lpage>80</lpage>
.
<pub-id pub-id-type="pmid">15701497</pub-id>
</mixed-citation>
</ref>
<ref id="R9">
<label>9</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Melmouth</surname>
<given-names>DR</given-names>
</name>
<name>
<surname>Grant</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Advantages of binocular vision for the control of reaching and grasping</article-title>
.
<source>Exp Brain Res</source>
<year>2006</year>
;
<volume>171</volume>
:
<fpage>371</fpage>
<lpage>88</lpage>
.
<pub-id pub-id-type="pmid">16323004</pub-id>
</mixed-citation>
</ref>
<ref id="R10">
<label>10</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Read</surname>
<given-names>JC</given-names>
</name>
<name>
<surname>Begum</surname>
<given-names>SF</given-names>
</name>
<name>
<surname>McDonald</surname>
<given-names>A</given-names>
</name>
<etal></etal>
</person-group>
<article-title>The binocular advantage in visuomotor tasks involving tools</article-title>
.
<source>Iperception</source>
<year>2013</year>
;
<volume>4</volume>
:
<fpage>101</fpage>
<lpage>10</lpage>
.
<pub-id pub-id-type="pmid">23755355</pub-id>
</mixed-citation>
</ref>
<ref id="R11">
<label>11</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mazyn</surname>
<given-names>LIN</given-names>
</name>
<name>
<surname>Lenoir</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Montagne</surname>
<given-names>G</given-names>
</name>
<etal></etal>
</person-group>
<article-title>The contribution of stereo vision to one-handed catching</article-title>
.
<source>Exp Brain Res</source>
<year>2004</year>
;
<volume>157</volume>
:
<fpage>383</fpage>
<lpage>90</lpage>
.
<pub-id pub-id-type="pmid">15221161</pub-id>
</mixed-citation>
</ref>
<ref id="R12">
<label>12</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Melmouth</surname>
<given-names>DR</given-names>
</name>
<name>
<surname>Finlay</surname>
<given-names>AL</given-names>
</name>
<name>
<surname>Morgan</surname>
<given-names>MJ</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Grasping deficits and adaptations in adults with stereo vision losses</article-title>
.
<source>Inv Ophthalmol Vis Sci</source>
<year>2009</year>
;
<volume>50</volume>
:
<fpage>3711</fpage>
<lpage>20</lpage>
.</mixed-citation>
</ref>
<ref id="R13">
<label>13</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Suttle</surname>
<given-names>CM</given-names>
</name>
<name>
<surname>Melmouth</surname>
<given-names>DR</given-names>
</name>
<name>
<surname>Finlay</surname>
<given-names>AL</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Eye-hand co-ordination skills in children with and without amblyopia</article-title>
.
<source>Invest Ophthalmol Vis Sci</source>
<year>2011</year>
;
<volume>52</volume>
:
<fpage>1851</fpage>
<lpage>64</lpage>
.
<pub-id pub-id-type="pmid">21212188</pub-id>
</mixed-citation>
</ref>
<ref id="R14">
<label>14</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barry</surname>
<given-names>GP</given-names>
</name>
<name>
<surname>Simon</surname>
<given-names>JW</given-names>
</name>
<name>
<surname>Auringer</surname>
<given-names>D</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Performance of strabismic participants using a validated surgical training module: a pilot study</article-title>
.
<source>J AAPOS</source>
<year>2009</year>
;
<volume>13</volume>
:
<fpage>350</fpage>
<lpage>3</lpage>
.
<pub-id pub-id-type="pmid">19683186</pub-id>
</mixed-citation>
</ref>
<ref id="R15">
<label>15</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Suleman</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Paige</surname>
<given-names>J</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Hand-eye dominance and depth perception effects in performance on a basic laparoscopic skills set</article-title>
.
<source>JSLS</source>
<year>2010</year>
;
<volume>14</volume>
:
<fpage>35</fpage>
<lpage>40</lpage>
.
<pub-id pub-id-type="pmid">20529525</pub-id>
</mixed-citation>
</ref>
<ref id="R16">
<label>16</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>O'Connor</surname>
<given-names>AR</given-names>
</name>
<name>
<surname>Birch</surname>
<given-names>EE</given-names>
</name>
<name>
<surname>Anderson</surname>
<given-names>S</given-names>
</name>
<etal></etal>
</person-group>
<article-title>The functional significance of stereopsis</article-title>
.
