Toxicity of used orthodontic archwires assessed by three-dimensional cell culture

Identifieur interne : 001583 ( Main/Exploration ); précédent : 001582; suivant : 001584

Toxicity of used orthodontic archwires assessed by three-dimensional cell culture

Auteurs : Bart Vande Vannet [Belgique] ; Nahid Mohebbian [Belgique] ; Heinrich Wehrbein [Allemagne]

Source :

RBID : ISTEX:F2A399013D09747F16E9673D25D5B4EE91973DAD

Abstract

The aim of the present study was to determine whether used orthodontic wires made of different materials cause toxicity and loss of viability on three-dimensional (3D) cell cultures. Three types of orthodontic wires, stainless steel, Nitinol, and TMA (n 9) which had been used clinically in fixed appliances for a period of 1 month, were retrieved at random from five patients. Both upper and lower archwires were collected and subjected to two different protocols: to assess toxicity, two pieces of each wire were placed on 3D cell cultures (reconstituted human epithelium); to investigate the possibility of cell damage, the 3-(4,5-dimethylthiazol-2-yl)2,5-diphenyl tetrazolium bromide (MTT) assay was used and haematoxylin and eosin staining was performed to evaluate morphological changes. Copper wire served as the control to determine the morphology of severe toxicity, and native cell cultures and silk were used as the negative controls. Morphological evaluation of the native cell cultures revealed no toxic reactions. The ranking, from mild to severe toxicity was as follows: stainless steel < Nitinol TMA. There were no significant differences between TMA and Nitinol. The MTT assay revealed the following mean percentage values for viability: native cell line (negative control), 100; stainless steel, 102.25; TMA, 87.4; Nitinol, 85.3; and copper wire (positive control) 57.2. Histological evaluation of the 3D cell cultures showed no severe toxicity or loss of viability for any of the wires. However, relative comparison between the different wires revealed that stainless steel induced less toxicity/loss of viability compared with TMA and Nitinol wire.

