Auteurs : Eberhard Grube [Allemagne] ; Antonio Colombo [Italie] ; Eugen Hauptmann [Allemagne] ; Hugo Londero [Argentine] ; Nicolaus Reifart [Allemagne] ; Ulrich Gerckens [Allemagne] ; Gregg W. Stone [États-Unis]Source :
- Catheterization and Cardiovascular Interventions [ 1522-1946 ] ; 2003-02.
Descripteurs français
- Pascal (Inist)
- Wicri :
- topic : Homme.
English descriptors
- KwdEn :
Abstract
Atheroembolization resulting in transient or permanent neurologic impairment is the most common complication of catheter‐based percutaneous carotid artery intervention. Protection of the distal cerebral vasculature during carotid stent implantation may enhance procedural safety. Carotid stent implantation with distal cerebral protection using the FilterWire EX was performed in 35 consecutive patients undergoing 36 procedures at six centers. The FilterWire was delivered and deployed successfully in all 36 cases, and embolic material was retrieved from 74% of procedures. The 30‐day rate of major adverse events (death, major or minor stroke) was 0%. Transient ipsilateral periprocedural neurologic ischemia developed in two patients (5.7%), both resolving within 30 min. Distal cerebral protection with the FilterWire during carotid stenting is feasible and safe, results in capture and extraction of atheroembolic debris in the majority of patients while affording uninterrupted cerebral perfusion, and in this initial multicenter experience was associated with a high rate of procedural success without major complications. Cathet Cardiovasc Intervent 2003;58:139–146. © 2003 Wiley‐Liss, Inc
Url:
DOI: 10.1002/ccd.10348
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 001098
- to stream Istex, to step Curation: 000F87
- to stream Istex, to step Checkpoint: 000A78
- to stream Main, to step Merge: 001D07
- to stream PascalFrancis, to step Corpus: 000C80
- to stream PascalFrancis, to step Curation: 000235
- to stream PascalFrancis, to step Checkpoint: 000999
- to stream Main, to step Merge: 001D92
- to stream Main, to step Curation: 001A85
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Initial multicenter experience with a novel distal protection filter during carotid artery stent implantation</title>
<author><name sortKey="Grube, Eberhard" sort="Grube, Eberhard" uniqKey="Grube E" first="Eberhard" last="Grube">Eberhard Grube</name>
</author>
<author><name sortKey="Colombo, Antonio" sort="Colombo, Antonio" uniqKey="Colombo A" first="Antonio" last="Colombo">Antonio Colombo</name>
</author>
<author><name sortKey="Hauptmann, Eugen" sort="Hauptmann, Eugen" uniqKey="Hauptmann E" first="Eugen" last="Hauptmann">Eugen Hauptmann</name>
</author>
<author><name sortKey="Londero, Hugo" sort="Londero, Hugo" uniqKey="Londero H" first="Hugo" last="Londero">Hugo Londero</name>
</author>
<author><name sortKey="Reifart, Nicolaus" sort="Reifart, Nicolaus" uniqKey="Reifart N" first="Nicolaus" last="Reifart">Nicolaus Reifart</name>
</author>
<author><name sortKey="Gerckens, Ulrich" sort="Gerckens, Ulrich" uniqKey="Gerckens U" first="Ulrich" last="Gerckens">Ulrich Gerckens</name>
</author>
<author><name sortKey="Stone, Gregg W" sort="Stone, Gregg W" uniqKey="Stone G" first="Gregg W." last="Stone">Gregg W. Stone</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:086AF8EDFF41D570ABE827ABD45B306AEFA0DAA3</idno>
<date when="2003" year="2003">2003</date>
<idno type="doi">10.1002/ccd.10348</idno>
<idno type="url">https://api.istex.fr/document/086AF8EDFF41D570ABE827ABD45B306AEFA0DAA3/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001098</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001098</idno>
<idno type="wicri:Area/Istex/Curation">000F87</idno>
<idno type="wicri:Area/Istex/Checkpoint">000A78</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000A78</idno>
<idno type="wicri:doubleKey">1522-1946:2003:Grube E:initial:multicenter:experience</idno>
<idno type="wicri:Area/Main/Merge">001D07</idno>
<idno type="wicri:source">INIST</idno>
<idno type="RBID">Pascal:03-0143997</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000C80</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000235</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000999</idno>