<source>Invest Ophthalmol Vis Sci</source>
<year>2010</year>
;
<volume>51</volume>
:
<fpage>2019</fpage>
<lpage>23</lpage>
.
<pub-id pub-id-type="pmid">19933184</pub-id>
</mixed-citation>
</ref>
<ref id="R17">
<label>17</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Smith</surname>
<given-names>EL</given-names>
<suffix>III</suffix>
</name>
<name>
<surname>Levi</surname>
<given-names>DM</given-names>
</name>
<name>
<surname>Manny</surname>
<given-names>RE</given-names>
</name>
<etal></etal>
</person-group>
<article-title>The relationship between binocular rivalry and strabismic suppression</article-title>
.
<source>Invest Ophthalmol Vis Sci</source>
<year>1985</year>
;
<volume>26</volume>
:
<fpage>80</fpage>
<lpage>7</lpage>
.
<pub-id pub-id-type="pmid">3967958</pub-id>
</mixed-citation>
</ref>
<ref id="R18">
<label>18</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Loftus</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Servos</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Goodale</surname>
<given-names>MA</given-names>
</name>
<etal></etal>
</person-group>
<article-title>When two eyes are better than one in prehension: monocular viewing and end-point variance</article-title>
.
<source>Exp Brain Res</source>
<year>2004</year>
;
<volume>158</volume>
:
<fpage>317</fpage>
<lpage>27</lpage>
.
<pub-id pub-id-type="pmid">15164152</pub-id>
</mixed-citation>
</ref>
<ref id="R19">
<label>19</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bradshaw</surname>
<given-names>MF</given-names>
</name>
<name>
<surname>Elliott</surname>
<given-names>KM</given-names>
</name>
<name>
<surname>Watt</surname>
<given-names>SJ</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Binocular cues and the control of prehension</article-title>
.
<source>Spat Vis</source>
<year>2004</year>
;
<volume>17</volume>
:
<fpage>95</fpage>
<lpage>110</lpage>
.
<pub-id pub-id-type="pmid">15078014</pub-id>
</mixed-citation>
</ref>
<ref id="R20">
<label>20</label>
<mixed-citation publication-type="other">
<collab>Royal College of Ophthalmologists Specialist Training Curriculum</collab>
.
<comment>
<ext-link ext-link-type="uri" xlink:href="http://curriculum.rcophth.ac.uk/ost">http://curriculum.rcophth.ac.uk/ost</ext-link>
(accessed 6 Sept 2013)</comment>
.</mixed-citation>
</ref>
<ref id="R21">
<label>21</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sachdeva</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Traboulsi</surname>
<given-names>EI</given-names>
</name>
</person-group>
<article-title>Performance of patients with deficient stereoacuity on the EYESi microsurgical simulator</article-title>
.
<source>Am J Ophthalmol</source>
<year>2011</year>
;
<volume>151</volume>
:
<fpage>427</fpage>
<lpage>33</lpage>
.
<pub-id pub-id-type="pmid">21236407</pub-id>
</mixed-citation>
</ref>
<ref id="R22">
<label>22</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Waqar</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Williams</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>J</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Can virtual reality simulation help to determine the importance of stereopsis in intraocular surgery?</article-title>
<source>Br J Ophthalmol</source>
<year>2012</year>
;
<volume>96</volume>
:
<fpage>742</fpage>
<lpage>6</lpage>
.
<pub-id pub-id-type="pmid">22257786</pub-id>
</mixed-citation>
</ref>
<ref id="R23">
<label>23</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Binenbaum</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Volpe</surname>
<given-names>NJ</given-names>
</name>
</person-group>
<article-title>Ophthalmology resident surgical competency: a national survey</article-title>
.
<source>Ophthalmology</source>
<year>2006</year>
;
<volume>113</volume>
:
<fpage>1237</fpage>
<lpage>44</lpage>
.
<pub-id pub-id-type="pmid">16725202</pub-id>
</mixed-citation>
</ref>
<ref id="R24">
<label>24</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shah</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Buckley</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Frisby</surname>
<given-names>J</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Depth cue reliance in surgeons and medical students</article-title>
.
