Mitigation of the hydrogen risk in fusion facilities: the first experimental results
Identifieur interne :
000784 ( PascalFrancis/Corpus );
précédent :
000783;
suivant :
000785
Mitigation of the hydrogen risk in fusion facilities: the first experimental results
Auteurs : C. Maruejouls ;
E. Bachellerie ;
C. Latge ;
A. Laurent ;
J. M. Le Lann ;
J. C. Robin ;
S. RosanvallonSource :
-
Fusion engineering and design [ 0920-3796 ] ; 2003.
RBID : Pascal:04-0043756
Descripteurs français
English descriptors
Abstract
A process eliminating hydrogen in an anaerobic medium which could mitigate the hydrogen risk in a fusion facility has been developed. The principle is based on the reduction of manganese oxides by hydrogen, a reaction that produces inferior oxides and water. In order to determine the kinetics of this reaction, a study is being conducted to identify the parameters of the kinetics by comparing the results provided by the established model with those obtained during the test campaign. This paper presents the first experimental results.
Notice en format standard (ISO 2709)
Pour connaître la documentation sur le format Inist Standard.
pA |
A01 | 01 | 1 | | @0 0920-3796 |
---|
A02 | 01 | | | @0 FEDEEE |
---|
A03 | | 1 | | @0 Fusion eng. des. |
---|
A05 | | | | @2 69 |
---|
A06 | | | | @2 1-4 |
---|
A08 | 01 | 1 | ENG | @1 Mitigation of the hydrogen risk in fusion facilities: the first experimental results |
---|
A09 | 01 | 1 | ENG | @1 Proceedings of the 22nd Symposium on Fusion Technology (SOFT-22), Helsinki, Finland, September 9-13, 2002. Part B |
---|
A11 | 01 | 1 | | @1 MARUEJOULS (C.) |
---|
A11 | 02 | 1 | | @1 BACHELLERIE (E.) |
---|
A11 | 03 | 1 | | @1 LATGE (C.) |
---|
A11 | 04 | 1 | | @1 LAURENT (A.) |
---|
A11 | 05 | 1 | | @1 LE LANN (J. M.) |
---|
A11 | 06 | 1 | | @1 ROBIN (J. C.) |
---|
A11 | 07 | 1 | | @1 ROSANVALLON (S.) |
---|
A12 | 01 | 1 | | @1 TÄHTINEN (Seppo) @9 ed. |
---|
A12 | 02 | 1 | | @1 ASIKAINEN (Merja) @9 ed. |
---|
A12 | 03 | 1 | | @1 RINTAMAA (Rauno) @9 ed. |
---|
A12 | 04 | 1 | | @1 TUOMISTO (Harri) @9 ed. |
---|
A14 | 01 | | | @1 CEA/DEN/CAD-CE Cadarache @2 13108 Saint-Paul lez Durance @3 FRA @Z 1 aut. @Z 3 aut. @Z 6 aut. @Z 7 aut. |
---|
A14 | 02 | | | @1 Technicatome-Direction de l'Ingénierie, Service d'Etudes Physiques et de Súreté, BP 34000 @2 13791 Aix-en-Provence @3 FRA @Z 2 aut. |
---|
A14 | 03 | | | @1 Laboratoire des Sciences du Génie Chimique-CNRS-ENSIC-INPL, 1 rue Grandville, BP 451 @2 54001 Nancy @3 FRA @Z 4 aut. |
---|
A14 | 04 | | | @1 INPT-ENSIACET, LGC UMR CNRS 5503, 118, route de Narbonne @2 31077 Toulouse @3 FRA @Z 5 aut. |
---|
A15 | 01 | | | @1 Association EURATOM-Tekes, VTT Industrial Systems @2 Espoo @3 FIN @Z 1 aut. @Z 2 aut. @Z 3 aut. |
---|
A15 | 02 | | | @1 Fortum Nuclear Service Ltd @2 Vantaa @3 FIN @Z 4 aut. |
---|
A20 | | | | @1 585-591 |
---|
A21 | | | | @1 2003 |
---|
A23 | 01 | | | @0 ENG |
---|
A43 | 01 | | | @1 INIST @2 12262F @5 354000112959540950 |
---|
A44 | | | | @0 0000 @1 © 2004 INIST-CNRS. All rights reserved. |
---|
A45 | | | | @0 3 ref. |
---|
A47 | 01 | 1 | | @0 04-0043756 |
---|
A60 | | | | @1 P @2 C |