<idno type="wicri:explorRef" wicri:stream="PascalFrancis" wicri:step="Checkpoint">000999</idno>
<idno type="wicri:doubleKey">1522-1946:2003:Grube E:initial:multicenter:experience</idno>
<idno type="wicri:Area/Main/Merge">001D92</idno>
<idno type="wicri:Area/Main/Curation">001A85</idno>
<idno type="wicri:Area/Main/Exploration">001A85</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Initial multicenter experience with a novel distal protection filter during carotid artery stent implantation</title>
<author><name sortKey="Grube, Eberhard" sort="Grube, Eberhard" uniqKey="Grube E" first="Eberhard" last="Grube">Eberhard Grube</name>
<affiliation wicri:level="1"><country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Heart Center, Siegburg</wicri:regionArea>
<wicri:noRegion>Siegburg</wicri:noRegion>
<wicri:noRegion>Siegburg</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Colombo, Antonio" sort="Colombo, Antonio" uniqKey="Colombo A" first="Antonio" last="Colombo">Antonio Colombo</name>
<affiliation wicri:level="3"><country xml:lang="fr">Italie</country>
<wicri:regionArea>EMO‐Centro Cuore Columbus, Milan</wicri:regionArea>
<placeName><settlement type="city">Milan</settlement>
<region nuts="2">Lombardie</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Hauptmann, Eugen" sort="Hauptmann, Eugen" uniqKey="Hauptmann E" first="Eugen" last="Hauptmann">Eugen Hauptmann</name>
<affiliation wicri:level="1"><country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Krankenhaus D. Barmh Bruder, Trier</wicri:regionArea>
<wicri:noRegion>Trier</wicri:noRegion>
<wicri:noRegion>Trier</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Londero, Hugo" sort="Londero, Hugo" uniqKey="Londero H" first="Hugo" last="Londero">Hugo Londero</name>
<affiliation wicri:level="1"><country xml:lang="fr">Argentine</country>
<wicri:regionArea>Sanatorio Allende–Privado, Buenos Aires</wicri:regionArea>
<wicri:noRegion>Buenos Aires</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Reifart, Nicolaus" sort="Reifart, Nicolaus" uniqKey="Reifart N" first="Nicolaus" last="Reifart">Nicolaus Reifart</name>
<affiliation wicri:level="1"><country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Kardiologisches Institut Main‐Taunus Bad Soden, Bad Soden</wicri:regionArea>
<wicri:noRegion>Bad Soden</wicri:noRegion>
<wicri:noRegion>Bad Soden</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Gerckens, Ulrich" sort="Gerckens, Ulrich" uniqKey="Gerckens U" first="Ulrich" last="Gerckens">Ulrich Gerckens</name>
<affiliation wicri:level="1"><country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Heart Center, Siegburg</wicri:regionArea>
<wicri:noRegion>Siegburg</wicri:noRegion>
<wicri:noRegion>Siegburg</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Stone, Gregg W" sort="Stone, Gregg W" uniqKey="Stone G" first="Gregg W." last="Stone">Gregg W. Stone</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<placeName><region type="state">État de New York</region>
</placeName>
<wicri:cityArea>The Cardiovascular Research Foundation and Lenox Hill Heart and Vascular Institute, New York</wicri:cityArea>
</affiliation>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<placeName><region type="state">État de New York</region>
</placeName>
<wicri:cityArea>The Cardiovascular Research Foundation, 55 E. 59th Street, 6th Floor, New York</wicri:cityArea>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Catheterization and Cardiovascular Interventions</title>
<title level="j" type="abbrev">Cathet. Cardiovasc. Intervent.</title>
<idno type="ISSN">1522-1946</idno>
<idno type="eISSN">1522-726X</idno>
<imprint><publisher>Wiley Subscription Services, Inc., A Wiley Company</publisher>
<pubPlace>New York</pubPlace>
<date type="published" when="2003-02">2003-02</date>
<biblScope unit="volume">58</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="139">139</biblScope>
<biblScope unit="page" to="146">146</biblScope>
</imprint>
<idno type="ISSN">1522-1946</idno>
</series>
<idno type="istex">086AF8EDFF41D570ABE827ABD45B306AEFA0DAA3</idno>
<idno type="DOI">10.1002/ccd.10348</idno>
<idno type="ArticleID">CCD10348</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">1522-1946</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Carotid</term>
