Clinical consequences of acrylic intraocular lens material and design: Nd:YAG-laser capsulotomy rates in 3 x 300 eyes 5 years after phacoemulsification
Identifieur interne : 003936 ( Main/Exploration ); précédent : 003935; suivant : 003937Clinical consequences of acrylic intraocular lens material and design: Nd:YAG-laser capsulotomy rates in 3 x 300 eyes 5 years after phacoemulsification
Auteurs : Björn Johansson [Suède]Source :
- British Journal of Ophthalmology [ 0007-1161 ] ; 2010-04.
Abstract
Background/aims To investigate the incidence of Nd:YAG-laser treatment for posterior capsular opacification (PCO) over a period of 5 years from phacoemulsification in an unselected population, comparing outcomes for three acrylic intraocular lenses (IOLs). Methods Retrospective longitudinal cohort study comprising 900 eyes. Three subgroups of 300 eyes, receiving the AR40, AR40e (Abbott Medical Optics, Santa Ana, California), or BL27 (Bausch & Lomb, Rochester, New York) IOL respectively, were compared. Data on patient age, gender, IOL type, dates of cataract surgery, Nd:YAG-laser treatment and/or death, and visual acuities before/after cataract surgery/Nd:YAG-laser treatment were collected from five sources: cataract operation register, patient administration system, quality control system for cataract operations, Nd:YAG-laser treatment register and clinical patient records. Results 216 eyes (24%) received Nd:YAG-laser treatment over a 5-year period. Statistically significant differences (p<0.001, χ2 test) were found between treatment rates for the three IOLs: AR40 73 eyes (24%), BL27 91 eyes (30%) and AR40e 52 eyes (17%). Eyes of patients who died during the follow-up period had fewer treatments (23/266, 8.6%) than eyes of patients living (193/634, 30%) at the end of the follow-up period. Conclusion In comparison with a hydrophobic acrylic IOL with sharp posterior optic edge, a hydrophilic acrylic IOL was associated with almost twice the number of Nd:YAG-laser treatments over the 5-year period. The results are useful for discussing the economic long-term consequences of choosing an IOL with a design that makes PCO development more or less likely. Caution is advised when applying data from post-mortem PCO studies on living populations.
Url:
- https://api.istex.fr/document/572C62E9B3FFBEB26E8BEA65953AC30765323608/fulltext/pdf
- http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2976308
DOI: 10.1136/bjo.2009.166181
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 004107
- to stream Istex, to step Curation: 004107
- to stream Istex, to step Checkpoint: 000733
- to stream Pmc, to step Corpus: 001C19
- to stream Pmc, to step Curation: 001C19
- to stream Pmc, to step Checkpoint: 002187
- to stream Ncbi, to step Merge: 001300
- to stream Ncbi, to step Curation: 001300
- to stream Ncbi, to step Checkpoint: 001300
- to stream Main, to step Merge: 003994
- to stream Main, to step Curation: 003936
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title>Clinical consequences of acrylic intraocular lens material and design: Nd:YAG-laser capsulotomy rates in 3 x 300 eyes 5 years after phacoemulsification</title>
<author wicri:is="90%"><name sortKey="Johansson, Bjorn" sort="Johansson, Bjorn" uniqKey="Johansson B" first="Björn" last="Johansson">Björn Johansson</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:572C62E9B3FFBEB26E8BEA65953AC30765323608</idno>
<date when="2010" year="2010">2010</date>
<idno type="doi">10.1136/bjo.2009.166181</idno>
<idno type="url">https://api.istex.fr/document/572C62E9B3FFBEB26E8BEA65953AC30765323608/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">004107</idno>
<idno type="wicri:Area/Istex/Curation">004107</idno>
<idno type="wicri:Area/Istex/Checkpoint">000733</idno>
<idno type="wicri:doubleKey">0007-1161:2010:Johansson B:clinical:consequences:of</idno>
<idno type="wicri:source">PMC</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2976308</idno>
<idno type="RBID">PMC:2976308</idno>
<idno type="wicri:Area/Pmc/Corpus">001C19</idno>
<idno type="wicri:Area/Pmc/Curation">001C19</idno>
<idno type="wicri:Area/Pmc/Checkpoint">002187</idno>
<idno type="wicri:Area/Ncbi/Merge">001300</idno>