---|
A61 | | | | @0 A |
---|
A64 | 01 | 1 | | @0 Fusion engineering and design |
---|
A66 | 01 | | | @0 NLD |
---|
C01 | 01 | | ENG | @0 A process eliminating hydrogen in an anaerobic medium which could mitigate the hydrogen risk in a fusion facility has been developed. The principle is based on the reduction of manganese oxides by hydrogen, a reaction that produces inferior oxides and water. In order to determine the kinetics of this reaction, a study is being conducted to identify the parameters of the kinetics by comparing the results provided by the established model with those obtained during the test campaign. This paper presents the first experimental results. |
---|
C02 | 01 | X | | @0 001D06D04E |
---|
C02 | 02 | X | | @0 230 |
---|
C03 | 01 | X | FRE | @0 Hydrogène @2 NC @5 01 |
---|
C03 | 01 | X | ENG | @0 Hydrogen @2 NC @5 01 |
---|
C03 | 01 | X | SPA | @0 Hidrógeno @2 NC @5 01 |
---|
C03 | 02 | X | FRE | @0 Réacteur fusion nucléaire @5 02 |
---|
C03 | 02 | X | ENG | @0 Nuclear fusion reactor @5 02 |
---|
C03 | 02 | X | SPA | @0 Reactor fusión nuclear @5 02 |
---|
C03 | 03 | X | FRE | @0 Manganèse @2 NC @5 03 |
---|
C03 | 03 | X | ENG | @0 Manganese @2 NC @5 03 |
---|
C03 | 03 | X | SPA | @0 Manganeso @2 NC @5 03 |
---|
C03 | 04 | X | FRE | @0 Oxyde @2 NA @5 04 |
---|
C03 | 04 | X | ENG | @0 Oxides @2 NA @5 04 |
---|
C03 | 04 | X | SPA | @0 Óxido @2 NA @5 04 |
---|
N21 | | | | @1 026 |
---|
N82 | | | | @1 OTO |
---|
|
pR |
A30 | 01 | 1 | ENG | @1 SOFT-22 Symposium on Fusion Technology @2 22 @3 Helsinki FIN @4 2002-09-09 |
---|
|
Format Inist (serveur)
NO : | PASCAL 04-0043756 INIST |
ET : | Mitigation of the hydrogen risk in fusion facilities: the first experimental results |
AU : | MARUEJOULS (C.); BACHELLERIE (E.); LATGE (C.); LAURENT (A.); LE LANN (J. M.); ROBIN (J. C.); ROSANVALLON (S.); TÄHTINEN (Seppo); ASIKAINEN (Merja); RINTAMAA (Rauno); TUOMISTO (Harri) |
AF : | CEA/DEN/CAD-CE Cadarache/13108 Saint-Paul lez Durance/France (1 aut., 3 aut., 6 aut., 7 aut.); Technicatome-Direction de l'Ingénierie, Service d'Etudes Physiques et de Súreté, BP 34000/13791 Aix-en-Provence/France (2 aut.); Laboratoire des Sciences du Génie Chimique-CNRS-ENSIC-INPL, 1 rue Grandville, BP 451/54001 Nancy/France (4 aut.); INPT-ENSIACET, LGC UMR CNRS 5503, 118, route de Narbonne/31077 Toulouse/France (5 aut.); Association EURATOM-Tekes, VTT Industrial Systems/Espoo/Finlande (1 aut., 2 aut., 3 aut.); Fortum Nuclear Service Ltd/Vantaa/Finlande (4 aut.) |
DT : | Publication en série; Congrès; Niveau analytique |
SO : | Fusion engineering and design; ISSN 0920-3796; Coden FEDEEE; Pays-Bas; Da. 2003; Vol. 69; No. 1-4; Pp. 585-591; Bibl. 3 ref. |
LA : | Anglais |
EA : | A process eliminating hydrogen in an anaerobic medium which could mitigate the hydrogen risk in a fusion facility has been developed. The principle is based on the reduction of manganese oxides by hydrogen, a reaction that produces inferior oxides and water. In order to determine the kinetics of this reaction, a study is being conducted to identify the parameters of the kinetics by comparing the results provided by the established model with those obtained during the test campaign. This paper presents the first experimental results. |
