Image quality and dose management in digital radiography: a new paradigm for optimisation

Identifieur interne : 001489 ( Main/Exploration ); précédent : 001488; suivant : 001490

Image quality and dose management in digital radiography: a new paradigm for optimisation

Auteurs : H. P. Busch [Allemagne] ; K. Faulkner [Royaume-Uni]

Source :

RBID : ISTEX:37D0509598135B74B032B00D81CD3C8BBD70B0A9

English descriptors

Abstract

The advent of digital imaging in radiology, combined with the explosive growth of technology, has dramatically improved imaging techniques. This has led to the expansion of diagnostic capabilities, both in terms of the number of procedures and their scope. Throughout the world, film/screen radiography systems are being rapidly replaced with digital systems. Many progressive medical institutions have acquired, or are considering the purchase of computed radiography systems with strorage phosphor plates or direct digital radiography systems with flat panel detectors. However, unknown to some users, these devices offer a new paradigm of opportunity and challenges. Images can be obtained at a lower dose owing to the higher detective quantum efficiency (DQE). These fundamental differences in comparison to conventional film/screens necessitate the development of new strategies for dose and quality optimisations. A set of referral criteria based upon three dose levels is proposed.

Url:
DOI: 10.1093/rpd/nci728


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Image quality and dose management in digital radiography: a new paradigm for optimisation</title>
<author>
<name sortKey="Busch, H P" sort="Busch, H P" uniqKey="Busch H" first="H. P." last="Busch">H. P. Busch</name>
</author>
<author>
<name sortKey="Faulkner, K" sort="Faulkner, K" uniqKey="Faulkner K" first="K." last="Faulkner">K. Faulkner</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:37D0509598135B74B032B00D81CD3C8BBD70B0A9</idno>
<date when="2006" year="2006">2006</date>
<idno type="doi">10.1093/rpd/nci728</idno>
<idno type="url">https://api.istex.fr/document/37D0509598135B74B032B00D81CD3C8BBD70B0A9/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001174</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001174</idno>
<idno type="wicri:Area/Istex/Curation">001062</idno>
<idno type="wicri:Area/Istex/Checkpoint">000731</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000731</idno>
<idno type="wicri:doubleKey">0144-8420:2006:Busch H:image:quality:and</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:16461521</idno>
<idno type="wicri:Area/PubMed/Corpus">000723</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000723</idno>
<idno type="wicri:Area/PubMed/Curation">000723</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000723</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000723</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000723</idno>
<idno type="wicri:Area/Ncbi/Merge">000223</idno>
<idno type="wicri:Area/Ncbi/Curation">000223</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000223</idno>
<idno type="wicri:doubleKey">0144-8420:2005:Busch H:image:quality:and</idno>
<idno type="wicri:Area/Main/Merge">001631</idno>
<idno type="wicri:Area/Main/Curation">001489</idno>
<idno type="wicri:Area/Main/Exploration">001489</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Image quality and dose management in digital radiography: a new paradigm for optimisation</title>
<author>
<name sortKey="Busch, H P" sort="Busch, H P" uniqKey="Busch H" first="H. P." last="Busch">H. P. Busch</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Department of Radiology, Krankenhaus der Barmherzigen Brudder, Nordalle, Trier</wicri:regionArea>
<wicri:noRegion>Trier</wicri:noRegion>
<wicri:noRegion>Trier</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Faulkner, K" sort="Faulkner, K" uniqKey="Faulkner K" first="K." last="Faulkner">K. Faulkner</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Quality Assurance Reference Centre, Unit 9, Kingfisher Way, Silverlink Business Park, Wallsend, Tyne and Wear NE28 9ND</wicri:regionArea>
<wicri:noRegion>Tyne and Wear NE28 9ND</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Radiation Protection Dosimetry</title>
<title level="j" type="abbrev">Radiat Prot Dosimetry</title>
<idno type="ISSN">0144-8420</idno>
<idno type="eISSN">1742-3406</idno>
<imprint>
<publisher>Oxford University Press</publisher>
<date type="published" when="2005-12">2005-12</date>
<biblScope unit="volume">117</biblScope>
<biblScope unit="issue">1-3</biblScope>
<biblScope unit="page" from="143">143</biblScope>
<biblScope unit="page" to="147">147</biblScope>
</imprint>
<idno type="ISSN">0144-8420</idno>
</series>
<idno type="istex">37D0509598135B74B032B00D81CD3C8BBD70B0A9</idno>
<idno type="DOI">10.1093/rpd/nci728</idno>
<idno type="local">nci728</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0144-8420</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Humans</term>
<term>Occupational Exposure</term>
<term>Phantoms, Imaging</term>
<term>Quality Control</term>
<term>Radiation Dosage</term>
<term>Radiation Protection (instrumentation)</term>
<term>Radiation Protection (methods)</term>
<term>Radiographic Image Enhancement (instrumentation)</term>
<term>Radiographic Image Enhancement (methods)</term>
<term>Radiographic Image Interpretation, Computer-Assisted (instrumentation)</term>
<term>Radiographic Image Interpretation, Computer-Assisted (methods)</term>
<term>Radiography (instrumentation)</term>
<term>Radiography (methods)</term>
<term>Radiography (standards)</term>
<term>Radiometry (instrumentation)</term>
<term>Radiometry (methods)</term>
<term>Technology, Radiologic</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Radiation Protection</term>
<term>Radiographic Image Enhancement</term>
<term>Radiographic Image Interpretation, Computer-Assisted</term>
<term>Radiography</term>
<term>Radiometry</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Radiation Protection</term>
<term>Radiographic Image Enhancement</term>
<term>Radiographic Image Interpretation, Computer-Assisted</term>
<term>Radiography</term>
<term>Radiometry</term>
</keywords>
<keywords scheme="MESH" qualifier="standards" xml:lang="en">
<term>Radiography</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Occupational Exposure</term>
<term>Phantoms, Imaging</term>
<term>Quality Control</term>
<term>Radiation Dosage</term>
<term>Technology, Radiologic</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The advent of digital imaging in radiology, combined with the explosive growth of technology, has dramatically improved imaging techniques. This has led to the expansion of diagnostic capabilities, both in terms of the number of procedures and their scope. Throughout the world, film/screen radiography systems are being rapidly replaced with digital systems. Many progressive medical institutions have acquired, or are considering the purchase of computed radiography systems with strorage phosphor plates or direct digital radiography systems with flat panel detectors. However, unknown to some users, these devices offer a new paradigm of opportunity and challenges. Images can be obtained at a lower dose owing to the higher detective quantum efficiency (DQE). These fundamental differences in comparison to conventional film/screens necessitate the development of new strategies for dose and quality optimisations. A set of referral criteria based upon three dose levels is proposed.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Allemagne</li>
<li>Royaume-Uni</li>
</country>
</list>
<tree>
<country name="Allemagne">
<noRegion>
<name sortKey="Busch, H P" sort="Busch, H P" uniqKey="Busch H" first="H. P." last="Busch">H. P. Busch</name>
</noRegion>
</country>
<country name="Royaume-Uni">
<noRegion>
<name sortKey="Faulkner, K" sort="Faulkner, K" uniqKey="Faulkner K" first="K." last="Faulkner">K. Faulkner</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Rhénanie/explor/UnivTrevesV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001489 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001489 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Rhénanie
   |area=    UnivTrevesV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:37D0509598135B74B032B00D81CD3C8BBD70B0A9
   |texte=   Image quality and dose management in digital radiography: a new paradigm for optimisation
}}

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Jul 22 16:29:01 2017. Site generation: Wed Feb 28 14:55:37 2024