Cutaneous Force Feedback as a Sensory Subtraction Technique in Haptics.

Identifieur interne : 004077 ( Ncbi/Merge ); précédent : 004076; suivant : 004078

Cutaneous Force Feedback as a Sensory Subtraction Technique in Haptics.

Auteurs : D. Prattichizzo ; C. Pacchierotti ; G. Rosati

Source :

RBID : pubmed:26964127

Abstract

A novel sensory substitution technique is presented. Kinesthetic and cutaneous force feedback are substituted by cutaneous feedback (CF) only, provided by two wearable devices able to apply forces to the index finger and the thumb, while holding a handle during a teleoperation task. The force pattern, fed back to the user while using the cutaneous devices, is similar, in terms of intensity and area of application, to the cutaneous force pattern applied to the finger pad while interacting with a haptic device providing both cutaneous and kinesthetic force feedback. The pattern generated using the cutaneous devices can be thought as a subtraction between the complete haptic feedback (HF) and the kinesthetic part of it. For this reason, we refer to this approach as sensory subtraction instead of sensory substitution. A needle insertion scenario is considered to validate the approach. The haptic device is connected to a virtual environment simulating a needle insertion task. Experiments show that the perception of inserting a needle using the cutaneous-only force feedback is nearly indistinguishable from the one felt by the user while using both cutaneous and kinesthetic feedback. As most of the sensory substitution approaches, the proposed sensory subtraction technique also has the advantage of not suffering from stability issues of teleoperation systems due, for instance, to communication delays. Moreover, experiments show that the sensory subtraction technique outperforms sensory substitution with more conventional visual feedback (VF).

