Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Stroke Survivors’ Gait Adaptations to a Powered Ankle Foot Orthosis

Identifieur interne : 003392 ( Ncbi/Merge ); précédent : 003391; suivant : 003393

Stroke Survivors’ Gait Adaptations to a Powered Ankle Foot Orthosis

Auteurs : Jeffrey Ward ; Thomas Sugar ; Alexander Boehler ; John Standeven ; Jack R. Engsberg

Source :

RBID : PMC:4203663

Abstract

Background and Purpose

Stroke is the leading cause of long term disability in the United States, and for many it causes loss of gait function. The purpose of this research is to examine stroke survivors’ gait adaptations to training on the Powered Ankle Foot Orthosis (PAFO). Of particular interest is the stroke survivors’ ability to learn how to store and release energy properly while using the device. The PAFO utilizes robotic tendon technology and supports motion with a single degree of freedom, ankle rotation in the sagittal plane. This actuator comprises a motor and series spring. The user interacts with the output side of the spring while the robot controls the input side of the spring such that typical able body ankle moments would be generated, assuming able body ankle kinematics are seen at the output side of the spring.

Methods

Three individuals post-stroke participated in a three week training protocol. Outcome measures (temporal, kinematic, and kinetic) were derived from robot sensors and recorded for every step. These data are used to evaluate each stroke survivor’s adaptations to robotic gait assistance. The robot was worn only on the paretic ankle. For validation of the kinematic results, motion capture data were collected on the third subject.

Results

All subjects showed increased cadence, ankle range of motion, and power generation capabilities. Additionally, all subjects were able to achieve a larger power output than power input from the robot. Motion capture data collected from subject three validated the robot sensor kinematic data on the affected side, but also demonstrated an unexpected gait adaptation on the unaffected ankle.

Conclusions

Sensors on the gait assisting robot provide large volumes of valuable information on how gait parameters change over time. We have developed key gait evaluation metrics based on the available robot sensor information that may be useful to future researchers. All subjects adapted their gait to the robotic assistance, and many of their key metrics moved closer to typical able body values. This suggests that each subject learned to utilize the assistive moments generated by the robot, despite having no predefined ankle trajectory input from the robot. The security of being harnessed on the treadmill led to more dramatic and favorable results.