CC : | 001D06D04E; 230 |
FD : | Hydrogène; Réacteur fusion nucléaire; Manganèse; Oxyde |
ED : | Hydrogen; Nuclear fusion reactor; Manganese; Oxides |
SD : | Hidrógeno; Reactor fusión nuclear; Manganeso; Óxido |
LO : | INIST-12262F.354000112959540950 |
ID : | 04-0043756 |
Links to Exploration step
Pascal:04-0043756
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Mitigation of the hydrogen risk in fusion facilities: the first experimental results</title>
<author><name sortKey="Maruejouls, C" sort="Maruejouls, C" uniqKey="Maruejouls C" first="C." last="Maruejouls">C. Maruejouls</name>
<affiliation><inist:fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Bachellerie, E" sort="Bachellerie, E" uniqKey="Bachellerie E" first="E." last="Bachellerie">E. Bachellerie</name>
<affiliation><inist:fA14 i1="02"><s1>Technicatome-Direction de l'Ingénierie, Service d'Etudes Physiques et de Súreté, BP 34000</s1>
<s2>13791 Aix-en-Provence</s2>
<s3>FRA</s3>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Latge, C" sort="Latge, C" uniqKey="Latge C" first="C." last="Latge">C. Latge</name>
<affiliation><inist:fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Laurent, A" sort="Laurent, A" uniqKey="Laurent A" first="A." last="Laurent">A. Laurent</name>
<affiliation><inist:fA14 i1="03"><s1>Laboratoire des Sciences du Génie Chimique-CNRS-ENSIC-INPL, 1 rue Grandville, BP 451</s1>
<s2>54001 Nancy</s2>
<s3>FRA</s3>
<sZ>4 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Le Lann, J M" sort="Le Lann, J M" uniqKey="Le Lann J" first="J. M." last="Le Lann">J. M. Le Lann</name>
<affiliation><inist:fA14 i1="04"><s1>INPT-ENSIACET, LGC UMR CNRS 5503, 118, route de Narbonne</s1>
<s2>31077 Toulouse</s2>
<s3>FRA</s3>
<sZ>5 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Robin, J C" sort="Robin, J C" uniqKey="Robin J" first="J. C." last="Robin">J. C. Robin</name>
<affiliation><inist:fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Rosanvallon, S" sort="Rosanvallon, S" uniqKey="Rosanvallon S" first="S." last="Rosanvallon">S. Rosanvallon</name>
<affiliation><inist:fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">04-0043756</idno>
<date when="2003">2003</date>
<idno type="stanalyst">PASCAL 04-0043756 INIST</idno>
<idno type="RBID">Pascal:04-0043756</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000784</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Mitigation of the hydrogen risk in fusion facilities: the first experimental results</title>
<author><name sortKey="Maruejouls, C" sort="Maruejouls, C" uniqKey="Maruejouls C" first="C." last="Maruejouls">C. Maruejouls</name>
<affiliation><inist:fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Bachellerie, E" sort="Bachellerie, E" uniqKey="Bachellerie E" first="E." last="Bachellerie">E. Bachellerie</name>
<affiliation><inist:fA14 i1="02"><s1>Technicatome-Direction de l'Ingénierie, Service d'Etudes Physiques et de Súreté, BP 34000</s1>
<s2>13791 Aix-en-Provence</s2>