DOI: 10.1109/TOH.2012.15
PubMed: 26964127

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:26964127

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Cutaneous Force Feedback as a Sensory Subtraction Technique in Haptics.</title>
<author>
<name sortKey="Prattichizzo, D" sort="Prattichizzo, D" uniqKey="Prattichizzo D" first="D" last="Prattichizzo">D. Prattichizzo</name>
</author>
<author>
<name sortKey="Pacchierotti, C" sort="Pacchierotti, C" uniqKey="Pacchierotti C" first="C" last="Pacchierotti">C. Pacchierotti</name>
</author>
<author>
<name sortKey="Rosati, G" sort="Rosati, G" uniqKey="Rosati G" first="G" last="Rosati">G. Rosati</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="doi">10.1109/TOH.2012.15</idno>
<idno type="RBID">pubmed:26964127</idno>
<idno type="pmid">26964127</idno>
<idno type="wicri:Area/PubMed/Corpus">000D37</idno>
<idno type="wicri:Area/PubMed/Curation">000D37</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000B68</idno>
<idno type="wicri:Area/Ncbi/Merge">004077</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Cutaneous Force Feedback as a Sensory Subtraction Technique in Haptics.</title>
<author>
<name sortKey="Prattichizzo, D" sort="Prattichizzo, D" uniqKey="Prattichizzo D" first="D" last="Prattichizzo">D. Prattichizzo</name>
</author>
<author>
<name sortKey="Pacchierotti, C" sort="Pacchierotti, C" uniqKey="Pacchierotti C" first="C" last="Pacchierotti">C. Pacchierotti</name>
</author>
<author>
<name sortKey="Rosati, G" sort="Rosati, G" uniqKey="Rosati G" first="G" last="Rosati">G. Rosati</name>
</author>
</analytic>
<series>
<title level="j">IEEE transactions on haptics</title>
<idno type="ISSN">1939-1412</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A novel sensory substitution technique is presented. Kinesthetic and cutaneous force feedback are substituted by cutaneous feedback (CF) only, provided by two wearable devices able to apply forces to the index finger and the thumb, while holding a handle during a teleoperation task. The force pattern, fed back to the user while using the cutaneous devices, is similar, in terms of intensity and area of application, to the cutaneous force pattern applied to the finger pad while interacting with a haptic device providing both cutaneous and kinesthetic force feedback. The pattern generated using the cutaneous devices can be thought as a subtraction between the complete haptic feedback (HF) and the kinesthetic part of it. For this reason, we refer to this approach as sensory subtraction instead of sensory substitution. A needle insertion scenario is considered to validate the approach. The haptic device is connected to a virtual environment simulating a needle insertion task. Experiments show that the perception of inserting a needle using the cutaneous-only force feedback is nearly indistinguishable from the one felt by the user while using both cutaneous and kinesthetic feedback. As most of the sensory substitution approaches, the proposed sensory subtraction technique also has the advantage of not suffering from stability issues of teleoperation systems due, for instance, to communication delays. Moreover, experiments show that the sensory subtraction technique outperforms sensory substitution with more conventional visual feedback (VF).</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE">
<PMID Version="1">26964127</PMID>
<DateCreated>
<Year>2016</Year>
<Month>03</Month>
<Day>11</Day>
</DateCreated>
<DateCompleted>
<Year>2016</Year>
<Month>03</Month>
<Day>12</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1939-1412</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>5</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2012</Year>
</PubDate>
</JournalIssue>
<Title>IEEE transactions on haptics</Title>
<ISOAbbreviation>IEEE Trans Haptics</ISOAbbreviation>
</Journal>
<ArticleTitle>Cutaneous Force Feedback as a Sensory Subtraction Technique in Haptics.</ArticleTitle>
<Pagination>
<MedlinePgn>289-300</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1109/TOH.2012.15</ELocationID>
<Abstract>
<AbstractText>A novel sensory substitution technique is presented. Kinesthetic and cutaneous force feedback are substituted by cutaneous feedback (CF) only, provided by two wearable devices able to apply forces to the index finger and the thumb, while holding a handle during a teleoperation task. The force pattern, fed back to the user while using the cutaneous devices, is similar, in terms of intensity and area of application, to the cutaneous force pattern applied to the finger pad while interacting with a haptic device providing both cutaneous and kinesthetic force feedback. The pattern generated using the cutaneous devices can be thought as a subtraction between the complete haptic feedback (HF) and the kinesthetic part of it. For this reason, we refer to this approach as sensory subtraction instead of sensory substitution. A needle insertion scenario is considered to validate the approach. The haptic device is connected to a virtual environment simulating a needle insertion task. Experiments show that the perception of inserting a needle using the cutaneous-only force feedback is nearly indistinguishable from the one felt by the user while using both cutaneous and kinesthetic feedback. As most of the sensory substitution approaches, the proposed sensory subtraction technique also has the advantage of not suffering from stability issues of teleoperation systems due, for instance, to communication delays. Moreover, experiments show that the sensory subtraction technique outperforms sensory substitution with more conventional visual feedback (VF).</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Prattichizzo</LastName>
<ForeName>D</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Pacchierotti</LastName>
<ForeName>C</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Rosati</LastName>
<ForeName>G</ForeName>
<Initials>G</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>IEEE Trans Haptics</MedlineTA>
<NlmUniqueID>101491191</NlmUniqueID>
<ISSNLinking>1939-1412</ISSNLinking>
</MedlineJournalInfo>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2016</Year>
<Month>3</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2012</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2012</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1109/TOH.2012.15</ArticleId>
<ArticleId IdType="pubmed">26964127</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Pacchierotti, C" sort="Pacchierotti, C" uniqKey="Pacchierotti C" first="C" last="Pacchierotti">C. Pacchierotti</name>
<name sortKey="Prattichizzo, D" sort="Prattichizzo, D" uniqKey="Prattichizzo D" first="D" last="Prattichizzo">D. Prattichizzo</name>
<name sortKey="Rosati, G" sort="Rosati, G" uniqKey="Rosati G" first="G" last="Rosati">G. Rosati</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004077 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 004077 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:26964127
   |texte=   Cutaneous Force Feedback as a Sensory Subtraction Technique in Haptics.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:26964127" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024