<source>Surg Endosc</source>
<year>2003</year>
;
<volume>17</volume>
:
<fpage>1472</fpage>
<lpage>4</lpage>
.
<pub-id pub-id-type="pmid">12802650</pub-id>
</mixed-citation>
</ref>
<ref id="R25">
<label>25</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rice</surname>
<given-names>ML</given-names>
</name>
<name>
<surname>Leske</surname>
<given-names>DA</given-names>
</name>
<name>
<surname>Smestad</surname>
<given-names>CE</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Results of ocular dominance testing depend on assessment method</article-title>
.
<source>J AAPOS</source>
<year>2008</year>
;
<volume>12</volume>
:
<fpage>365</fpage>
<lpage>9</lpage>
.
<pub-id pub-id-type="pmid">18455935</pub-id>
</mixed-citation>
</ref>
<ref id="R26">
<label>26</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schueneman</surname>
<given-names>AL</given-names>
</name>
<name>
<surname>Pickleman</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Freeark</surname>
<given-names>RJ</given-names>
</name>
</person-group>
<article-title>Age, gender, lateral dominance, and prediction of operative skill among general surgery residents</article-title>
.
<source>Surgery</source>
<year>1985</year>
;
<volume>98</volume>
:
<fpage>506</fpage>
<lpage>15</lpage>
.
<pub-id pub-id-type="pmid">4035571</pub-id>
</mixed-citation>
</ref>
<ref id="R27">
<label>27</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lynch</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Aughwane</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Hammond</surname>
<given-names>TM</given-names>
</name>
</person-group>
<article-title>Video games and surgical ability: a literature review</article-title>
.
<source>J Surg Educ</source>
<year>2010</year>
;
<volume>67</volume>
:
<fpage>184</fpage>
<lpage>9</lpage>
.
<pub-id pub-id-type="pmid">20630431</pub-id>
</mixed-citation>
</ref>
<ref id="R28">
<label>28</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Boyd</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Jung</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Van Sickle</surname>
<given-names>K</given-names>
</name>
<etal></etal>
</person-group>
<article-title>Music experience influences laparoscopic skills performance</article-title>
.
<source>JSLS</source>
<year>2008</year>
;
<volume>12</volume>
:
<fpage>292</fpage>
<lpage>4</lpage>
.
<pub-id pub-id-type="pmid">18765055</pub-id>
</mixed-citation>
</ref>
</ref-list>
</back>
</pmc>
<affiliations>
<list>
<country>
<li>Royaume-Uni</li>
</country>
</list>
<tree>
<country name="Royaume-Uni">
<noRegion>
<name sortKey="Bloch, Edward" sort="Bloch, Edward" uniqKey="Bloch E" first="Edward" last="Bloch">Edward Bloch</name>
</noRegion>
<name sortKey="Bloch, Edward" sort="Bloch, Edward" uniqKey="Bloch E" first="Edward" last="Bloch">Edward Bloch</name>
<name sortKey="Gannon, Laura" sort="Gannon, Laura" uniqKey="Gannon L" first="Laura" last="Gannon">Laura Gannon</name>
<name sortKey="Jain, Saurabh" sort="Jain, Saurabh" uniqKey="Jain S" first="Saurabh" last="Jain">Saurabh Jain</name>
<name sortKey="Jain, Saurabh" sort="Jain, Saurabh" uniqKey="Jain S" first="Saurabh" last="Jain">Saurabh Jain</name>
<name sortKey="Rantell, Khadija" sort="Rantell, Khadija" uniqKey="Rantell K" first="Khadija" last="Rantell">Khadija Rantell</name>
<name sortKey="Uddin, Nabil" sort="Uddin, Nabil" uniqKey="Uddin N" first="Nabil" last="Uddin">Nabil Uddin</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000886 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd -nk 000886 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Checkpoint
   |type=    RBID
   |clé=     PMC:4316921
   |texte=   The effects of absence of stereopsis on performance of a simulated surgical task in two-dimensional and three-dimensional viewing conditions
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/RBID.i   -Sk "pubmed:25185439" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024