<s3>FRA</s3>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Latge, C" sort="Latge, C" uniqKey="Latge C" first="C." last="Latge">C. Latge</name>
<affiliation><inist:fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Laurent, A" sort="Laurent, A" uniqKey="Laurent A" first="A." last="Laurent">A. Laurent</name>
<affiliation><inist:fA14 i1="03"><s1>Laboratoire des Sciences du Génie Chimique-CNRS-ENSIC-INPL, 1 rue Grandville, BP 451</s1>
<s2>54001 Nancy</s2>
<s3>FRA</s3>
<sZ>4 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Le Lann, J M" sort="Le Lann, J M" uniqKey="Le Lann J" first="J. M." last="Le Lann">J. M. Le Lann</name>
<affiliation><inist:fA14 i1="04"><s1>INPT-ENSIACET, LGC UMR CNRS 5503, 118, route de Narbonne</s1>
<s2>31077 Toulouse</s2>
<s3>FRA</s3>
<sZ>5 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Robin, J C" sort="Robin, J C" uniqKey="Robin J" first="J. C." last="Robin">J. C. Robin</name>
<affiliation><inist:fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Rosanvallon, S" sort="Rosanvallon, S" uniqKey="Rosanvallon S" first="S." last="Rosanvallon">S. Rosanvallon</name>
<affiliation><inist:fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">Fusion engineering and design</title>
<title level="j" type="abbreviated">Fusion eng. des.</title>
<idno type="ISSN">0920-3796</idno>
<imprint><date when="2003">2003</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Fusion engineering and design</title>
<title level="j" type="abbreviated">Fusion eng. des.</title>
<idno type="ISSN">0920-3796</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Hydrogen</term>
<term>Manganese</term>
<term>Nuclear fusion reactor</term>
<term>Oxides</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Hydrogène</term>
<term>Réacteur fusion nucléaire</term>
<term>Manganèse</term>
<term>Oxyde</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A process eliminating hydrogen in an anaerobic medium which could mitigate the hydrogen risk in a fusion facility has been developed. The principle is based on the reduction of manganese oxides by hydrogen, a reaction that produces inferior oxides and water. In order to determine the kinetics of this reaction, a study is being conducted to identify the parameters of the kinetics by comparing the results provided by the established model with those obtained during the test campaign. This paper presents the first experimental results.</div>
</front>
</TEI>
<inist><standard h6="B"><pA><fA01 i1="01" i2="1"><s0>0920-3796</s0>
</fA01>
<fA02 i1="01"><s0>FEDEEE</s0>
</fA02>
<fA03 i2="1"><s0>Fusion eng. des.</s0>
</fA03>
<fA06><s2>1-4</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG"><s1>Mitigation of the hydrogen risk in fusion facilities: the first experimental results</s1>
</fA08>
<fA09 i1="01" i2="1" l="ENG"><s1>Proceedings of the 22nd Symposium on Fusion Technology (SOFT-22), Helsinki, Finland, September 9-13, 2002. Part B</s1>
</fA09>
<fA11 i1="01" i2="1"><s1>MARUEJOULS (C.)</s1>
</fA11>
<fA11 i1="02" i2="1"><s1>BACHELLERIE (E.)</s1>
</fA11>
<fA11 i1="03" i2="1"><s1>LATGE (C.)</s1>
</fA11>
<fA11 i1="04" i2="1"><s1>LAURENT (A.)</s1>
</fA11>
<fA11 i1="05" i2="1"><s1>LE LANN (J. M.)</s1>