Url:
DOI: 10.1093/ejo/cjl002


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>Toxicity of used orthodontic archwires assessed by three-dimensional cell culture</title>
<author>
<name sortKey="Vande Vannet, Bart" sort="Vande Vannet, Bart" uniqKey="Vande Vannet B" first="Bart" last="Vande Vannet">Bart Vande Vannet</name>
</author>
<author>
<name sortKey="Mohebbian, Nahid" sort="Mohebbian, Nahid" uniqKey="Mohebbian N" first="Nahid" last="Mohebbian">Nahid Mohebbian</name>
</author>
<author>
<name sortKey="Wehrbein, Heinrich" sort="Wehrbein, Heinrich" uniqKey="Wehrbein H" first="Heinrich" last="Wehrbein">Heinrich Wehrbein</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:F2A399013D09747F16E9673D25D5B4EE91973DAD</idno>
<date when="2006" year="2006">2006</date>
<idno type="doi">10.1093/ejo/cjl002</idno>
<idno type="url">https://api.istex.fr/document/F2A399013D09747F16E9673D25D5B4EE91973DAD/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000568</idno>
<idno type="wicri:Area/Istex/Curation">000568</idno>
<idno type="wicri:Area/Istex/Checkpoint">001029</idno>
<idno type="wicri:doubleKey">0141-5387:2006:Vande Vannet B:toxicity:of:used</idno>
<idno type="wicri:Area/Main/Merge">001591</idno>
<idno type="wicri:Area/Main/Curation">001583</idno>
<idno type="wicri:Area/Main/Exploration">001583</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">Toxicity of used orthodontic archwires assessed by three-dimensional cell culture</title>
<author>
<name sortKey="Vande Vannet, Bart" sort="Vande Vannet, Bart" uniqKey="Vande Vannet B" first="Bart" last="Vande Vannet">Bart Vande Vannet</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Department of Orthodontics, Free University of Brussels</wicri:regionArea>
<wicri:noRegion>Free University of Brussels</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1">
<country wicri:rule="url">Belgique</country>
</affiliation>
</author>
<author>
<name sortKey="Mohebbian, Nahid" sort="Mohebbian, Nahid" uniqKey="Mohebbian N" first="Nahid" last="Mohebbian">Nahid Mohebbian</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Department of Restorative Dentistry, Free University of Brussels</wicri:regionArea>
<wicri:noRegion>Free University of Brussels</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Wehrbein, Heinrich" sort="Wehrbein, Heinrich" uniqKey="Wehrbein H" first="Heinrich" last="Wehrbein">Heinrich Wehrbein</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Department of Orthodontics, University of Mainz</wicri:regionArea>
<wicri:noRegion>University of Mainz</wicri:noRegion>
<wicri:noRegion>University of Mainz</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">The European Journal of Orthodontics</title>
<idno type="ISSN">0141-5387</idno>
<idno type="eISSN">1460-2210</idno>
<imprint>
<publisher>Oxford University Press</publisher>
<date type="published" when="2006-08-11">2006-08-11</date>
<biblScope unit="volume">28</biblScope>
<biblScope unit="issue">5</biblScope>
<biblScope unit="page" from="426">426</biblScope>
<biblScope unit="page" to="432">432</biblScope>
</imprint>
<idno type="ISSN">0141-5387</idno>
</series>
<idno type="istex">F2A399013D09747F16E9673D25D5B4EE91973DAD</idno>
<idno type="DOI">10.1093/ejo/cjl002</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0141-5387</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">The aim of the present study was to determine whether used orthodontic wires made of different materials cause toxicity and loss of viability on three-dimensional (3D) cell cultures. Three types of orthodontic wires, stainless steel, Nitinol, and TMA (n 9) which had been used clinically in fixed appliances for a period of 1 month, were retrieved at random from five patients. Both upper and lower archwires were collected and subjected to two different protocols: to assess toxicity, two pieces of each wire were placed on 3D cell cultures (reconstituted human epithelium); to investigate the possibility of cell damage, the 3-(4,5-dimethylthiazol-2-yl)2,5-diphenyl tetrazolium bromide (MTT) assay was used and haematoxylin and eosin staining was performed to evaluate morphological changes. Copper wire served as the control to determine the morphology of severe toxicity, and native cell cultures and silk were used as the negative controls. Morphological evaluation of the native cell cultures revealed no toxic reactions. The ranking, from mild to severe toxicity was as follows: stainless steel < Nitinol TMA. There were no significant differences between TMA and Nitinol. The MTT assay revealed the following mean percentage values for viability: native cell line (negative control), 100; stainless steel, 102.25; TMA, 87.4; Nitinol, 85.3; and copper wire (positive control) 57.2. Histological evaluation of the 3D cell cultures showed no severe toxicity or loss of viability for any of the wires. However, relative comparison between the different wires revealed that stainless steel induced less toxicity/loss of viability compared with TMA and Nitinol wire.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Allemagne</li>
<li>Belgique</li>
</country>
</list>
<tree>
<country name="Belgique">
<noRegion>
<name sortKey="Vande Vannet, Bart" sort="Vande Vannet, Bart" uniqKey="Vande Vannet B" first="Bart" last="Vande Vannet">Bart Vande Vannet</name>
</noRegion>
<name sortKey="Mohebbian, Nahid" sort="Mohebbian, Nahid" uniqKey="Mohebbian N" first="Nahid" last="Mohebbian">Nahid Mohebbian</name>
<name sortKey="Vande Vannet, Bart" sort="Vande Vannet, Bart" uniqKey="Vande Vannet B" first="Bart" last="Vande Vannet">Bart Vande Vannet</name>
</country>
<country name="Allemagne">
<noRegion>
<name sortKey="Wehrbein, Heinrich" sort="Wehrbein, Heinrich" uniqKey="Wehrbein H" first="Heinrich" last="Wehrbein">Heinrich Wehrbein</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Belgique/explor/OpenAccessBelV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001583 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001583 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Belgique
   |area=    OpenAccessBelV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:F2A399013D09747F16E9673D25D5B4EE91973DAD
   |texte=   Toxicity of used orthodontic archwires assessed by three-dimensional cell culture
}}

Wicri

This area was generated with Dilib version V0.6.25.
Data generation: Thu Dec 1 00:43:49 2016. Site generation: Wed Mar 6 14:51:30 2024