Adsorptive stripping voltammetric determination of vanadium as chloranilic acid complex

Identifieur interne : 001234 ( PascalFrancis/Checkpoint ); précédent : 001233; suivant : 001235

Adsorptive stripping voltammetric determination of vanadium as chloranilic acid complex

Auteurs : S. Sander [Allemagne] ; G. Henze [Allemagne]

Source :

RBID : Pascal:96-0461363

Descripteurs français

English descriptors

Abstract

Traces of vanadium(V) can be determined up to 21 ng/l by adsorptive stripping voltammetry using 2,5-dichloro-1,4-dihydroxy-3,6-benzoquinone (chloranilic acid) as complex forming reagent. The complex is stable in a 0.1 mol/l acetate buffer (pH 4.6) solution and adsorbed at the electrode surface in a potential range between - 150 mV and - 400mV. The adsorption process is solved by alternating current (ac) voltammetric measurements. The method is applied to different real samples.


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

Pascal:96-0461363

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Adsorptive stripping voltammetric determination of vanadium as chloranilic acid complex</title>
<author>
<name sortKey="Sander, S" sort="Sander, S" uniqKey="Sander S" first="S." last="Sander">S. Sander</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Fachbereich Chemie, Universität Kaiserlautern and Abteilund für Anorganische und Analytische Chemie, Universität Trier, Postfach 3825</s1>
<s2>54286 Trier</s2>
<s3>DEU</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Allemagne</country>
<wicri:noRegion>54286 Trier</wicri:noRegion>
<wicri:noRegion>Postfach 3825</wicri:noRegion>
<wicri:noRegion>54286 Trier</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Henze, G" sort="Henze, G" uniqKey="Henze G" first="G." last="Henze">G. Henze</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Fachbereich Chemie, Universität Kaiserlautern and Abteilund für Anorganische und Analytische Chemie, Universität Trier, Postfach 3825</s1>
<s2>54286 Trier</s2>
<s3>DEU</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Allemagne</country>
<wicri:noRegion>54286 Trier</wicri:noRegion>
<wicri:noRegion>Postfach 3825</wicri:noRegion>
<wicri:noRegion>54286 Trier</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">96-0461363</idno>
<date when="1996">1996</date>
<idno type="stanalyst">PASCAL 96-0461363 INIST</idno>
<idno type="RBID">Pascal:96-0461363</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001440</idno>
<idno type="wicri:Area/PascalFrancis/Curation">001562</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">001234</idno>
<idno type="wicri:explorRef" wicri:stream="PascalFrancis" wicri:step="Checkpoint">001234</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Adsorptive stripping voltammetric determination of vanadium as chloranilic acid complex</title>
<author>
<name sortKey="Sander, S" sort="Sander, S" uniqKey="Sander S" first="S." last="Sander">S. Sander</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Fachbereich Chemie, Universität Kaiserlautern and Abteilund für Anorganische und Analytische Chemie, Universität Trier, Postfach 3825</s1>
<s2>54286 Trier</s2>
<s3>DEU</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Allemagne</country>
<wicri:noRegion>54286 Trier</wicri:noRegion>
<wicri:noRegion>Postfach 3825</wicri:noRegion>
<wicri:noRegion>54286 Trier</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Henze, G" sort="Henze, G" uniqKey="Henze G" first="G." last="Henze">G. Henze</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Fachbereich Chemie, Universität Kaiserlautern and Abteilund für Anorganische und Analytische Chemie, Universität Trier, Postfach 3825</s1>
<s2>54286 Trier</s2>
<s3>DEU</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Allemagne</country>
<wicri:noRegion>54286 Trier</wicri:noRegion>
<wicri:noRegion>Postfach 3825</wicri:noRegion>
<wicri:noRegion>54286 Trier</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Fresenius' journal of analytical chemistry</title>
<title level="j" type="abbreviated">Fresenius' j. anal. chem.</title>
<idno type="ISSN">0937-0633</idno>
<imprint>
<date when="1996">1996</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Fresenius' journal of analytical chemistry</title>
<title level="j" type="abbreviated">Fresenius' j. anal. chem.</title>
<idno type="ISSN">0937-0633</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Benzoquinone derivatives</term>
<term>Chemical analysis</term>
<term>Fuels</term>
<term>Reoxidation</term>
<term>Trace analysis</term>
<term>Vanadium</term>
<term>Vanadium complex</term>
<term>Voltammetry</term>
<term>Water</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Analyse chimique</term>
<term>Analyse trace</term>
<term>Voltammétrie</term>
<term>Réoxydation</term>
<term>Vanadium</term>
<term>Vanadium complexe</term>
<term>Benzoquinone dérivé</term>
<term>Eau</term>
<term>Combustible</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Vanadium</term>
<term>Eau</term>
<term>Combustible</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Traces of vanadium(V) can be determined up to 21 ng/l by adsorptive stripping voltammetry using 2,5-dichloro-1,4-dihydroxy-3,6-benzoquinone (chloranilic acid) as complex forming reagent. The complex is stable in a 0.1 mol/l acetate buffer (pH 4.6) solution and adsorbed at the electrode surface in a potential range between - 150 mV and - 400mV. The adsorption process is solved by alternating current (ac) voltammetric measurements. The method is applied to different real samples.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0937-0633</s0>