Url:
DOI: 10.1163/016918611X588907
PubMed: 25339789
PubMed Central: 4203663

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:4203663

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Stroke Survivors’ Gait Adaptations to a Powered Ankle Foot Orthosis</title>
<author>
<name sortKey="Ward, Jeffrey" sort="Ward, Jeffrey" uniqKey="Ward J" first="Jeffrey" last="Ward">Jeffrey Ward</name>
</author>
<author>
<name sortKey="Sugar, Thomas" sort="Sugar, Thomas" uniqKey="Sugar T" first="Thomas" last="Sugar">Thomas Sugar</name>
</author>
<author>
<name sortKey="Boehler, Alexander" sort="Boehler, Alexander" uniqKey="Boehler A" first="Alexander" last="Boehler">Alexander Boehler</name>
</author>
<author>
<name sortKey="Standeven, John" sort="Standeven, John" uniqKey="Standeven J" first="John" last="Standeven">John Standeven</name>
</author>
<author>
<name sortKey="Engsberg, Jack R" sort="Engsberg, Jack R" uniqKey="Engsberg J" first="Jack R." last="Engsberg">Jack R. Engsberg</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">25339789</idno>
<idno type="pmc">4203663</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4203663</idno>
<idno type="RBID">PMC:4203663</idno>
<idno type="doi">10.1163/016918611X588907</idno>
<date when="2011">2011</date>
<idno type="wicri:Area/Pmc/Corpus">001734</idno>
<idno type="wicri:Area/Pmc/Curation">001734</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001970</idno>
<idno type="wicri:Area/Ncbi/Merge">003392</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Stroke Survivors’ Gait Adaptations to a Powered Ankle Foot Orthosis</title>
<author>
<name sortKey="Ward, Jeffrey" sort="Ward, Jeffrey" uniqKey="Ward J" first="Jeffrey" last="Ward">Jeffrey Ward</name>
</author>
<author>
<name sortKey="Sugar, Thomas" sort="Sugar, Thomas" uniqKey="Sugar T" first="Thomas" last="Sugar">Thomas Sugar</name>
</author>
<author>
<name sortKey="Boehler, Alexander" sort="Boehler, Alexander" uniqKey="Boehler A" first="Alexander" last="Boehler">Alexander Boehler</name>
</author>
<author>
<name sortKey="Standeven, John" sort="Standeven, John" uniqKey="Standeven J" first="John" last="Standeven">John Standeven</name>
</author>
<author>
<name sortKey="Engsberg, Jack R" sort="Engsberg, Jack R" uniqKey="Engsberg J" first="Jack R." last="Engsberg">Jack R. Engsberg</name>
</author>
</analytic>
<series>
<title level="j">Advanced robotics : the international journal of the Robotics Society of Japan</title>
<idno type="ISSN">0169-1864</idno>
<imprint>
<date when="2011">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec id="S1">
<title>Background and Purpose</title>
<p id="P1">Stroke is the leading cause of long term disability in the United States, and for many it causes loss of gait function. The purpose of this research is to examine stroke survivors’ gait adaptations to training on the Powered Ankle Foot Orthosis (PAFO). Of particular interest is the stroke survivors’ ability to learn how to store and release energy properly while using the device. The PAFO utilizes robotic tendon technology and supports motion with a single degree of freedom, ankle rotation in the sagittal plane. This actuator comprises a motor and series spring. The user interacts with the output side of the spring while the robot controls the input side of the spring such that typical able body ankle moments would be generated, assuming able body ankle kinematics are seen at the output side of the spring.</p>
</sec>
<sec id="S2">
<title>Methods</title>
<p id="P2">Three individuals post-stroke participated in a three week training protocol. Outcome measures (temporal, kinematic, and kinetic) were derived from robot sensors and recorded for every step. These data are used to evaluate each stroke survivor’s adaptations to robotic gait assistance. The robot was worn only on the paretic ankle. For validation of the kinematic results, motion capture data were collected on the third subject.</p>
</sec>
<sec id="S3">
<title>Results</title>
<p id="P3">All subjects showed increased cadence, ankle range of motion, and power generation capabilities. Additionally, all subjects were able to achieve a larger power output than power input from the robot. Motion capture data collected from subject three validated the robot sensor kinematic data on the affected side, but also demonstrated an unexpected gait adaptation on the unaffected ankle.</p>
</sec>
<sec id="S4">
<title>Conclusions</title>
<p id="P4">Sensors on the gait assisting robot provide large volumes of valuable information on how gait parameters change over time. We have developed key gait evaluation metrics based on the available robot sensor information that may be useful to future researchers. All subjects adapted their gait to the robotic assistance, and many of their key metrics moved closer to typical able body values. This suggests that each subject learned to utilize the assistive moments generated by the robot, despite having no predefined ankle trajectory input from the robot. The security of being harnessed on the treadmill led to more dramatic and favorable results.</p>
</sec>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<pmc-dir>properties manuscript</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-journal-id">101165242</journal-id>
<journal-id journal-id-type="pubmed-jr-id">30252</journal-id>
<journal-id journal-id-type="nlm-ta">Adv Robot</journal-id>
<journal-id journal-id-type="iso-abbrev">Adv Robot</journal-id>
<journal-title-group>
<journal-title>Advanced robotics : the international journal of the Robotics Society of Japan</journal-title>
</journal-title-group>
<issn pub-type="ppub">0169-1864</issn>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">25339789</article-id>