<term>Cerebral embolism</term>
<term>Complication</term>
<term>Distal</term>
<term>Endoprosthesis</term>
<term>Filter</term>
<term>Human</term>
<term>Instrumental dilatation</term>
<term>Instrumentation</term>
<term>Prevention</term>
<term>Technique</term>
<term>Treatment</term>
<term>carotid disease</term>
<term>distal protection</term>
<term>emboli</term>
<term>filters</term>
<term>stenting</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Appareillage</term>
<term>Carotide</term>
<term>Complication</term>
<term>Dilatation instrumentale</term>
<term>Distal</term>
<term>Embolie cérébrale</term>
<term>Endoprothèse</term>
<term>Filtre</term>
<term>Homme</term>
<term>Prévention</term>
<term>Technique</term>
<term>Traitement</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Homme</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Atheroembolization resulting in transient or permanent neurologic impairment is the most common complication of catheter‐based percutaneous carotid artery intervention. Protection of the distal cerebral vasculature during carotid stent implantation may enhance procedural safety. Carotid stent implantation with distal cerebral protection using the FilterWire EX was performed in 35 consecutive patients undergoing 36 procedures at six centers. The FilterWire was delivered and deployed successfully in all 36 cases, and embolic material was retrieved from 74% of procedures. The 30‐day rate of major adverse events (death, major or minor stroke) was 0%. Transient ipsilateral periprocedural neurologic ischemia developed in two patients (5.7%), both resolving within 30 min. Distal cerebral protection with the FilterWire during carotid stenting is feasible and safe, results in capture and extraction of atheroembolic debris in the majority of patients while affording uninterrupted cerebral perfusion, and in this initial multicenter experience was associated with a high rate of procedural success without major complications. Cathet Cardiovasc Intervent 2003;58:139–146. © 2003 Wiley‐Liss, Inc</div>
</front>
</TEI>
<affiliations><list><country><li>Allemagne</li>
<li>Argentine</li>
<li>Italie</li>
<li>États-Unis</li>
</country>
<region><li>Lombardie</li>
<li>État de New York</li>
</region>
<settlement><li>Milan</li>
</settlement>
</list>
<tree><country name="Allemagne"><noRegion><name sortKey="Grube, Eberhard" sort="Grube, Eberhard" uniqKey="Grube E" first="Eberhard" last="Grube">Eberhard Grube</name>
</noRegion>
<name sortKey="Gerckens, Ulrich" sort="Gerckens, Ulrich" uniqKey="Gerckens U" first="Ulrich" last="Gerckens">Ulrich Gerckens</name>
<name sortKey="Hauptmann, Eugen" sort="Hauptmann, Eugen" uniqKey="Hauptmann E" first="Eugen" last="Hauptmann">Eugen Hauptmann</name>
<name sortKey="Reifart, Nicolaus" sort="Reifart, Nicolaus" uniqKey="Reifart N" first="Nicolaus" last="Reifart">Nicolaus Reifart</name>
</country>
<country name="Italie"><region name="Lombardie"><name sortKey="Colombo, Antonio" sort="Colombo, Antonio" uniqKey="Colombo A" first="Antonio" last="Colombo">Antonio Colombo</name>
</region>
</country>
<country name="Argentine"><noRegion><name sortKey="Londero, Hugo" sort="Londero, Hugo" uniqKey="Londero H" first="Hugo" last="Londero">Hugo Londero</name>
</noRegion>
</country>
<country name="États-Unis"><region name="État de New York"><name sortKey="Stone, Gregg W" sort="Stone, Gregg W" uniqKey="Stone G" first="Gregg W." last="Stone">Gregg W. Stone</name>
</region>
<name sortKey="Stone, Gregg W" sort="Stone, Gregg W" uniqKey="Stone G" first="Gregg W." last="Stone">Gregg W. Stone</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Rhénanie/explor/UnivTrevesV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001A85 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001A85 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Rhénanie |area= UnivTrevesV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:086AF8EDFF41D570ABE827ABD45B306AEFA0DAA3 |texte= Initial multicenter experience with a novel distal protection filter during carotid artery stent implantation }}
This area was generated with Dilib version V0.6.31. |