</fA01>
<fA03 i2="1">
<s0>Fresenius' j. anal. chem.</s0>
</fA03>
<fA05>
<s2>356</s2>
</fA05>
<fA06>
<s2>3-4</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Adsorptive stripping voltammetric determination of vanadium as chloranilic acid complex</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>SANDER (S.)</s1>
</fA11>
<fA11 i1="02" i2="1">
<s1>HENZE (G.)</s1>
</fA11>
<fA12 i1="01" i2="1">
<s1>NAUMANN (Renate)</s1>
<s9>ed.</s9>
</fA12>
<fA14 i1="01">
<s1>Fachbereich Chemie, Universität Kaiserlautern and Abteilund für Anorganische und Analytische Chemie, Universität Trier, Postfach 3825</s1>
<s2>54286 Trier</s2>
<s3>DEU</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</fA14>
<fA18 i1="01" i2="1">
<s1>GdCH. Fachgruppe Analytische Chemie. Working Group "Electroanalytical Methods"</s1>
<s3>DEU</s3>
<s9>patr.</s9>
</fA18>
<fA18 i1="02" i2="1">
<s1>Technical University of Clausthal-Zellerfeld</s1>
<s3>DEU</s3>
<s9>patr.</s9>
</fA18>
<fA20>
<s1>259-262</s1>
</fA20>
<fA21>
<s1>1996</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>853</s2>
<s5>354000066286980200</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 1996 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>16 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>96-0461363</s0>
</fA47>
<fA60>
<s1>P</s1>
<s2>C</s2>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Fresenius' journal of analytical chemistry</s0>
</fA64>
<fA66 i1="01">
<s0>DEU</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Traces of vanadium(V) can be determined up to 21 ng/l by adsorptive stripping voltammetry using 2,5-dichloro-1,4-dihydroxy-3,6-benzoquinone (chloranilic acid) as complex forming reagent. The complex is stable in a 0.1 mol/l acetate buffer (pH 4.6) solution and adsorbed at the electrode surface in a potential range between - 150 mV and - 400mV. The adsorption process is solved by alternating current (ac) voltammetric measurements. The method is applied to different real samples.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>001C04E</s0>
</fC02>
<fC03 i1="01" i2="1" l="FRE">
<s0>Analyse chimique</s0>
<s3>P</s3>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="1" l="ENG">
<s0>Chemical analysis</s0>
<s3>P</s3>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="1" l="FRE">
<s0>Analyse trace</s0>
<s5>51</s5>
</fC03>
<fC03 i1="02" i2="1" l="ENG">
<s0>Trace analysis</s0>
<s5>51</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Voltammétrie</s0>
<s5>52</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Voltammetry</s0>
<s5>52</s5>
</fC03>
<fC03 i1="03" i2="X" l="GER">
<s0>Voltammetrie</s0>
<s5>52</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Voltametría</s0>
<s5>52</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Réoxydation</s0>
<s5>53</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Reoxidation</s0>
<s5>53</s5>
</fC03>
<fC03 i1="04" i2="X" l="GER">
<s0>Reoxidation</s0>
<s5>53</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Reoxidación</s0>
<s5>53</s5>
</fC03>
<fC03 i1="05" i2="1" l="FRE">
<s0>Vanadium</s0>
<s1>ANA</s1>
<s2>NC</s2>
<s2>FX</s2>
<s5>54</s5>
</fC03>
<fC03 i1="05" i2="1" l="ENG">
<s0>Vanadium</s0>
<s1>ANA</s1>
<s2>NC</s2>
<s2>FX</s2>
<s5>54</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Vanadium complexe</s0>
<s5>55</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Vanadium complex</s0>
<s5>55</s5>
</fC03>
<fC03 i1="06" i2="X" l="GER">
<s0>Vanadiumkomplex</s0>
<s5>55</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Vanadio complejo</s0>
<s5>55</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Benzoquinone dérivé</s0>
<s5>56</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Benzoquinone derivatives</s0>
<s5>56</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Benzoquinona derivado</s0>
<s5>56</s5>
</fC03>
<fC03 i1="08" i2="1" l="FRE">
<s0>Eau</s0>
<s1>SUB</s1>
<s5>57</s5>
</fC03>
<fC03 i1="08" i2="1" l="ENG">
<s0>Water</s0>
<s1>SUB</s1>
<s5>57</s5>
</fC03>
<fC03 i1="09" i2="1" l="FRE">
<s0>Combustible</s0>
<s5>58</s5>
</fC03>
<fC03 i1="09" i2="1" l="ENG">
<s0>Fuels</s0>
<s5>58</s5>
</fC03>
<fN21>
<s1>316</s1>
</fN21>
</pA>
<pR>
<fA30 i1="01" i2="1" l="ENG">
<s1>ELACH Meeting</s1>
<s2>2</s2>
<s3>Clausthal-Zellerfeld DEU</s3>
<s4>1995-10-02</s4>
</fA30>
</pR>
</standard>
</inist>
<affiliations>
<list>
<country>
<li>Allemagne</li>
</country>
</list>
<tree>
<country name="Allemagne">
<noRegion>
<name sortKey="Sander, S" sort="Sander, S" uniqKey="Sander S" first="S." last="Sander">S. Sander</name>
</noRegion>
<name sortKey="Henze, G" sort="Henze, G" uniqKey="Henze G" first="G." last="Henze">G. Henze</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Rhénanie/explor/UnivTrevesV1/Data/PascalFrancis/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001234 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Checkpoint/biblio.hfd -nk 001234 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Rhénanie
   |area=    UnivTrevesV1
   |flux=    PascalFrancis
   |étape=   Checkpoint
   |type=    RBID
   |clé=     Pascal:96-0461363
   |texte=   Adsorptive stripping voltammetric determination of vanadium as chloranilic acid complex
}}

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Jul 22 16:29:01 2017. Site generation: Wed Feb 28 14:55:37 2024