</fA11>
<fA11 i1="06" i2="1"><s1>ROBIN (J. C.)</s1>
</fA11>
<fA11 i1="07" i2="1"><s1>ROSANVALLON (S.)</s1>
</fA11>
<fA12 i1="01" i2="1"><s1>TÄHTINEN (Seppo)</s1>
<s9>ed.</s9>
</fA12>
<fA12 i1="02" i2="1"><s1>ASIKAINEN (Merja)</s1>
<s9>ed.</s9>
</fA12>
<fA12 i1="03" i2="1"><s1>RINTAMAA (Rauno)</s1>
<s9>ed.</s9>
</fA12>
<fA12 i1="04" i2="1"><s1>TUOMISTO (Harri)</s1>
<s9>ed.</s9>
</fA12>
<fA14 i1="01"><s1>CEA/DEN/CAD-CE Cadarache</s1>
<s2>13108 Saint-Paul lez Durance</s2>
<s3>FRA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>6 aut.</sZ>
<sZ>7 aut.</sZ>
</fA14>
<fA14 i1="02"><s1>Technicatome-Direction de l'Ingénierie, Service d'Etudes Physiques et de Súreté, BP 34000</s1>
<s2>13791 Aix-en-Provence</s2>
<s3>FRA</s3>
<sZ>2 aut.</sZ>
</fA14>
<fA14 i1="03"><s1>Laboratoire des Sciences du Génie Chimique-CNRS-ENSIC-INPL, 1 rue Grandville, BP 451</s1>
<s2>54001 Nancy</s2>
<s3>FRA</s3>
<sZ>4 aut.</sZ>
</fA14>
<fA14 i1="04"><s1>INPT-ENSIACET, LGC UMR CNRS 5503, 118, route de Narbonne</s1>
<s2>31077 Toulouse</s2>
<s3>FRA</s3>
<sZ>5 aut.</sZ>
</fA14>
<fA15 i1="01"><s1>Association EURATOM-Tekes, VTT Industrial Systems</s1>
<s2>Espoo</s2>
<s3>FIN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</fA15>
<fA15 i1="02"><s1>Fortum Nuclear Service Ltd</s1>
<s2>Vantaa</s2>
<s3>FIN</s3>
<sZ>4 aut.</sZ>
</fA15>
<fA20><s1>585-591</s1>
</fA20>
<fA21><s1>2003</s1>
</fA21>
<fA23 i1="01"><s0>ENG</s0>
</fA23>
<fA43 i1="01"><s1>INIST</s1>
<s2>12262F</s2>
<s5>354000112959540950</s5>
</fA43>
<fA44><s0>0000</s0>
<s1>© 2004 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45><s0>3 ref.</s0>
</fA45>
<fA47 i1="01" i2="1"><s0>04-0043756</s0>
</fA47>
<fA60><s1>P</s1>
<s2>C</s2>
</fA60>
<fA64 i1="01" i2="1"><s0>Fusion engineering and design</s0>
</fA64>
<fA66 i1="01"><s0>NLD</s0>
</fA66>
<fC01 i1="01" l="ENG"><s0>A process eliminating hydrogen in an anaerobic medium which could mitigate the hydrogen risk in a fusion facility has been developed. The principle is based on the reduction of manganese oxides by hydrogen, a reaction that produces inferior oxides and water. In order to determine the kinetics of this reaction, a study is being conducted to identify the parameters of the kinetics by comparing the results provided by the established model with those obtained during the test campaign. This paper presents the first experimental results.</s0>
</fC01>
<fC02 i1="01" i2="X"><s0>001D06D04E</s0>
</fC02>
<fC02 i1="02" i2="X"><s0>230</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE"><s0>Hydrogène</s0>
<s2>NC</s2>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG"><s0>Hydrogen</s0>
<s2>NC</s2>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA"><s0>Hidrógeno</s0>
<s2>NC</s2>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE"><s0>Réacteur fusion nucléaire</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG"><s0>Nuclear fusion reactor</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA"><s0>Reactor fusión nuclear</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE"><s0>Manganèse</s0>
<s2>NC</s2>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG"><s0>Manganese</s0>