<article-id pub-id-type="pmc">4203663</article-id>
<article-id pub-id-type="doi">10.1163/016918611X588907</article-id>
<article-id pub-id-type="manuscript">NIHMS632551</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Stroke Survivors’ Gait Adaptations to a Powered Ankle Foot Orthosis</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Ward</surname>
<given-names>Jeffrey</given-names>
</name>
<aff id="A1">Arizona State University; Tempe, Arizona 85281</aff>
<email>Jeffrey.A.Ward@asu.edu</email>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Sugar</surname>
<given-names>Thomas</given-names>
</name>
<aff id="A2">Arizona State University; Tempe, Arizona 85281</aff>
<email>Thomas.Sugar@asu.edu</email>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Boehler</surname>
<given-names>Alexander</given-names>
</name>
<aff id="A3">Arizona State University; Tempe, Arizona 85281</aff>
<email>aboehler@asu.edu</email>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Standeven</surname>
<given-names>John</given-names>
</name>
<aff id="A4">Washington University; Saint Louis, Missouri 63130</aff>
<email>standevenj@wusm.wustl.edu</email>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Engsberg</surname>
<given-names>Jack R.</given-names>
</name>
<aff id="A5">Washington University; Saint Louis, Missouri 63130</aff>
<email>engsbergj@wusm.wustl.edu</email>
</contrib>
</contrib-group>
<pub-date pub-type="nihms-submitted">
<day>3</day>
<month>10</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>2</day>
<month>4</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="ppub">
<day>1</day>
<month>1</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="pmc-release">
<day>20</day>
<month>10</month>
<year>2014</year>
</pub-date>
<volume>25</volume>
<issue>15</issue>
<fpage>1879</fpage>
<lpage>1901</lpage>
<pmc-comment>elocation-id from pubmed: 10.1163/016918611X588907</pmc-comment>
<self-uri xlink:href="http://www.tandfonline.com/doi/pdf/10.1163/016918611X588907"></self-uri>
<abstract>
<sec id="S1">
<title>Background and Purpose</title>
<p id="P1">Stroke is the leading cause of long term disability in the United States, and for many it causes loss of gait function. The purpose of this research is to examine stroke survivors’ gait adaptations to training on the Powered Ankle Foot Orthosis (PAFO). Of particular interest is the stroke survivors’ ability to learn how to store and release energy properly while using the device. The PAFO utilizes robotic tendon technology and supports motion with a single degree of freedom, ankle rotation in the sagittal plane. This actuator comprises a motor and series spring. The user interacts with the output side of the spring while the robot controls the input side of the spring such that typical able body ankle moments would be generated, assuming able body ankle kinematics are seen at the output side of the spring.</p>
</sec>
<sec id="S2">
<title>Methods</title>
<p id="P2">Three individuals post-stroke participated in a three week training protocol. Outcome measures (temporal, kinematic, and kinetic) were derived from robot sensors and recorded for every step. These data are used to evaluate each stroke survivor’s adaptations to robotic gait assistance. The robot was worn only on the paretic ankle. For validation of the kinematic results, motion capture data were collected on the third subject.</p>
</sec>
<sec id="S3">
<title>Results</title>
<p id="P3">All subjects showed increased cadence, ankle range of motion, and power generation capabilities. Additionally, all subjects were able to achieve a larger power output than power input from the robot. Motion capture data collected from subject three validated the robot sensor kinematic data on the affected side, but also demonstrated an unexpected gait adaptation on the unaffected ankle.</p>
</sec>
<sec id="S4">
<title>Conclusions</title>
<p id="P4">Sensors on the gait assisting robot provide large volumes of valuable information on how gait parameters change over time. We have developed key gait evaluation metrics based on the available robot sensor information that may be useful to future researchers. All subjects adapted their gait to the robotic assistance, and many of their key metrics moved closer to typical able body values. This suggests that each subject learned to utilize the assistive moments generated by the robot, despite having no predefined ankle trajectory input from the robot. The security of being harnessed on the treadmill led to more dramatic and favorable results.</p>
</sec>
</abstract>
<kwd-group>
<kwd>robotic</kwd>
<kwd>orthosis</kwd>
<kwd>ankle</kwd>
<kwd>gait</kwd>
<kwd>stroke</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Boehler, Alexander" sort="Boehler, Alexander" uniqKey="Boehler A" first="Alexander" last="Boehler">Alexander Boehler</name>
<name sortKey="Engsberg, Jack R" sort="Engsberg, Jack R" uniqKey="Engsberg J" first="Jack R." last="Engsberg">Jack R. Engsberg</name>
<name sortKey="Standeven, John" sort="Standeven, John" uniqKey="Standeven J" first="John" last="Standeven">John Standeven</name>
<name sortKey="Sugar, Thomas" sort="Sugar, Thomas" uniqKey="Sugar T" first="Thomas" last="Sugar">Thomas Sugar</name>
<name sortKey="Ward, Jeffrey" sort="Ward, Jeffrey" uniqKey="Ward J" first="Jeffrey" last="Ward">Jeffrey Ward</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003392 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 003392 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     PMC:4203663
   |texte=   Stroke Survivors’ Gait Adaptations to a Powered Ankle Foot Orthosis
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:25339789" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024