<idno type="wicri:Area/Ncbi/Curation">001300</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001300</idno>
<idno type="wicri:doubleKey">0007-1161:2009:Johansson B:clinical:consequences:of</idno>
<idno type="wicri:Area/Main/Merge">003994</idno>
<idno type="wicri:Area/Main/Curation">003936</idno>
<idno type="wicri:Area/Main/Exploration">003936</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a">Clinical consequences of acrylic intraocular lens material and design: Nd:YAG-laser capsulotomy rates in 3 x 300 eyes 5 years after phacoemulsification</title>
<author wicri:is="90%"><name sortKey="Johansson, Bjorn" sort="Johansson, Bjorn" uniqKey="Johansson B" first="Björn" last="Johansson">Björn Johansson</name>
<affiliation wicri:level="1"><country wicri:rule="url">Suède</country>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">British Journal of Ophthalmology</title>
<title level="j" type="abbrev">Br J Ophthalmol</title>
<idno type="ISSN">0007-1161</idno>
<idno type="eISSN">1468-2079</idno>
<imprint><publisher>BMJ Publishing Group Ltd.</publisher>
<pubPlace>BMA House, Tavistock Square, London, WC1H 9JR</pubPlace>
<date type="published" when="2010-04">2010-04</date>
<biblScope unit="volume">94</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="450">450</biblScope>
</imprint>
<idno type="ISSN">0007-1161</idno>
</series>
<idno type="istex">572C62E9B3FFBEB26E8BEA65953AC30765323608</idno>
<idno type="DOI">10.1136/bjo.2009.166181</idno>
<idno type="href">bjophthalmol-94-450.pdf</idno>
<idno type="ArticleID">bjo166181</idno>
<idno type="PMID">19828518</idno>
<idno type="local">bjophthalmol;94/4/450</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0007-1161</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass></textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract">Background/aims To investigate the incidence of Nd:YAG-laser treatment for posterior capsular opacification (PCO) over a period of 5 years from phacoemulsification in an unselected population, comparing outcomes for three acrylic intraocular lenses (IOLs). Methods Retrospective longitudinal cohort study comprising 900 eyes. Three subgroups of 300 eyes, receiving the AR40, AR40e (Abbott Medical Optics, Santa Ana, California), or BL27 (Bausch & Lomb, Rochester, New York) IOL respectively, were compared. Data on patient age, gender, IOL type, dates of cataract surgery, Nd:YAG-laser treatment and/or death, and visual acuities before/after cataract surgery/Nd:YAG-laser treatment were collected from five sources: cataract operation register, patient administration system, quality control system for cataract operations, Nd:YAG-laser treatment register and clinical patient records. Results 216 eyes (24%) received Nd:YAG-laser treatment over a 5-year period. Statistically significant differences (p<0.001, χ2 test) were found between treatment rates for the three IOLs: AR40 73 eyes (24%), BL27 91 eyes (30%) and AR40e 52 eyes (17%). Eyes of patients who died during the follow-up period had fewer treatments (23/266, 8.6%) than eyes of patients living (193/634, 30%) at the end of the follow-up period. Conclusion In comparison with a hydrophobic acrylic IOL with sharp posterior optic edge, a hydrophilic acrylic IOL was associated with almost twice the number of Nd:YAG-laser treatments over the 5-year period. The results are useful for discussing the economic long-term consequences of choosing an IOL with a design that makes PCO development more or less likely. Caution is advised when applying data from post-mortem PCO studies on living populations.</div>
</front>
</TEI>
<affiliations><list><country><li>Suède</li>
</country>
</list>
<tree><country name="Suède"><noRegion><name sortKey="Johansson, Bjorn" sort="Johansson, Bjorn" uniqKey="Johansson B" first="Björn" last="Johansson">Björn Johansson</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003936 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003936 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:572C62E9B3FFBEB26E8BEA65953AC30765323608 |texte= Clinical consequences of acrylic intraocular lens material and design: Nd:YAG-laser capsulotomy rates in 3 x 300 eyes 5 years after phacoemulsification }}
This area was generated with Dilib version V0.6.23. |