<s2>NC</s2>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA"><s0>Manganeso</s0>
<s2>NC</s2>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE"><s0>Oxyde</s0>
<s2>NA</s2>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG"><s0>Oxides</s0>
<s2>NA</s2>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA"><s0>Óxido</s0>
<s2>NA</s2>
<s5>04</s5>
</fC03>
<fN21><s1>026</s1>
</fN21>
<fN82><s1>OTO</s1>
</fN82>
</pA>
<pR><fA30 i1="01" i2="1" l="ENG"><s1>SOFT-22 Symposium on Fusion Technology</s1>
<s2>22</s2>
<s3>Helsinki FIN</s3>
<s4>2002-09-09</s4>
</fA30>
</pR>
</standard>
<server><NO>PASCAL 04-0043756 INIST</NO>
<ET>Mitigation of the hydrogen risk in fusion facilities: the first experimental results</ET>
<AU>MARUEJOULS (C.); BACHELLERIE (E.); LATGE (C.); LAURENT (A.); LE LANN (J. M.); ROBIN (J. C.); ROSANVALLON (S.); TÄHTINEN (Seppo); ASIKAINEN (Merja); RINTAMAA (Rauno); TUOMISTO (Harri)</AU>
<AF>CEA/DEN/CAD-CE Cadarache/13108 Saint-Paul lez Durance/France (1 aut., 3 aut., 6 aut., 7 aut.); Technicatome-Direction de l'Ingénierie, Service d'Etudes Physiques et de Súreté, BP 34000/13791 Aix-en-Provence/France (2 aut.); Laboratoire des Sciences du Génie Chimique-CNRS-ENSIC-INPL, 1 rue Grandville, BP 451/54001 Nancy/France (4 aut.); INPT-ENSIACET, LGC UMR CNRS 5503, 118, route de Narbonne/31077 Toulouse/France (5 aut.); Association EURATOM-Tekes, VTT Industrial Systems/Espoo/Finlande (1 aut., 2 aut., 3 aut.); Fortum Nuclear Service Ltd/Vantaa/Finlande (4 aut.)</AF>
<DT>Publication en série; Congrès; Niveau analytique</DT>
<SO>Fusion engineering and design; ISSN 0920-3796; Coden FEDEEE; Pays-Bas; Da. 2003; Vol. 69; No. 1-4; Pp. 585-591; Bibl. 3 ref.</SO>
<LA>Anglais</LA>
<EA>A process eliminating hydrogen in an anaerobic medium which could mitigate the hydrogen risk in a fusion facility has been developed. The principle is based on the reduction of manganese oxides by hydrogen, a reaction that produces inferior oxides and water. In order to determine the kinetics of this reaction, a study is being conducted to identify the parameters of the kinetics by comparing the results provided by the established model with those obtained during the test campaign. This paper presents the first experimental results.</EA>
<CC>001D06D04E; 230</CC>
<FD>Hydrogène; Réacteur fusion nucléaire; Manganèse; Oxyde</FD>
<ED>Hydrogen; Nuclear fusion reactor; Manganese; Oxides</ED>
<SD>Hidrógeno; Reactor fusión nuclear; Manganeso; Óxido</SD>
<LO>INIST-12262F.354000112959540950</LO>
<ID>04-0043756</ID>
</server>
</inist>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Lorraine/explor/LrgpV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000784 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 000784 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien
|wiki= Wicri/Lorraine
|area= LrgpV1
|flux= PascalFrancis
|étape= Corpus
|type= RBID
|clé= Pascal:04-0043756
|texte= Mitigation of the hydrogen risk in fusion facilities: the first experimental results
}}
| This area was generated with Dilib version V0.6.32. Data generation: Sat Nov 11 15:47:48 2017. Site generation: Wed Mar 6 23:31:34 2024 | |